Multisection cerebral blood flow MR imaging with continuous arterial spin labeling.
The DOI matches its Crossref record.
Abstract
A method was evaluated to control for off-resonance saturation in noninvasive magnetic resonance imaging with continuous arterial spin labeling of cerebral blood flow. In phantoms and humans, application of amplitude-modulated radio-frequency irradiation during the control image corrected for saturation across the whole brain and made possible cerebral blood flow imaging in multiple sections at arbitrary angles to the labeling plane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alsop, D. C., Detre, J. A., Golay, X., Günther, M., Hendrikse, J., Hernandez‐Garcia, L., Lu, H., MacIntosh, B. J., Parkes, L. M., Smits, M., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25197 · Cited by 2,206
Self-citationDai, W., Garcia, D., de Bazelaire, C., & Alsop, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21790 · Cited by 985
Self-citationMeasuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Glial Neoplasms: Dynamic Contrast-enhanced T2*-weighted MR Imaging
Knopp, E. A., Cha, S., Johnson, G., Mazumdar, A., Golfinos, J. G., Zagzag, D., Miller, D. C., Kelly, P. J., & Kricheff, I. I. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn46791 · Cited by 596
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Chalela, J. A., Alsop, D. C., Gonzalez-Atavales, J. B., Maldjian, J. A., Kasner, S. E., & Detre, J. A. (2000) · Stroke · doi:10.1161/01.str.31.3.680 · Cited by 481
Self-citationEmpirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx
Wang, Z., Aguirre, G. K., Rao, H., Wang, J., Fernández-Seara, M. A., Childress, A. R., & Detre, J. A. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.07.003 · Cited by 477
Self-citationParkes, L. M., Rashid, W., Chard, D. T., & Tofts, P. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20023 · Cited by 449
Assessment of cerebral blood flow in Alzheimer's disease by spin-labeled magnetic resonance imaging
Alsop, D. C., Detre, J. A., & Grossman, M. (2000) · Annals of Neurology · doi:10.1002/1531-8249(200001)47:1<93::aid-ana15>3.0.co;2-8 · Cited by 409
Self-citationMethodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403
“Conversion to CBF values was effected using a modification of a previously described approach (Alsop and Detre, 1996) which assumes a labeling efficiency of 71% (Alsop and Detre, 1998).”
MethodInfluentialSelf-citationDai, W., Lopez, O. L., Carmichael, O. T., Becker, J. T., Kuller, L. H., & Gach, H. M. (2009) · Radiology · doi:10.1148/radiol.2503080751 · Cited by 398
Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 Tesla
Wang, J., Alsop, D. C., Li, L., Listerud, J., Gonzalez‐At, J. B., Schnall, M. D., & Detre, J. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10211 · Cited by 369
Self-citationEffects of transcranial direct current stimulation (tDCS) on human regional cerebral blood flow
Zheng, X., Alsop, D. C., & Schlaug, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.018 · Cited by 368
Self-citationTranscranial Direct Current Stimulation in Stroke Recovery
Schlaug, G., Renga, V., & Nair, D. (2008) · Archives of Neurology · doi:10.1001/archneur.65.12.1571 · Cited by 365
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Latchaw, R. E., Yonas, H., Hunter, G. J., Yuh, W. T. C., Ueda, T., Sorensen, A. G., Sunshine, J. L., Biller, J., Wechsler, L., Higashida, R., et al. (2003) · Stroke · doi:10.1161/01.str.0000064840.99271.9e · Cited by 319
Detre, J. A., & Alsop, D. C. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00050-9 · Cited by 299
Self-citationArterial Spin-Labeling in Routine Clinical Practice, Part 1: Technique and Artifacts
Deibler, A. R., Pollock, J. M., Kraft, R. A., Tan, H., Burdette, J. H., & Maldjian, J. A. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1030 · Cited by 298
Xu, G., Rowley, H. A., Wu, G., Alsop, D. C., Shankaranarayanan, A., Dowling, M., Christian, B. T., Oakes, T. R., & Johnson, S. C. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1462 · Cited by 280
Self-citationArterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10559 · Cited by 275
