Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We have demonstrated that micro-channel electrode arrays with 100 microm x 100 microm cross-section channels support axon regeneration well, and that micro-channels of similar calibre and up to 5 mm long can support axon regeneration and vascularisation. They may be microfabricated using silicon, silicone, or polyimide and thin metal films to form 3-D bundles of long micro-channels. Arrays of "mini-nerves," i.e., miniature nerve fascicles with their own blood vessels, successfully grew through implants 0.5-5 mm long. Furthermore, guiding the regenerating nerve fibres into the small insulating channels allows for a significant increase of the extracellular (recordable) amplitude of action potentials, which promises considerable improvement for in vivo electrophysiology.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“While axon regeneration can occur in microchannel devices with channels as small as small as 55 μm in diameter (similar to sieve electrode dimensions), optimal axon regeneration is seen when coupled with growth of one or more blood vessel, requiring larger microchannels of 100 μm diameter (Lacour et al., 2009).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Lacour et al., 2009
In the citing paper
“The MCEA device allowed for the regeneration of miniature nerve fascicles up to 5 mm long with their own vascular structures to grow through the implanted device.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [30]
In the citing paper
“These fascicles within the MCEA maintained a similar structure and function to nerves regenerated through an ordinary silicone tube.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [30]
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Self-citationNerve regeneration through artificial tubular implants
Fields, R. D., Le Beau, J. M., Longo, F. M., & Ellisman, M. H. (1989) · Progress in Neurobiology · doi:10.1016/0301-0082(89)90036-1 · Cited by 308 · cited 1×
“This is a typical observation of a nerve regenerating through a tube [ 12 ].”
BackgroundA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · cited 1×
“Current interfaces typically have tens (sieve electrodes) [2]–[4] to a hundred or so (Utah pin arrays) electrodes [5].”
BackgroundCuff electrodes for chronic stimulation and recording of peripheral nerve activity
Loeb, G. E., & Peck, R. A. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00123-9 · Cited by 215 · cited 1×
“We have overcome this by guiding the axons into small micro-channels made of insulating material: the micro-channel restricts the extracellular space, augmenting the resulting extracellular impedance thus increasing the recordable amplitude of the action potential [6], [7].”
BackgroundLago, N., Ceballos, D., J Rodrı́guez, F., Stieglitz, T., & Navarro, X. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.025 · Cited by 178
Self-citationStieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125
Numbers of regenerating axons in parent and tributary peripheral nerves in the rat
Jenq, C., & Coggeshall, R. E. (1985) · Brain Research · doi:10.1016/0006-8993(85)91381-2 · Cited by 123 · cited 2×
“uninjured sciatic nerves contained an average of 7,395 26 myelinated fibres ; nerves regenerated through 3 mm gap silicone tube had an average of 7494 MF [13].”
BackgroundAssessment of the biocompatibility of photosensitive polyimide for implantable medical device use
Sun, Y., Lacour, S. P., Brooks, R. A., Rushton, N., Fawcett, J., & Cameron, R. E. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32125 · Cited by 122
Self-citationMicrochannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · cited 2×
“For example, single-unit extracellular voltage swings of up to 500 can be recorded by the midpoint electrode in a 90- -diameter, 1-cm-long channel [7].”
BackgroundSelf-citationPolyimide micro-channel arrays for peripheral nerve regenerative implants
Lacour, S. P., Atta, R., FitzGerald, J. J., Blamire, M., Tarte, E., & Fawcett, J. (2008) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2008.05.031 · Cited by 56
Self-citation
Cited by
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“This is, however, followed by a sharp decline in axon numbers at the 12 month time point (Lago et al., 2005).”
BackgroundFlexible and stretchable micro-electrodes for in vitro and in vivo neural interfaces
Lacour, S. P., Benmerah, S., Tarte, E., FitzGerald, J., Serra, J., McMahon, S., Fawcett, J., Graudejus, O., Yu, Z., & Morrison, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0644-8 · Cited by 263
“Robust vascularisation is observed through most micro-channels [ 21 ].”
