The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants
Abstract
Resonance-based wireless power delivery is an efficient technique to transfer power over a relatively long distance. This technique typically uses four coils as opposed to two coils used in conventional inductive links. In the four-coil system, the adverse effects of a low coupling coefficient between primary and secondary coils are compensated by using high-quality (Q) factor coils, and the efficiency of the system is improved. Unlike its two-coil counterpart, the efficiency profile of the power transfer is not a monotonically decreasing function of the operating distance and is less sensitive to changes in the distance between the primary and secondary coils. A four-coil energy transfer system can be optimized to provide maximum efficiency at a given operating distance. We have analyzed the four-coil energy transfer systems and outlined the effect of design parameters on power-transfer efficiency. Design steps to obtain the efficient power-transfer system are presented and a design example is provided. A proof-of-concept prototype system is implemented and confirms the validity of the proposed analysis and design techniques. In the prototype system, for a power-link frequency of 700 kHz and a coil distance range of 10 to 20 mm, using a 22-mm diameter implantable coil resonance-based system shows a power-transfer efficiency of more than 80% with an enhanced operating range compared to ~40% efficiency achieved by a conventional two-coil system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Efficient wireless non-radiative mid-range energy transfer
Karalis, A., Joannopoulos, J. D., & Soljačić, M. (2008) · Annals of Physics · doi:10.1016/j.aop.2007.04.017 · Cited by 1,394
Haus, H. A., & Huang, W. (1991) · Proceedings of the IEEE · doi:10.1109/5.104225 · Cited by 992
Cannon, B. L., Hoburg, J. F., Stancil, D. D., & Goldstein, S. C. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2017195 · Cited by 924
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Low, Z. N., Chinga, R. A., Tseng, R., & Lin, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2010110 · Cited by 528
Geometric approach for coupling enhancement of magnetically coupled coils
Zierhofer, C. M., & Hochmair, E. S. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.503178 · Cited by 420
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure
Soma, M., Galbraith, D. C., & White, R. L. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326088 · Cited by 265
Designing Efficient Inductive Power Links for Implantable Devices
Harrison, R. R. (2007) · 2007 IEEE International Symposium on Circuits and Systems (ISCAS) · doi:10.1109/iscas.2007.378508 · Cited by 244
Research works printed but not linked: 15
- 2005, New England Wire Technologies Litz Wire Technical pdf
- 10.1109/15.917948 · doi:10.1109/15.917948
- grandi, 1996, Stray capacitances of single-layer air-core inductors for high-frequency applications, Proc IEEE Industry Applications Conf, 1384
- 2005, New England Wire Technologies Litz Wire Product
- 10.1109/PESC.1996.548808 · doi:10.1109/pesc.1996.548808
- soma, 1975, transmission of time varying magnetic field through body tissue, J Biol Phys, 3, 95, 10.1007/BF02309611 · doi:10.1007/bf02309611
- 10.1109/IEMBS.1995.579873 · doi:10.1109/iembs.1995.579873
- 10.1109/ICMA.2007.4304140 · doi:10.1109/icma.2007.4304140
- 10.1007/s10544-007-9113-z · doi:10.1007/s10544-007-9113-z
- 10.1049/iet-nbt:20070022 · DOI
- 10.1109/IEMBS.2007.4353657 · doi:10.1109/iembs.2007.4353657
- 10.1109/BIOCAS.2008.4696884 · doi:10.1109/biocas.2008.4696884
- liu, 2009, Wireless power transfer system design for implanted and worn devices, Proc IEEE 30th Annual Northeast on Bioengineering Conf, 1
- zhu, 2008, Simulation and experimental analysis on wireless energy transfer based on magnetic resonances, Proc IEEE Vehicle Power and Propulsion Conf, 1
- malmivuo, 2004, Bioelectromagn
Cited by
A Critical Review of Recent Progress in Mid-Range Wireless Power Transfer
Hui, S. Y. R., Zhong, W., & Lee, C. K. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2249670 · Cited by 1,465
Wireless Charging Technologies: Fundamentals, Standards, and Network Applications
Lu, X., Wang, P., Niyato, D., Kim, D. I., & Han, Z. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2499783 · Cited by 968
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Communications and Signals Design for Wireless Power Transmission
Zeng, Y., Clerckx, B., & Zhang, R. (2017) · IEEE Transactions on Communications · doi:10.1109/tcomm.2017.2676103 · Cited by 463
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
The Circuit Theory Behind Coupled-Mode Magnetic Resonance-Based Wireless Power Transmission
Kiani, M., & Ghovanloo, M. (2012) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2180446 · Cited by 421
Effect of Coupling Between Multiple Transmitters or Multiple Receivers on Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196902 · Cited by 382
Berger, A., Agostinelli, M., Vesti, S., Oliver, J. A., Cobos, J. A., & Huemer, M. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2410216 · Cited by 365
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“efficiency and reduced dependence of the latter on the distance between the primary and secondary coils [90].”
