Retinal Imaging and Image Analysis
Open accessAbstract
Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distinctive Image Features from Scale-Invariant Keypoints
Lowe, D. G. (2004) · International Journal of Computer Vision · doi:10.1023/b:visi.0000029664.99615.94 · Cited by 55,589
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Russell, E. L., Chiang, L. H., & Braatz, R. D. (2000) · Advances in Industrial Control · doi:10.1007/978-1-4471-0409-4_3 · Cited by 7,862
A Taxonomy and Evaluation of Dense Two-Frame Stereo Correspondence Algorithms
Scharstein, D., & Szeliski, R. (2002) · International Journal of Computer Vision · doi:10.1023/a:1014573219977 · Cited by 6,740 · cited 1×
“A major inspiration for these online image databases and online competitions was the Middlebury Stereo Vision competition [101], [102].”
Ranibizumab for Neovascular Age-Related Macular Degeneration
Rosenfeld, P. J., Brown, D. M., Heier, J. S., Boyer, D. S., Kaiser, P. K., Chung, C. Y., & Kim, R. Y. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054481 · Cited by 5,886
Statistical and structural approaches to texture
Haralick, R. M. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11328 · Cited by 5,759
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Powell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632 · cited 1×
“As an example, the RADIC model [179] parameters are estimated during an optimization step that uses Powell’s method [180] and is driven by the vessel center line distance (see also Section IV-C).”
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
Porwal, P., Pachade, S., Kamble, R., Kokare, M., Deshmukh, G., Sahasrabuddhe, V., & Meriaudeau, F. (2018) · Data · doi:10.3390/data3030025 · Cited by 923
Orlando, J. I., Fu, H., Barbosa Breda, J., van Keer, K., Bathula, D. R., Diaz-Pinto, A., Fang, R., Heng, P.-A., Kim, J., Lee, J., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101570 · Cited by 855
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Trainable COSFIRE filters for vessel delineation with application to retinal images
Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.08.002 · Cited by 713
Sohn, E. H., van Dijk, H. W., Jiao, C., Kok, P. H. B., Jeong, W., Demirkaya, N., Garmager, A., Wit, F., Kucukevcilioglu, M., van Velthoven, M. E. J., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522014113 · Cited by 682
Self-citationDiabetic retinopathy detection through deep learning techniques: A review
Alyoubi, W. L., Shalash, W. M., & Abulkhair, M. F. (2020) · Informatics in Medicine Unlocked · doi:10.1016/j.imu.2020.100377 · Cited by 527
Deep image mining for diabetic retinopathy screening
Quellec, G., Charrière, K., Boudi, Y., Cochener, B., & Lamard, M. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.04.012 · Cited by 520
Aquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
Orlando, J. I., Prokofyeva, E., & Blaschko, M. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2535311 · Cited by 503
Fang, L., Cunefare, D., Wang, C., Guymer, R. H., Li, S., & Farsiu, S. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.002732 · Cited by 481
Computer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
van Grinsven, M. J. J. P., van Ginneken, B., Hoyng, C. B., Theelen, T., & Sanchez, C. I. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2526689 · Cited by 426
“As hemorrhages and micro-aneurysms are similar in characteristics and are only differentiable by their size and color on color fundus images, they can be easily confused [16].”
BackgroundRobust Retinal Vessel Segmentation via Locally Adaptive Derivative Frames in Orientation Scores
Zhang, J., Dashtbozorg, B., Bekkers, E., Pluim, J. P. W., Duits, R., & ter Haar Romeny, B. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2587062 · Cited by 417
Applications of deep learning in fundus images: A review
Li, T., Bo, W., Hu, C., Kang, H., Liu, H., Wang, K., & Fu, H. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.101971 · Cited by 396
IDRiD: Diabetic Retinopathy – Segmentation and Grading Challenge
Porwal, P., Pachade, S., Kokare, M., Deshmukh, G., Son, J., Bae, W., Liu, L., Wang, J., Liu, X., Gao, L., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101561 · Cited by 372
Hu, K., Zhang, Z., Niu, X., Zhang, Y., Cao, C., Xiao, F., & Gao, X. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.05.011 · Cited by 349
Blood Vessel Segmentation of Fundus Images by Major Vessel Extraction and Sub-Image Classification
Roychowdhury, S., Koozekanani, D., & Parhi, K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2335617 · Cited by 336
Christopher, M., Belghith, A., Bowd, C., Proudfoot, J. A., Goldbaum, M. H., Weinreb, R. N., Girkin, C. A., Liebmann, J. M., & Zangwill, L. M. (2018) · Scientific Reports · doi:10.1038/s41598-018-35044-9 · Cited by 328
“As opposed to traditional machine learning approaches that rely on features explicitly defined by experts using their domain knowledge 20–23 , CNNs are a type network that can learn features to maximize the network’s ability to distinguish between healthy and disease images.”