BackgroundMethodInfluentialSelf-citationPast, Present, and Future of Nerve Conduits in the Treatment of Peripheral Nerve Injury
Muheremu, A., & Ao, Q. (2015) · BioMed Research International · doi:10.1155/2015/237507 · Cited by 199
“Bioabsorbable and compound conduits (consisting of neurotrophic factors [63], nerve supporters [64, 65], SCs [66], and neural stem cells [67–69]) have promoted chemotactic regeneration of peripheral nerves and enhanced the effectiveness of nerve repair.”
BackgroundSafety of long-term electrical peripheral nerve stimulation: review of the state of the art
Günter, C., Delbeke, J., & Ortiz-Catalan, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0474-8 · Cited by 198
The biophysics of neuronal growth
Franze, K., & Guck, J. R. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/9/094601 · Cited by 182
Lee, S., Wang, H., Shi, Q., Dhakar, L., Wang, J., Thakor, N. V., Yen, S.-C., & Lee, C. (2017) · Nano Energy · doi:10.1016/j.nanoen.2016.12.038 · Cited by 148
The foreign body response to the Utah Slant Electrode Array in the cat sciatic nerve
Christensen, M. B., Pearce, S. M., Ledbetter, N. M., Warren, D. J., Clark, G. A., & Tresco, P. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.010 · Cited by 135
A Microchannel Neuroprosthesis for Bladder Control After Spinal Cord Injury in Rat
Chew, D. J., Zhu, L., Delivopoulos, E., Minev, I. R., Musick, K. M., Mosse, C. A., Craggs, M., Donaldson, N., Lacour, S. P., McMahon, S. B., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007186 · Cited by 123
Self-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Goding, J. A., Gilmour, A. D., Robles, U. A. A., Hasan, E. A., & Green, R. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702969 · Cited by 95
Selective stimulation and neural recording on peripheral nerves using flexible split ring electrodes
Lee, S., Sheshadri, S., Xiang, Z., Delgado-Martinez, I., Xue, N., Sun, T., Thakor, N. V., Yen, S.-C., & Lee, C. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.09.127 · Cited by 73
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Self-citationGribi, S., du Bois de Dunilac, S., Ghezzi, D., & Lacour, S. P. (2018) · Nature Communications · doi:10.1038/s41467-018-06895-7 · Cited by 72
Self-citationThe promotion of axon extension in vitro using polymer-templated fibrin scaffolds
Scott, J. B., Afshari, M. J., Kotek, R., & Saul, J. M. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.037 · Cited by 72
“Several methods of incorporating physical cues into scaffolds exist, including (1) alignment of fiber bundles [21,23] and formation of alignedmulti-luminal constructs via (2) sacrificial templating [26,29], (3) phase separation [37], (4) lithography [38,39], and (5) solid free-form fabrication [40].”
MethodRochford, A. E., Carnicer‐Lombarte, A., Kawan, M., Jin, A. T., Hilton, S., Curto, V. F., Rutz, A. L., Moreau, T., Kotter, M., Malliaras, G. G., et al. (2023) · Science Advances · doi:10.1126/sciadv.add8162 · Cited by 69
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68
Self-citationRegenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
“29,30 The MCEA device is created by rolling a planar sheet of polyimide microchannels with individual * 100 · 100 m m cross-sectional areas into a cylindrical tube structure.”
Microchannel-based regenerative scaffold for chronic peripheral nerve interfacing in amputees
Srinivasan, A., Tahilramani, M., Bentley, J. T., Gore, R. K., Millard, D. C., Mukhatyar, V. J., Joseph, A., Haque, A. S., Stanley, G. B., English, A. W., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.11.035 · Cited by 67
“It is also important to note that these trends of regeneration and dependence onmicrochannel size agree well with other studies looking at non-amputee scenarios [13,30].”
