CoChat

Guidance on ambulatory blood pressure monitoring: A statement from the HOPE Asia Network

Open access
Kario, Kazuomi, Hoshide, Satoshi, Chia, Yook‐Chin, Buranakitjaroen, Peera, Siddique, Saulat, Shin, Jinho, Turana, Yuda, Park, Sungha, Tsoi, Kelvin, Chen, Chen‐Huan, Cheng, Hao‐Min, Fujiwara, Takeshi, Li, Yan, Huynh, Van Minh, Nagai, Michiaki, Nailes, Jennifer, Sison, Jorge, Soenarta, Arieska Ann, Sogunuru, Guru Prasad, Sukonthasarn, Apichard, Tay, Jam Chin, Teo, Boon Wee, Verma, Narsingh, Wang, Tzung‐Dau, Zhang, Yuqing, Wang, Ji‐Guang · 2021 · The Journal of Clinical Hypertension
Cited by 98

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Abstract

Hypertension is an important public health issue due to its association with a number of serious diseases, including cardiovascular disease and stroke. The importance of evaluating hypertension taking into account different blood pressure (BP) profiles and BP variability (BPV) is increasingly being recognized, and is particularly relevant in Asian populations given the specific features of hypertension in the region (including greater salt sensitivity and a high rate of nocturnal hypertension). Ambulatory BP monitoring (ABPM) is the gold standard for diagnosing hypertension and assessing 24‐hour BP and provides data on several important parameters that cannot be obtained using any other form of BP measurement. In addition, ABPM parameters provide better information on cardio‐ and cerebrovascular risk than office BP. ABPM should be used in all patients with elevated BP, particularly those with unstable office or home BP, or who are suspected to have white‐coat or masked hypertension. ABPM is also an important part of hypertension diagnosis and monitoring in high‐risk patients. ABPM needs to be performed using a validated device and good practice techniques, and has a role both in hypertension diagnosis and in monitoring the response to antihypertensive therapy to ensure strict BP control throughout the 24‐hour period. Use of ABPM in clinical practice may be limited by cost and accessibility, and practical education of physicians and patients is essential. The ABPM evidence and practice points in this document are based on the Hypertension Cardiovascular Outcome Prevention and Evidence (HOPE) Asia Network expert panel consensus recommendations for ABPM in Asia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jch.14128

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 98

Metadata

Authors
Kario, K., Hoshide, S., Chia, Y., Buranakitjaroen, P., Siddique, S., Shin, J., Turana, Y., Park, S., Tsoi, K., Chen, C., Cheng, H., Fujiwara, T., Li, Y., Huynh, V. M., Nagai, M., Nailes, J., Sison, J., Soenarta, A. A., Sogunuru, G. P., Sukonthasarn, A., Tay, J. C., Teo, B. W., Verma, N., Wang, T., Zhang, Y., & Wang, J.
Venue
The Journal of Clinical Hypertension
Publisher
Wiley
Published
2020-12-14
Volume
23
Issue
3
Pages
411-421
ISSN
  • 1524-6175 (ISSN-L)
  • 1751-7176
OpenAlex
W3111663266
Cited by
98
References
28
FWCI
5.03
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.