The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Advancements in Noncontact, Multiparameter Physiological Measurements Using a Webcam
Abstract
We present a simple, low-cost method for measuring multiple physiological parameters using a basic webcam. By applying independent component analysis on the color channels in video recordings, we extracted the blood volume pulse from the facial regions. Heart rate (HR), respiratory rate, and HR variability (HRV, an index for cardiac autonomic activity) were subsequently quantified and compared to corresponding measurements using Food and Drug Administration-approved sensors. High degrees of agreement were achieved between the measurements across all physiological parameters. This technology has significant potential for advancing personal health care and telemedicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Independent component analysis, A new concept?
Comon, P. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90029-9 · Cited by 8,205
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Remote plethysmographic imaging using ambient light
Verkruysse, W., Svaasand, L. O., & Nelson, J. S. (2008) · Optics Express · doi:10.1364/oe.16.021434 · Cited by 1,719
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Self-citationHigh-Order Contrasts for Independent Component Analysis
Cardoso, J.-F. (1999) · Neural Computation · doi:10.1162/089976699300016863 · Cited by 1,213
An advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Cited by
Algorithmic principles of remote PPG
Wang, W., den Brinker, A. C., Stuijk, S., & de Haan, G. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2609282 · Cited by 1,234
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“The results verify its effectiveness for removing noise [45,46].”
BackgroundIntroducing the RECOLA multimodal corpus of remote collaborative and affective interactions
Ringeval, F., Sonderegger, A., Sauer, J., & Lalanne, D. (2013) · 2013 10th IEEE International Conference and Workshops on Automatic Face and Gesture Recognition (FG) · doi:10.1109/fg.2013.6553805 · Cited by 771
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
DeepPhys: Video-Based Physiological Measurement Using Convolutional Attention Networks
Chen, W., & McDuff, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01216-8_22 · Cited by 716
Self-citationUnsupervised skin tissue segmentation for remote photoplethysmography
Bobbia, S., Macwan, R., Benezeth, Y., Mansouri, A., & Dubois, J. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2017.10.017 · Cited by 615
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Remote Heart Rate Measurement from Face Videos under Realistic Situations
Li, X., Chen, J., Zhao, G., & Pietikainen, M. (2014) · 2014 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2014.543 · Cited by 550
Physiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
DistancePPG: Robust non-contact vital signs monitoring using a camera
Kumar, M., Veeraraghavan, A., & Sabharwal, A. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001565 · Cited by 417
RhythmNet: End-to-End Heart Rate Estimation From Face via Spatial-Temporal Representation
Niu, X., Shan, S., Han, H., & Chen, X. (2020) · IEEE Transactions on Image Processing · doi:10.1109/tip.2019.2947204 · Cited by 420
Diagnostic challenges in epilepsy: seizure under-reporting and seizure detection
Elger, C. E., & Hoppe, C. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30038-3 · Cited by 403
A Novel Algorithm for Remote Photoplethysmography: Spatial Subspace Rotation
Wang, W., Stuijk, S., & de Haan, G. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2508602 · Cited by 370
Tulyakov, S., Alameda-Pineda, X., Ricci, E., Yin, L., Cohn, J. F., & Sebe, N. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.263 · Cited by 340
Yu, Z., Peng, W., Li, X., Hong, X., & Zhao, G. (2019) · 2019 IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2019.00024 · Cited by 340
Measuring Emotions in Real Time: Implications for Tourism Experience Design
Kim, J. (., & Fesenmaier, D. R. (2015) · Journal of Travel Research · doi:10.1177/0047287514550100 · Cited by 335
Automated Detection of Engagement Using Video-Based Estimation of Facial Expressions and Heart Rate
Monkaresi, H., Bosch, N., Calvo, R. A., & D'Mello, S. K. (2017) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2016.2515084 · Cited by 329
