Effects of titanium surface topography on bone integration: a systematic review
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Aim: To analyse possible effects of titanium surface topography on bone integration. Materials and methods: Our analyses were centred on a PubMed search that identified 1184 publications of assumed relevance; of those, 1064 had to be disregarded because they did not accurately present in vivo data on bone response to surface topography. The remaining 120 papers were read and analysed, after removal of an additional 20 papers that mainly dealt with CaP‐coated and Zr implants; 100 papers remained and formed the basis for this paper. The bone response to differently configurated surfaces was mainly evaluated by histomorphometry (bone‐to‐implant contact), removal torque and pushout/pullout tests. Results and discussion: A huge number of the experimental investigations have demonstrated that the bone response was influenced by the implant surface topography; smooth (Sa<0.5 μm) and minimally rough (Sa 0.5–1 μm) surfaces showed less strong bone responses than rougher surfaces. Moderately rough (Sa>1–2 μm) surfaces showed stronger bone responses than rough (Sa>2 μm) in some studies. One limitation was that it was difficult to compare many studies because of the varying quality of surface evaluations; a surface termed ‘rough’ in one study was not uncommonly referred to as ‘smooth’ in another; many investigators falsely assumed that surface preparation per se identified the roughness of the implant; and many other studies used only qualitative techniques such as SEM. Furthermore, filtering techniques differed or only height parameters (Sa, Ra) were reported. Conclusions: • Surface topography influences bone response at the micrometre level. • Some indications exist that surface topography influences bone response at the nanometre level. • The majority of published papers present an inadequate surface characterization. • Measurement and evaluation techniques need to be standardized. • Not only height descriptive parameters but also spatial and hybrid ones should be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Albrektsson, T., Brånemark, P.-I., Hansson, H.-A., & Lindström, J. (1981) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678108991776 · Cited by 2,690
Self-citationSurface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Buser, D., Schenk, R. K., Steinemann, S., Fiorellini, J. P., Fox, C. H., & Stich, H. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250708 · Cited by 1,719
Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Albrektsson, T. O., & Wennerberg, A. (2004) · PubMed · Cited by 1,118
Self-citationImproved biological performance of Ti implants due to surface modification by micro-arc oxidation
Li, L.-H., Kong, Y.-M., Kim, H.-W., Kim, Y.-W., Kim, H.-E., Heo, S.-J., & Koak, J.-Y. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.048 · Cited by 676
Wennerberg, A., Albrektsson, T., Andersson, B., & Krol, J. J. (1995) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1995.060103.x · Cited by 537
Self-citationImplant Surface Roughness and Bone Healing: a Systematic Review
Shalabi, M. M., Gortemaker, A., Hof, M. A. V., Jansen, J. A., & Creugers, N. H. J. (2006) · Journal of Dental Research · doi:10.1177/154405910608500603 · Cited by 531
Suggested guidelines for the topographic evaluation of implant surfaces.
Wennerberg, A., & Albrektsson, T. O. (2000) · PubMed · Cited by 462
Self-citationOsseointegrated Titanium Implants
Holt, G., Parel, S., & Branemark, P. (1986) · Facial Plastic Surgery · doi:10.1055/s-2008-1064831 · Cited by 435
Cited by
A review on the wettability of dental implant surfaces II: Biological and clinical aspects
Gittens, R. A., Scheideler, L., Rupp, F., Hyzy, S. L., Geis-Gerstorfer, J., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.032 · Cited by 849
Significance of calcium phosphate coatings for the enhancement of new bone osteogenesis – A review
Surmenev, R. A., Surmeneva, M. A., & Ivanova, A. A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.036 · Cited by 712
Titanium surface characteristics, including topography and wettability, alter macrophage activation
Hotchkiss, K. M., Reddy, G. B., Hyzy, S. L., Schwartz, Z., Boyan, B. D., & Olivares-Navarrete, R. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.003 · Cited by 680
Raphel, J., Holodniy, M., Goodman, S. B., & Heilshorn, S. C. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.016 · Cited by 674
Surface characteristics of dental implants: A review
Rupp, F., Liang, L., Geis-Gerstorfer, J., Scheideler, L., & Hüttig, F. (2018) · Dental Materials · doi:10.1016/j.dental.2017.09.007 · Cited by 585
