The DOI matches its Crossref record; 153 of the 153 references it cites were found in a registry or an index.
Airborne spread of expiratory droplet nuclei between the occupants of indoor environments: A review
Open accessAbstract
This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The numerical computation of turbulent flows
Launder, B. E., & Spalding, D. B. (1974) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(74)90029-2 · Cited by 12,833
Wilcox, D. C. (1993) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 7,475
Renormalization group analysis of turbulence. I. Basic theory
Yakhot, V., & Orszag, S. A. (1986) · Journal of Scientific Computing · doi:10.1007/bf01061452 · Cited by 4,265
Siegel, J. D., Rhinehart, E., Jackson, M., & Chiarello, L. (2007) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.007 · Cited by 3,456
Influenza Virus Transmission Is Dependent on Relative Humidity and Temperature
Lowen, A. C., Mubareka, S., Steel, J., & Palese, P. (2007) · PLoS Pathogens · doi:10.1371/journal.ppat.0030151 · Cited by 1,669
Principles and Practice of Infectious Diseases
Larson, H. E. (1980) · Journal of Clinical Pathology · doi:10.1136/jcp.33.9.907-a · Cited by 1,276
(2005) · PsycEXTRA Dataset · doi:10.1037/e545842006-001 · Cited by 1,274
Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome Virus
Yu, I. T. S., Li, Y., Wong, T. W., Tam, W., Chan, A. T., Lee, J. H. W., Leung, D. Y. C., & Ho, T. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032867 · Cited by 1,256
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Ventilation performance prediction for buildings: A method overview and recent applications
Chen, Q. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.05.025 · Cited by 957
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
Awbi, H. B. (2002) · Routledge eBooks · doi:10.4324/9780203476307 · Cited by 900
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
Quantitative Microbial Risk Assessment
Haas, C. N., Rose, J. B., & Gerba, C. P. (2014) · Wiley eBooks · doi:10.1002/9781118910030 · Cited by 861
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Zhang, Z., Zhang, W., Zhai, Z. J., & Chen, Q. Y. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10391460 · Cited by 746
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Guidelines for Environmental Infection Control in Health-Care Facilities: (545922006-001)
(2003) · PsycEXTRA Dataset · doi:10.1037/e545922006-001 · Cited by 687
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Droplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Flow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605
Characterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564
Exhaled droplets due to talking and coughing
Xie, X., Li, Y., Sun, H., & Liu, L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0388.focus · Cited by 527
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
The Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-75-4-653_1 · Cited by 466
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
The Mechanism of Breath Aerosol Formation
Johnson, G. R., & Morawska, L. (2009) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2008.0720 · Cited by 434
Zhu, S., Kato, S., & Yang, J.-H. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.06.024 · Cited by 428
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Morawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
Inhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362
Personalized ventilation: evaluation of different air terminal devices
Melikov, A. K., Cermak, R., & Majer, M. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00102-0 · Cited by 332
Self-citationCole, E. C., & Cook, C. E. (1998) · American Journal of Infection Control · doi:10.1016/s0196-6553(98)70046-x · Cited by 317
Survival of Severe Acute Respiratory Syndrome Coronavirus
Lai, M. Y. Y., Cheng, P. K. C., & Lim, W. W. L. (2005) · Clinical Infectious Diseases · doi:10.1086/433186 · Cited by 313
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
Lindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300
