Advances in Imaging Secondary Ion Mass Spectrometry for Biological Samples
Open accessThe DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
Imaging mass spectrometry combines the power of mass spectrometry to identify complex molecules based on mass with sample imaging. Recent advances in secondary ion mass spectrometry have improved sensitivity and spatial resolution, so that these methods have the potential to bridge between high-resolution structures obtained by X-ray crystallography and cyro-electron microscopy and ultrastructure visualized by conventional light microscopy. Following background information on the method and instrumentation, we address the key issue of sample preparation. Because mass spectrometry is performed in high vacuum, it is essential to preserve the lateral organization of the sample while removing bulk water, and this has been a major barrier for applications to biological systems. Recent applications of imaging mass spectrometry to cell biology, microbial communities, and biosynthetic pathways are summarized briefly, and studies of biological membrane organization are described in greater depth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967 · cited 1×
“In particular the works of Hell and coworkers (46, 47, 55, 95, 96, 109) have demonstrated resolution better than 100 nm.”
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Saxena, S. K., & Fei, Y. (1988) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(88)90314-6 · Cited by 1,758
Multicolor Super-Resolution Imaging with Photo-Switchable Fluorescent Probes
Bates, M., Huang, B., Dempsey, G. T., & Zhuang, X. (2007) · Science · doi:10.1126/science.1146598 · Cited by 1,504
The State of Lipid Rafts: From Model Membranes to Cells
Edidin, M. (2003) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.32.110601.142439 · Cited by 1,341
Analysis of Proteins and Proteomes by Mass Spectrometry
Mann, M., Hendrickson, R. C., & Pandey, A. (2001) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.70.1.437 · Cited by 1,219
Cited by
Microbial syntrophy: interaction for the common good
Morris, B. E. L., Henneberger, R., Huber, H., & Moissl-Eichinger, C. (2013) · FEMS Microbiology Reviews · doi:10.1111/1574-6976.12019 · Cited by 920
In Situ Imaging of Metals in Cells and Tissues
McRae, R., Bagchi, P., Sumalekshmy, S., & Fahrni, C. J. (2009) · Chemical Reviews · doi:10.1021/cr900223a · Cited by 570
Fluorescent Probes for Lipid Rafts: From Model Membranes to Living Cells
Klymchenko, A. S., & Kreder, R. (2014) · Chemistry & Biology · doi:10.1016/j.chembiol.2013.11.009 · Cited by 514
Innovative methods in soil phosphorus research: A review
Kruse, J., Abraham, M., Amelung, W., Baum, C., Bol, R., Kühn, O., Lewandowski, H., Niederberger, J., Oelmann, Y., Rüger, C., et al. (2015) · Journal of Plant Nutrition and Soil Science · doi:10.1002/jpln.201400327 · Cited by 386
Mass spectrometry‐based plant metabolomics: Metabolite responses to abiotic stress
Jorge, T. F., Rodrigues, J. A., Caldana, C., Schmidt, R., van Dongen, J. T., Thomas‐Oates, J., & António, C. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21449 · Cited by 376
Mass spectrometry imaging with high resolution in mass and space
Römpp, A., & Spengler, B. (2013) · Histochemistry and Cell Biology · doi:10.1007/s00418-013-1097-6 · Cited by 358
Imaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Lipid imaging with time-of-flight secondary ion mass spectrometry (ToF-SIMS)
Passarelli, M. K., & Winograd, N. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.007 · Cited by 314
Metabolomics and mass spectrometry imaging reveal channeled de novo purine synthesis in cells
Pareek, V., Tian, H., Winograd, N., & Benkovic, S. J. (2020) · Science · doi:10.1126/science.aaz6465 · Cited by 307
Unsupervised machine learning for exploratory data analysis in imaging mass spectrometry
Verbeeck, N., Caprioli, R. M., & Van de Plas, R. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21602 · Cited by 281
Mass spectrometry imaging for drug distribution studies
Prideaux, B., & Stoeckli, M. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.07.028 · Cited by 279
Palaniappan, K. K., & Bertozzi, C. R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00023 · Cited by 278
Eberlin, L. S., Ferreira, C. R., Dill, A. L., Ifa, D. R., & Cooks, R. G. (2011) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2011.05.006 · Cited by 257
Analysis of cholesterol trafficking with fluorescent probes
Maxfield, F. R., & Wüstner, D. (2012) · Methods in Cell Biology · doi:10.1016/b978-0-12-386487-1.00017-1 · Cited by 240
Detecting metabolic activities in single cells, with emphasis on nanoSIMS
Musat, N., Foster, R., Vagner, T., Adam, B., & Kuypers, M. M. M. (2012) · FEMS Microbiology Reviews · doi:10.1111/j.1574-6976.2011.00303.x · Cited by 234
“SIMS is based on the mass spectrometry of secondary ions extracted from the surface of a solid sample under the impact of an energetic beam of primary ions (Guerquin-Kern et al. , 2005; Boxer et al. , 2009).”
