Elastography of breast lesions: initial clinical results.
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine the appearance of various breast lesions on elastograms and to explore the potential of elastography in the diagnosis of breast lesions. MATERIALS AND METHODS: A total of 46 breast lesions were examined with elastography. Patients underwent biopsy or aspiration of all lesions, revealing 15 fibroadenomas, 12 carcinomas, six fibrocystic nodules, and 13 other lesions. The elastogram was generated from radio-frequency data collected with use of a 5-MHz linear-array transducer. The elastogram and corresponding sonogram were evaluated by a single observer for lesion visualization, relative brightness, and margin definition and regularity. The sizes of the lesions at each imaging examination and at biopsy were recorded and compared. RESULTS: Softer tissues such as fat appear as bright areas on elastograms. Firm tissues, including parenchyma, cancers, and other masses, appear darker. The cancers were statistically significantly darker than fibroadenomas (P < .005) and substantially larger on the elastogram than on the sonogram. Seventy-three percent of fibroadenomas and 56% of solid benign lesions could be distinguished from cancers by using lesion brightness and size difference. Some cancers that appeared as areas of shadowing on sonograms appeared as discrete masses on elastograms. CONCLUSION: Elastography has the potential to be useful in the evaluation of areas of shadowing on the sonogram. It also may be helpful in the distinction of benign from malignant masses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Self-citationBreast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Ultrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Shiina, T., Nightingale, K. R., Palmeri, M. L., Hall, T. J., Bamber, J. C., Barr, R. G., Castera, L., Choi, B. I., Chou, Y.-H., Cosgrove, D., et al. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.03.009 · Cited by 958
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Self-citationTanter, M., Bercoff, J., Athanasiou, A., Deffieux, T., Gennisson, J.-L., Montaldo, G., Muller, M., Tardivon, A., & Fink, M. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.02.002 · Cited by 733
On the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731
Samani, A., Zubovits, J., & Plewes, D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/6/002 · Cited by 707
Selected Methods for Imaging Elastic Properties of Biological Tissues
Greenleaf, J. F., Fatemi, M., & Insana, M. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121623 · Cited by 671
Elastography: New Developments in Ultrasound for Predicting Malignancy in Thyroid Nodules
Rago, T., Santini, F., Scutari, M., Pinchera, A., & Vitti, P. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2007-0641 · Cited by 592
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Breast Lesions: Quantitative Elastography with Supersonic Shear Imaging—Preliminary Results
Athanasiou, A., Tardivon, A., Tanter, M., Sigal-Zafrani, B., Bercoff, J., Deffieux, T., Gennisson, J.-L., Fink, M., & Neuenschwander, S. (2010) · Radiology · doi:10.1148/radiol.10090385 · Cited by 519
Ultrafast compound doppler imaging: providing full blood flow characterization
Bercoff, J., Montaldo, G., Loupas, T., Savery, D., Mézière, F., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1780 · Cited by 510
High-resolution tensor MR elastography for breast tumour detection
Sinkus, R., Lorenzen, J., Schrader, D., Lorenzen, M., Dargatz, M., & Holz, D. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/317 · Cited by 481
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography
Arda, K., Ciledag, N., Aktas, E., Arıbas, B. K., & Köse, K. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5449 · Cited by 467
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Quantifying elasticity and viscosity from measurement of shear wave speed dispersion
Chen, S., Fatemi, M., & Greenleaf, J. F. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1739480 · Cited by 416
Shear Wave Spectroscopy for In Vivo Quantification of Human Soft Tissues Visco-Elasticity
Deffieux, T., Montaldo, G., Tanter, M., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.925077 · Cited by 411
Catheline, S., Gennisson, J.-L., Delon, G., Fink, M., Sinkus, R., Abouelkaram, S., & Culioli, J. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1815075 · Cited by 409
Shear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
In vivo real-time freehand palpation imaging
Hall, T. J., Zhu, Y., & Spalding, C. S. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00733-0 · Cited by 394
