Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background— Multislice spiral computed tomography (MSCT) is a promising technique for noninvasive coronary angiography, although clinical application has remained limited because of frequently incomplete interpretability, caused by motion artifacts and calcifications. Methods and Results— In 59 patients (53 male, aged 58±12 years) with suspected obstructive coronary artery disease, ECG-gated MSCT angiography was performed with a 16-slice MSCT scanner (0.42-s rotation time, 12×0.75-mm detector collimation). Thirty-four patients were given additional β-blockers (average heart rate: 56±6 min −1 ). After contrast injection, all data were acquired during an approximately 20-s breath hold. The left main (LM), left anterior descending (LAD), left circumflex (LCX), and right coronary artery (RCA), including ≥2.0-mm side branches, were independently evaluated by two blinded observers and screened for ≥50% stenoses. The consensus reading was compared with quantitative coronary angiography. MSCT was successful in 58 patients. Eighty-six of the 231 evaluated branches were significantly diseased. Without exclusion of branches, the sensitivity, specificity and positive and negative predictive value to identify ≥50% obstructed branches was 95% (82/86), 86% (125/145), 80% (82/102), and 97% (125/129), respectively. The overall accuracy for the LM, LAD, RCA, and LCX was 100%, 91%, 86%, and 81%, respectively. No obstructed LM, LAD, or RCA branches remained undetected. Classification of patients as having no, single, or multivessel disease was accurate in 78% (45/58) of patients and no patients with significant obstructions were incorrectly excluded. Conclusions— Improvements in MSCT technology, combined with heart rate control, allow reliable noninvasive detection of obstructive coronary artery disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Kim, W. Y., Danias, P. G., Stuber, M., Flamm, S. D., Plein, S., Nagel, E., Langerak, S. E., Weber, O. M., Pedersen, E. M., Schmidt, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010866 · Cited by 903
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Achenbach, S., Moshage, W., Ropers, D., Nossen, J., & Daniel, W. G. (1998) · New England Journal of Medicine · doi:10.1056/nejm199812313392702 · Cited by 382
Cited by
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Self-citationAccuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Clinical biomarkers in drug discovery and development
Frank, R., & Hargreaves, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1130 · Cited by 794
Atherothrombosis and High-Risk Plaque
Fuster, V., Moreno, P. R., Fayad, Z. A., Corti, R., & Badimon, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.074 · Cited by 738
Leber, A. W., Knez, A., Becker, A., Becker, C., von Ziegler, F., Nikolaou, K., Rist, C., Reiser, M., White, C., Steinbeck, G., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.059 · Cited by 662
Hoffmann, U., Moselewski, F., Nieman, K., Jang, I.-K., Ferencik, M., Rahman, A. M., Cury, R. C., Abbara, S., Joneidi-Jafari, H., Achenbach, S., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.041 · Cited by 566
Self-citationEarls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Hamon, M., Biondi-Zoccai, G. G. L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., & Hamon, M. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.028 · Cited by 460
Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M. (2007) · Radiology · doi:10.1148/radiol.2442061218 · Cited by 442
Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004) · Circulation · doi:10.1161/01.cir.0000145614.07427.9f · Cited by 413
Achenbach, S., Ropers, D., Hoffmann, U., MacNeill, B., Baum, U., Pohle, K., Brady, T. J., Pomerantsev, E., Ludwig, J., Flachskampf, F. A., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.09.053 · Cited by 408
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Self-citationLardo, A. C., Cordeiro, M. A. S., Silva, C., Amado, L. C., George, R. T., Saliaris, A. P., Schuleri, K. H., Fernandes, V. R., Zviman, M., Nazarian, S., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.521450 · Cited by 383
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Accuracy of 16-Row Multidetector Computed Tomography for the Assessment of Coronary Artery Stenosis
Garcia, M. J., Lessick, J., Hoffmann, M. H. K., & CATSCAN Study Investigators, F. T. (2006) · JAMA · doi:10.1001/jama.296.4.403 · Cited by 301
Pohle, K., Achenbach, S., MacNeill, B., Ropers, D., Ferencik, M., Moselewski, F., Hoffmann, U., Brady, T. J., Jang, I.-K., & Daniel, W. G. (2007) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2006.01.013 · Cited by 289