Self-citationAn overview of CEST MRI for non-MR physicists
Wu, B., Warnock, G., Zaiss, M., Lin, C., Chen, M., Zhou, Z., Mu, L., Nanz, D., Tuura, R., & Delso, G. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0155-2 · Cited by 274
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Self-citationFloyd, T. F., Clark, J. M., Gelfand, R., Detre, J. A., Ratcliffe, S., Guvakov, D., Lambertsen, C. J., & Eckenhoff, R. G. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00303.2003 · Cited by 258
Self-citationPerfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Global and Regional Effects of Type 2 Diabetes on Brain Tissue Volumes and Cerebral Vasoreactivity
Last, D., Alsop, D. C., Abduljalil, A. M., Marquis, R. P., de Bazelaire, C., Hu, K., Cavallerano, J., & Novak, V. (2007) · Diabetes Care · doi:10.2337/dc06-2052 · Cited by 243
Self-citationBiagi, L., Abbruzzese, A., Bianchi, M. C., Alsop, D. C., Del Guerra, A., & Tosetti, M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20839 · Cited by 241
Self-citationTest–retest reliability of arterial spin labeling with common labeling strategies
Chen, Y., Wang, D. J. J., & Detre, J. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22345 · Cited by 238
“In practice, it has been difficult to achieve the full sensitivity of CASL for multislice imaging implementations due to inefficiencies in control labeling schemes (3).”
BackgroundSelf-citationArterial spin labeling in neuroimaging
Petcharunpaisan, S. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.384 · Cited by 225
Yu, G., Floyd, T. F., Durduran, T., Zhou, C., Wang, J., Detre, J. A., & Yodh, A. G. (2007) · Optics Express · doi:10.1364/oe.15.001064 · Cited by 223
Self-citationNoninvasive MRI evaluation of cerebral blood flow in cerebrovascular disease
Detre, J. A., Alsop, D. C., Vives, L. R., Maccotta, L., Teener, J. W., & Raps, E. C. (1998) · Neurology · doi:10.1212/wnl.50.3.633 · Cited by 209
Self-citationParkes, L. M., & Tofts, P. S. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10180 · Cited by 202
Hippocampal hyperperfusion in Alzheimer's disease
Alsop, D. C., Casement, M., de Bazelaire, C., Fong, T., & Press, D. Z. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.06.006 · Cited by 202
“Continuous ASL (Williams et al., 1992) was performed using flow driven adiabatic inversion and an improved version of a previously published method for subtracting off-resonance saturation effects (Alsop and Detre, 1998).”
MethodSelf-citationArterial spin labeling MRI study of age and gender effects on brain perfusion hemodynamics
Liu, Y., Zhu, X., Feinberg, D., Guenther, M., Gregori, J., Weiner, M. W., & Schuff, N. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23286 · Cited by 191
Comparative overview of brain perfusion imaging techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J. F., et al. (2005) · Journal of Neuroradiology · doi:10.1016/s0150-9861(05)83159-1 · Cited by 185
Distinct cerebral perfusion patterns in FTLD and AD
Hu, W. T., Wang, Z., Lee, V. M.-Y., Trojanowski, J. Q., Detre, J. A., & Grossman, M. (2010) · Neurology · doi:10.1212/wnl.0b013e3181f11e35 · Cited by 183
Self-citationSpectral characteristics of resting state networks
Niazy, R. K., Xie, J., Miller, K., Beckmann, C. F., & Smith, S. M. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53839-0.00017-x · Cited by 175
Asllani, I., Habeck, C., Scarmeas, N., Borogovac, A., Brown, T. R., & Stern, Y. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600570 · Cited by 172
“Arterial spin labeling techniques have been used in a variety of applications in both disease and normal brain function (Alsop and Detre, 1998; Golay et al, 2004).”
Wingrove, J., Swedrowska, M., Scherließ, R., Parry, M., Ramjeeawon, M., Taylor, D., Gauthier, G., Brown, L., Amiel, S., Zelaya, F., et al. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.032 · Cited by 67
Metadata
- Authors
- Alsop, D. C., & Detre, J. A.
- Venue
- Radiology
- Published
- 1998-08
- Volume
- 208
- Issue
- 2
- Pages
- 410-416
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2126976785
- Cited by
- 404
- References
- 0
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.