BackgroundAutomated identification and grading system of diabetic retinopathy using deep neural networks
Zhang, W., Zhong, J., Yang, S., Gao, Z., Hu, J., Chen, Y., & Yi, Z. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.03.016 · Cited by 311
Retinal vessel segmentation based on Fully Convolutional Neural Networks
Oliveira, A., Pereira, S., & Silva, C. A. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.06.034 · Cited by 299
Enhancement of Vascular Structures in3D and 2D Angiographic Images
Jerman, T., Pernus, F., Likar, B., & Spiclin, Z. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2550102 · Cited by 294
An ensemble deep learning based approach for red lesion detection in fundus images
Orlando, J. I., Prokofyeva, E., del Fresno, M., & Blaschko, M. B. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2017.10.017 · Cited by 293
Iterative Vessel Segmentation of Fundus Images
Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2403295 · Cited by 282
Retinal vessel segmentation via deep learning network and fully-connected conditional random fields
Fu, H., Xu, Y., Wong, D. W. K., & Liu, J. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493362 · Cited by 274
RETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
An ensemble-based system for automatic screening of diabetic retinopathy
Antal, B., & Hajdu, A. (2014) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.12.023 · Cited by 256
Identification of early pericyte loss and vascular amyloidosis in Alzheimer’s disease retina
Shi, H., Koronyo, Y., Rentsendorj, A., Regis, G. C., Sheyn, J., Fuchs, D.-T., Kramerov, A. A., Ljubimov, A. V., Dumitrascu, O. M., Rodriguez, A. R., et al. (2020) · Acta Neuropathologica · doi:10.1007/s00401-020-02134-w · Cited by 230
Verbraak, F. D., Abramoff, M. D., Bausch, G. C. F., Klaver, C., Nijpels, G., Schlingemann, R. O., & van der Heijden, A. A. (2019) · Diabetes Care · doi:10.2337/dc18-0148 · Cited by 115
Lim, G., Bellemo, V., Xie, Y., Lee, X. Q., Yip, M. Y. T., & Ting, D. S. W. (2020) · Eye and Vision · doi:10.1186/s40662-020-00182-7 · Cited by 96
“Fundus imaging is defined as the process whereby reflected light is used to form a two dimensional representation of the three dimensional retina, the semi-transparent, layered tissue lining the interior of the eye projected onto an imaging plane [45].”
BackgroundContemporary retinal imaging techniques in diabetic retinopathy: a review
Cole, E. D., Novais, E. A., Louzada, R. N., & Waheed, N. K. (2016) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.12711 · Cited by 91
Automated and computer-assisted detection, classification, and diagnosis of diabetic retinopathy
Abràmoff, M. D., Leng, T., Ting, D. S. W., Rhee, K., Horton, M. B., Brady, C. J., & Chiang, M. F. (2020) · Telemedicine and e-Health · doi:10.1089/tmj.2020.0008 · Cited by 30
Self-citationAydin, B. A., Hussain, M., Hill, R., & Al-Aqrabi, H. (2023) · 2023 9th International Conference on Information Technology Trends (ITT) · doi:10.1109/itt59889.2023.10184244 · Cited by 9
“In developed countries, Diabetic Retinopathy (DR) is the main reason for visual impairment among people who are of working age [2,3].”
Background
Metadata
- Authors
- Abramoff, M. D., Garvin, M. K., & Sonka, M.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2010
- Volume
- 3
- Pages
- 169-208
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2100756624
- Cited by
- 1,439
- References
- 122
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.