Classification of osseointegrated implant surfaces: materials, chemistry and topography
Dohan Ehrenfest, D. M., Coelho, P. G., Kang, B.-S., Sul, Y.-T., & Albrektsson, T. (2010) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.12.003 · Cited by 541
Self-citationTan, X. P., Tan, Y. J., Chow, C. S. L., Tor, S. B., & Yeong, W. Y. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.02.094 · Cited by 514
A review on the wettability of dental implant surfaces I: Theoretical and experimental aspects
Rupp, F., Gittens, R. A., Scheideler, L., Marmur, A., Boyan, B. D., Schwartz, Z., & Geis-Gerstorfer, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.040 · Cited by 507
Lang, N. P., Salvi, G. E., Huynh-Ba, G., Ivanovski, S., Donos, N., & Bosshardt, D. D. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02172.x · Cited by 466
Clinical relevance of dimensional bone and soft tissue alterations post‐extraction in esthetic sites
Chappuis, V., Araújo, M. G., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12167 · Cited by 450
Gittens, R. A., Olivares-Navarrete, R., Schwartz, Z., & Boyan, B. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.037 · Cited by 447
The influence of nano-scale surface roughness on bacterial adhesion to ultrafine-grained titanium
Truong, V. K., Lapovok, R., Estrin, Y. S., Rundell, S., Wang, J. Y., Fluke, C. J., Crawford, R. J., & Ivanova, E. P. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.071 · Cited by 438
Biomedical applications of nanotechnology
Ramos, A. P., Cruz, M. A. E., Tovani, C. B., & Ciancaglini, P. (2017) · Biophysical Reviews · doi:10.1007/s12551-016-0246-2 · Cited by 413
Current trends in dental implants
Gaviria, L., Salcido, J. P., Guda, T., & Ong, J. L. (2014) · Journal of the Korean Association of Oral and Maxillofacial Surgeons · doi:10.5125/jkaoms.2014.40.2.50 · Cited by 407
Titanium Coatings and Surface Modifications: Toward Clinically Useful Bioactive Implants
Civantos, A., Martínez-Campos, E., Ramos, V., Elvira, C., Gallardo, A., & Abarrategi, A. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00604 · Cited by 338
A review of plasma-assisted methods for calcium phosphate-based coatings fabrication
Surmenev, R. A. (2012) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2011.11.002 · Cited by 332
Balancing osteoblast functions and bacterial adhesion on functionalized titanium surfaces
Neoh, K. G., Hu, X., Zheng, D., & Kang, E. T. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.018 · Cited by 330
Zhang, W., Wang, G., Liu, Y., Zhao, X., Zou, D., Zhu, C., Jin, Y., Huang, Q., Sun, J., Liu, X., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.008 · Cited by 311
Zirconia surface modifications for implant dentistry
Schünemann, F. H., Galárraga-Vinueza, M. E., Magini, R., Fredel, M., Silva, F., Souza, J. C. M., Zhang, Y., & Henriques, B. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.01.062 · Cited by 309
Besinis, A., De Peralta, T., Tredwin, C. J., & Handy, R. D. (2015) · ACS Nano · doi:10.1021/nn505015e · Cited by 273
Van der Stok, J., Van der Jagt, O. P., Amin Yavari, S., De Haas, M. F. P., Waarsing, J. H., Jahr, H., Van Lieshout, E. M. M., Patka, P., Verhaar, J. A. N., Zadpoor, A. A., et al. (2013) · Journal of Orthopaedic Research · doi:10.1002/jor.22293 · Cited by 271
Baino, F., & Yamaguchi, S. (2020) · Biomimetics · doi:10.3390/biomimetics5040057 · Cited by 264
Biomechanical behaviours of the bone–implant interface: a review
Gao, X., Fraulob, M., & Haïat, G. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0259 · Cited by 263
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Rasouli, R., Barhoum, A., & Uludag, H. (2018) · Biomaterials Science · doi:10.1039/c8bm00021b · Cited by 242
Porous PEEK improves the bone-implant interface compared to plasma-sprayed titanium coating on PEEK
Torstrick, F. B., Lin, A. S. P., Potter, D., Safranski, D. L., Sulchek, T. A., Gall, K., & Guldberg, R. E. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.009 · Cited by 229
Influence of Dental Prosthesis and Restorative Materials Interface on Oral Biofilms
Hao, Y., Huang, X., Zhou, X., Li, M., Ren, B., Peng, X., & Cheng, L. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19103157 · Cited by 199
Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
Walsh, W. R., Bertollo, N., Christou, C., Schaffner, D., & Mobbs, R. J. (2015) · The Spine Journal · doi:10.1016/j.spinee.2014.12.018 · Cited by 197
“The application of surface topography or coatings to metal substrates has been shown to improve biological implant fixation [18] through bony ongrowth or ingrowth in preclinical [15,19–24] and clinical studies [14,15,25].”
