The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Abstract
Fatty liver disease is the most common cause of chronic liver disease in the United States. Noninvasive detection and quantification of fat is becoming more and more important clinically, due in large part to the growing prevalence of nonalcoholic fatty liver disease. Steatosis, the accumulation of fat-containing vacuoles within hepatocytes, is a key histologic feature of fatty liver disease. Liver biopsy, the current standard of reference for the assessment of steatosis, is invasive, has sampling errors, and is not appropriate in some settings. Several magnetic resonance (MR) imaging-based techniques--including chemical shift imaging, frequency-selective imaging, and MR spectroscopy--are currently in clinical use for the detection and quantification of fat-water admixtures, with each technique having important advantages, disadvantages, and limitations. These techniques permit the breakdown of the net MR signal into fat and water signal components, allowing the quantification of fat in liver tissue, and are increasingly being used in the diagnosis, treatment, and follow-up of fatty liver disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A placebo-controlled trial of pioglitazone in subjects with nonalcoholic steatohepatitis
Belfort, R., Harrison, S. A., Brown, K., Darland, C., Finch, J., Hardies, J., Balas, B., Gastaldelli, A., Tio, F., Pulcini, J., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060326 · Cited by 1,827
Handbook of MRI Pulse Sequences
(2004) · Elsevier eBooks · doi:10.1016/b978-0-12-092861-3.x5000-6 · Cited by 1,610
Szczepaniak, L. S., Nurenberg, P., Leonard, D., Browning, J. D., Reingold, J. S., Grundy, S., Hobbs, H. H., & Dobbins, R. L. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00064.2004 · Cited by 1,562
Bottomley, P. A., Foster, T. H., Argersinger, R. E., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595535 · Cited by 1,192
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Self-citationProton MR spectroscopy in quantitative in vivo determination of fat content in human liver steatosis
Longo, R., Pollesello, P., Ricci, C., Masutti, F., Kvam, B. J., Bercich, L., Croce, L. S., Grigolato, P., Paoletti, S., De Bernard, B., et al. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050311 · Cited by 387
Water–fat separation with IDEAL gradient‐echo imaging
Reeder, S. B., McKenzie, C. A., Pineda, A. R., Yu, H., Shimakawa, A., Brau, A. C., Hargreaves, B. A., Gold, G. E., & Brittain, J. H. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20831 · Cited by 357
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S. (2005) · Radiology · doi:10.1148/radiol.2373041639 · Cited by 277
LONGO, R., RICC, C., MASUTTI, F., VIDIMARI, R., CROC??, L. S., BERCICH, L., TIRIBELLI, C., & PALMA, L. D. (1993) · Investigative Radiology · doi:10.1097/00004424-199304000-00006 · Cited by 273
Field map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition
Yu, H., Reeder, S. B., Shimakawa, A., Brittain, J. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20654 · Cited by 217
Kim, H., Taksali, S. E., Dufour, S., Befroy, D., Goodman, T. R., Petersen, K. F., Shulman, G. I., Caprio, S., & Constable, R. T. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21561 · Cited by 206
Qayyum, A., Goh, J. S., Kakar, S., Yeh, B. M., Merriman, R. B., & Coakley, F. V. (2005) · Radiology · doi:10.1148/radiol.2372040539 · Cited by 185
Fatty infiltration of the liver: quantification with phase-contrast MR imaging at 1.5 T vs biopsy.
Levenson, H., Greensite, F., Hoefs, J., Friloux, L., Applegate, G., Silva, E., Kanel, G., & Buxton, R. (1991) · American Journal of Roentgenology · doi:10.2214/ajr.156.2.1898804 · Cited by 171
Liver Fat: Effect of Hepatic Iron Deposition on Evaluation with Opposed-Phase MR Imaging
Westphalen, A. C. A., Qayyum, A., Yeh, B. M., Merriman, R. B., Lee, J. A., Lamba, A., Lu, Y., & Coakley, F. V. (2007) · Radiology · doi:10.1148/radiol.2422052024 · Cited by 165
Machann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162
MITCHELL, D. G., KIM, I., CHANG, T. S., VINITSKI, S., SAPONARO, S. A., EHRLICH, S. M., RIFKIN, M. D., & RUBIN, R. (1991) · Investigative Radiology · doi:10.1097/00004424-199112000-00002 · Cited by 131
Comparison of fat quantification methods: A phantom study at 3.0T
Bernard, C. P., Liney, G. P., Manton, D. J., Turnbull, L. W., & Langton, C. M. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21201 · Cited by 129
Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction
Coombs, B. D., Szumowski, J., & Coshow, W. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380606 · Cited by 127
Rinella, M. E., McCarthy, R., Thakrar, K. H., Finn, J. P., Rao, S. M., Koffron, A. J., Abecassis, M. M., & Blei, A. T. (2003) · Liver Transplantation · doi:10.1053/jlts.2003.50153 · Cited by 101
Hollak, C. E. M., Maas, M. M., Akkerman, E. M., den Heeten, A., & Aerts, J. M. F. G. (2001) · Blood Cells Molecules and Diseases · doi:10.1006/bcmd.2001.0474 · Cited by 84
Multi-exponential relaxation analysis with MR imaging and NMR spectroscopy using fat-water systems
Kamman, R. L., Bakker, C. J. G., van Dijk, P., Stomp, G. P., Heiner, A. P., & Berendsen, H. J. C. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90127-5 · Cited by 46
Chang, J. S., Taouli, B. A., Salibi, N., Hecht, E. M., Chin, D. G., & Lee, V. S. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0695 · Cited by 41
Measurement of liver fat content using selective saturation at 3.0 T
Cotler, S. J., Guzman, G., Layden‐Almer, J. E., et al. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20865 · Cited by 33
Cited by
Radiologic evaluation of nonalcoholic fatty liver disease
Lee, S. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i23.7392 · Cited by 426
Lee, S. S., Park, S. H., Kim, H. J., Kim, S. Y., Kim, M.-Y., Kim, D. Y., Suh, D. J., Kim, K. M., Bae, M. H., Lee, J. Y., et al. (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2010.01.008 · Cited by 372
Dulai, P. S., Sirlin, C. B., & Loomba, R. (2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.06.005 · Cited by 356
Self-citationBacchi, E., Negri, C., Targher, G., Faccioli, N., Lanza, M., Zoppini, G., Zanolin, E., Schena, F., Bonora, E., & Moghetti, P. (2013) · Hepatology · doi:10.1002/hep.26393 · Cited by 350
van Werven, J. R., Marsman, H. A., Nederveen, A. J., Smits, N. J., ten Kate, F. J., van Gulik, T. M., & Stoker, J. (2010) · Radiology · doi:10.1148/radiol.10091790 · Cited by 329
Metadata
- Authors
- Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B.
- Venue
- RadioGraphics
- Published
- 2009-01
- Volume
- 29
- Issue
- 1
- Pages
- 231-260
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2148948654
- Cited by
- 271
- References
- 29
- FWCI
- 14.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.