Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
The DOI matches its Crossref record.
Abstract
Intravoxel incoherent motion (IVIM) imaging is a method the authors developed to visualize microscopic motions of water. In biologic tissues, these motions include molecular diffusion and microcirculation of blood in the capillary network. IVIM images are quantified by an apparent diffusion coefficient (ADC), which integrates the effects of both diffusion and perfusion. The aim of this work was to demonstrate how much perfusion contributes to the ADC and to present a method for obtaining separate images of diffusion and perfusion. Images were obtained at 0.5 T with high-resolution multisection sequences and without the use of contrast material. Results in a phantom made of resin microspheres demonstrated the ability of the method to separately evaluate diffusion and perfusion. The method was then applied in patients with brain and bone tumors and brain ischemia. Clinical results showed significant promise of the method for tissue characterization by perfusion patterns and for functional studies in the evaluation of the microcirculation in physiologic and pathologic conditions, as, for instance, in brain ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Items 101–141 of 141
Chandarana, H., Lee, V. S., Hecht, E., Taouli, B., & Sigmund, E. E. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181ffc485 · Cited by 188
Utility of diffusion‐weighted MRI in distinguishing benign and malignant hepatic lesions
Miller, F. H., Hammond, N., Siddiqi, A. J., Shroff, S., Khatri, G., Wang, Y., Merrick, L. B., & Nikolaidis, P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22235 · Cited by 188
“2 ( 10 3 mm(2)/second) at room temperature, which are consistent with those reported in the literature (3,7,8,27,28).”
ResultBastin, M. E., Armitage, P. A., & Marshall, I. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00098-8 · Cited by 188
Diffusion MRI of the breast: Current status and future directions
Iima, M., Honda, M., Sigmund, E. E., Ohno Kishimoto, A., Kataoka, M., & Togashi, K. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26908 · Cited by 187
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
Self-citationFunctional Magnetic Resonance Imaging with Echo Planar Imaging
Kwong, K. K. (1996) · Functional MRI · doi:10.1007/978-88-470-2194-5_16 · Cited by 184
Panagiotaki, E., Chan, R. W., Dikaios, N., Ahmed, H. U., O’Callaghan, J., Freeman, A., Atkinson, D., Punwani, S., Hawkes, D. J., & Alexander, D. C. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000115 · Cited by 184
“Intravoxel incoherent motion characterizes water dispersion as a combination of a slow component associated with Brownian motion and a fast component associated with the bulk motion of molecules inside microcapillaries.(14,15) It has been used to study various cancer types such as breast,(16) prostate,(9) and pancreat…”
BackgroundDyvorne, H. A., Galea, N., Nevers, T., Fiel, M. I., Carpenter, D., Wong, E., Orton, M., de Oliveira, A., Feiweier, T., Vachon, M.-L., et al. (2013) · Radiology · doi:10.1148/radiol.12120686 · Cited by 182
“This Health Insurance Portability and Accountability Act compliant single-center prospective study was funded by the Intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging models the diffusion-attenuated magnetic resonance (MR) imaging signal as a sum of static tissue molecular diffusion (D, true diffusio…”
MethodOdéen, H., & Parker, D. L. (2019) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2019.01.003 · Cited by 182
“The effects of perfusion can to some degree be compensated for by the choice of b-values [102].”
BackgroundMannelli, L., Kim, S., Hajdu, C. H., Babb, J. S., Clark, T. W. I., & Taouli, B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1461 · Cited by 182
“Through quantification of brownian motion of water molecules and microperfusion [28], DWI can be used to determine the degree of tumor viability by showing early posttreatment changes in ADC, as suggested by results with various tumor models in animals [26, 29–32], including HCC models [20].”
ResultVandecaveye, V., De Keyzer, F., Verslype, C., Op de Beeck, K., Komuta, M., Topal, B., Roebben, I., Bielen, D., Roskams, T., Nevens, F., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1431-5 · Cited by 181
“MRI) allows for tissue characterisation by probing tissue microstructural changes, quantified as the apparent diffusion coefficient (ADC) [ 6 , 7]. The addition of two equally large but opposite gradient pulses makes DW-MRI susceptible to differences in water mobility.”
