CoChat

Rubbery electronics and sensors from intrinsically stretchable elastomeric composites of semiconductors and conductors

Open access
Kim, Hae-Jin, Sim, Kyoseung, Thukral, Anish, Yu, Cunjiang · 2017 · Science Advances

The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.

Abstract

Stretchable rubber-like electronics from intrinsically stretchable semiconductors and conductors are demonstrated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1126/sciadv.1701114

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Intrinsically stretchable electronic materials. (A) Schematic illustrations of a sensor (upper) and a TFT (lower), consisting of AuNP-AgNW conductors, P3HT-NF/PDMS semiconductor composite, and ion gel dielectric vertically stacked on a PDMS substrate. (B) Schematic illustrations (upper) and SEM images (lower) of the AgNWs before (left) and after (right) the galvanic replacement process to conformally coat AuNPs on exposed AgNWs. (C) Sheet resistance (ohms/□) of the AuNP-AgNW/PDMS conductor under different levels of mechanical strain. The SEM images of the stretched conductor are shown at the bottom. (D) AFM surface topography (left) and phase mode (right) images of the P3HT-NF/PDMS film. (E) AFM phase mode images of P3HT-NF/PDMS coated on a PDMS substrate upon uniaxial stretching. Yellow arrows indicate P3HT-NF rupture. (F) Photographs of the P3HT-NF/PDMS film on a thin PDMS substrate under various forms of mechanical deformation. (G) Photographs of free-standing ion gel dielectric before and after stretching.
Fig. 1 Intrinsically stretchable electronic materials. (A) Schematic illustrations of a sensor (upper) and a TFT (lower), consisting of AuNP-AgNW conductors, P3HT-NF/PDMS semiconductor composite, and ion gel dielectric vertically stacked on a PDMS substrate. (B) Schematic illustrations (upper) and SEM images (lower) of the AgNWs before (left) and after (right) the galvanic replacement process to conformally coat AuNPs on exposed AgNWs. (C) Sheet resistance (ohms/□) of the AuNP-AgNW/PDMS conductor under different levels of mechanical strain. The SEM images of the stretched conductor are shown at the bottom. (D) AFM surface topography (left) and phase mode (right) images of the P3HT-NF/PDMS film. (E) AFM phase mode images of P3HT-NF/PDMS coated on a PDMS substrate upon uniaxial stretching. Yellow arrows indicate P3HT-NF rupture. (F) Photographs of the P3HT-NF/PDMS film on a thin PDMS substrate under various forms of mechanical deformation. (G) Photographs of free-standing ion gel dielectric before and after stretching.CC BY-NC · PubMed Central
Fig. 2 Intrinsically stretchable rubbery transistors. (A) Exploded schematic illustration of the rubbery TFT. (B) Photograph of the TFT. (C) SEM image of the source, drain electrodes, and channel of the TFT. (D and E) Transfer and output curves of the TFT without any mechanical strain. (F and G) Transfer curves of the TFTs under different levels of mechanical strain along and perpendicular to the channel length directions. (H and I) μFE and Vth of the TFTs under different levels of mechanical strain along and perpendicular to the channel length directions.
Fig. 2 Intrinsically stretchable rubbery transistors. (A) Exploded schematic illustration of the rubbery TFT. (B) Photograph of the TFT. (C) SEM image of the source, drain electrodes, and channel of the TFT. (D and E) Transfer and output curves of the TFT without any mechanical strain. (F and G) Transfer curves of the TFTs under different levels of mechanical strain along and perpendicular to the channel length directions. (H and I) μFE and Vth of the TFTs under different levels of mechanical strain along and perpendicular to the channel length directions.CC BY-NC · PubMed Central
Fig. 3 Rubbery strain, pressure, and temperature sensors. (A) Exploded schematic illustration of the strain sensor. (B) Photographs of the sensors under different levels of mechanical strain. (C) Measured electrical resistance of the strain sensor under different levels of mechanical strain along the channel length direction (black) and perpendicular to the channel length direction (blue). (D) Relative change of the resistance (ΔR/Ro) under cyclic stretching and releasing. (E) GF of the strain sensor with respect to the different strain. (F) Relative electrical resistance (R/Ro) change of the pressure sensor with respect to time under different levels of pressure. (G) Relative electrical resistance change of the pressure sensor under a loading (red) and unloading (blue) cycle. (H) Relative electrical resistance change of the temperature sensor with respect to the different temperature.