Tang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0295.focus · Cited by 300
Principles and Practice of Infectious Diseases
Ridgway, G. (1990) · Journal of Clinical Pathology · doi:10.1136/jcp.43.6.523-e · Cited by 298
Bjørn, E., & Nielsen, P. V. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.08126.x · Cited by 294
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Tracer-gas techniques for measuring ventilation in a single zone
Sherman, M. H. (1990) · Building and Environment · doi:10.1016/0360-1323(90)90010-o · Cited by 291
Airflow Dynamics of Human Jets: Sneezing and Breathing - Potential Sources of Infectious Aerosols
Tang, J. W., Nicolle, A. D., Klettner, C. A., Pantelic, J., Wang, L., Suhaimi, A. B., Tan, A. Y. L., Ong, G. W. X., Su, R., Sekhar, C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059970 · Cited by 284
Bennett, D. H., McKone, T. E., Evans, J. S., Nazaroff, W. W., Margni, M. D., Jolliet, O., & Smith, K. R. (2002) · PubMed · Cited by 277
Fifty years of CFD for room air distribution
Nielsen, P. V. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.035 · Cited by 276
Modeling particle dispersion and deposition in indoor environments
Gao, N. P., & Niu, J. L. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.016 · Cited by 273
Particle size and pathogenicity in the respiratory tract
Thomas, R. J. (2013) · Virulence · doi:10.4161/viru.27172 · Cited by 270
Peer Reviewed: Defining Intake Fraction
Bennett, D. H., McKone, T. E., Evans, J. S., Nazaroff, W. W., Margni, M. D., Jolliet, O., & Smith, K. R. (2002) · Environmental Science & Technology · doi:10.1021/es0222770 · Cited by 264
Zayas, G., Chiang, M. C., Wong, E., MacDonald, F., Lange, C. F., Senthilselvan, A., & King, M. (2012) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-12-11 · Cited by 227
Effect of airway opening on production of exhaled particles
Almstrand, A.-C., Bake, B., Ljungström, E., Larsson, P., Bredberg, A., Mirgorodskaya, E., & Olin, A.-C. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00873.2009 · Cited by 226
A Computational and Experimental Investigation of the Human Thermal Plume
Craven, B. A., & Settles, G. S. (2006) · Journal of Fluids Engineering · doi:10.1115/1.2353274 · Cited by 217
Airborne transmission of disease in hospitals
Eames, I., Tang, J. W., Li, Y., & Wilson, P. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0407.focus · Cited by 216
Study on the initial velocity distribution of exhaled air from coughing and speaking
Kwon, S.-B., Park, J., Jang, J., Cho, Y., Park, D.-S., Kim, C., Bae, G.-N., & Jang, A. (2012) · Chemosphere · doi:10.1016/j.chemosphere.2012.01.032 · Cited by 210
(1991) · PubMed · Cited by 205
Li, Y., & Nielsen, P. V. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2011.00723.x · Cited by 192
Olmedo, I., Nielsen, P. V., Ruiz de Adana, M., Jensen, R. L., & Grzelecki, P. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00736.x · Cited by 183
Numerical study of the transport of droplets or particles generated by respiratory system indoors
Zhao, B., Zhang, Z., & Li, X. (2005) · Building and Environment · doi:10.1016/j.buildenv.2004.09.018 · Cited by 183
Advanced air distribution: improving health and comfort while reducing energy use
Melikov, A. K. (2016) · Indoor Air · doi:10.1111/ina.12206 · Cited by 180
Self-citationThermal manikin history and applications
Holm�r, I. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1135-0 · Cited by 174
Koullapis, P. G., Kassinos, S. C., Bivolarova, M. P., & Melikov, A. K. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.029 · Cited by 170
Self-citationDispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system
Qian, H., Li, Y., Nielsen, P. V., & Hyldgaard, C. E. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.025 · Cited by 169
Transport of particulate and gaseous pollutants in the vicinity of a human body
Rim, D., & Novoselac, A. (2009) · Building and Environment · doi:10.1016/j.buildenv.2008.12.009 · Cited by 168
Experimental investigation of the human convective boundary layer in a quiescent indoor environment
