The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Material Separation Using Dual-Energy CT: Current and Emerging Applications
Abstract
Dual-energy (DE) computed tomography (CT) offers the opportunity to generate material-specific images on the basis of the atomic number Z and the unique mass attenuation coefficient of a particular material at different x-ray energies. Material-specific images provide qualitative and quantitative information about tissue composition and contrast media distribution. The most significant contribution of DE CT-based material characterization comes from the capability to assess iodine distribution through the creation of an image that exclusively shows iodine. These iodine-specific images increase tissue contrast and amplify subtle differences in attenuation between normal and abnormal tissues, improving lesion detection and characterization in the abdomen. In addition, DE CT enables computational removal of iodine influence from a CT image, generating virtual noncontrast images. Several additional materials, including calcium, fat, and uric acid, can be separated, permitting imaging assessment of metabolic imbalances, elemental deficiencies, and abnormal deposition of materials within tissues. The ability to obtain material-specific images from a single, contrast-enhanced CT acquisition can complement the anatomic knowledge with functional information, and may be used to reduce the radiation dose by decreasing the number of phases in a multiphasic CT examination. DE CT also enables generation of energy-specific and virtual monochromatic images. Clinical applications of DE CT leverage both material-specific images and virtual monochromatic images to expand the current role of CT and overcome several limitations of single-energy CT. (©)RSNA, 2016.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Kanis, J. A., & Kanis, J. A. (1994) · Osteoporosis International · doi:10.1007/bf01622200 · Cited by 2,516
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
Bae, K. T. (2010) · Radiology · doi:10.1148/radiol.10090908 · Cited by 1,067
Pickhardt, P. J., Pooler, B. D., Lauder, T., del Rio, A. M., Bruce, R. J., & Binkley, N. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-8-201304160-00003 · Cited by 954
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537
Dual energy CT: preliminary observations and potential clinical applications in the abdomen
Graser, A., Johnson, T. R. C., Chandarana, H., & Macari, M. (2009) · European Radiology · doi:10.1007/s00330-008-1122-7 · Cited by 479
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Neurogenic Tumors in the Abdomen: Tumor Types and Imaging Characteristics
Rha, S. E., Byun, J. Y., Jung, S. E., Chun, H. J., Lee, H. G., & Lee, J. M. (2003) · RadioGraphics · doi:10.1148/rg.231025050 · Cited by 443
Quantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
Coursey, C. A., Nelson, R. C., Boll, D. T., Paulson, E. K., Ho, L. M., Neville, A. M., Marin, D., Gupta, R. T., & Schindera, S. T. (2010) · RadioGraphics · doi:10.1148/rg.304095175 · Cited by 375
Self-citationState of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Dual energy computed tomography in tophaceous gout
Choi, H. K., Al-Arfaj, A. M., Eftekhari, A., Munk, P. L., Shojania, K., Reid, G., & Nicolaou, S. (2009) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2008.099713 · Cited by 330
Nanocrystal Core High-Density Lipoproteins: A Multimodality Contrast Agent Platform
Cormode, D. P., Skajaa, T., van Schooneveld, M. M., Koole, R., Jarzyna, P., Lobatto, M. E., Calcagno, C., Barazza, A., Gordon, R. E., Zanzonico, P., et al. (2008) · Nano Letters · doi:10.1021/nl801958b · Cited by 328
Primak, A. N., Ramirez Giraldo, J. C., Liu, X., Yu, L., & McCollough, C. H. (2009) · Medical Physics · doi:10.1118/1.3083567 · Cited by 318
Measurement of effective atomic number and electron density using an EMI scanner
Rutherford, R. A., Pullan, B. R., & Isherwood, I. (1976) · Neuroradiology · doi:10.1007/bf00327253 · Cited by 300