BackgroundMethodInfluentialMALDI‐imaging mass spectrometry – An emerging technique in plant biology
Kaspar, S., Peukert, M., Svatos, A., Matros, A., & Mock, H. (2011) · PROTEOMICS · doi:10.1002/pmic.201000756 · Cited by 225
“Although MALDI utilizes a laser to desorb molecules within a matrix, SIMS sputters the sample surface by means of a focussed Ar(1), Ga(1), or In(1) beam and captures the ejected compoundspecific secondary ions [18].”
BackgroundLook@NanoSIMS – a tool for the analysis of nanoSIMS data in environmental microbiology
Polerecky, L., Adam, B., Milucka, J., Musat, N., Vagner, T., & Kuypers, M. M. M. (2012) · Environmental Microbiology · doi:10.1111/j.1462-2920.2011.02681.x · Cited by 221
NanoSIMS for biological applications: Current practices and analyses
Nuñez, J., Renslow, R., Cliff, J. B., & Anderton, C. R. (2018) · Biointerphases · doi:10.1116/1.4993628 · Cited by 211
Mass spectrometry imaging and profiling of single cells
Lanni, E. J., Rubakhin, S. S., & Sweedler, J. V. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.03.017 · Cited by 201
“[22] covers SIMS fundamentals and thoroughly examines broader biological applications.”
BackgroundDirect chemical evidence for sphingolipid domains in the plasma membranes of fibroblasts
Frisz, J. F., Lou, K., Klitzing, H. A., Hanafin, W. P., Lizunov, V., Wilson, R. L., Carpenter, K. J., Kim, R., Hutcheon, I. D., Zimmerberg, J., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1216585110 · Cited by 196
Self-citationEberlin, L. S., Ifa, D. R., Wu, C., & Cooks, R. G. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906283 · Cited by 187
Deleu, M., Crowet, J.-M., Nasir, M. N., & Lins, L. (2014) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2014.08.023 · Cited by 185
Ackerman, C. M., Lee, S., & Chang, C. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04631 · Cited by 177
Correlative Super-Resolution Microscopy: New Dimensions and New Opportunities
Hauser, M., Wojcik, M., Kim, D., Mahmoudi, M., Li, W., & Xu, K. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00604 · Cited by 176
Comi, T. J., Do, T. D., Rubakhin, S. S., & Sweedler, J. V. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.6b12822 · Cited by 171
Trace metal imaging with high spatial resolution: Applications in biomedicine
Qin, Z., Caruso, J. A., Lai, B., Matusch, A., & Becker, J. S. (2011) · Metallomics · doi:10.1039/c0mt00048e · Cited by 169
Intramyocellular lipid droplets and insulin sensitivity, the human perspective
Gemmink, A., Goodpaster, B. H., Schrauwen, P., & Hesselink, M. K. C. (2017) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2017.07.010 · Cited by 62
Metadata
- Authors
- Boxer, S. G., Kraft, M. L., & Weber, P. K.
- Venue
- Annual Review of Biophysics
- Publisher
- Annual Reviews
- Published
- 2009-06-01
- Volume
- 38
- Issue
- 1
- Pages
- 53-74
- ISSN
- 1936-122X (ISSN-L)
- 1936-1238
- OpenAlex
- W2119080963
- Cited by
- 308
- References
- 75
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.