Motor-commands decoding using peripheral nerve signals: a review
Hong, K.-S., Aziz, N., & Ghafoor, U. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab383 · Cited by 63
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“As a result, these polymers have been used in recent decades to develop extraneural [186, 200, 201], intraneural [80, 112, 116, 202] and regenerative [123, 203, 204] devices alike.”
BackgroundSelf-citationBiophysics of microchannel-enabled neuron–electrode interfaces
Wang, L., Riss, M., Buitrago, J. O., & Claverol-Tinturé, E. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026010 · Cited by 61
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 60
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1429-x · Cited by 54
“[75] developed a microchannel nerve interface which separated nerve fibers by promoting their growth into individual microchannels.”
BackgroundCurrent and emerging strategies for biocompatible materials for implantable electronics
Zhou, Y., Morris, G. H. B., & Nair, M. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101852 · Cited by 53
Zamani, M., & Demosthenous, A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2309678 · Cited by 49
“One other type of nerve-electrode interface suitable for longterm use with peripheral nerves is the microchannel nerve interface [4].”
Adipose Derived Stem Cells Reduce Fibrosis and Promote Nerve Regeneration in Rats
Summa, P. G. D., Schiraldi, L., Cherubino, M., Oranges, C. M., Kalbermatten, D. F., Raffoul, W., & Madduri, S. (2018) · The Anatomical Record · doi:10.1002/ar.23841 · Cited by 39
“Nerve fibrosis and scarring have been detected when the nerve needs to grow through nonresorbable guides, especially in microchannel (FitzGerald et al., 2012) devices intended for electrophysiological recording (Lacour et al., 2009).”
Backgroundde la Oliva, N., Navarro, X., & del Valle, J. (2018) · The Anatomical Record · doi:10.1002/ar.23920 · Cited by 37
“We also tested the effects of systemic dexamethasone administration on the FBR to intraneural implants made of polyimide, another polymer used as electrode substrate (Rodriguez et al., 2000; Lacour et al., 2009; Lago et al., 2007).”
BackgroundMinev, I. R., Chew, D. J., Delivopoulos, E., Fawcett, J. W., & Lacour, S. P. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026005 · Cited by 36
“It has been shown that parallel channels up to 5 mm long and with a 10 000 μm2 cross-sectional area support in vivo regeneration well [24].”
BackgroundSelf-citationPrintable microscale interfaces for long-term peripheral nerve mapping and precision control
Otchy, T. M., Michas, C., Lee, B., Gopalan, K., Nerurkar, V., Gleick, J., Semu, D., Darkwa, L., Holinski, B. J., Chew, D. J., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18032-4 · Cited by 35
Fascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35
Flexible epineural strip electrode for recording in fine nerves
Lee, S., Yen, S.-C., Sheshadri, S., Martinez, I. D., Xue, N., Xiang, Z., Thakor, N. V., & Lee, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466442 · Cited by 33
Sands, I., DeMarco, R. E., Thurber, L., Esteban‐Linares, A., Song, D. B., Meng, E. F., & Chen, Y. (2024) · Advanced Materials · doi:10.1002/adma.202401750 · Cited by 33
Criales, L. E., Orozco, P. F., Medrano, A., Rodriguez, C. A., & Özel, T. (2015) · Materials and Manufacturing Processes · doi:10.1080/10426914.2015.1004690 · Cited by 33
“Its applications include: lab-on-a-chip devices [12, 13], DNA analysis [14, 15], drug delivery devices [14], nerve regeneration [16], microfluidic chip devices [17], and many others [18].”