MR Elastography of Breast Cancer: Preliminary Results
McKnight, A. L., Kugel, J. L., Rossman, P. J., Manduca, A., Hartmann, L. C., & Ehman, R. L. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.6.1781411 · Cited by 381
Imaging anisotropic and viscous properties of breast tissue by magnetic resonance‐elastography
Sinkus, R., Tanter, M., Catheline, S., Lorenzen, J., Kuhl, C., Sondermann, E., & Fink, M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20355 · Cited by 380
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Self-citationMechanisms and impact of altered tumour mechanics
Mohammadi, H., & Sahai, E. (2018) · Nature Cell Biology · doi:10.1038/s41556-018-0131-2 · Cited by 336
Non‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
MR Elastography of Liver Tumors: Preliminary Results
Venkatesh, S. K., Yin, M., Glockner, J. F., Takahashi, N., Araoz, P. A., Talwalkar, J. A., & Ehman, R. L. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3123 · Cited by 312
Huang, Y.-P., Zheng, Y.-P., Wang, S.-Z., Chen, Z.-P., Huang, Q.-H., & He, Y.-H. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/1/015805 · Cited by 312
Tissue elasticity properties as biomarkers for prostate cancer
Hoyt, K., Castaneda, B., Zhang, M., Nigwekar, P., di Sant'Agnese, P. A., Joseph, J. V., Strang, J., Rubens, D. J., & Parker, K. J. (2008) · Cancer Biomarkers · doi:10.3233/cbm-2008-44-505 · Cited by 303
Differentiating Benign from Malignant Solid Breast Masses with US Strain Imaging
Burnside, E. S., Hall, T. J., Sommer, A. M., Hesley, G. K., Sisney, G. A., Svensson, W. E., Fine, J. P., Jiang, J., & Hangiandreou, N. J. (2007) · Radiology · doi:10.1148/radiol.2452061805 · Cited by 296
Janssen, J., Schlörer, E., & Greiner, L. (2007) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2006.12.057 · Cited by 275
Myocardial elastography—a feasibility study in vivo
Konofagou, E. E., D’hooge, J., & Ophir, J. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00488-x · Cited by 264
Self-citationDiagnostic Performance of Gray-Scale US and Elastography in Solid Thyroid Nodules
Moon, H. J., Sung, J. M., Kim, E.-K., Yoon, J. H., Youk, J. H., & Kwak, J. Y. (2012) · Radiology · doi:10.1148/radiol.11110839 · Cited by 251
“Elastography has been introduced to evaluate the tissue hardness objectively and to augment the diagnostic accuracy of gray-scale ultrasonography (US) (5,6).”
BackgroundRehabilitative Ultrasound Imaging: Understanding the Technology and Its Applications
Whittaker, J. L., Teyhen, D. S., Elliott, J. M., Cook, K., Langevin, H. M., Dahl, H. H., & Stokes, M. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2350 · Cited by 250
High-Resolution Quantitative Imaging of Cornea Elasticity Using Supersonic Shear Imaging
Tanter, M., Touboul, D., Gennisson, J.-L., Bercoff, J., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021471 · Cited by 234
“trasound-based methods assessing viscoelastic properties of tissue are studied for many diagnostic applications such as breast cancer diagnosis [1], [2], liver fibrosis staging [3]–[5], arterial wall [6], [7], and cardiac muscle elasticity imaging [8], [9].”
Background2-D companding for noise reduction in strain imaging
Chaturvedi, P., Insana, M. F., & Hall, T. J. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.646923 · Cited by 231
“Previously, strain noise was maintained at acceptable levels by compressing the tissue only a small percentage of its total height (≤1%) [7], [16].”
BackgroundThomas, A., Fischer, T., Frey, H., Ohlinger, R., Grunwald, S., Blohmer, J. ‐., Winzer, K. ‐., Weber, S., Kristiansen, G., Ebert, B., et al. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2823 · Cited by 229
Motion Estimation in Ultrasound Images Using Time Domain Cross Correlation With Prior Estimates
Zahiri-Azar, R., & Salcudean, S. E. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.881780 · Cited by 214
“It has been shown to be useful in different clinical applications such as tumor detection in the breast [5]–[7] and prostate [8], monitoring of high intensity focused ultrasound lesions [9], imaging the myocardium [10], studying deep venous thrombosis [11]–[13], studying renal pathology [14], monitoring thermal change…”
BackgroundReal-Time Sonoelastography Findings in Healthy Achilles Tendons
De Zordo, T., Fink, C., Feuchtner, G. M., Smekal, V., Reindl, M., & Klauser, A. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1843 · Cited by 195
“Although real-time sonoelastography is not yet used in routine clinical practice, it has been shown to be useful in the differential diagnosis of breast [6, 7], thyroid [8], and prostate [4] cancers and recently was applied to lymph node characterization [9].”