BackgroundOptimised diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain
Xing, D., Papadakis, N. G., Huang, C. L.-H., Lee, V. M., Adrian Carpenter, T., & Hall, L. D. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00037-4 · Cited by 181
Zhang, J. L., Sigmund, E. E., Chandarana, H., Rusinek, H., Chen, Q., Vivier, P.-H., Taouli, B., & Lee, V. S. (2010) · Radiology · doi:10.1148/radiol.09090891 · Cited by 179
Neeman, M., Freyer, J. P., & Sillerud, L. O. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910210117 · Cited by 179
Sumi, M., Van Cauteren, M., Sumi, T., Obara, M., Ichikawa, Y., & Nakamura, T. (2012) · Radiology · doi:10.1148/radiol.12111248 · Cited by 177
“D* is considered proportional to the mean capillary segment length and average blood velocity (12).”
BackgroundMethodDiffusion‐weighted imaging outside the brain: Consensus statement from an ISMRM‐sponsored workshop
Taouli, B., Beer, A. J., Chenevert, T., Collins, D., Lehman, C., Matos, C., Padhani, A. R., Rosenkrantz, A. B., Shukla‐Dave, A., Sigmund, E., et al. (2016) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25196 · Cited by 175
Partridge, S. C., DeMartini, W. B., Kurland, B. F., Eby, P. R., White, S. W., & Lehman, C. D. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22078 · Cited by 173
“DWI measures the mobility of water molecules in vivo and reflects characteristics of the microscopic cellular environment, including cell density, cell organization, and membrane integrity (3).”
BackgroundDardzinski, B. J., Sotak, C. H., Fisher, M., Hasegawa, Y., Li, L., & Minematsu, K. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300307 · Cited by 170
Guiu, B., Petit, J.-M., Capitan, V., Aho, S., Masson, D., Lefevre, P.-H., Favelier, S., Loffroy, R., Vergès, B., Hillon, P., et al. (2012) · Radiology · doi:10.1148/radiol.12112478 · Cited by 169
Diffusion-weighted imaging in rectal cancer: current applications and future perspectives
Schurink, N. W., Lambregts, D. M. J., & Beets-Tan, R. G. H. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20180655 · Cited by 169
Diffusion-weighted MR Imaging for Characterizing Musculoskeletal Lesions
Subhawong, T. K., Jacobs, M. A., & Fayad, L. M. (2014) · RadioGraphics · doi:10.1148/rg.345140190 · Cited by 166
Gomolka, R. S., Hablitz, L. M., Mestre, H., Giannetto, M., Du, T., Hauglund, N. L., Xie, L., Peng, W., Martinez, P. M., Nedergaard, M., et al. (2023) · eLife · doi:10.7554/elife.82232 · Cited by 165
“91 First, we used a standard DWI model which, by assuming monoexponential signal decay using apparent diffusion coefficient 92 (ADC), provides very sensitive but non-specific scoring for cellularity, the integrity of the cell membranes, and difference in 93 intracellular and ISF volumes (36) or their composition and v…”
MethodKang, K. M., Lee, J. M., Yoon, J. H., Kiefer, B., Han, J. K., & Choi, B. I. (2014) · Radiology · doi:10.1148/radiol.13122712 · Cited by 162
“However, earlier studies have also demonstrated that the diffusion-weighted signal and ADC values can be influenced not only by molecular diffusion but also through microcirculation, or blood perfusion, and, therefore, ADC values containing perfusion effect may limit the reliability of ADC in characterizing pancreatic…”
BackgroundLi, Y. T., Cercueil, J.-P., Yuan, J., Chen, W., Loffroy, R., & Wáng, Y. X. J. (2017) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2017.02.03 · Cited by 162
“In the presence of a magnetic field gradient, diffusion of water molecules causes a phase dispersion of the transverse magnetization, which results in the attenuation of the MRI signal (1).”