BackgroundDifferences Exist in the Left and Right Sciatic Nerves of Naïve Rats and Cats
Christensen, M. B., & Tresco, P. A. (2015) · The Anatomical Record · doi:10.1002/ar.23161 · Cited by 32
“…2005a,b) and sieve or regenerating electrodes (Klinge et al., 2001; Ceballos et al., 2002; Lago et al., 2005; Castro et al., 2008; Kim et al., 2009; Lacour et al., 2009), whereas the cat sciatic nerve is also commonly used in nerve cuff electrode studies (Stein et al., 1977; Hoffer et al., 1981;…”
MethodStieglitz, T., Schuettler, M., Rubehn, B., Boretius, T., Badia, J., & Navarro, X. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910602 · Cited by 19
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1452-6 · Cited by 24
Lim, J., Zoss, P., Powley, T. L., Lee, H., & Ward, M. P. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00637-6 · Cited by 20
“Microchannel electrode devices normally feature channel structures with micro-meter scale dimensions (50 – 100 µm of channel width and height) and array(s) of electrodes embedded in each channel to interface with a fi nite bundle of nerve fi bers that are separately placed in each channel 22 – 28 .”
BackgroundMethodInfluentialCoker, R., Zellmer, E. R., & Moran, D. W. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaefab · Cited by 16
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces
Lancashire, H. T., Jiang, D., Demosthenous, A., & Donaldson, N. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891284 · Cited by 15
“approximately 100 μmbecause smaller diameter microchannels become occluded with fibrotic tissue [23].”
BackgroundMethodGonzález-Prieto, J., Cristóbal, L., Arenillas, M., Giannetti, R., Frías, J. D. M., Rivas, E. A., Barbero, E. S., Gutiérrez-Pecharromán, A., Montero, F. D., & Maldonado, A. A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25021141 · Cited by 15
“The assessment of tissue viability in RPNIs yielded satisfactory results in all of these eighteen articles [1,9,10,13,15,23,24,26,30,31,35,38,41,44,46–48 , 62 The evaluation of muscular neoangiogenesis in RPNIs reveals robust outcomes in the fourteen studies where it was assessed through a…”
BackgroundResultInfluentialElastic components for prosthetic skin
Lacour, S. P., Graz, I. M., Cotton, D. P. J., Bauer, S., & Wagner, S. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6092065 · Cited by 14
Self-citationWatling, C. P., Lago, N., Benmerah, S., FitzGerald, J. J., Tarte, E. J., McMahon, S. B., Lacour, S. P., & Cameron, R. E. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.032 · Cited by 15
Self-citationBenmerah, S., Lacour, S. P., & Tarte, E. J. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333723 · Cited by 14
Self-citationMicrochannel neural interface manufacture by stacking silicone and metal foil laminae
Lancashire, H. T., Vanhoestenberghe, A., Pendegrass, C. J., Ajam, Y. A., Magee, E., Donaldson, N., & Blunn, G. W. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/034001 · Cited by 13
“It must be noted that the in vivo evaluation in this paper used larger microchannels (200 μm) with electrode present in two microchannels, and that neural regeneration is better through larger microchannels [5].”
BackgroundMethodCoker, R., Zellmer, E. R., & Moran, D. W. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaefcf · Cited by 12
Fully 3D‐Printed Cuff Electrode for Small Nerve Interfacing
Zurita, F., Grob, L., Erben, A., Duca, F. D., Clausen‐Schaumann, H., Sudhop, S., Hayden, O., & Wolfrum, B. L. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200989 · Cited by 12
Zellmer, E. R., MacEwan, M. R., & Moran, D. W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9e96 · Cited by 12
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“Regenerative: ( e ) sieve [30], microchannel [34], and ( f ) scaffold [32] electrodes.”
Handcrafted multilayer PDMS microchannel scaffolds for peripheral nerve regeneration
Hossain, R. F., Kim, B., Pankratz, R., Ajam, A., Park, S., Biswal, S. L., & Choi, Y. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-0012-4 · Cited by 10
“Unlike autografting, it does not require the sacrifice of the donor sural nerve (Clements et al. 2009; Lacour et al. 2009; Lundborg et al. 1982b; Tansey et al. 2011).”
BackgroundInfluentialEvaluation of negative photo-patternable PDMS for the encapsulation of neural electrodes
Delivopoulos, E., Minev, I. R., & Lacour, S. P. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910593 · Cited by 8
“Silicones are 2-4 orders of magnitude softer than silicon, can be machined to conform threedimensional neural tissue [1, 2] and may reduce tissue scaring.”
