A neural interface provides long-term stable natural touch perception
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index; 5 of the 23 sources its claims cite were checked for support.
Abstract
Touch perception on the fingers and hand is essential for fine motor control, contributes to our sense of self, allows for effective communication, and aids in our fundamental perception of the world. Despite increasingly sophisticated mechatronics, prosthetic devices still do not directly convey sensation back to their wearers. We show that implanted peripheral nerve interfaces in two human subjects with upper limb amputation provided stable, natural touch sensation in their hands for more than 1 year. Electrical stimulation using implanted peripheral nerve cuff electrodes that did not penetrate the nerve produced touch perceptions at many locations on the phantom hand with repeatable, stable responses in the two subjects for 16 and 24 months. Patterned stimulation intensity produced a sensation that the subjects described as natural and without "tingling," or paresthesia. Different patterns produced different types of sensory perception at the same location on the phantom hand. The two subjects reported tactile perceptions they described as natural tapping, constant pressure, light moving touch, and vibration. Changing average stimulation intensity controlled the size of the percept area; changing stimulation frequency controlled sensation strength. Artificial touch sensation improved the subjects' ability to control grasping strength of the prosthesis and enabled them to better manipulate delicate objects. Thus, electrical stimulation through peripheral nerve electrodes produced long-term sensory restoration after limb loss.
Overview
CoChat Summary
TL;DR
Implanted nonpenetrating peripheral nerve cuff electrodes provided stable, natural touch sensations in the phantom hands of two upper-limb amputees for more than 1 year. Patterned stimulation intensity produced natural pressure, tapping, vibration, and moving touch, and sensory feedback improved grasping control and confidence.
Key findings
- Two subjects with upper limb amputation received implanted nerve cuff electrodes and reported stable touch percepts for 16 and 24 months; stimulation produced sensation from 19 of 20 channels at 15 unique locations in subject 1 and 14 of 16 channels at 9 unique locations in subject 2.
- Constant stimulation intensity typically produced paresthesia, described as “electrical,” in 96% of 151 trials over 10 months; time-variant pulse-width modulation instead produced perceptions described as natural, including pulsing pressure, constant pressure, light moving touch, tapping, and vibration.
- Perceived pressure intensity correlated with maximum pulse width (P < 0.05, R² = 0.85, n = 22), and matched pressure sensation correlated with log stimulation frequency in subject 1 (ANOVA, P < 0.05, R² = 0.70, n = 25).
- In a cherry-stem pulling task, success improved from 43% without sensory or audiovisual feedback to 93% with sensory feedback alone (P < 0.001, n = 15 per condition), and from 77% with audiovisual feedback alone to 100% with both (P < 0.005); self-reported confidence was higher with sensory feedback (one-tailed t test, P = 0.0305).
Methods
- Two male subjects with upper limb amputation received nonpenetrating peripheral nerve cuff electrodes: subject 1 had cuffs on median, radial, and ulnar nerves in the mid-forearm (20 channels total), and subject 2 had cuffs on median and radial nerves in the mid-upper arm (16 channels total).
- During monthly 4- to 6-hour visits, experimenters delivered trains of electrical pulses, identified sensory thresholds, and had subjects describe and trace perceived sensations on a hand schematic; stimulation parameters included pulse amplitude, pulse width, frequency, and time-variant pulse-width modulation.
- Functional testing included a cherry-stem pulling task under four sensory/audiovisual feedback conditions, force matching with a sensor, and pain surveys using the Trinity Amputation and Prosthesis Experience Scales (TAPES).
Limitations
- The study reports only two human subjects, so findings are based on a very small sample and no controlled comparison group.
- The paper states that the phantom pain findings “warrant more rigorous investigation” and that direct comparison with prior natural tactile sensation work is difficult because natural sensation had not been explicitly quantified or detailed.
- The paper notes that higher-density contact arrays may further improve hand coverage; the text also makes evident that many outcomes rely on subjective verbal reports, although some tests blinded subjects to stimulation level.
Model-written summary of a shortened version of the paper’s full text (it is longer than we read). Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
4 Valid · 1 Not valid · 12 Not checked · 82 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“Nerve electrodes activate populations of axons on the basis of size and location relative to the stimulating contact (23).”
What the sources say
- Supportedcites [23] matched to “Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode” (2012) source
In Methods §2.2 (page unavailable), the paper models axons with varying diameters and positions relative to a stimulating contact, then determines which propagate an action potential. Results §3.1 also describes the assumption that larger-diameter axons are recruited before smaller ones. Together, these passages support the paraphrase for the nerve electrode studied. (LLM, conf=0.88)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When the peak pulse width was set to a first noticeable level, B = Bth, the sensation was described as the back of a pen repeatedly pushing “very lightly” on a small, localized area of the skin (Fig. 3A).”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“There was a psychometric correlation between perceived intensity of the pressure pulse and the maximum pulse width.”
plainstates an associationn = 22 ·- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Of the 16 available channels implanted in subject 2, stimulation produced sensation from 14 channels at 9 unique locations (fig. S1).”