Licina, D., Pantelic, J., Melikov, A., Sekhar, C., & Tham, K. W. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.01.016 · Cited by 167
Self-citationTransient CFD simulation of the respiration process and inter-person exposure assessment
Gao, N., & Niu, J. (2005) · Building and Environment · doi:10.1016/j.buildenv.2005.05.014 · Cited by 164
Size distribution of exhaled particles in the range from 0.01 to 2.0μm
Holmgren, H., Ljungström, E., Almstrand, A.-C., Bake, B., & Olin, A.-C. (2010) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.02.011 · Cited by 158
Bivolarova, M. P., Ondráček, J., Melikov, A. K., & Ždímal, V. (2017) · Indoor Air · doi:10.1111/ina.12388 · Cited by 158
Self-citationPersonal Exposure in Displacement Ventilated Rooms
Brohus, H., & Nielsen, P. V. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.t01-1-00003.x · Cited by 157
Measurement and prediction of indoor air quality using a breathing thermal manikin
Melikov, A. K., & Kaczmarczyk, J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00451.x · Cited by 154
Self-citationInhalation intake fraction of pollutants from episodic indoor emissions
Nazaroff, W. W. (2006) · Building and Environment · doi:10.1016/j.buildenv.2006.03.021 · Cited by 149
Computational fluid dynamics and room air movement
Nielsen, P. V. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00282.x · Cited by 147
Performance of Personalized Ventilation in Conjunction with Mixing and Displacement Ventilation
Cermak, R., Melikov, A. K., Forejt, L., & Kovar, O. (2006) · Science and Technology for the Built Environment · doi:10.1080/10789669.2006.10391180 · Cited by 144
Self-citationInfluence of movements on contaminant transport in an operating room
Brohus, H., Balling, K. D., & Jeppesen, D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00454.x · Cited by 144
Tang, J. W.-T., Noakes, C. J., Nielsen, P. V., Eames, I., Nicolle, A., Li, Y., & Settles, G. S. (2010) · Journal of Hospital Infection · doi:10.1016/j.jhin.2010.09.037 · Cited by 142
Control of airborne infectious diseases in ventilated spaces
Nielsen, P. V. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0228.focus · Cited by 141
Qian, H., & Li, Y. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2010.00653.x · Cited by 141
Chao, C. Y. H., & Wan, M. P. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00426.x · Cited by 141
Exhaled Air Dispersion Distances During Noninvasive Ventilation via Different Respironics Face Masks
Hui, D. S. C., Chow, B., Ng, S. S., Chu, L. C. Y., Hall, S. D., Gin, T., Sung, J. J. �., & Chan, M. T. V. (2009) · CHEST Journal · doi:10.1378/chest.09-0434 · Cited by 137
Riley, R. L. (1974) · The American Journal of Medicine · doi:10.1016/0002-9343(74)90140-5 · Cited by 133
Particle Image Velocimetry of Human Cough
VanSciver, J. M., Miller, S. L., & Hertzberg, J. (2011) · Aerosol Science and Technology · doi:10.1080/02786826.2010.542785 · Cited by 132
Human exhalation characterization with the aid of schlieren imaging technique
Xu, C., Nielsen, P. V., Liu, L., Jensen, R. L., & Gong, G. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.11.032 · Cited by 130
Temperatures of expired air under varying climatic conditions
Höppe, P. (1981) · International Journal of Biometeorology · doi:10.1007/bf02184460 · Cited by 128
Human body micro-environment: The benefits of controlling airflow interaction
Melikov, A. K. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.010 · Cited by 128
Self-citationPersonalized ventilation as a control measure for airborne transmissible disease spread
Pantelic, J., Sze-To, G. N., Tham, K. W., Chao, C. Y. H., & Khoo, Y. C. M. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0311.focus · Cited by 124
Sze-To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., & Melikov, A. K. (2009) · Aerosol Science and Technology · doi:10.1080/02786820902736658 · Cited by 118
Self-citationGao, N., Niu, J., & Morawska, L. (2008) · Building Simulation · doi:10.1007/s12273-008-8328-0 · Cited by 110
Experimental Air-Borne Influenza Infection. I. Influence of Humidity on Survival of Virus in Air.
