The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Open accessAbstract
Label-free chemical contrast is highly desirable in biomedical imaging. Spontaneous Raman microscopy provides specific vibrational signatures of chemical bonds, but is often hindered by low sensitivity. Here we report a three-dimensional multiphoton vibrational imaging technique based on stimulated Raman scattering (SRS). The sensitivity of SRS imaging is significantly greater than that of spontaneous Raman microscopy, which is achieved by implementing high-frequency (megahertz) phase-sensitive detection. SRS microscopy has a major advantage over previous coherent Raman techniques in that it offers background-free and readily interpretable chemical contrast. We show a variety of biomedical applications, such as differentiating distributions of omega-3 fatty acids and saturated lipids in living cells, imaging of brain and skin tissues based on intrinsic lipid contrast, and monitoring drug delivery through the epidermis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Self-citation
Cited by
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Self-citationHollon, T. C., Pandian, B., Adapa, A. R., Urias, E., Save, A. V., Khalsa, S. S. S., Eichberg, D. G., D’Amico, R. S., Farooq, Z. U., Lewis, S., et al. (2020) · Nature Medicine · doi:10.1038/s41591-019-0715-9 · Cited by 790
Chemically sensitive bioimaging with coherent Raman scattering
Camp Jr, C. H., & Cicerone, M. T. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.60 · Cited by 472
Alkyne-Tag Raman Imaging for Visualization of Mobile Small Molecules in Live Cells
Yamakoshi, H., Dodo, K., Palonpon, A., Ando, J., Fujita, K., Kawata, S., & Sodeoka, M. (2012) · Journal of the American Chemical Society · doi:10.1021/ja308529n · Cited by 461
Rapid single-particle chemical imaging of nanoplastics by SRS microscopy
Qian, N., Gao, X., Lang, X., Deng, H., Bratu, T. M., Chen, Q., Stapleton, P., Yan, B., & Min, W. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2300582121 · Cited by 467
Self-citationIn vivo lipidomics using single-cell Raman spectroscopy
Wu, H., Volponi, J. V., Oliver, A. E., Parikh, A. N., Simmons, B. A., & Singh, S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1009043108 · Cited by 436
Biological imaging of chemical bonds by stimulated Raman scattering microscopy
Hu, F., Shi, L., & Min, W. (2019) · Nature Methods · doi:10.1038/s41592-019-0538-0 · Cited by 392
Self-citationImaging of EdU, an Alkyne-Tagged Cell Proliferation Probe, by Raman Microscopy
Yamakoshi, H., Dodo, K., Okada, M., Ando, J., Palonpon, A., Fujita, K., Kawata, S., & Sodeoka, M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja108404p · Cited by 356
Stimulated Raman Scattering: From Bulk to Nano
Prince, R. C., Frontiera, R. R., & Potma, E. O. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00545 · Cited by 350
Rodrigo, D., Tittl, A., Ait-Bouziad, N., John-Herpin, A., Limaj, O., Kelly, C., Yoo, D., Wittenberg, N. J., Oh, S.-H., Lashuel, H. A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04594-x · Cited by 269
Raman-guided subcellular pharmaco-metabolomics for metastatic melanoma cells
Du, J., Su, Y., Qian, C., Yuan, D., Miao, K., Lee, D., Ng, A. H. C., Wijker, R. S., Ribas, A., Levine, R. D., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18376-x · Cited by 171
Label‐Free Live‐Cell Imaging of Nucleic Acids Using Stimulated Raman Scattering Microscopy
Zhang, X., Roeffaers, M. B. J., Basu, S., Daniele, J. R., Fu, D., Freudiger, C. W., Holtom, G. R., & Xie, X. S. (2012) · ChemPhysChem · doi:10.1002/cphc.201100890 · Cited by 171
Self-citationPrediction of single-cell RNA expression profiles in live cells by Raman microscopy with Raman2RNA
Kobayashi-Kirschvink, K. J., Comiter, C. S., Gaddam, S., Joren, T., Grody, E. I., Ounadjela, J. R., Zhang, K., Ge, B., Kang, J. W., Xavier, R. J., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-02082-2 · Cited by 93
Self-citationShedding new light on lipid functions with CARS and SRS microscopy
Yu, Y., Ramachandran, P. V., & Wang, M. C. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2014.02.003 · Cited by 89
Zhang, Y., Chang, K., Ogunlade, B., Herndon, L., Tadesse, L. F., Kirane, A. R., & Dionne, J. A. (2024) · ACS Nano · doi:10.1021/acsnano.4c04282 · Cited by 83
An integrative Raman microscopy-based workflow for rapid in situ analysis of microalgal lipid bodies
Sharma, S. K., Nelson, D. R., Abdrabu, R., Khraiwesh, B., Jijakli, K., Arnoux, M., O’Connor, M. J., Bahmani, T., Cai, H., Khapli, S., et al. (2015) · Biotechnology for Biofuels · doi:10.1186/s13068-015-0349-1 · Cited by 80
Host and microbiota metabolic signals in aging and longevity
Zhou, Y., Hu, G., & Wang, M. C. (2021) · Nature Chemical Biology · doi:10.1038/s41589-021-00837-z · Cited by 70
He, X. N., Allen, J., Black, P. N., Baldacchini, T., Huang, X., Huang, H., Jiang, L., & Lu, Y. F. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002896 · Cited by 62
High-Speed Chemical Imaging by Dense-Net Learning of Femtosecond Stimulated Raman Scattering
Zhang, J., Zhao, J., Lin, H., Tan, Y., & Cheng, J.-X. (2020) · The Journal of Physical Chemistry Letters · doi:10.1021/acs.jpclett.0c01598 · Cited by 54
Microalgal detection by Raman microspectroscopy
Wei, X., Jie, D., Cuello, J. J., Johnson, D. J., Qiu, Z., & He, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.09.012 · Cited by 43
Multimodal Metabolic Imaging Reveals Pigment Reduction and Lipid Accumulation in Metastatic Melanoma
Lee, H. J., Chen, Z., Collard, M., Chen, F., Chen, J. G., Wu, M., Alani, R. M., & Cheng, J.-X. (2021) · BME Frontiers · doi:10.34133/2021/9860123 · Cited by 38
Multiscale Framework for Imaging Radiolabeled Therapeutics
Natarajan, A., Türkcan, S., Gambhir, S. S., & Pratx, G. (2015) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.5b00392 · Cited by 19
Metadata
- Authors
- Freudiger, C. W., Min, W., Saar, B. G., Lu, S., Holtom, G. R., He, C., Tsai, J. C., Kang, J. X., & Xie, X. S.
- Venue
- Science
- Published
- 2008-12-19
- Volume
- 322
- Issue
- 5909
- Pages
- 1857-1861
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2115318086
- Cited by
- 2,255
- References
- 1
- FWCI
- 42.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.