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
“In [67,140,141] and [137,142], L is calculated using Equations (6) and (8), and Mij is determined using (9) and (11).”
BackgroundMethodInfluentialA Study on Magnetic Field Repeater in Wireless Power Transfer
Ahn, D., & Hong, S. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2188254 · Cited by 351
Maximum Achievable Efficiency in Near-Field Coupled Power-Transfer Systems
Zargham, M., & Gulak, P. G. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174794 · Cited by 349
Modeling of Mutual Coupling Between Planar Inductors in Wireless Power Applications
Raju, S., Wu, R., Chan, M., & Yue, C. P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2253334 · Cited by 343
Xue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Li, W., Zhao, H., Li, S., Deng, J., Kan, T., & Mi, C. C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2384003 · Cited by 331
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
A Figure-of-Merit for Designing High-Performance Inductive Power Transmission Links
Kiani, M., & Ghovanloo, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2227914 · Cited by 146
Recent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
“This efficient approach allows one to transfer power over longer distances using a four-coil coupling system in which the adverse effects resulting from a low coupling coefficient between the primary coil and the secondary coil can be compensated by using high-quality factor coils [87].”
MethodZargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
Midfield Wireless Powering of Subwavelength Autonomous Devices
Kim, S., Ho, J. S., & Poon, A. S. Y. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.203905 · Cited by 110
Wireless power transfer system with high misalignment tolerance for bio-medical implants
Wang, Q., Che, W., Mongiardo, M., & Monti, G. (2020) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2020.2985056 · Cited by 83
“Firstly, a standard four-coil WPT link operating in air at 40MHz was designed by using the procedure described in [2], [9].”
MethodHigh-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
EnerCage: A Smart Experimental Arena With Scalable Architecture for Behavioral Experiments
Jow, U.-M., McMenamin, P., Kiani, M., Manns, J. R., & Ghovanloo, M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2278180 · Cited by 62
Lyu, H., Wang, J., La, J.-H., Chung, J. M., & Babakhani, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2852680 · Cited by 47
Capacitive power transfer in biomedical implantable device: a review
Mustapa, M. Z. B., Saat, S., Yusof, Y., & Shaari, M. M. (2019) · International Journal of Power Electronics and Drive Systems (IJPEDS) · doi:10.11591/ijpeds.v10.i2.pp935-942 · Cited by 18
Study of midfield wireless power transfer for implantable medical devices
Keerthi., K. S., Ilango., K., & Manjula., G. N. (2018) · 2018 2nd International Conference on Biomedical Engineering (IBIOMED) · doi:10.1109/ibiomed.2018.8534820 · Cited by 17
Metadata
- Authors
- RamRakhyani, A. K., Mirabbasi, S., & Chiao, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2011-02
- Volume
- 5
- Issue
- 1
- Pages
- 48-63
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2160400740
- Cited by
- 945
- References
- 27
- FWCI
- 35.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.