Evaluation of polyimide as substrate material for electrodes to interface the peripheral nervous system
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
The introduction of micromachining technologies into design and development of interfaces to the peripheral nervous systems more than 20 years ago led to novel silicon and polymer based microimplants. Polyimide has been chosen as candidate for flexible implants. In this work, the investigations on different designs, the material stability and different aspects of biocompatibility as well as the functional outcome of different electrode designs will be presented. Sieve electrodes to interface regenerating nerves, multichannel cuff electrodes but also newer concepts like longitudinal and transverse intrafascicular multichannel electrodes (LIFE, TIME) have been developed with polyimide as substrate and insulation material. Evaluation in vitro as well as in vivo of the material itself but also of the different electrode designs and concepts showed good material stability, no material toxicity, only little foreign body reaction after implantation and good spatial selectivity of the electrodes depending on the chosen concept to interface the peripheral nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“The new technologies brought a manifold of new designs for peripheral nerve interfaces with different approaches to increase selectivity in stimulation and recording that was necessarily accompanied by higher invasiveness during implantation [3].”
BackgroundSelf-citationSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819 · cited 1×
“In vision prosthesis, polyimide also proved its applicability in neural implants [24].”
BackgroundHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Self-citationA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 3×
“For higher reversible charge injection capacity, electrodes have been coated with sputtered iridium oxide (SIROF), electroplated platinum black [9, 25] and PEDOT [12],.”
BackgroundSelf-citationA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387 · cited 3×
“For higher reversible charge injection capacity, electrodes have been coated with sputtered iridium oxide (SIROF), electroplated platinum black [9, 25] and PEDOT [12],.”
BackgroundSelf-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359 · cited 1×
“Silicon was preferred in only a few approaches, like sieve electrodes or needles [4], and flexible materials like parylene and polyimide have been added as new materials to the established material silicone (polydimethylsilicone-PDMS) [5].”
BackgroundIn vitro evaluation of the long-term stability of polyimide as a material for neural implants
Rubehn, B., & Stieglitz, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.053 · Cited by 242 · cited 1×
“Polyimide specimens (width: 1 mm, length: 40 mm, foil thickness: 7 μm) were microprocessed and stored for 20 months in phosphate buffered saline (PBS) at 37 °C to simulate body environment and at elevated temperatures (60 °C and 85 °C) to accelerate aging [11].”
MethodSelf-citationLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227 · cited 3×
“Sieve electrodes [14, 15], multichannel cuffs [16, 17, 20], thin film LIFEs [18] and TIMEs [9, 19] have been included into different implantation studies.”
BackgroundSelf-citationLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178 · cited 2×
“Sieve electrodes [14, 15] allowed good nerve regeneration, recording and stimulation but are limited to amputation trauma due to their high invasiveness.”
BackgroundSelf-citationQuantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136 · cited 1×
“The ability of fascicle selective electrical stimulation [1] and recording of natural sensor signals [2] for neural prostheses control has already been shown, as well as the limitations with respect to spatial and fiber selectivity.”
BackgroundStieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125 · cited 1×
“to interface regenerating nerves [6, 7], thread like intrafascicular interfaces for longitudinal (LIFE:”
BackgroundSelf-citationMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120 · cited 2×
“Polyimide based electrodes have been evaluated in clinical trials as LIFE in arm nerves in a human to control a hand prostheses with good success [23].”
BackgroundMethodSelf-citationBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103 · cited 3×
“Sieve electrodes [14, 15], multichannel cuffs [16, 17, 20], thin film LIFEs [18] and TIMEs [9, 19] have been included into different implantation studies.”
BackgroundSelf-citationRaspopovic, S., Carpaneto, J., Udina, E., Navarro, X., & Micera, S. (2010) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-7-17 · Cited by 81
Self-citationLong Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75
Cited by
Flexible, Penetrating Brain Probes Enabled by Advances in Polymer Microfabrication
Weltman, A., Yoo, J., & Meng, E. (2016) · Micromachines · doi:10.3390/mi7100180 · Cited by 184
“Many groups have continued to evaluate the effects of polyimide in the brain [37,38], and one recent study confirmed that even the photosensitive formulation caused no toxicity after six months of implantation in a rabbit retina [39].”
BackgroundA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58
“The TIME-3 H have been tested comprehensively in preclinical studies for the envisioned 30 d implantation time of the human study with respect to foreign body reactions [18], scarring [19], acute selectivity [14] and chronic functionality [21] and stability [19].”
MethodSelf-citationImplantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Self-citationDesign and Microfabrication Considerations for Reliable Flexible Intracortical Implants
Sohal, H. S., Vassilevski, K., Jackson, A., Baker, S. N., & O’Neill, A. (2016) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2016.00005 · Cited by 4
“ecording data is lacking. Most of the current flexible devices seem to develop issues, especially for interfacing > 1 year. For example, polyimide has been used extensively for flexible electrodes [8,9], however it suffers from pin-hole development, which will lead to subsequent in-vivo device delamination through…”
Background
Metadata
- Authors
- Stieglitz, T., Schuettler, M., Rubehn, B., Boretius, T., Badia, J., & Navarro, X.
- Venue
- 2011 5th International IEEE/EMBS Conference on Neural Engineering
- Publisher
- IEEE
- Published
- 2011-04
- Pages
- 529-533
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2106592818
- Cited by
- 19
- References
- 15
- FWCI
- 3.64
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.