The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Angiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Abstract
Background —The angiographic presentation of in-stent restenosis (ISR) may convey prognostic information on subsequent target vessel revascularizations (TLR). Methods and Results —We developed an angiographic classification of ISR according to the geographic distribution of intimal hyperplasia in reference to the implanted stent. Pattern I includes focal (≤10 mm in length) lesions, pattern II is ISR>10 mm within the stent, pattern III includes ISR>10 mm extending outside the stent, and pattern IV is totally occluded ISR. We classified a total of 288 ISR lesions in 245 patients and verified the angiographic accuracy of the classification by intravascular ultrasound. Pattern I was found in 42% of patients, pattern II in 21%, pattern III in 30%, and pattern IV in 7%. Previously recurrent ISR was more frequent with increasing grades of classification (9%, 20%, 34%, and 50% for classes I to IV, respectively; P =0.0001), as was diabetes (28%, 32%, 39%, and 48% in classes I to IV, respectively; P <0.01). Angioplasty and stenting were used predominantly in classes I and II, whereas classes III and IV were treated with atheroablation. Final diameter stenosis ranged between 21% and 28% ( P =NS among ISR patterns). TLR increased with increasing ISR class; it was 19%, 35%, 50%, and 83% in classes I to IV, respectively ( P <0.001). Multivariate analysis showed that diabetes (odds ratio, 2.8), previously recurrent ISR (odds ratio, 2.7), and ISR class (odds ratio, 1.7) were independent predictors of TLR. Conclusions —The introduced angiographic classification is prognostically important, and it may be used for appropriate and early patient triage for clinical and investigational purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Serruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Fischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271
Self-citationPatterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Self-citationCatheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Teirstein, P. S., Massullo, V., Jani, S., Popma, J. J., Mintz, G. S., Russo, R. J., Schatz, R. A., Guarneri, E. M., Steuterman, S., Morris, N. B., et al. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362402 · Cited by 942
Self-citationArterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Self-citationTextbook of interventional cardiology
Topol, E. J. (1994) · Cited by 710
Nissen, S. E., Gurley, J. C., Grines, C. L., Booth, D. C., McClure, R., Berk, M., Fischer, C., & DeMaria, A. N. (1991) · Circulation · doi:10.1161/01.cir.84.3.1087 · Cited by 667
Arterial wall characteristics determined by intravascular ultrasound imaging: An in vitro study
Gussenhoven, E. J., Essed, C. E., Lancée, C. T., Mastik, F., Frietman, P., van Egmond, F. C., Reiber, J., Bosch, H., van Urk, H., Roelandt, J., et al. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90471-3 · Cited by 613
Tobis, J. M., Mallery, J., Mahon, D. J., et al. (1991) · Circulation · doi:10.1161/01.cir.83.3.913 · Cited by 600
Abizaid, A., Kornowski, R., Mintz, G. S., Hong, M. K., Abizaid, A. S., Mehran, R., Pichard, A. D., Kent, K. M., Satler, L. F., Wu, H., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00286-1 · Cited by 458
Self-citation
Cited by
Moses, J. W., Leon, M. B., Popma, J. J., Fitzgerald, P. J., Holmes, D. R., O'Shaughnessy, C., Caputo, R. P., Kereiakes, D. J., Williams, D. O., Teirstein, P. S., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035071 · Cited by 4,224
Self-citationWriting Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
Self-citationA Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O'Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032441 · Cited by 2,749
Self-citationWRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention
Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., Hollenberg, S. M., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.007 · Cited by 2,164
Self-citationGuidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Self-citation2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Self-citationLawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Self-citationTreatment of Coronary In-Stent Restenosis with a Paclitaxel-Coated Balloon Catheter
Scheller, B., Hehrlein, C., Bocksch, W., Rutsch, W., Haghi, D., Dietz, U., Böhm, M., & Speck, U. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061254 · Cited by 816
In-Stent Restenosis in the Drug-Eluting Stent Era
Dangas, G. D., Claessen, B. E., Caixeta, A., Sanidas, E. A., Mintz, G. S., & Mehran, R. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.028 · Cited by 803
Self-citationStone, G. W., Ellis, S. G., Cannon, L., Mann, J. T., Greenberg, J. D., Spriggs, D., O'Shaughnessy, C. D., DeMaio, S., Hall, P., Popma, J. J., et al. (2005) · JAMA · doi:10.1001/jama.294.10.1215 · Cited by 765
Self-citationStent-Based Delivery of Sirolimus Reduces Neointimal Formation in a Porcine Coronary Model
Suzuki, T., Kopia, G., Hayashi, S.-I., Bailey, L. R., Llanos, G., Wilensky, R., Klugherz, B. D., Papandreou, G., Narayan, P., Leon, M. B., et al. (2001) · Circulation · doi:10.1161/hc3601.093987 · Cited by 708
Self-citationSmith, S. C., Dove, J. T., Jacobs, A. K., Kennedy, J. W., Kereiakes, D., Kern, M. J., Kuntz, R. E., Popma, J. J., Schaff, H. V., Williams, D. O., et al. (2001) · Circulation · doi:10.1161/01.cir.103.24.3019 · Cited by 608