New Technology for Noninvasive Evaluation of Coronary Artery Disease
Di Carli, M. F., & Hachamovitch, R. (2007) · Circulation · doi:10.1161/circulationaha.106.629808 · Cited by 282
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280
Coles, D. R., Smail, M. A., Negus, I. S., Wilde, P., Oberhoff, M., Karsch, K. R., & Baumbach, A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.078 · Cited by 265
Noninvasive Coronary Angiography with 16–Detector Row CT: Effect of Heart Rate
Hoffmann, M. H. K., Shi, H., Manzke, R., Schmid, F. T., De Vries, L., Grass, M., Brambs, H.-J., & Aschoff, A. J. (2005) · Radiology · doi:10.1148/radiol.2341031408 · Cited by 264
Accuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Hamon, M., Morello, R., Riddell, J. W., & Hamon, M. (2007) · Radiology · doi:10.1148/radiol.2453061899 · Cited by 241
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., et al. (2005) · Radiology · doi:10.1148/radiol.2342031271 · Cited by 233
Kuettner, A., Kopp, A. F., Schroeder, S., Rieger, T., Brunn, J., Meisner, C., Heuschmid, M., Trabold, T., Burgstahler, C., Martensen, J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.015 · Cited by 228
Noncardiac Findings in Cardiac Imaging With Multidetector Computed Tomography
Onuma, Y., Tanabe, K., Nakazawa, G., Aoki, J., Nakajima, H., Ibukuro, K., & Hara, K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.04.071 · Cited by 215
Multislice CT imaging of anomalous coronary arteries
Shi, H., Aschoff, A. J., Brambs, H.-J., & Hoffmann, M. H. K. (2004) · European Radiology · doi:10.1007/s00330-004-2490-2 · Cited by 206
“cently been used to image coronary arteries and detect coronary artery pathology [10–12].”
MethodDesjardins, B., & Kazerooni, E. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820993 · Cited by 192
Noninvasive Imaging of Coronary Arteries: Current and Future Role of Multi–Detector Row CT
Schoenhagen, P., Halliburton, S. S., Stillman, A. E., Kuzmiak, S. A., Nissen, S. E., Tuzcu, E. M., & White, R. D. (2004) · Radiology · doi:10.1148/radiol.2321021803 · Cited by 190
Schroeder, S., Kuettner, A., Leitritz, M., Janzen, J., Kopp, A. F., Herdeg, C., Heuschmid, M., Burgstahler, C., Baumbach, A., Wehrmann, M., et al. (2004) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200407000-00003 · Cited by 183
“In addition, the new MDCT generation with 16 detector slices is already available with shorter examination times and stabilized image quality.(18) Further noninvasive imaging modalities such as magnetic resonance imaging and electron beam CT require no or less radiation.”
MethodSchoepf, U. J., Zwerner, P. L., Savino, G., Herzog, C., Kerl, J. M., & Costello, P. (2007) · Radiology · doi:10.1148/radiol.2441052145 · Cited by 180
“For visualization of the coronary artery tree at contrast-enhanced CT angiography, MIPs and MPRs are widely used and recommended as robust and easy-to-perform secondary visualization tools for data viewing (2,42,43).”
MethodLeschka, S., Scheffel, H., Desbiolles, L., Plass, A., Gaemperli, O., Valenta, I., Husmann, L., Flohr, T. G., Genoni, M., Marincek, B., et al. (2007) · Investigative Radiology · doi:10.1097/rli.0b013e31803b93cf · Cited by 172
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi326 · Cited by 172
Feuchtner, G. M., Dichtl, W., Friedrich, G. J., Frick, M., Alber, H., Schachner, T., Bonatti, J., Mallouhi, A., Frede, T., Pachinger, O., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.056 · Cited by 169
Janne d’Othée, B., Siebert, U., Cury, R., Jadvar, H., Dunn, E. J., & Hoffmann, U. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.05.003 · Cited by 161
Atherothrombosis and High-Risk Plaque
Fuster, V., Fayad, Z. A., Moreno, P. R., Poon, M., Corti, R., & Badimon, J. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.075 · Cited by 158
Evaluation of Coronary Venous Anatomy by Multislice Computed Tomography
Sun, J. P., Yang, X. S., Lam, Y. Y., Garcia, M. J., & Yu, C. M. (2012) · World Journal of Cardiovascular Surgery · doi:10.4236/wjcs.2012.24018 · Cited by 8
“These improvements have lead to acquisitions with shorter scan times with higher spatial and temporal resolutions [3-6].”
Background
Metadata
- Authors
- Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J.
- Venue
- Circulation
- Published
- 2002-10-15
- Volume
- 106
- Issue
- 16
- Pages
- 2051-2054
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2044774499
- Cited by
- 956
- References
- 4
- FWCI
- 92.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.