Pache, G., Krauss, B., Strohm, P., Saueressig, U., Blanke, P., Bulla, S., Schäfer, O., Helwig, P., Kotter, E., Langer, M., et al. (2010) · Radiology · doi:10.1148/radiol.10091230 · Cited by 281
Gupta, R., Phan, C. M., Leidecker, C., Brady, T. J., Hirsch, J. A., Nogueira, R. G., & Yoo, A. J. (2010) · Radiology · doi:10.1148/radiol.10091806 · Cited by 250
Self-citationOncologic Applications of Dual-Energy CT in the Abdomen
Agrawal, M. D., Pinho, D. F., Kulkarni, N. M., Hahn, P. F., Guimaraes, A. R., & Sahani, D. V. (2014) · RadioGraphics · doi:10.1148/rg.343135041 · Cited by 234
Self-citationLung Perfusion with Dual-energy Multidetector-row CT (MDCT)
Pontana, F., Faivre, J.-B., Remy-Jardin, M., Flohr, T., Schmidt, B., Tacelli, N., Pansini, V., & Remy, J. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.05.018 · Cited by 233
A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images
Mendonca, P. R. S., Lamb, P., & Sahani, D. V. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2281719 · Cited by 220
Self-citationLv, P., Lin, X. Z., Li, J., Li, W., & Chen, K. (2011) · Radiology · doi:10.1148/radiol.11101425 · Cited by 205
Samir, A. E., Dhyani, M., Vij, A., Bhan, A. K., Halpern, E. F., Méndez-Navarro, J., Corey, K. E., & Chung, R. T. (2015) · Radiology · doi:10.1148/radiol.14140839 · Cited by 205
Dual energy CT in gout: a prospective validation study
Choi, H. K., Burns, L. C., Shojania, K., Koenig, N., Reid, G., Abufayyah, M., Law, G., Kydd, A. S., Ouellette, H., & Nicolaou, S. (2012) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2011-200976 · Cited by 197
Computed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Sheedy, S. P., Earnest, F., Fletcher, J. G., Fidler, J. L., & Hoskin, T. L. (2006) · Radiology · doi:10.1148/radiol.2413050965 · Cited by 193
Bone Marrow Edema in Vertebral Compression Fractures: Detection with Dual-Energy CT
Wang, C.-K., Tsai, J.-M., Chuang, M.-T., Wang, M.-T., Huang, K.-Y., & Lin, R.-M. (2013) · Radiology · doi:10.1148/radiol.13122577 · Cited by 177
Mileto, A., Marin, D., Alfaro-Cordoba, M., Ramirez-Giraldo, J. C., Eusemann, C. D., Scribano, E., Blandino, A., Mazziotti, S., & Ascenti, G. (2014) · Radiology · doi:10.1148/radiol.14140171 · Cited by 174
Imaging modalities for the classification of gout: systematic literature review and meta-analysis
Ogdie, A., Taylor, W. J., Weatherall, M., Fransen, J., Jansen, T. L., Neogi, T., Schumacher, H. R., & Dalbeth, N. (2015) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2014-205431 · Cited by 169
Tissue Signatures with Dual-Energy Computed Tomography
Di Chiro, G., Brooks, R. A., Kessler, R. M., Johnston, G. S., Jones, A. E., Herdt, J. R., & Sheridan, W. T. (1979) · Radiology · doi:10.1148/131.2.521 · Cited by 168
Gout: a clinical and radiologic review
Monu, J. U. V., & POPE, T. L. (2004) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(03)00158-1 · Cited by 153
Selective iodine imaging using K‐edge energies in computerized x‐ray tomography
Riederer, S. J., & Mistretta, C. A. (1977) · Medical Physics · doi:10.1118/1.594357 · Cited by 153
Extraction of information from CT scans at different energies
Millner, M. R., McDavid, W. D., Waggener, R. G., Dennis, M. J., Payne, W. H., & Sank, V. J. (1979) · Medical Physics · doi:10.1118/1.594555 · Cited by 144
Ronot, M., Asselah, T., Paradis, V., Michoux, N., Dorvillius, M., Baron, G., Marcellin, P., BEERS, B. E. V., & Vilgrain, V. (2010) · Radiology · doi:10.1148/radiol.10091295 · Cited by 128
Contrast-Enhanced Dual-Energy CT of Gastrointestinal Stromal Tumors
Apfaltrer, P., Meyer, M., Meier, C., Henzler, T., Barraza, J. M., Dinter, D. J., Hohenberger, P., Schoepf, U. J., Schoenberg, S. O., & Fink, C. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e31823003d2 · Cited by 121
Ho, L. M., Marin, D., Neville, A. M., Barnhart, H. X., Gupta, R. T., Paulson, E. K., & Boll, D. T. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7316 · Cited by 112
Self-citationPotretzke, T. A., Brace, C. L., Lubner, M. G., Sampson, L. A., Willey, B. J., & Lee, F. T. (2014) · Radiology · doi:10.1148/radiol.14140875 · Cited by 104
Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses