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The tapping matched the frequency of the intensity modulation, fmod, as fmod varied between 0.5 and 4 Hz.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
61 more claims
Create a free account to see all 99 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 24
- The quote only partly states this claim. 1
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It is proven that FINE and the spiral cuff electrode, when used for stimulation of the afferent axons, produce stable and somatotopically selective results in human subjects in long-term applications, providing appropriate sensory information to the prosthesis wearer [73].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [73]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Complex qualities of touch such as vibration on the skin, tingling, tapping, stinging, brushing, and itch have been observed during experimentation (Tan et al., 2014).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tan et al., 2014
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“and that long-term stability and selectivity has demonstrated using FINE (Ortiz-Catalan et al., 2014; Tan et al., 2014).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Tan et al., 2014
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Stimulation of the nerve has been shown to induce a variety of sensations with complex qualities, such as tapping on the skin, vibration, tingling, stinging, brushing, and itch (Clark et al., 2014;Tan et al., 2015;2014).”
From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Tan et al., 2014
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Differences in evoked sensations across electrodes likely reflect differences in the submodality distribution of afferents near the electrode, as evidenced by the fact that stimulation through electrodes with glabrous and non-glabrous receptive fields elicits distinct sensations, reflecting differences in the submodalities that innervate these skin regions (Tan et al., 2014).”
From Biomimetic approaches to bionic touch through a peripheral nerve interface (2015) · cites this paper as Tan et al., 2014
Experimental — accuracy not yet measured
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ 151 trials over a 10-month period. We systematically mapped the sensory perceptions
“When sensory feedback was not provided, the subject successfully plucked 43 and 77% of the cherries without (S−/AV−) or with (S−/AV+) audiovisual feedback, respectively.”
§ 151 trials over a 10-month period. We systematically mapped the sensory perceptions
“n = 15 per condition”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ RESULTS
“stimulation produced sensation from 19 channels at 15 unique locations on the perceived hand”
§ DISCUSSION
“There was independent control of 19 different locations on the hand with only three implanted cuffs”
Citations
Cites
Synaesthesia in phantom limbs induced with mirrors
(1996) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1996.0058 · Cited by 1,246
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415 · cited 2×
“Here, nonpenetrating peripheral nerve cuff electrodes (14, 15) were shown to provide multiple tactile perceptions at multiple locations on”
BackgroundMethodDouble nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396 · cited 4×
“There is mounting evidence that peripheral nerves are somatotopically organized (24–26), and hence, multi-channel cuff electrodes are able to produce somatotopically selective results similar to those reported in acute trials with intrafascicular electrodes (5, 12, 16).”
BackgroundResultInfluentialDhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 2×
“There is mounting evidence that peripheral nerves are somatotopically organized (24–26), and hence, multi-channel cuff electrodes are able to produce somatotopically selective results similar to those reported in acute trials with intrafascicular electrodes (5, 12, 16).”
ResultRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335 · cited 1×
“Sensory perception is important for control of the prosthetic limb, a sense of embodiment (3), and in the reduction of phantom limb pain (4, 5).”
BackgroundAugurelle, A.-S., Smith, A. M., Lejeune, T., & Thonnard, J.-L. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00249.2002 · Cited by 330
The Importance of the Sense of Touch in Virtual and Real Environments
Robles-De-La-Torre, G. (2006) · IEEE Multimedia · doi:10.1109/mmul.2006.69 · Cited by 311
PARÆSTHESIÆ FROM ECTOPIC IMPULSE GENERATION IN HUMAN SENSORY NERVES
OCHOA, J. L., & TOREJÖK, H. E. (1980) · Brain · doi:10.1093/brain/103.4.835 · Cited by 213
Horch, K., Meek, S., Taylor, T. G., & Hutchinson, D. T. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2162635 · Cited by 194 · cited 1×
“single-subject case studies (5, 18) and warrant more rigorous investigation into the benefits of sensory feedback and neural interfaces in the management of phantom pain.”
Background
Research works printed but not linked: 1
- C. D. Murray in Psychoprosthetics P. Gallagher D. Desmond M. MacLachlan Eds. (Springer London 2008) pp. 119–129.
Cited by
Items 501–600 of 746
Sensory integration for neuroprostheses: from functional benefits to neural correlates
Ding, K., Rakhshan, M., Paredes-Acuña, N., Cheng, G., & Thakor, N. V. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03118-8 · Cited by 7
“To this end, studies have introduced real-life objects with varying shape, fragility, and compliance so that the functional task difficulty matches with daily activity complexity [33, 56, 67, 89, 92].”
InfluentialPetros, E., Miller, M., Dunning, J. L., Pinault, G. C. J., Tyler, D. J., Triolo, R. J., & Charkhkar, H. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ada829 · Cited by 8
“This trend remained similar across participants and aligns with previously reported stable neural interfaces for sensory restoration [26, 27].”
InfluentialSelf-citationMulti-channel Electro-tactile Feedback System for a Prosthetic Hand
Ward, K., & Pamungkas, D. S. (2018) · Springer eBooks · doi:10.1007/978-3-319-76947-9_13 · Cited by 9
“Interfacing force sensors to the amputee is achieved either by surgically implanting electrodes that stimulate sensory nerves (see [7] and [8]), or through non-invasive feedback methods involving the use of vibrators [9], air pressure [10] or spatiallymapped tactile displays involving pressure, vibration, shear force…”
BackgroundLee, M. W., Jang, N., Choi, N., Yang, S., Jeong, J., Nam, H. S., Oh, S., Kim, K., & Hwang, D. (2021) · Advanced Science · doi:10.1002/advs.202102876 · Cited by 5
Classification of Sensory Neural Signals through Deep Learning Methods
Vasta, E., Coviello, A., Spagnolini, U., & Magarini, M. (2023) · IEEE EUROCON - International Conference on Computer as a Tool (EUROCON) · doi:10.1109/eurocon56442.2023.10199055 · Cited by 6
“Recent research has seen the development of neuro prostheses as interfaces with peripheral nerves to incorporate sensory feedback and recover the lost functionalities [2-4].”