BackgroundSelf-citationPDMS microchannel regenerative peripheral nerve interface
Musick, K. M., Chew, D. J., Fawcett, J. W., & Lacour, S. P. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696018 · Cited by 7
“Previously, sciatic nerve regeneration has been achieved through long microchannel arrays containing electrodes on a polyimide substrate [4].”
BackgroundSelf-citationSpiral peripheral nerve interface; updated fabrication process of the regenerative implant
Barrett, R., Benmerah, S., Frommhold, A., & Tarte, E. J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609614 · Cited by 5
Self-citationRegenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_18-1 · Cited by 5
Salman, I. M. (2023) · Hypertension Research · doi:10.1038/s41440-023-01486-6 · Cited by 4
“…[102] Self-opening intraneural electrodes [103] Carbon fi ber electrodes [104] Regenerative Sieve electrodes [105] Microchannel electrodes [106] Regenerative multielectrode interfaces [107] Tissue-engineered electronic nerve interfaces [108] Extraneural Split or spiral nerve cuffs [109]…”
High-fidelity interfacing for bionic rehabilitation
Vujaklija, I. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-23987-8.00003-1 · Cited by 3
NOVEL PROCESSING ROUTES FOR NEURAL INTERFACES
Barrett, R. C. (2014) · University of Birmingham Institutional Research Archive (University of Birmingham) · doi:10.13140/2.1.1683.2647 · Cited by 3
Biological response to implanted intraneural electrodes
de la Oliva, N. (2018) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 3
High-Porosity Sieve-Type Neural Electrodes for Motor Function Recovery and Nerve Signal Acquisition
Choi, W., Park, H., Oh, S., Seok, S., Yoon, D. S., & Kim, J. (2024) · Micromachines · doi:10.3390/mi15070862 · Cited by 2
“…microelectrode channels, achieves higher spatial resolution and better nerve interfacing, but its increased complexity and potential for greater nerve damage during implantation are drawbacks [35]. increased complexity and potential for greater nerve damage during implantation are drawbacks [35].”
BackgroundPeripheral nerve regeneration monitoring using multilayer microchannel scaffolds
Choi, Y., & Noh, H. “. (2016) · Neural Regeneration Research · doi:10.4103/1673-5374.179052 · Cited by 2
“Although microchannel scaffolds have been used successfully in several nerve regeneration studies on rats and other small mammals (Lacour et al., 2009; Billiar et al., 2010), the details of the biological events during axonal regeneration have not been reported.”
Development of a Neural Interface for PNS Motor Control
Christopher, G., Melinda, K. S., Luo, V. M., Jeffrey, D., & Bonnie, L. F. (2011) · InTech eBooks · doi:10.5772/23896 · Cited by 2
“Problems with this type of interface are currently being addressed by redesigning the recording sites to be tubular rather than planar [63-66].”
BackgroundTripolar interfaces for neural recording
Donaldson, N. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.3.359 · Cited by 2
High density penetrating electrode arrays for autonomic nerves
Burns, J., Hsieh, Y., Mueller, A. J., Chevallier, J., Sriram, T. S., Lewis, S. J., Chew, D. J., Achyuta, A. K. H., & Fiering, J. O. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591312 · Cited by 2
“μm diameter channels [7], and provide a high-density interface.”
BackgroundBiomedical Strategies for Axonal Regeneration
Saxena, T. K., Gilbert, R. J., Pai, B. S., & Bellamkonda, R. V. (2011) · Wiley eBooks · doi:10.1002/9780470015902.a0001110.pub2 · Cited by 2
Regenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_18 · Cited by 1
Li, M., Ly, C. M., Wen, J., Rustogi, P., & Meng, E. F. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00199-0 · Cited by 1
“Although planar microfabrication processes generally restrict channels to rectangular cross sections, one report suggests that shape may play an important role as the rectangular cross section was associated with more fibrous tissue (Lacour et al. 2009).”
