ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
A successful method for removing artifacts from electroencephalogram (EEG) recordings is Independent Component Analysis (ICA), but its implementation remains largely user‐dependent. Here, we propose a completely automatic algorithm (ADJUST) that identifies artifacted independent components by combining stereotyped artifact‐specific spatial and temporal features. Features were optimized to capture blinks, eye movements, and generic discontinuities on a feature selection dataset. Validation on a totally different EEG dataset shows that (1) ADJUST's classification of independent components largely matches a manual one by experts (agreement on 95.2% of the data variance), and (2) Removal of the artifacted components detected by ADJUST leads to neat reconstruction of visual and auditory event‐related potentials from heavily artifacted data. These results demonstrate that ADJUST provides a fast, efficient, and automatic way to use ICA for artifact removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Advances in neural information processing systems 7
Cios, K., & Shields, M. (1997) · Neurocomputing · doi:10.1016/s0925-2312(97)90018-7 · Cited by 22,059
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
Independent Component Analysis
(2004) · Independent Component Analysis · doi:10.7551/mitpress/3717.003.0014 · Cited by 7,903
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
A blind source separation technique using second-order statistics
Belouchrani, A., Abed-Meraim, K., Cardoso, J.-F., & Moulines, E. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.554307 · Cited by 2,775
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Research works printed but not linked: 2
- 10.1111/1469-8986.3720163 · doi:10.1111/1469-8986.3720163 · Paper page
- 10.1088/0967-3334/28/12/006 · doi:10.1088/0967-3334/28/12/006
Cited by
ERPLAB: an open-source toolbox for the analysis of event-related potentials
Lopez-Calderon, J., & Luck, S. J. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00213 · Cited by 2,584
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
The PREP pipeline: standardized preprocessing for large-scale EEG analysis
Bigdely-Shamlo, N., Mullen, T., Kothe, C., Su, K.-M., & Robbins, K. A. (2015) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2015.00016 · Cited by 1,351
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Grootswagers, T., Wardle, S. G., & Carlson, T. A. (2017) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01068 · Cited by 727
Venkatraman, V., Dimoka, A., Pavlou, P. A., Vo, K., Hampton, W., Bollinger, B., Hershfield, H. E., Ishihara, M., & Winer, R. S. (2015) · Journal of Marketing Research · doi:10.1509/jmr.13.0593 · Cited by 549
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Chennu, S., Annen, J., Wannez, S., Thibaut, A., Chatelle, C., Cassol, H., Martens, G., Schnakers, C., Gosseries, O., Menon, D., et al. (2017) · Brain · doi:10.1093/brain/awx163 · Cited by 339
“There have been many recent methodological advances in automating this step (Nolan et al., 2010; Mognon et al., 2011; Jas et al., 2016), and future work towards validating these methods with patient datasets could help develop the analytical pipeline for clinical applications.”
BackgroundSmith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Automagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
Somers, B., Francart, T., & Bertrand, A. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaac92 · Cited by 255
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“properties of ICs [22], [23], [89], [115].”
BackgroundMethodInfluentialOptimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Dimigen, O. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116117 · Cited by 222
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
The Amsterdam Resting-State Questionnaire reveals multiple phenotypes of resting-state cognition
Diaz, B. A., Van Der Sluis, S., Moens, S., Benjamins, J. S., Migliorati, F., Stoffers, D., Den Braber, A., Poil, S.-S., Hardstone, R., Van't Ent, D., et al. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00446 · Cited by 194
Effects of user mental state on EEG-BCI performance
Myrden, A., & Chau, T. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00308 · Cited by 211
“Signals were band-pass filtered between 2 and 30 Hz, and artifacts resulting from eye movements were removed using independent component analysis (Mognon et al., 2011).”
MethodMobile EEG in research on neurodevelopmental disorders: Opportunities and challenges
Lau-Zhu, A., Lau, M. P. H., & McLoughlin, G. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100635 · Cited by 201
EEG-Informed fMRI: A Review of Data Analysis Methods
Abreu, R., Leal, A., & Figueiredo, P. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00029 · Cited by 171
Grassini, S., Revonsuo, A., Castellotti, S., Petrizzo, I., Benedetti, V., & Koivisto, M. (2019) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2019.01.007 · Cited by 169
Decoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
Behavioral, Modeling, and Electrophysiological Evidence for Supramodality in Human Metacognition
Faivre, N., Filevich, E., Solovey, G., Kühn, S., & Blanke, O. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.0322-17.2017 · Cited by 129
“Signal preprocessing was performed using custom MATLAB (The MathWorks; RRID: SCR_001622) scripts using functions from the EEGLAB (version 13.5.4; Delorme and Makeig, 2004; RRID:SCR_007292), Adjust (Mognon et al., 2011; RRID:SCR_009526) and Sasica toolboxes (Chaumon et al., 2015).”
MethodInfluentialEmotional and non-emotional pathways to impulsive behavior and addiction.