BackgroundA hybrid sensory feedback system for thermal nociceptive warning and protection in prosthetic hand
Xie, A., Li, C., Chou, C.-H., Li, T., Dai, C., & Lan, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1351348 · Cited by 7
“…electrode (TIME) (Raspopovic et al., 2014), Utah slanted electrode array (USEA) (George et al., 2020), and flat interface nerve electrode (FINE) (Tan et al., 2014) not only enable the perception of contact forces but also help amputees identify object properties, such as size, compliance,…”
BackgroundRestoring Touch through Intracortical Microstimulation of Human Somatosensory Cortex
Flesher, S. N., Collinger, J. L., Weiss, J. M., Hughes, C. L., Bensmaïa, S. J., Boninger, M. L., & Gaunt, R. A. (2017) · IEEE International Conference on New Generation of Circuits and Systems (NGCAS) · doi:10.1109/ngcas.2017.68 · Cited by 8
“First, it shows that people with long-term injury to the spinal cord retain the ability to perceive sensations evoked through direct stimulation of the brain, just as amputees remain sensitive to electrical stimulation of peripheral nerves [9], [11], [12].”
BackgroundBertos, G. A., & Papadopoulos, E. G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812539-7.00006-4 · Cited by 8
What microsurgeon, orthopaedic and plastic surgeon should know about bionic hand
Bumbaširević, M., Lešić, A., Palibrk, T., Georgescu, A. V., Matei, I. R., Vučetić, Č., Pierluigi, T., Matić, S., Damjanovic, D., & Raspopović, S. (2019) · Injury · doi:10.1016/j.injury.2019.10.065 · Cited by 6
Millevolte, A. X. T., Dingle, A. M., Ness, J. P., Novello, J., Zeng, W., Lü, Y., Minor, R. L., Nemke, B. W., Markel, M. D., Suminski, A. J., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.613844 · Cited by 6
Electrodes for the Neural Interface
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00020-6 · Cited by 9
Self-citationPark, H., Klishko, A. N., Oh, K., Zhang, C., Grenga, G., Herrin, K. R., Dalton, J. F., Kistenberg, R. S., Lemay, M. A., Pitkin, M. R., et al. (2022) · Motor Control · doi:10.1123/mc.2022-0096 · Cited by 6
“We selected nerve stimulation parameters similar to those that evoked natural touch perception in the phantom hand or foot of human subjects with limb loss whose residual cutaneous and mixed nerves were electrically stimulated (Charkhkar et al., 2018; Tan et al., 2014).”
BackgroundMethodEarley, E. J., Johnson, R. E., Sensinger, J. W., & Hargrove, L. J. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01138-3 · Cited by 7
Benz, H. L., Sieff, T. R., Alborz, M., Kontson, K. L., Kilpatrick, E., & Civillico, E. F. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591783 · Cited by 6
“One approach to improving user experience and functionality with a prosthesis is the restoration of biomimetic sensory feedback [3-5].”
BackgroundKontogiannopoulos, S., Bertos, G. A., & Papadopoulos, E. G. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2980077 · Cited by 7
“The restoration of the sensory feedback improves the motor control in terms of sensorimotor, coordination and dexterity performance [20]–[23].”
BackgroundTemporal Modulation of Transcutaneous Electrical Nerve Stimulation Influences Sensory Perception
Dupan, S. S. G., McNeill, Z., Brunton, E., & Nazarpour, K. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176472 · Cited by 6
“The last decades have shown efforts to restore sensory feedback for people with upper limb differences through electrical [3–8] and tactile stimulation [9, 10].”
BackgroundThe intraneural electrical stimulation of human median nerve: a simulation study
Stefano, M., Cordella, F., & Zollo, L. (2020) · IEEE RO-MAN · doi:10.1109/ro-man47096.2020.9223448 · Cited by 5
“1Mattia Stefano, Francesca Cordella and Loredana Zollo are with Department of Engineering, Research Unit of Advanced Robotic and HumanCentred Technologies, Campus Bio-Medico University of Rome, 00128 Rome, Italy A possible solution for delivering sensations related to tactile feedback in upper limb neuroprostheses use…”
BackgroundElectrotactile Feedback for the Discrimination of Different Surface Textures Using a Microphone
Svensson, P., Antfolk, C., Björkman, A., & Malešević, N. (2021) · Sensors · doi:10.3390/s21103384 · Cited by 9
“The rationale for devising the transfer function was to shift the median frequencies of the audio signal to the range of stimulation frequencies that are commonly used for sensory/neural stimulation [35,36].”
BackgroundEEG Features of Evoked Tactile Sensation: Two Cases Study
Qin, C., Liang, W., Xie, D., Bi, S., & Chou, C.-H. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.904216 · Cited by 7
“Some scholars have proposed implanting invasive electrodes in the stump and stimulating the radial, ulnar, and median nerves to solve the sensory feedback problem (Raspopovic et al., 2014; Tan et al., 2014; Oddo et al., 2016), but this solution has the risk of infection that will not be accepted by most amputees.”