Regenerative Neural Electrodes
Guzman, G., Rafaqut, M. S., Park, S., & Choi, P. Y. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_11 · Cited by 1
Özel, T., Ciurana, J., Teixidor, D., & Criales, L. E. (2016) · Wiley eBooks · doi:10.1002/9781119267034.ch4 · Cited by 1
Nanotexturisation of gold surfaces and its application to neural implants
Frommhold, A. (2011) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Zellmer, E. R. (2014) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k7ww7fnt
A neuromuscular junction-based neural interface
Langhammer, C. G. (2010) · Rutgers University Community Repository (Rutgers University) · doi:10.7282/t3cc10d2
“myotubes onto which PNS axons had successfully regenerated would solve the problems associated with recording from peripheral motor axons because of their small size [45, 227], inducing and maintaining neurite ingrowth into regenerative electrodes [43, 48], and isolation of a large number of motor signals from other n…”
BackgroundTowards a biodegradable, electro-active nerve repair conduit
Martin, C., Déjardin, T., Hart, A. M., Riehle, M. O., & Cumming, D. R. S. (2015) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2015.7184981
“These include mechanical guidance cues [3]–[5], fibrous conduits [6], [7], Schwann cell addition for enhanced proliferation [8], targeted growth-factor release [9] and the addition of a donor nerve (harvested from elsewhere in the body) [10].”
BackgroundDevelopment of a bioelectric nerve conduit using solenoid technology, and nano fabrication
Martin, C. (2013) · Enlighten: Theses (The University of Glasgow)
Scott, J. B. (2015) · WakeSpace Scholarship (Wake Forest University)
Coker, R. (2017) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/k7sj1k09
Design and fabrication of a next generation regenerative neural interface
Churm, J. (2018) · University of Birmingham Institutional Research Archive (University of Birmingham)
Sergi, P. N., Jensen, W., Yoshida, K., & Micera, S. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_25
Direct stimulation of peripheral nerves to provide sensory feedback
Günter, C. (2019) · Chalmers Publication Library (Chalmers University of Technology)
Sinthia, P., Mary, J. A. J., & Priyanka, M. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-7289-9_20
Santos, D. V. V., Navarro, X., Cel·lular, D. F. I. D. U. A. D. B. D. D. B., & de Neurociències, U. A. D. B. I. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
González-Prieto, J., Arenillas, M., Barbero, E. S., Pecharromán, A. G., Muñoz, J. D., Rivas, E. A., Morillo, M. D. C., Cristóbal, L., Giannetti, R., & Maldonado, A. A. (2026) · Journal of Translational Medicine · doi:10.1186/s12967-026-08453-y
Neurorobotics for Neurorehabilitation: Clinical Applications and Future Research Direction
Brossy, T., Katic, N., & Raspopović, S. (2026) · Springer eBooks · doi:10.1007/978-981-96-7448-0_35-1
Metadata
- Authors
- Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J.
- Affiliations
- University of Cambridge (GB)
- King's College London (GB)
- University of Birmingham (GB)
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2009-10
- Volume
- 17
- Issue
- 5
- Pages
- 454-460
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2139282950
- Cited by
- 75
- References
- 15
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 7 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 3 · 2018: 7 · 2017: 6 · 2016: 7 · 2015: 7 · 2014: 4 · 2013: 5 · 2012: 4
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- green
- infoscience.epfl.ch
- Locations
- IEEE Transactions on Neural Systems and Rehabilitation Engineering (publishedVersion)
- PubMed (publishedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Portal (King's College London) (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/C52330X/1, EP/H00727X/1)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve interfaces, axon regeneration, nerve guidance channels, silicon microchannels, action potential amplitude, in vivo electrophysiology, peripheral nerve stimulation
- MeSH terms
- Action Potentials, Animals, Electrodes, Implanted, Equipment Design, Male, Microelectrodes, Nerve Regeneration, Sensitivity and Specificity, Reproducibility of Results, Equipment Failure Analysis, Sciatic Neuropathy, Guided Tissue Regeneration, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.