Loosli, C. G., Lemon, H. M., ROBERTSON, O. H., & Appel, E. (1943) · Experimental Biology and Medicine · doi:10.3181/00379727-53-14251p · Cited by 107
Yang, J., Sekhar, C., Cheong, D. K. W., & Raphael, B. (2014) · Indoor Air · doi:10.1111/ina.12127 · Cited by 105
Cermak, R., & Melikov, A. K. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390942 · Cited by 105
Self-citationHuman convective boundary layer and its interaction with room ventilation flow
Licina, D., Melikov, A., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12120 · Cited by 104
Self-citationSubmicron droplet formation in the human lung
Haslbeck, K., Schwarz, K., Hohlfeld, J. M., Seume, J. R., & Koch, W. (2010) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.02.010 · Cited by 103
Exhaled Air and Aerosolized Droplet Dispersion During Application of a Jet Nebulizer
Hui, D. S. C., Chow, B., Chu, L. C. Y., Ng, S. S., Hall, S. D., Gin, T., & Chan, M. T. V. (2009) · CHEST Journal · doi:10.1378/chest.08-1998 · Cited by 101
Bolashikov, Z. D., Melikov, A. K., Kierat, W., Popiołek, Z., & Brand, M. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2012.682692 · Cited by 100
Self-citationSome aspects of the airborne transmission of infection
Clark, R. P., & de Calcina-Goff, M. L. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0236.focus · Cited by 98
Ai, Z., Mak, C. M., & Niu, J. (2013) · Indoor Air · doi:10.1111/ina.12041 · Cited by 97
Self-citationInfluence of human breathing modes on airborne cross infection risk
Villafruela, J. M., Olmedo, I., & Alonso, J. F. S. J. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.07.005 · Cited by 93
Xiao-ping, L., Niu, J., & Gao, N. (2011) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.578699 · Cited by 87
Liu, X., Niu, J., Kwok, K. C. S., Wang, J. H., & Li, B. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.02.003 · Cited by 87
Protected zone ventilation and reduced personal exposure to airborne cross-infection
Cao, G., Nielsen, P. V., Jensen, R. L., Heiselberg, P., Liu, L., & Heikkinen, J. (2014) · Indoor Air · doi:10.1111/ina.12142 · Cited by 85
Melikov, A. K. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1142-1 · Cited by 84
Self-citationThe risk of airborne cross-infection in a room with vertical low-velocity ventilation
Olmedo, I., Nielsen, P. V., de Adana, M. R., & Jensen, R. L. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00794.x · Cited by 83
Risk of cross-infection in a hospital ward with downward ventilation
Nielsen, P. V., Li, Y., Buus, M., & Winther, F. V. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.02.017 · Cited by 82
Pantelic, J., & Tham, K. W. (2013) · Science and Technology for the Built Environment · doi:10.1080/10789669.2013.842447 · Cited by 80
Li, X., Niu, J., & Gao, N. (2012) · Indoor Air · doi:10.1111/ina.12005 · Cited by 80
Documentary Research of Human Respiratory Droplet Characteristics
Zhang, H., Li, D., Xie, L., & Xiao, Y. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.09.023 · Cited by 77
Impact of personal factors and furniture arrangement on the thermal plume above a sitting occupant
Zukowska, D., Melikov, A. K., & Popiołek, Z. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.09.015 · Cited by 76
Self-citationTang, J. W.-T., Nicolle, A., Pantelic, J., Koh, G. C., Wang, L. D., Amin, M., Klettner, C. A., Cheong, D. K. W., Sekhar, C., & Tham, K. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0034818 · Cited by 75
Sze-To, G. N., Wan, M. P., Chao, C. Y. H., Wei, F., Yu, S. C. T., & Kwan, J. K. C. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00544.x · Cited by 75
Computational Study of the Wake and Contaminant Transport of a Walking Human