BackgroundInnate immunity activation on biomaterial surfaces: A mechanistic model and coping strategies
Ekdahl, K. N., Lambris, J. D., Elwing, H., Ricklin, D., Nilsson, P. H., Teramura, Y., Nicholls, I. A., & Nilsson, B. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.06.012 · Cited by 196
“Nanostructure – – Low Low Dental titanium implants [98,105]”
BackgroundInfluence of Surface Topographical Cues on the Differentiation of Mesenchymal Stem Cells in Vitro
Metavarayuth, K., Sitasuwan, P., Zhao, X., Lin, Y., & Wang, Q. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00377 · Cited by 189
Review of zirconia-based bioceramic: Surface modification and cellular response
Soon, G., Pingguan-Murphy, B., Lai, K. W., & Akbar, S. A. (2016) · Ceramics International · doi:10.1016/j.ceramint.2016.05.077 · Cited by 180
Scaffolds and coatings for bone regeneration
Pereira, H. F., Cengiz, I. F., Silva, F. S., Reis, R. L., & Oliveira, J. M. (2020) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-020-06364-y · Cited by 178
Implant surface roughness and patient factors on long‐term peri‐implant bone loss
De Bruyn, H., Christiaens, V., Doornewaard, R., Jacobsson, M., Cosyn, J., Jacquet, W., & Vervaeke, S. (2017) · Periodontology 2000 · doi:10.1111/prd.12177 · Cited by 172
Donos, N., Hamlet, S., Lang, N. P., Salvi, G. E., Huynh-Ba, G., Bosshardt, D. D., & Ivanovski, S. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02113.x · Cited by 166
Jiang, P., Zhang, Y., Hu, R., Shi, B., Zhang, L., Huang, Q., Yang, Y., Tang, P., & Lin, C. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.03.006 · Cited by 162
Temporal sequence of hard and soft tissue healing around titanium dental implants
Salvi, G. E., Bosshardt, D. D., Lang, N. P., Abrahamsson, I., Berglundh, T., Lindhe, J., Ivanovski, S., & Donos, N. (2015) · Periodontology 2000 · doi:10.1111/prd.12054 · Cited by 158
Hamlet, S., Alfarsi, M., George, R., & Ivanovski, S. (2012) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2011.02325.x · Cited by 150
Titanium surfaces characteristics modulate macrophage polarization
Zhang, Y., Cheng, X., Jansen, J. A., Yang, F., & van den Beucken, J. J. J. P. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2018.10.065 · Cited by 111
Cao, C., Huang, P., Prasopthum, A., Parsons, A. J., Ai, F., & Yang, J. (2022) · Biomaterials Science · doi:10.1039/d1bm01645h · Cited by 65
Bevilacqua, L., Milan, A., Del Lupo, V., Maglione, M., & Dolzani, L. (2018) · Current Microbiology · doi:10.1007/s00284-018-1446-8 · Cited by 58
“In particular, surface roughness, although improving implant osseointegration [11, 21, 26], has been proposed as the main feature favoring biofilm development [24].”
Staehlke, S., Haack, F., Waldner, A.-C., Koczan, D., Moerke, C., Mueller, P., Uhrmacher, A. M., & Nebe, J. B. (2020) · Cells · doi:10.3390/cells9081784 · Cited by 36
Metadata
- Authors
- Wennerberg, A., & Albrektsson, T.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 2009-07-24
- Volume
- 20
- Issue
- s4
- Pages
- 172-184
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1987654508
- Cited by
- 1,462
- References
- 47
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.