BackgroundPhantom Limbs and Brain Plasticity in Amputees
Makin, T. R., & Lab, L. P. (2020) · Oxford University Press eBooks · doi:10.1093/acrefore/9780190264086.013.50 · Cited by 7
Improving Upper-limb Prosthesis Usability: Cognitive Workload Measures Quantify Task DifficultyPreprint
Paskett, M. D., Garcia, J. K., Jones, S. T., Brinton, M. R., Davis, T. S., Duncan, C. C., Cooper, J. M., Strayer, D. L., & Clark, G. A. (2022) · medRxiv · doi:10.1101/2022.08.02.22278038 · Cited by 7
“Sophisticated solutions for restoring sensation (Tan et al., 2014; 72 Graczyk et al., 2018; D’Anna et al., 2019; George et al., 2019; Schofield et al., 2019; Mastinu et al., 73 2020), improving motor control (Ortiz-Catalan et al., 2014b; Hargrove et al., 2017; Ameri et al., 2019; 74 Salminger et…”
BackgroundValle, G., Katic, N., Eggemann, D., Gorskii, O., Pavlova, N., Čvančara, P., Stieglitz, T., Евгеньевич, М. П., Bumbaširević, M., & Raspopović, S. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.07.15.549130 · Cited by 6
“Similarly, it could explain why with simpler encoding (at the threshold level) the electrically-evoked sensation can be sometimes reported as natural 8,10,36,72 .”
BackgroundMethodInfluentialToward Natural Limb Function: A New Era in Prosthetic Innovation
Tian, Y., Wallace, D. M., Cederna, P. S., Chestek, C. A., & Kemp, S. W. P. (2025) · Annals of Neurology · doi:10.1002/ana.27287 · Cited by 8
“34 Raspopovic et al. also demonstrated that electrical stimulation of the median and ulnar nerve fascicles using transverse intrafascicular multichannel electrodes allowed a participant with a transradial amputation to volitionally modulate the grasping force of the neuroprosthesis without visual…”
InfluentialPaskett, M. D., Davis, T. S., Tully, T. N., Brinton, M. R., & Clark, G. A. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631087 · Cited by 5
“” The benefits of having sensory feedback in a prosthesis are already well established [3], [4], [11]; our main purpose in completing the fragile egg test here was to demonstrate a working closed-loop system.”
BackgroundAmin, K., & Fildes, J. E. (2022) · Frontiers in Surgery · doi:10.3389/fsurg.2022.873507 · Cited by 5
“Electrically stimulating a large population of afferents via a single electrode is unnatural and can evoke paresthesias (96).”
BackgroundJadidi, A. F., Jensen, W., Zarei, A. A., Lontis, R., & Atashzar, S. F. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1239068 · Cited by 6
“Dynamic recruitment of fibers due to varying pulse width leads to neural activation more similar to physiological signals resembling natural sensation, which is mentioned as a possible explanation for the more pleasant sensation experience (Tan et al., 2014).”
BackgroundDistally-referred surface electrical nerve stimulation (DR-SENS) for haptic feedback
Mesias, L., Gormez, M. A., Tyler, D. J., Makowski, N. S., Graczyk, E. L., & Fu, M. J. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad0563 · Cited by 5
Self-citationLeinen, M., Grandy, E. F., Gebel, L. M. U., Santana, T. M., Rodriguez, A. L., Singh, S. K., Fernandez, M. I., Dalugdug, J. C., Garcia-Colon, E. M., Lybeshari, K., et al. (2023) · Obesity Surgery · doi:10.1007/s11695-023-06957-w · Cited by 7
“In this study, we investigate the use of a novel VNS waveform that was adapted from one that was found to produce a sensation of pressure in the phantom fingers of upper extremity amputees [47–49].”
MethodResultSelf-citationConversion of a medical implant into a versatile computer-brain interface
Várkuti, B., Halász, L., Gooie, S. H., Miklós, G., Serena, R. S., van Elswijk, G., McIntyre, C. C., Lempka, S. F., Lozano, A. M., & Erőss, L. (2023) · Brain stimulation · doi:10.1016/j.brs.2023.12.011 · Cited by 6
“This can help users of prosthetic hands to better identify and manipulate objects [5 – 8], and has already been applied in real-world situations using chronic implants [9,10].”
BackgroundGenerating Frequency Selective Vibrations in Remote Moving Magnets
Masiero, F., Frazia, E. L., Ianniciello, V., & Cipriani, C. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202300751 · Cited by 7
On Biocompatibility and Stability of Transversal Intrafascicular Multichannel Electrodes—TIME
Stieglitz, T., Boretius, T., Čvančara, P., Guiraud, D., Guiho, T., López-Álvarez, V. M., & Navarro, X. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_120 · Cited by 7
“Different nerve interface concepts were recently investigated in subchronic and chronic clinical trials on the ulnar and median nerve: circumneural cuff-electrodes [1], micro-machined intraneural needle arrays [2] and flexible, polymer-based intrafascicular electrodes [3].”
A handheld device for magnetically inserting a neural interface into a peripheral nervous system
Yim, S., Hwang, D., Ihn, Y. S., Jeong, J., Oh, S.-R., & Kim, K. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036803 · Cited by 5
“Neuroprosthetic devices have been studied for many years as a new method to restore motor functions in paralyzed limbs [1-3] and/or to interconnect amputee with robotic limbs [4-5].”