Edge, B. A., Paterson, E. G., & Settles, G. S. (2005) · Journal of Fluids Engineering · doi:10.1115/1.2013291 · Cited by 71
Licina, D., Melikov, A., Pantelic, J., Sekhar, C., & Tham, K. W. (2015) · Indoor Air · doi:10.1111/ina.12177 · Cited by 69
Self-citationHalvoňová, B., & Melikov, A. K. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.06.023 · Cited by 68
Self-citationHan, Z., Sze-To, G. N., Fu, S. C., Chao, C. Y. H., Weng, W., & Huang, Q. (2014) · BMC Infectious Diseases · doi:10.1186/1471-2334-14-434 · Cited by 67
Nielsen, P. V., Olmedo, I., de Adana, M. R., Grzelecki, P., & Jensen, R. L. (2012) · Science and Technology for the Built Environment · doi:10.1080/10789669.2011.598441 · Cited by 64
Mazumdar, S., Yin, Y., Guity, A., Marmion, P., Gulick, B., & Chen, Q. (2010) · Science and Technology for the Built Environment · doi:10.1080/10789669.2010.10390921 · Cited by 62
Pantelic, J., Tham, K. W., & Licina, D. (2015) · Indoor Air · doi:10.1111/ina.12187 · Cited by 61
Large eddy simulation of wind-induced interunit dispersion around multistory buildings
Ai, Z., & Mak, C. M. (2015) · Indoor Air · doi:10.1111/ina.12200 · Cited by 60
Self-citationLaußmann, D., & Helm, D. (2011) · InTech eBooks · doi:10.5772/18600 · Cited by 58
Nielsen, P. V., Hyldgaard, C. E., Melikov, A. K., Andersen, H., & Soennichsen, M. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390976 · Cited by 58
Self-citationAirborne Contagion and Air Hygiene: An Ecological Study of Droplet Infection
(1957) · Tubercle · doi:10.1016/s0041-3879(57)80076-2 · Cited by 58
Yin, Y., Gupta, J. K., Zhang, X., Liu, J., & Chen, Q. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.07.003 · Cited by 56
Wu, Y., Tung, T. C. W., & Niu, J. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.01.013 · Cited by 55
Effect of airflow interaction in the breathing zone on exposure to bio-effluents
Bivolarova, M. P., Kierat, W., Zavrl, E., Popiołek, Z., & Melikov, A. K. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.08.043 · Cited by 55
Self-citationMu, D., Gao, N., & Zhu, T. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.08.032 · Cited by 54
Influence of air stability and metabolic rate on exhaled flow
Xu, C., Nielsen, P. V., Gong, G., Jensen, R. L., & Liu, L. (2014) · Indoor Air · doi:10.1111/ina.12135 · Cited by 49
Advanced air distribution for minimizing airborne cross-infection in aircraft cabins
Melikov, A. K., & Dzhartov, V. (2013) · Science and Technology for the Built Environment · doi:10.1080/10789669.2013.818468 · Cited by 42
Self-citationYang, C., Yang, X., & Zhao, B. (2016) · Building Simulation · doi:10.1007/s12273-016-0290-7 · Cited by 42
Contaminant dispersion in the vicinity of a worker in a uniform velocity field
Welling, I. (2000) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(99)00081-2 · Cited by 40
Yang, J., Sekhar, C., Cheong, D. K. W., & Raphael, B. (2015) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.976511 · Cited by 40
Transport of Airborne Particles from an Unobstructed Cough Jet
Liu, S., & Novoselac, A. (2014) · Aerosol Science and Technology · doi:10.1080/02786826.2014.968655 · Cited by 39
TR-PIV measurement of exhaled flow using a breathing thermal manikin
Feng, L., Yao, S., Sun, H., Jiang, N., & Liu, J. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.11.001 · Cited by 36
Transport of gaseous pollutants by convective boundary layer around a human body
Licina, D., Melikov, A. K., Sekhar, C., & Tham, K. W. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1060111 · Cited by 33
Self-citationHumans as a Source of Heat and Air Pollution
Hyldgård, C.-E. (1994) · Cited by 33
Convective exchange between the nose and the atmosphere