MethodEUS elastography for the characterization of solid pancreatic masses
Iglesias-Garcia, J., Larino-Noia, J., Abdulkader, I., Forteza, J., & Dominguez-Munoz, J. E. (2009) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2009.05.011 · Cited by 194
Elastographic characterization of HIFU-induced lesions in canine livers
Righetti, R., Kallel, F., Stafford, R. J., Price, R. E., Krouskop, T. A., Hazle, J. D., & Ophir, J. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00044-7 · Cited by 193
“This has been successfully demonstrated in vivo (Garra et al. 1997).”
BackgroundSelf-citationLocalized harmonic motion imaging: theory, simulations and experiments
Konofagou, E. E., & Hynynen, K. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)00953-0 · Cited by 184
“…rights reserved 0301-5629/03/$–see front matter good quality strain images (or, elastograms) in several tissues, such as in vivo breast cancer (Céspedes et al. 1993; Garra et al. 1997; Ophir et al. 2001), in vitro normal prostate (Konofagou and Ophir 1998) and in vitro kidney (Ophir et al. 2001).”
BackgroundBreast Lesions: Evaluation with US Strain Imaging–Clinical Experience of Multiple Observers
Regner, D. M., Hesley, G. K., Hangiandreou, N. J., Morton, M. J., Nordland, M. R., Meixner, D. D., Hall, T. J., Farrell, M. A., Mandrekar, J. N., Harmsen, W. S., et al. (2006) · Radiology · doi:10.1148/radiol.2381041336 · Cited by 175
“Researchers have found that malignant lesions tend to be larger on strain images than on corresponding B-mode images, potentially because of the surrounding desmoplastic reaction that accompanies most malignancies (6,11,17,19).”
BackgroundMethodResultInfluentialZhou, J., Zhan, W., Chang, C., Zhang, X., Jia, Y., Dong, Y., Zhou, C., Sun, J., & Grant, E. G. (2014) · Radiology · doi:10.1148/radiol.14130818 · Cited by 173
Quasi-Static Ultrasound Elastography
Varghese, T. (2009) · Ultrasound Clinics · doi:10.1016/j.cult.2009.10.009 · Cited by 169
“A second parameter referred to as the ‘size ratio’ derived from the ratio of the lesion dimensions derived from the strain and B-mode images was then proposed to differentiate between benign fibroadenomas from malignant tumors[13,15].”
BackgroundMethodResultInfluentialOphir, J., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., Righetti, R., & Varghese, T. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00156-3 · Cited by 166
Self-citationNoninvasive Vascular Elastography: Theoretical Framework
Maurice, R. L., Ohayon, J., Fretigny, Y., Bertrand, M., Soulez, G., & Cloutier, G. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823066 · Cited by 158
“Primary objectives of elastography were to complement B-mode ultrasound as a screening method to detect hard areas in the breast [2], [3], and to investigate prostate cancers [4], [5].”
BackgroundBrain mechanical property measurement using MRE with intrinsic activation
Weaver, J. B., Pattison, A. J., McGarry, M. D., Perreard, I. M., Swienckowski, J. G., Eskey, C. J., Lollis, S. S., & Paulsen, K. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/22/7275 · Cited by 102
“One of the first clinical applications of elastography involved detecting breast lesions (Sinkus et al 2000, Garra et al 1997, McKnight et al 2002).”
Background
Metadata
- Authors
- Garra, B. S., Cespedes, E. I., Ophir, J., Spratt, S. R., Zuurbier, R. A., Magnant, C. M., & Pennanen, M. F.
- Venue
- Radiology
- Published
- 1997-01
- Volume
- 202
- Issue
- 1
- Pages
- 79-86
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2157238234
- Cited by
- 940
- References
- 0
- FWCI
- 14.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.