Torres, A., Catena, A., Megías, A., Maldonado, A., Cándido, A., Verdejo-García, A., & Perales, J. C. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00043 · Cited by 99
“Epochs were corrected for ocular artifacts by first computing the SOBI ICA decomposition (Belouchrani et al., 1993, 1997; Cardoso and Souloumiac, 1996, see also Tang et al., 2004) as identified by the ADJUST algorithm (Mognon et al., 2011).”
MethodDebnath, R., Tang, A., Zeanah, C. H., Nelson, C. A., & Fox, N. A. (2020) · Developmental Science · doi:10.1111/desc.12872 · Cited by 94
“Artifactual independent components (ICs) were identified and removed from the data using the ADJUST plugin (Mognon et al., 2011) of EEGLAB and by visual inspection of individual ICs.”
MethodDi Gregorio, F., Maier, M. E., & Steinhauser, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.081 · Cited by 85
EEG fingerprinting: subject-specific signature based on the aperiodic component of power spectrum
Demuru, M., & Fraschini, M. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103748 · Cited by 82
Enhanced functional connectivity properties of human brains during in-situ nature experience
Chen, Z., He, Y., & Yu, Y. (2016) · PeerJ · doi:10.7717/peerj.2210 · Cited by 74
“Data were first filtered (<0.5 Hz or >50 Hz) using EEGlab and 150 artifacts were removed using Adjust 1.1 (Mognon et al. 2011).”
MethodInfluentialBilleci, L., Callara, A. L., Guiducci, L., Prosperi, M., Morales, M. A., Calderoni, S., Muratori, F., & Santocchi, E. (2023) · Autism · doi:10.1177/13623613221082710 · Cited by 69
“Artifactual components were removed using the ADJUST EEGLAB plugin (Mognon et al., 2011) and by visual inspection and then”
MethodAdolescent cognitive control, theta oscillations, and social observation
Buzzell, G. A., Barker, T. V., Troller-Renfree, S. V., Bernat, E. M., Bowers, M. E., Morales, S., Bowman, L. C., Henderson, H. A., Pine, D. S., & Fox, N. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.077 · Cited by 65
“Artifactual ICA components were first detected in an automated procedure using the ADJUST toolbox (Mognon et al. 2011), followed by manual inspection of the ICA components (see supplement for further details).”
MethodYeung, M. K., Han, Y. M. Y., Sze, S. L., & Chan, A. S. (2016) · Neuropsychology · doi:10.1037/neu0000231 · Cited by 57
Signal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Infants of mothers with higher physiological stress show alterations in brain function
Troller‐Renfree, S. V., Brito, N. H., Desai, P. M., Leon‐Santos, A. G., Wiltshire, C. A., Motton, S. N., Meyer, J. S., Isler, J., Fifer, W. P., & Noble, K. G. (2020) · Developmental Science · doi:10.1111/desc.12976 · Cited by 52
Catena, A., Muñoz-Machicao, J. A., Torres-Espínola, F. J., Martínez-Zaldívar, C., Diaz-Piedra, C., Gil, A., Haile, G., Györei, E., Molloy, A. M., Decsi, T., et al. (2016) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.115.109108 · Cited by 46
Banellis, L., & Cruse, D. (2020) · Cerebral Cortex Communications · doi:10.1093/texcom/tgaa060 · Cited by 44
Shenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
“The ADJUST (automatic detector – joint use of spatial and temporal features) plug-in extension to the EEGLAB toolbox was used [38] to avoid the time-consuming process of manual inspection of all ICs.”
MethodMu rhythm suppression is associated with the classification of emotion in faces
Moore, M. R., & Franz, E. A. (2017) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/s13415-016-0476-6 · Cited by 30
Buzzell, G. A., Troller-Renfree, S. V., Wade, M., Debnath, R., Morales, S., Bowers, M. E., Zeanah, C. H., Nelson, C. A., & Fox, N. A. (2020) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2020.100777 · Cited by 30
Multimodal study of the neural sources of error monitoring in adolescents and adults
Conte, S., Richards, J. E., Fox, N. A., Valadez, E. A., McSweeney, M., Tan, E., Pine, D. S., Winkler, A. M., Liuzzi, L., Cardinale, E. M., et al. (2023) · Psychophysiology · doi:10.1111/psyp.14336 · Cited by 5
Vocalizing and singing reveal complex patterns of corollary discharge function in schizophrenia
Ford, J. M., Roach, B. J., & Mathalon, D. H. (2021) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.02.013 · Cited by 5
Valadez, E. A., Jopling, E., Macera, E., Wade, M., Zeanah, C. H., Nelson, C. A., & Fox, N. A. (2026) · Development and Psychopathology · doi:10.1017/s0954579426101928
Metadata
- Authors
- Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2011-01-06
- Volume
- 48
- Issue
- 2
- Pages
- 229-240
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2507937192
- Cited by
- 1,290
- References
- 43
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.