MethodOrganic Electronics for Artificial Touch
Black, C. J., Darie, R., & Borton, D. A. (2018) · Trends in Neurosciences · doi:10.1016/j.tins.2018.07.010 · Cited by 5
Urbin, M. A., Liu, M., Bottorff, E. C., Gaunt, R. A., Fisher, L. E., & Weber, D. J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4c6c · Cited by 6
Distinct perceptive pathways selected with tonic and bursting patterns of thalamic stimulation
Willsey, M. S., Lu, C. W., Nason, S. R., Malaga, K. A., Lempka, S. F., Chestek, C. A., & Patil, P. G. (2020) · Brain stimulation · doi:10.1016/j.brs.2020.07.007 · Cited by 5
Clinical Basis for Creating an Osseointegrated Neural Interface
Karczewski, A. M., Zeng, W., Stratchko, L. M., Bachus, K. N., Poore, S. O., & Dingle, A. M. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.828593 · Cited by 5
Prosthetic Limb Attachment via Electromagnetic Attraction Through a Closed Skin Envelope
Flanagan, W., Becraft, K., Warren, H. R., Stavrakis, A. I., Bernthal, N. M., Hardin, T. J., & Clites, T. R. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3342652 · Cited by 6
Compliant adhesive cuff electrode for selective stimulation in rat vagus nerve
Forssell, M., Sciullo, M., Mou, C., Sun, F., Simpson, T. W., Xiao, G., Fisher, L. E., Bettinger, C. J., Horn, C. C., & Fedder, G. K. (2019) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors43011.2019.8956853 · Cited by 4
“Traditionally, a single contact within the cuff wrapped the entire circumference of the nerve, limiting selectivity, although many studies have demonstrated improvements by using multiple independent electrodes around the nerve [4][5][6].”
BackgroundSimilar trial-by-trial adaptation behavior across transhumeral amputees and able-bodied subjects
Johnson, R. E., Kording, K. P., Hargrove, L. J., & Sensinger, J. W. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146737 · Cited by 5
Nanivadekar, A. C., Bose, R., Petersen, B. A., Okorokova, E. V., Sarma, D., Farooqui, J., Dalrymple, A. N., Levy, I., Helm, E. R., Mièle, V., et al. (2022) · medRxiv · doi:10.1101/2022.09.15.22279956 · Cited by 8
Phantom limb syndrome: from pathogenesis to treatment. A narrative review
Granata, G., Iorio, R., Ilari, S., Angeloni, B. M., Tomasello, F., Cimmino, A. T., Carrarini, C., Marrone, A., & Iodice, F. (2024) · Neurological Sciences · doi:10.1007/s10072-024-07634-1 · Cited by 13
“Finally, similar results were obtained with particular epineural electrodes, known as the flat interface nerve electrode (FINE) [62, 63].”
Hutchison, B. C., Bose, R., Spilker, B. J., Bhat, P., Memberg, W. D., Ketting-Olivier, A., Herring, E., Sweet, J. A., Miller, J. P., Kirsch, R. F., et al. (2025) · medRxiv · doi:10.1101/2025.08.20.25334094 · Cited by 5
Hybrid neural autoencoders for stimulus encoding in visual and other sensory neuroprostheses
Granley, J., Relic, L., & Beyeler, M. (2022) · Advances in Neural Information Processing Systems 35 · doi:10.52202/068431-1647 · Cited by 5
“In such devices, diminished sensory modalities (e.g., hearing [3], vision [4, 5], cutaneous touch [6]) are re-enacted through streams of artificial input to the nervous system.”
Hand prostheses with somatosensory feedback: functional and clinical benefits
Shokur, S., Bassolino, M., Kang, N., Ackerley, R., & Micera, S. (2026) · The Lancet Neurology · doi:10.1016/s1474-4422(25)00493-4 · Cited by 8
Thomas, N., Osborn, L. E., Moran, C. W., Fifer, M. S., & Christie, B. P. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1490828 · Cited by 5
Artificial nerve systems for use in bio-interactive prostheses
Kim, C. H., Seo, D., Lee, Y., & Lee, T. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00197-z · Cited by 6
Remapping Wetness Perception in Upper Limb Amputees
Ploumitsakou, M., Muheim, J., Felouzis, A., Muñoz, N. C., Iberite, F., Akouissi, O., Morosato, F., Gruppioni, E., Filingeri, D., Micera, S., et al. (2024) · Advanced Intelligent Systems · doi:10.1002/aisy.202300512 · Cited by 4
Tebcherani, T. M., Loparo, K. A., Kaffashi, F., Tyler, D. J., & Graczyk, E. L. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3414939 · Cited by 5
“However, clinical neurostimulation is typically applied via single electrode contacts, where one contact is stimulated per target muscle or sensory percept [4], [5], [6], [7], [8], [11], [12], [15], [16], [17], [18].”
BackgroundMethodInfluentialSelf-citationYing, Z., Zhang, X., Li, S., Nakashima, K., Shu, L., & Sugita, N. (2024) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra57147.2024.10611356 · Cited by 6
Sensing texture using an artificial finger and a data analysis based on the standard deviation
Chappell, P. H., Muridan, N., Hanif, N. H. H. M., Cranny, A., & White, N. M. (2015) · IET Science Measurement & Technology · doi:10.1049/iet-smt.2015.0003 · Cited by 6
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode
Koh, R. G. L., & Zariffa, J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591713 · Cited by 6
“The nerve cuff electrode [1]-[3] is one such device that may be useful for this purpose as it has been shown to be safe for chronic implantation in humans [4]-[6].”