Haselton, F. R., & Sperandio, P. G. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2575 · Cited by 33
The use of thermal manikins to evaluate clothing and environmental factors
McCullough, E. A. (2005) · Elsevier ergonomics book series · doi:10.1016/s1572-347x(05)80064-3 · Cited by 32
Experimental assessment of the inhalation zone of standing, sitting and sleeping persons
Laverge, J., Spilak, M. P., & Novoselac, A. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.08.014 · Cited by 31
Habchi, C., Ghali, K., & Ghaddar, N. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.05.009 · Cited by 31
Engineering control of respiratory infection and low-energy design of healthcare facilities
Li, Y., Tang, J. W.-T., Noakes, C. J., & Hodgson, M. J. (2014) · Science and Technology for the Built Environment · doi:10.1080/10789669.2014.965557 · Cited by 30
Araujo, G. A. L., Freire, R. C. S., Silva, J. F., de Oliveira, A. C., & Jaguaribe, E. F. (2004) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2004.1351149 · Cited by 28
Anisotropy in the breathing zone of a thermal manikin
Marr, D. R., Spitzer, I., & Glauser, M. (2007) · Experiments in Fluids · doi:10.1007/s00348-007-0425-9 · Cited by 27
Cao, G., Liu, S., Boor, B. E., & Novoselac, A. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.03.0146 · Cited by 26
Poon, C. K. M., & Lai, A. C. K. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.06.040 · Cited by 16
Protection Against Cross Infection in Hospital Beds with Integrated Personalized Ventilation
Nielsen, P. V., Polak, M., Jiang, H., Li, Y., & Qian, H. (2008) · VBN Forskningsportal (Aalborg Universitet) · Cited by 12
Aerodynamic properties of biohazardous aerosols in hospitals
Fang, M., Lau, A. P. S., Chan, C. K., Hung, C.-H., & Lee, T. W. (2008) · Rare & Special e-Zone (The Hong Kong University of Science and Technology) · Cited by 11
Palmore, T. N., & Sepkowitz, K. A. (2011) · Wiley eBooks · doi:10.1002/0471435139.hyg111 · Cited by 7
Licina, D., Melikov, A. K., Tham, K. W., & Sekhar, C. (2016) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 2
Self-citationSmagorinsky (1963) · doi:10.1175/1520-0493(1963)091<0099:gcewtp>2.3.co;2
Cited by
Vuorinen, V., Aarnio, M., Alava, M., Alopaeus, V., Atanasova, N., Auvinen, M., Balasubramanian, N., Bordbar, H., Erästö, P., Grande, R., et al. (2020) · Safety Science · doi:10.1016/j.ssci.2020.104866 · Cited by 472
“In earlier studies, pathogen transmission has been investigated widely in various indoor environments (Li et al., 2007; Morawska et al., 2017; Ai and Melikov, 2018).”
Buonanno, G., Morawska, L., & Stabile, L. (2020) · Environment International · doi:10.1016/j.envint.2020.106112 · Cited by 449
“It is necessary to understand the characteristics and mechanisms behind the generation of respiratory microdroplets (Ai and Melikov, 2018; Holmgren et al., 2010), the survival of viruses in microdroplets (van Doremalen et al., 2020), the transport of microdroplets and human exposure to them (Ai et…”
BackgroundSadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Azuma, K., Yanagi, U., Kagi, N., Kim, H., Ogata, M., & Hayashi, M. (2020) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-020-00904-2 · Cited by 263
Blocken, B., van Druenen, T., Ricci, A., Kang, L., van Hooff, T., Qin, P., Xia, L., Ruiz, C. A., Arts, J. H., Diepens, J. F. L., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107659 · Cited by 183
Metadata
- Authors
- Ai, Z. T., & Melikov, A. K.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2018-05-08
- Volume
- 28
- Issue
- 4
- Pages
- 500-524
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2799524318
- Cited by
- 278
- References
- 153
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.