Fig. 3 Rubbery strain, pressure, and temperature sensors. (A) Exploded schematic illustration of the strain sensor. (B) Photographs of the sensors under different levels of mechanical strain. (C) Measured electrical resistance of the strain sensor under different levels of mechanical strain along the channel length direction (black) and perpendicular to the channel length direction (blue). (D) Relative change of the resistance (ΔR/Ro) under cyclic stretching and releasing. (E) GF of the strain sensor with respect to the different strain. (F) Relative electrical resistance (R/Ro) change of the pressure sensor with respect to time under different levels of pressure. (G) Relative electrical resistance change of the pressure sensor under a loading (red) and unloading (blue) cycle. (H) Relative electrical resistance change of the temperature sensor with respect to the different temperature.CC BY-NC · PubMed Central
Fig. 4 Intrinsically stretchable rubbery electronics–based robotic skins. (A) Photographs of a robotic hand with intrinsically stretchable rubbery sensors. (B) Photograph of strain sensors located on the hinges of a robotic finger (left, top view) and overlapped photograph of the robotic finger with different bending angles from 0° to 90° (right, side view). (C) Electrical resistance of the strain sensor under different degrees of bending. (D) Demonstration of using an array of strain sensors on a robotic hand to translate sign language alphabets. The inset schematics of the colored hand are electrical resistance values that correspond to (C) for the corresponding hand gestures (see the Supplementary Materials and figs. S11 and S12 for details). (E) Photographs of the robotic hand with the temperature sensors touching hot (left) and cold (right) cups. (F) Measured sensor responses while the hand with skin touched the hot and cold cups alternatively.
Fig. 4 Intrinsically stretchable rubbery electronics–based robotic skins. (A) Photographs of a robotic hand with intrinsically stretchable rubbery sensors. (B) Photograph of strain sensors located on the hinges of a robotic finger (left, top view) and overlapped photograph of the robotic finger with different bending angles from 0° to 90° (right, side view). (C) Electrical resistance of the strain sensor under different degrees of bending. (D) Demonstration of using an array of strain sensors on a robotic hand to translate sign language alphabets. The inset schematics of the colored hand are electrical resistance values that correspond to (C) for the corresponding hand gestures (see the Supplementary Materials and figs. S11 and S12 for details). (E) Photographs of the robotic hand with the temperature sensors touching hot (left) and cold (right) cups. (F) Measured sensor responses while the hand with skin touched the hot and cold cups alternatively.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. K. L. Johnson Contact Mechanics (Cambridge Univ. Press 1987).

Cited by

See all 275

Metadata

Authors
Kim, H.-J., Sim, K., Thukral, A., & Yu, C.
Affiliations
University of Houston (US)
Corresponding author
Yu, Cunjiang
Venue
Science Advances
Published
2017-09
Volume
3
Issue
9
Pages
e1701114-e1701114
ISSN
2375-2548 (ISSN-L)
OpenAlex
W2753933330
Cited by
274
References
46
Citations by year
2026: 9 · 2025: 17 · 2024: 24 · 2023: 29 · 2022: 46 · 2021: 37 · 2020: 43 · 2019: 39 · 2018: 30
FWCI
13.79
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • Science Advances (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • Scholarworks@UNIST (Ulsan National Institute of Science and Technology) (submittedVersion)
Funders
  • National Science Foundation (award322310, ECCS-1509763, CMMI-1554499)
  • American Chemical Society Petroleum Research Fund (award322308, Doctoral New Investigator Grant)
  • Department of Mechanical Engineering at University of Houston (award322309, Bill D. Cook faculty scholarship)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
stretchable electronics, rubber composites, strain sensors, pressure sensors, temperature sensors, smart skin, gesture recognition, sign language, haptic sensing, robotics, semiconductors, conductors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.