BackgroundOverstreet, C. K., Hellman, R. B., Wong, R. D. P., Santos, V. J., & Tillery, S. I. H. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00091 · Cited by 4
“org December 2016 | Volume 4 | Article 91 that interfaces with peripheral nerves can provide a robust and stable sensory percept that is useful for movement (Ortiz-Catalan et al., 2014; Raspopovic et al., 2014; Tan et al., 2014; Oddo et al., 2016).”
BackgroundRestoration of somatosensory perception via electrical stimulation of peripheral nerves
Ortiz-Catalan, M. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.008 · Cited by 5
“Whereas it is currently possible to elicit long-term stable, intuitive percepts (Graczyk et al., 2016; Ortiz-Catalan et al., 2014; Tan et al., 2014), the challenge of providing a completely natural sensory experience persists.”
BackgroundHandheld Nerve Electrode Insertion Tool
Yim, S., Oh, Y.-E., Jeong, J., Ihn, Y. S., Hwang, D., Oh, S., & Kim, K. (2018) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2018.2864978 · Cited by 4
“Neuroprosthetic devices are studied as a new method to restore motor functions in paralyzed limbs [1]–[6] and/or interconnect amputee with robotic limbs [7]–[12].”
Finger Tapping Outperforms the Traditional Scale in Patients With Peripheral Nerve Damage
Zhang, L., Lei, L., Zhao, Y., Wang, R., Zhu, Y., Yu, Z., & Zhang, X. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01361 · Cited by 7
“Keywords: peripheral nerve, affected hand, dominant hand, finger tapping, Lind-mark INTRODUCTION Touch perception in the finger is an indispensable part of fine motor control, which helps contribute to the sense of self, communication, and a clear perception of the world (Tan et al., 2014).”
BackgroundTowards a high precision robotic platform for neural interface implantation
Jeong, J., Yim, S., Hwang, D., Oh, S., Kim, K., & Ihn, Y. S. (2018) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2018.8612253 · Cited by 4
“Recently, there has been growing interest in neural prosthetic limbs that are directly controlled by neural interfaces implanted in amputee [1-12].”
BackgroundA Computer-Brain Interface that Restores Lost Extremities’ Touch and Movement Sensations
Valle, G., Petrini, F. M., Mijović, P., Mijović, B., & Raspopović, S. (2021) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-79287-9_7 · Cited by 5
EEG guided electrical stimulation parameters generation from texture force profiles
Eldeeb, S. M., & Akçakaya, M. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/aca82e · Cited by 4
Osumi, M., Sumitani, M., Otake, Y., Nishi, Y., Nobusako, S., & Morioka, S. (2022) · Experimental Brain Research · doi:10.1007/s00221-022-06532-2 · Cited by 4
Pan, L., Ren, Z., Zhu, K., & Li, J. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02923-x · Cited by 4
“Tan et al. implanted the nerve cuff electrodes in the peripheral nervous syste and evoked the tactile sensations in the hand [16, 17].”
Reduced genioglossus muscle activity caused by fluid overload in anesthetized rats
Sabetian, P., Yadollahi, A., & Yoo, P. B. (2020) · Physiological Reports · doi:10.14814/phy2.14445 · Cited by 4
“Our findings are consistent with previous work which show that increases in blood pressure result in reduced diaphragm activity and total ventilation (Metcalfe, Chew, Clarke, de Donaldson, & Taylor, 2015; Salamone, Strohl, Weiner, Mitra, & Cherniack, 1983; Tan et al., 2014), though it remains unclear whether saline in…”
BackgroundImplantable Device Fabrication and Packaging
Stieglitz, T. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_102-1 · Cited by 6
Page, D. M. (2018) · J. Willard Marriott Library · doi:10.26053/0h-883s-cmg0 · Cited by 4
Validation of a constrained-time movement task for use in rehabilitation outcome measures
Blustein, D. H., & Sensinger, J. W. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009410 · Cited by 4
Preliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4
“Neural electrodes enable the restoration of motor functions in paralyzed limbs [1-6] and the interconnection of amputee with neuroprosthetic limbs [7-12].”
BackgroundBatteryless Pelvic Nerve Direct Modulation for Bladder Voding Using an Active Neural Clip
Lee, S., Peh, W. Y. X., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2018) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2018.8556942 · Cited by 4
“Modulation of neural activity with implantable bioelectronics is a potentially powerful way to control neuroprostheses [1-3], regulate physiological function, and restore health [4].”
BackgroundDingle, A. M., Ness, J. P., Novello, J., Zeng, W., Millevolte, A. X. T., Minor, R. L., Kegal, J., Lü, Y., Nemke, B. W., Markel, M. D., et al. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716957 · Cited by 5
“This is most commonly achieved in humans through lead wires penetrating skin [7].”
BackgroundNeural Implants Without Electronics: A Proof-of-Concept Study on a Human Skin Model
Kiele, P., Braig, D., Weis, J., Baslan, Y., Pasluosta, C. F., & Stieglitz, T. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.2981254 · Cited by 5
“[25], 1–100 μA (tingle, pressure, vibration, hair and air brush cold) [3] to amplitudes up to 2 mA (touch) [26].”