BackgroundInfluentialNormal Brain and Brain Tumor: Multicomponent Apparent Diffusion Coefficient Line Scan Imaging
Maier, S. E., Bogner, P., Bajzik, G., Mamata, H., Mamata, Y., Repa, I., Jolesz, F. A., & Mulkern, R. V. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn02842 · Cited by 158
“microcirculation ( 20 ,21). Signal loss due to microcirculation is observed only with”
BackgroundDiffusion‐weighted imaging of inflammatory myopathies: Polymyositis and dermatomyositis
Qi, J., Olsen, N. J., Price, R. R., Winston, J. A., & Park, J. H. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21209 · Cited by 158
Human brain: Proton diffusion MR spectroscopy
Posse, S., Cuenod, C. A., & Le Bihan, D. (1993) · Radiology · doi:10.1148/radiology.188.3.8351339 · Cited by 122
The sensitivity of diffusion MRI to microstructural properties and experimental factors
Afzali, M., Pieciak, T., Newman, S., Garyfallidis, E., Özarslan, E., Cheng, H., & Jones, D. K. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108951 · Cited by 117
Demiral, Ş. B., Tomasi, D., Sarlls, J., Lee, H., Wiers, C. E., Zehra, A., Srivastava, T., Ke, K., Shokri-Kojori, E., Freeman, C. R., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.043 · Cited by 110
Cohen, A. D., Schieke, M. C., Hohenwalter, M. D., & Schmainda, K. M. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25109 · Cited by 105
Le Bihan, D., Ichikawa, S., & Motosugi, U. (2017) · Radiology · doi:10.1148/radiol.2017170025 · Cited by 102
Ramamonjisoa, N., & Ackerstaff, E. (2017) · Frontiers in Oncology · doi:10.3389/fonc.2017.00003 · Cited by 93
“org January 2017 | Volume 7 | Article 3 and deoxyhemoglobin paramagnetic contrast, respectively (223), and (v) diffusion-weighted MRI (DW-MRI), where intravoxel incoherent motion (IVIM) reflects vascular perfusion (64, 224, 229, 233, 234).”
BackgroundAn intrinsic diffusion response function for analyzing diffusion functional MRI time series
Aso, T., Urayama, S.-I., Poupon, C., Sawamoto, N., Fukuyama, H., & Bihan, D. L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.027 · Cited by 47
Self-citationKohno, S., Sawamoto, N., Urayama, S.-I., Aso, T., Aso, K., Seiyama, A., Fukuyama, H., & Le Bihan, D. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.45 · Cited by 30
“Second, flow of blood induces a further signal reduction in the presence of the magnetic-field gradient pulses via the so-called intravoxel incoherent motion effect (Le Bihan et al, 1988).”
On time and space in the brain: A relativistic pseudo-diffusion framework
Le Bihan, D. (2020) · Brain Multiphysics · doi:10.1016/j.brain.2020.100016 · Cited by 30
Functional diffusion tensor imaging at 3 Tesla
Mandl, R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00817 · Cited by 18
““fnhum-07-00817” — 2013/11/29 — 19:58 — page 1 — #1 ORIGINAL RESEARCH ARTICLE published: 03 December 2013 doi: 10.3389/fnhum.2013.00817 Functional diffusion tensor imaging at 3Tesla”
MethodInfluentialBrain imaging in stroke: insight beyond diagnosis.
Nour, M., & Liebeskind, D. S. (2011) · Neurotherapeutics · doi:10.1007/s13311-011-0046-0 · Cited by 15
Kershaw, J., Tomiyasu, M., Kashikura, K., Hirano, Y., Nonaka, H., Hirano, M., Ikehira, H., Kanno, I., & Obata, T. (2009) · NMR in Biomedicine · doi:10.1002/nbm.1391 · Cited by 14
“for this is that, with the application of diffusion-weighting (as characterised by the b-value (1)), themotion of blood through the irregularly arranged vessels of a single voxel is known to suppress intravascular (IV) signal more strongly than the extravascular (EV) contribution (2,3).”
BackgroundInfluentialEngineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Crombé, A., Nicolas, R., Richard, N., Tourdias, T., & Hiba, B. (2022) · Scientific Reports · doi:10.1038/s41598-022-15511-0 · Cited by 13
40 Years of diffusion MRI in the brain: From history to emerging frontiers
Le Bihan, D. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1365 · Cited by 2
“3) ( Iima & Le Bihan, 2016; Le Bihan, 2019; Le Bihan & Turner, 1992; Le Bihan et al., 1988).”
Influential
Metadata
- Authors
- Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M.
- Venue
- Radiology
- Published
- 1988-08
- Volume
- 168
- Issue
- 2
- Pages
- 497-505
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2139794744
- Cited by
- 3,169
- References
- 0
- FWCI
- 25.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.