Non-contact heart rate and heart rate variability measurements: A review
Kranjec, J., Beguš, S., Geršak, G., & Drnovšek, J. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2014.03.004 · Cited by 318
Remote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308
Self-citationPhysFormer: Facial Video-based Physiological Measurement with Temporal Difference Transformer
Yu, Z., Shen, Y., Shi, J., Zhao, H., Torr, P., & Zhao, G. (2022) · 2022 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr52688.2022.00415 · Cited by 300
Improvements in Remote Cardiopulmonary Measurement Using a Five Band Digital Camera
McDuff, D., Gontarek, S., & Picard, R. W. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2323695 · Cited by 287
Self-citationDeepRhythm: Exposing DeepFakes with Attentional Visual Heartbeat Rhythms
Qi, H., Guo, Q., Juefei-Xu, F., Xie, X., Ma, L., Feng, W., Liu, Y., & Zhao, J. (2020) · arXiv · doi:10.48550/arxiv.2006.07634 · Cited by 280
DeepRhythm: Exposing DeepFakes with Attentional Visual Heartbeat Rhythms
Qi, H., Guo, Q., Juefei-Xu, F., Xie, X., Ma, L., Feng, W., Liu, Y., & Zhao, J. (2020) · Proceedings of the 28th ACM International Conference on Multimedia · doi:10.1145/3394171.3413707 · Cited by 220
Security Tradeoffs in Cyber Physical Systems: A Case Study Survey on Implantable Medical Devices
Altawy, R., & Youssef, A. M. (2016) · IEEE Access · doi:10.1109/access.2016.2521727 · Cited by 139
A data set of real world driving to assess driver workload
Schneegass, S., Pfleging, B., Broy, N., Heinrich, F., & Schmidt, A. (2013) · Proceedings of the 5th International Conference on Automotive User Interfaces and Interactive Vehicular Applications · doi:10.1145/2516540.2516561 · Cited by 135
COGCAM: Contact-free Measurement of Cognitive Stress During Computer Tasks with a Digital Camera
McDuff, D. J., Hernandez, J., Gontarek, S., & Picard, R. W. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858247 · Cited by 113
Self-citationAutoEmotive: bringing empathy to the driving experience to manage stress
Hernandez, J., McDuff, D., Benavides, X., Amores, J., Maes, P., & Picard, R. (2014) · Proceedings of the 2014 companion publication on Designing interactive systems · doi:10.1145/2598784.2602780 · Cited by 79
Self-citationNowara, E. M., McDuff, D., & Veeraraghavan, A. (2020) · 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw50498.2020.00150 · Cited by 66
Self-citationYan, B. P., Chan, C. K., Li, C. K., To, O. T., Lai, W. H., Tse, G., Poh, Y. C., & Poh, M.-Z. (2017) · JMIR mHealth and uHealth · doi:10.2196/mhealth.7275 · Cited by 50
Self-citationNon-Contact Vital Signs Monitoring of Dog and Cat Using a UWB Radar
Wang, P., Ma, Y., Liang, F., Zhang, Y., Yu, X., Li, Z., An, Q., Lv, H., & Wang, J. (2020) · Animals · doi:10.3390/ani10020205 · Cited by 45
Photoplethysmogram-based Cognitive Load Assessment Using Multi-Feature Fusion Model
Zhang, X., Lyu, Y., Qu, T., Qiu, P., Luo, X., Zhang, J., Fan, S., & Shi, Y. (2019) · ACM Transactions on Applied Perception · doi:10.1145/3340962 · Cited by 28
Imaging Photoplethysmography: What are the Best Locations on the Face to Estimate Heart Rate?
Fallet, S., Moser, V., Braun, F., & Vesin, J.-M. (2016) · 2016 Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2016.098-236 · Cited by 28
Beyond Mobile Apps: A Survey of Technologies for Mental Well-Being
Woodward, K., Kanjo, E., Brown, D. J., McGinnity, T. M., Inkster, B., Macintyre, D. J., & Tsanas, A. (2022) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2020.3015018 · Cited by 18
PhysFlow: Skin tone transfer for remote heart rate estimation through conditional normalizing flows
Comas, J., Alomar, A., Ruiz, A., & Sukno, F. (2024) · arXiv · doi:10.48550/arxiv.2407.21519 · Cited by 4
“Some focus on regions of interest, employing techniques like Blind Source Separation [25, 43, 44], Normalized Least Mean Squares [26], or self-adaptive matrix completion [55].”
MethodMultimodal Observation and Interpretation of Subjects Engaged in Problem Solving
Guntz, T., Balzarini, R., Vaufreydaz, D., & Crowley, J. L. (2017) · arXiv · doi:10.48550/arxiv.1710.04486 · Cited by 4
Metadata
- Authors
- Poh, M.-Z., McDuff, D. J., & Picard, R. W.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-01
- Volume
- 58
- Issue
- 1
- Pages
- 7-11
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2008821584
- Cited by
- 1,486
- References
- 20
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.