BackgroundEnhancing human computer interaction with electrotactile feedback
Pamungkas, D. S. (2016) · Research Online (University of Wollongong) · Cited by 5
Chronic use of a sensitized bionic hand does not remap the sense of touchPreprint
Ortiz-Catalan, M., Mastinu, E., & Bensmaı̈a, S. J. (2020) · medRxiv · doi:10.1101/2020.05.02.20089185 · Cited by 4
Galletta, V., Bonato, M., Parazzini, M., Chiaramello, E., & Fiocchi, S. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00187-4 · Cited by 6
Time series classification of multi-channel nerve cuff recordings using deep learning
Gill, A. P. S., & Zariffa, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0299271 · Cited by 3
Doan, H., Tavasoli, S., 서강, Park, H., Park, H., & Roh, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-86342-y · Cited by 4
Experimental analysis of the relationship between neural and muscular recordings during hand control
Noce, E., Zollo, L., Davalli, A., Sacchetti, R., & Guglielmelli, E. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523779 · Cited by 3
“it There is clear evidence in the literature [6] [7] [8] [9] that through neural electrodes it is possible to return a sensory feedback by stimulating the Peripheral Nervous System (PNS) and activating the sensory fascicles of the nerves.”
BackgroundTang, R., Lv, X., Sun, W., Dai, C., Zhang, M., Li, X., She, H., Zhang, X., Lang, Y., Zhu, J., et al. (2017) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2017.8266089 · Cited by 4
“Invasive neural interface was also used for medical purpose by providing assistance, monitoring, diagnosis or therapy to patients, such as amputees, paralytics, and those suffering from nerve injury, diseases or limb loss [11]-[18].”
MethodArtificial Sensory Feedback to the Brain: Somatosensory Feedback for Neural Devices and BCI
Bjånes, D. A., & Moritz, C. T. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_111-2 · Cited by 4
How Fast Is Too Fast? Boundaries to the Perception of Electrical Stimulation of Peripheral Nerves
Dupan, S. S. G., McNeill, Z., Sarda, E., Brunton, E., & Nazarpour, K. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3158067 · Cited by 2
“When focusing on fs , an analysis of previous literature on sensory feedback for limb prostheses shows that studied stimulation paradigms mostly include frequencies under 200 Hz [7], [19]–[24], but some go up to 500 Hz [9], [10], [25] or even 1000 Hz [16].”
BackgroundInfluentialManoharan, S., Oh, S., Jiang, B., Patton, J. L., & Park, H. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871592 · Cited by 3
“Multiple studies of sensory neuroprosthesis with amputee subjects demonstrated that electrical stimulation onto the residual cutaneous nerves successfully replicates the tactile feedback from the fingertip or the foot sole [4]-[6].”
BackgroundGonzalez, M. A., Vu, P. P., Vaskov, A. K., Cederna, P. S., Chestek, C. A., & Gates, D. H. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896481 · Cited by 7
The Hand After Stroke and SCI: Restoration of Function with Technology
Ghassemi, M., & Kamper, D. G. (2022) · Springer eBooks · doi:10.1007/978-3-031-08995-4_6 · Cited by 4
Anatomics: Co-engineering body and machine in pursuit of synergistic bionic performance
Clites, T. R. (2023) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2023.100490 · Cited by 3
Automated Quantifiable Assessments of Sensorimotor Function Using an Instrumented Fragile Object
Adkins, M. D., Buczak, M. K., Olsen, C. D., Iversen, M. M., & George, J. A. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304693 · Cited by 3
Malešević, N., Lindén, F., Fureby, L., Rudervall, C., Björkman, A., & Antfolk, C. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad10d0 · Cited by 3
“By using invasive techniques it is possible to target a subset of nerve fibers within a nerve, leading to moderate success in producing several different somatotopic sensations on the skin [18, 19, 21, 26].”
BackgroundMethodResultIntroduction: The World of Touch
Prescott, T. J., & Dürr, V. (2015) · Atlantis Press eBooks · doi:10.2991/978-94-6239-133-8_1 · Cited by 4
Lee, S., Wang, H., Shi, Q., Wang, J., He, T., Wu, H., Thakor, N. V., Yen, S., & Lee, C. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994420 · Cited by 2
“Neuromodulation of peripheral nerves with implantable bioelectronics is a powerful way to control artificial prostheses [1-3] or physiological function [4-6].”
BackgroundRestoring the sense of touch with electrical stimulation of the nerve and brain
Callier, T., & Bensmaïa, S. J. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00010-1 · Cited by 3
A scalable, high resolution strain sensing matrix suitable for tactile transduction
Scibelli, A. E., & Krans, J. L. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.056 · Cited by 3
“slipping) of grasped objects (Tan et al., 2014).”
BackgroundWeir, R. F. F. (2017) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000161 · Cited by 3
“Sensory nerve interfaces are in human trials for the first time, and the results are exciting.(35,95,96) With appropriate sensory stimulation of the peripheral nerves, individuals believe they are touching something.”
BackgroundSchiefer, M. A., Gamble, J. E., & Strohl, K. P. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00225.2018 · Cited by 3
“5 mA, was one that we know elicits no or minimal sensory response and certainly not pain in awake humans using similar nerve cuff electrodes (27, 28).”