Ascenti, G., Mazziotti, S., Mileto, A., Racchiusa, S., Donato, R., Settineri, N., & Gaeta, M. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7711 · Cited by 100
Pandharipande, P. V., Gervais, D. A., Hartman, R. I., Harisinghani, M. G., Feldman, A. S., Müeller, P. R., & Gazelle, G. S. (2010) · Radiology · doi:10.1148/radiol.10092013 · Cited by 95
Mileto, A., Nelson, R. C., Marin, D., Choudhury, K. R., & Ho, L. M. (2014) · Radiology · doi:10.1148/radiol.14140876 · Cited by 92
Adenoma Characterization: Adrenal Protocol with Dual-Energy CT
Kim, Y. K., Park, B. K., Kim, C. K., & Park, S. Y. (2013) · Radiology · doi:10.1148/radiol.12112735 · Cited by 90
McNamara, M. M., Little, M. D., Alexander, L. F., Carroll, L. V., Beasley, T. M., & Morgan, D. E. (2014) · Abdominal Imaging · doi:10.1007/s00261-014-0274-y · Cited by 89
Kim, S. J., Lim, H. K., Lee, H. Y., Choi, C. G., Lee, D. H., Suh, D. C., Kim, S. M., Kim, J. K., & Krauß, B. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2890 · Cited by 87
Quantification of Hepatic Steatosis With Dual-Energy Computed Tomography
Artz, N. S., Hines, C. D. G., Brunner, S. T., Agni, R. M., Kühn, J., Roldán‐Alzate, A., Chen, G., & Reeder, S. B. (2012) · Investigative Radiology · doi:10.1097/rli.0b013e318261fad0 · Cited by 86
Dual-Energy CT for Characterization of the Incidental Adrenal Mass: Preliminary Observations
Gnannt, R., Fischer, M. A., Goetti, R. P., Karlo, C. A., Leschka, S., & Alkadhi, H. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6957 · Cited by 79
Pancreatic dual-source dual-energy CT: Is it time to discard unenhanced imaging?
Mileto, A., Mazziotti, S., Gaeta, M., Bottari, A., Zimbaro, F., Giardina, C., & Ascenti, G. (2011) · Clinical Radiology · doi:10.1016/j.crad.2011.09.004 · Cited by 74
Bredella, M. A., Daley, S. M., Kalra, M. K., Brown, J. K., Miller, K. K., & Torriani, M. (2015) · Radiology · doi:10.1148/radiol.2015142876 · Cited by 71
Stratification of Patients With Liver Fibrosis Using Dual-Energy CT
Lamb, P., Sahani, D. V., Fuentes, J. M., Patiño, M., Ghosh, A., & Mendonça, P. R. S. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2353044 · Cited by 70
Self-citationStarup‐Linde, J., Waldhauer, E., Rolighed, L., Mosekilde, L., & Vestergaard, P. (2012) · European Journal of Endocrinology · doi:10.1530/eje-12-0032 · Cited by 69
Stiller, W., Skornitzke, S., Fritz, F. L., Klauß, M., Hansen, J., Pahn, G., Grenacher, L., & Kauczor, H. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000176 · Cited by 59
Relative properties of tomography, K‐edge imaging, and K‐edge tomography
Kruger, R. A., Riederer, S. J., & Mistretta, C. A. (1977) · Medical Physics · doi:10.1118/1.594374 · Cited by 57
Suh, M. J., Coakley, F. V., Qayyum, A., Yeh, B. M., Breiman, R. S., & Lü, Y. (2003) · Radiology · doi:10.1148/radiol.2282020922 · Cited by 49
Korn, A., Bender, B., Thomas, C. K., Danz, S., Fenchel, M. C., Nägele, T., Heuschmid, M., Ernemann, U., & Hauser, T. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.08.028 · Cited by 42
Morgan, D. E., Weber, A. C., Lockhart, M. E., et al. (2013) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0b013e3182aaf996 · Cited by 41
Patel, B. N., Kumbla, R. A., Berland, L. L., Fineberg, N. S., & Morgan, D. E. (2013) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000000027 · Cited by 34
Zweig, B. M., Sheth, M., Simpson, S., & Al-Mallah, M. H. (2011) · International journal of cardiac imaging · doi:10.1007/s10554-011-9818-1 · Cited by 28
Cited by
Roski, F., Hammel, J., Mei, K., Baum, T., Kirschke, J. S., Laugerette, A., Kopp, F. K., Bodden, J., Pfeiffer, D., Pfeiffer, F., et al. (2019) · European Radiology · doi:10.1007/s00330-019-06263-z · Cited by 70
Jang, W., & Song, J. S. (2023) · Diagnostics · doi:10.3390/diagnostics13111852 · Cited by 55
Metadata
- Authors
- Patino, M., Prochowski, A., Agrawal, M. D., Simeone, F. J., Gupta, R., Hahn, P. F., & Sahani, D. V.
- Venue
- RadioGraphics
- Published
- 2016-07
- Volume
- 36
- Issue
- 4
- Pages
- 1087-1105
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2469072646
- Cited by
- 328
- References
- 59
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.