Kastrati, A., Mehilli, J., von Beckerath, N., Dibra, A., Hausleiter, J., Pache, J., Schühlen, H., Schmitt, C., Dirschinger, J., Schömig, A., et al. (2005) · JAMA · doi:10.1001/jama.293.2.165 · Cited by 605
Current Treatment of In-Stent Restenosis
Alfonso, F., Byrne, R. A., Rivero, F., & Kastrati, A. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.545 · Cited by 577
ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention
Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., Whitlow, P. L., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.001 · Cited by 532
Unverdorben, M., Vallbracht, C., Cremers, B., Heuer, H., Hengstenberg, C., Maikowski, C., Werner, G. S., Antoni, D., Kleber, F. X., Bocksch, W., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.839282 · Cited by 511
Byrne, R. A., Neumann, F.-J., Mehilli, J., Pinieck, S., Wolff, B., Tiroch, K., Schulz, S., Fusaro, M., Ott, I., Ibrahim, T., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61964-3 · Cited by 459
Stone, G. W., Ellis, S. G., & Cannon, L. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.11.049 · Cited by 435
Self-citationCoronary in-stent restenosis: Current status and future strategies
Lowe, H. C., Oesterle, S. N., & Khachigian, L. M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01742-9 · Cited by 414
Giustino, G., Colombo, A., Camaj, A., Yasumura, K., Mehran, R., Stone, G. W., Kini, A., & Sharma, S. K. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.05.017 · Cited by 413
Self-citationBuccheri, D., Piraino, D., Andolina, G., & Cortese, B. (2016) · Journal of Thoracic Disease · doi:10.21037/jtd.2016.10.93 · Cited by 397
Latib, A., Colombo, A., Castriota, F., Micari, A., Cremonesi, A., De Felice, F., Marchese, A., Tespili, M., Presbitero, P., Sgueglia, G. A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.020 · Cited by 364
Rittger, H., Brachmann, J., Sinha, A.-M., Waliszewski, M., Ohlow, M., Brugger, A., Thiele, H., Birkemeyer, R., Kurowski, V., Breithardt, O.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.015 · Cited by 362
Kang, S.-J., Mintz, G. S., Akasaka, T., Park, D.-W., Lee, J.-Y., Kim, W.-J., Lee, S.-W., Kim, Y.-H., Whan Lee, C., Park, S.-W., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.988436 · Cited by 359
Self-citationKandzari, D. E., Leon, M. B., Popma, J. J., Fitzgerald, P. J., O’Shaughnessy, C., Ball, M. W., Turco, M., Applegate, R. J., Gurbel, P. A., Midei, M. G., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.035 · Cited by 347
Self-citationAlfonso, F., Pérez-Vizcayno, M. J., Cárdenas, A., García del Blanco, B., García-Touchard, A., López-Minguéz, J. R., Benedicto, A., Masotti, M., Zueco, J., Iñiguez, A., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.063 · Cited by 313
Current Status of Rotational Atherectomy
Tomey, M. I., Kini, A. S., & Sharma, S. K. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.12.196 · Cited by 312
Classification and Clinical Impact of Restenosis After Femoropopliteal Stenting
Tosaka, A., Soga, Y., Iida, O., Ishihara, T., Hirano, K., Suzuki, K., Yokoi, H., Nanto, S., & Nobuyoshi, M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.036 · Cited by 303
Restenosis after PCI. Part 1: pathophysiology and risk factors
Jukema, J. W., Verschuren, J. J. W., Ahmed, T. A. N., & Quax, P. H. A. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2011.132 · Cited by 299
Shlofmitz, E., Iantorno, M., & Waksman, R. (2019) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.118.007023 · Cited by 289
Chen, S.-L., Santoso, T., Zhang, J.-J., Ye, F., Xu, Y.-W., Fu, Q., Kan, J., Paiboon, C., Zhou, Y., Ding, S.-Q., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.10.023 · Cited by 289
Lemos, P. A., Saia, F., Ligthart, J. M. R., Arampatzis, C. A., Sianos, G., Tanabe, K., Hoye, A., Degertekin, M., Daemen, J., McFadden, E., et al. (2003) · Circulation · doi:10.1161/01.cir.0000083366.33686.11 · Cited by 286
Habara, S., Mitsudo, K., Kadota, K., Goto, T., Fujii, S., Yamamoto, H., Katoh, H., Oka, N., Fuku, Y., Hosogi, S., et al. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.10.012 · Cited by 281
Alfonso, F., Pérez-Vizcayno, M. J., Cárdenas, A., García del Blanco, B., Seidelberger, B., Iñiguez, A., Gómez-Recio, M., Masotti, M., Velázquez, M. T., Sanchís, J., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.12.006 · Cited by 269
In stent restenosis: bane of the stent era
Mitra, A. K., & Agrawal, D. K. (2006) · Journal of Clinical Pathology · doi:10.1136/jcp.2005.025742 · Cited by 260
Vermeersch, P., Agostoni, P., Verheye, S., Van den Heuvel, P., Convens, C., Bruining, N., Van den Branden, F., & Van Langenhove, G. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.09.021 · Cited by 256
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Konigstein, M., Ben-Yehuda, O., Smits, P. C., Love, M. P., Banai, S., Perlman, G. Y., Golomb, M., Ozan, M. O., Liu, M., Leon, M. B., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.09.033 · Cited by 66
Self-citation
Metadata
- Authors
- Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B.
- Venue
- Circulation
- Published
- 1999-11-02
- Volume
- 100
- Issue
- 18
- Pages
- 1872-1878
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2026168678
- Cited by
- 1,258
- References
- 13
- FWCI
- 30.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.