MethodSelf-citationAutomatic hand phantom map generation and detection using decomposition support vector machines
Huang, H., Bruschini, C. E., Antfolk, C., Enz, C., Li, T., Justiz, J., & Koch, V. M. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0502-8 · Cited by 4
“The invasive approach stimulates the central nervous system using cortical electrodes [6] or the peripheral nervous system using either cuff electrodes [7, 8] or transversal intrafascicular multichannel electrodes [9].”
An Intraoral Closed-Loop Monitoring and Stimulation System for Treatment of Swallowing Problems
Biyani, S., Biswas, S., & Park, H. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717139 · Cited by 3
“The series resistance for the sensory perception threshold was determined ahead for each subject by gradually decreasing the series resistance until the subject reported any sensation [17].”
BackgroundMethodLienkämper, R., Dyck, S., Saif-ur-Rehman, M., Metzler, M., Ali, O., & Klaes, C. (2021) · Scientific Reports · doi:10.1038/s41598-021-84288-5 · Cited by 8
Touch restoration through electrical cortical stimulation in humans
Caldwell, D. J., Cronin, J. A., Levinson, L. H., & Rao, R. P. N. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00021-6 · Cited by 4
Yang, S., Zhong, S., Jin, X., Fan, G., Liao, X., Yang, X., & He, S. (2023) · International Wound Journal · doi:10.1111/iwj.14511 · Cited by 3
“49,50 Davis TS et al., discovered that electrical stimulation not only provides sensory feedback, but also regulates prosthetic limb activity, paving the way for the development of more advanced nerve stimulation-based prostheses with bidirectional communication.”
BackgroundHuman psychophysics of direct cortical stimulation of somatosensory cortex
Cronin, J. A. (2018) · ResearchWorks at the University of Washington (University of Washington) · Cited by 4
Wearable neuroprosthesis improves mobility and reduces pain in neuropathic participantsPreprint
Gozzi, N., Chee, L., Odermatt, I., Kikkert, S., Preatoni, G., Valle, G., Pfender, N., Beuschlein, F., Wenderoth, N., Zipser, C. M., et al. (2024) · medRxiv · doi:10.1101/2024.05.08.24306164 · Cited by 3
“Near-natural tactile sensation has been achieved only through invasive neural technologies both at the peripheral level ( 22 , 25 , 67 ), and at the central level ( 68 – 70 ).”
BackgroundHomo Putans: Supposing and Existence
Büyükbay, C. (2025) · Integrative Psychological and Behavioral Science · doi:10.1007/s12124-025-09897-5 · Cited by 3
“Advanced neural interfaces transmit tactile and pressure signals from prosthetic hands to the nervous system and enables the brain to interpret these inputs as genuine sensations (Collinger et al., 2013; Tan et al., 2014).”
Abayazid, M. (2026) · Sensors · doi:10.3390/s26154824 · Cited by 3
“These systems have shown stable sensory feedback and improved prosthetic control, and users often report enhanced embodiment of the prosthetic limb [79,80].”
Somatosensory Neuromodulation with a Focus Towards Clinical Systems
Graczyk, E. L., & Tyler, D. J. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_92-1 · Cited by 2
Self-citationZhang, J., Chou, C.-H., Hao, M., Li, Y., Yu, Y., & Lan, N. (2023) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2023.1298176 · Cited by 3
“…referred to the missing hand (Lawrence et al., 2004; Polasek et al., 2009; Boretius et al., 2010; Sharma et al., 2011; Antfolk et al., 2012; Ortiz-Catalan et al., 2014; Tan et al., 2014; Chai et al., 2015; D’Anna et al., 2017; Shin et al., 2018; Marasco et al., 2021; Zhang et al., 2022b).”
Background
Metadata
- Authors
- Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J.
- Affiliations
- Louis Stokes Cleveland VA Medical Center (US)
- MetroHealth Medical Center (US)
- Corresponding author
- Tan, Daniel W.
- Schiefer, Matthew A.
- Tyler, Dustin J.
- Venue
- Science Translational Medicine
- Published
- 2014-10-08
- Volume
- 6
- Issue
- 257
- Pages
- 257ra138-257ra138
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- PMC
- PMC5517305
- OpenAlex
- W2157094999
- Semantic Scholar
- 308d067b912e90f2bd3958d5248e2d960435ea5c
- Cited by
- 751
- References
- 29
- Citations by year
- 2026: 24 · 2025: 41 · 2024: 57 · 2023: 59 · 2022: 81 · 2021: 75 · 2020: 74 · 2019: 87 · 2018: 82 · 2017: 64 · 2016: 64 · 2015: 37 · 2014: 5
- FWCI
- 25.89
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01 RX001334, IK1 RX000724)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
- Keywords
- peripheral nerve interfaces, electrical stimulation, tactile perception, upper limb amputation, prosthetic hand, sensory feedback, phantom hand, long-term stability, paresthesia, grasp control, fine motor control, sensory recovery
- MeSH terms
- Amputees, Artificial Limbs, Electric Stimulation, Electrodes, Implanted, Hand, Humans, Male, Middle Aged, Motor Skills, Paresthesia, Peripheral Nerves, Phantom Limb, Pressure, Sensation, Touch Perception, Feedback, Sensory, Translational Research, Biomedical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.