The DOI matches its Crossref record.
Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction.
Abstract
BACKGROUND: Ventricular tachycardia reentry circuits in chronic infarct scars can contain slow conduction zones, which are difficult to distinguish from bystander areas adjacent to the circuit during catheter mapping. This study developed criteria for identifying reentry circuit sites using computer simulations. These criteria then were tested during catheter mapping in humans to predict sites at which radiofrequency current application terminated ventricular tachycardia. METHODS AND RESULTS: In computer simulations, effects of single stimuli and stimulus trains at sites in and adjacent to reentry circuits were analyzed. Entrainment with concealed fusion, defined as ventricular tachycardia entrainment with no change in QRS morphology, could occur during stimulation in reentry circuit common pathways and adjacent bystander sites. Pacing at reentry circuit common pathway sites, the stimulus to QRS (S-QRS) interval equals the electrogram to QRS interval (EG-QRS) during tachycardia. The postpacing interval from the last stimulus to the following electrogram equals the tachycardia cycle length. Pacing at bystander sites the S-QRS exceeds the EG-QRS interval when the conduction time from the bystander site to the circuit is short but may be less than or equal to the EG-QRS interval when the conduction time to the circuit is long. The postpacing interval, however, always exceeds the tachycardia cycle length. When conduction in the circuit slows during pacing, the S-QRS and postpacing intervals increase and the slowest stimulus train most closely reflects conduction times during tachycardia. Endocardial catheter mapping and radiofrequency ablation were performed during 31 monomorphic ventricular tachycardias in 15 patients with drug refractory ventricular tachycardia late after myocardial infarction. During ventricular tachycardia, trains of electrical stimuli or scanning single stimuli were evaluated before application of radiofrequency current at the same site. Radiofrequency current terminated ventricular tachycardia at 24 of 241 sites (10%) in 12 of 15 patients (80%). Ventricular tachycardia termination occurred more frequently at sites with entrainment with concealed fusion (odds ratio, 3.4; 95% confidence interval [CI], 1.4 to 8.3), a postpacing interval approximating the ventricular tachycardia cycle length (odds ratio, 4.6; 95% CI, 1.6 to 12.9) and an S-QRS interval during entrainment of more than 60 milliseconds and less than 70% of the ventricular tachycardia cycle length (odds ratio, 4.9; 95% CI, 1.4 to 17.1). Ventricular tachycardia termination was also predicted by the presence of isolated diastolic potentials or continuous electrical activity (odds ratio, 5.2; 95% CI, 1.8 to 15.5), but these electrograms were infrequent (8% of all sites). Combinations of entrainment with concealed fusion, postpacing interval, S-QRS intervals, and isolated diastolic potentials or continuous electrical activity predicted a more than 35% incidence of ventricular tachycardia termination during radiofrequency current application versus a 4% incidence when none suggested that the site was in the reentry circuit. Analysis of the postpacing interval and S-QRS interval suggested that 25% of the sites with entrainment with concealed fusion were in bystander areas not within the reentry circuit. At restudy 5 to 7 days later, 6 patients had no monomorphic ventricular tachycardia inducible, and inducible ventricular tachycardias were modified in 4 patients. None of these 10 patients have suffered arrhythmia recurrences during a follow-up of 316 +/- 199 days, although 4 continue to receive previously ineffective medications. CONCLUSIONS: Regions giving rise to reentry after myocardial infarction are complex and can include bystander areas, slow conduction zones, and isthmuses for impulse propagation at which radiofrequency current lesions can interrupt reentry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., Silka, M. J., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02528-7 · Cited by 1,266
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
Task Force on Sudden Cardiac Death of the European Society of Cardiology
Priori, S. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2824 · Cited by 903
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Self-citationWriting Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl199 · Cited by 523
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2019) · EP Europace · doi:10.1093/europace/euz132 · Cited by 475
Self-citation2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias
Cronin, E. M., Bogun, F. M., Maury, P., Peichl, P., Chen, M., Namboodiri, N., Aguinaga, L., Leite, L. R., Al-Khatib, S. M., Anter, E., et al. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.002 · Cited by 431
Self-citationCalkins, H., Epstein, A., Packer, D., Arria, A. M., Hummel, J., Gilligan, D. M., Trusso, J., Carlson, M., Luceri, R., Kopelman, H., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00615-x · Cited by 417
Self-citationAliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Self-citationExploring Postinfarction Reentrant Ventricular Tachycardia With Entrainment Mapping
Stevenson, W. G., Friedman, P. L., Sager, P. T., Saxon, L. A., Kocovic, D., Harada, T., Wiener, I., & Khan, H. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00065-x · Cited by 386
Self-citationThe 1998 NASPE Prospective Catheter Ablation Registry
SCHEINMAN, M. M., & HUANG, S. (2000) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2000.tb00891.x · Cited by 374
Hsia, H. H., Callans, D. J., & Marchlinski, F. E. (2003) · Circulation · doi:10.1161/01.cir.0000083725.72693.ea · Cited by 368
Nakagawa, H., Lazzara, R., Khastgir, T., Beckman, K. J., McClelland, J. H., Imai, S., Pitha, J. V., Becker, A. E., Arruda, M., Gonzalez, M. D., et al. (1996) · Circulation · doi:10.1161/01.cir.94.3.407 · Cited by 363
Cano, O., Hutchinson, M., Lin, D., Garcia, F., Zado, E., Bala, R., Riley, M., Cooper, J., Dixit, S., Gerstenfeld, E., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.05.032 · Cited by 350
Kalman, J. M., VanHare, G. F., Olgin, J. E., Saxon, L. A., Stark, S. I., & Lesh, M. D. (1996) · Circulation · doi:10.1161/01.cir.93.3.502 · Cited by 346
Self-citationKalman, J. M., Olgin, J. E., Saxon, L. A., Fisher, W. G., Lee, R. J., & Lesh, M. D. (1996) · Circulation · doi:10.1161/01.cir.94.3.398 · Cited by 344
Self-citationArenal, A., Glez-Torrecilla, E., Ortiz, M., Villacastín, J., Fdez-Portales, J., Sousa, E., del Castillo, S., Perez de Isla, L., Jimenez, J., & Almendral, J. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02623-2 · Cited by 343
Soejima, K., Stevenson, W. G., Maisel, W. H., Sapp, J. L., & Epstein, L. M. (2002) · Circulation · doi:10.1161/01.cir.0000030187.39852.a7 · Cited by 342
Self-citationSOSA, E., SCANAVACCA, M., D'AVILA, A., PICCIONI, J., SANCHEZ, O., VELARDE, J. L., SILVA, M., & REOLÃO, B. (1998) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1998.tb00907.x · Cited by 330
Cauchemez, B., Haissaguerre, M., Fischer, B., Thomas, O., Clementy, J., & Coumel, P. (1996) · Circulation · doi:10.1161/01.cir.93.2.284 · Cited by 312
Schilling, R. J., Peters, N. S., & Davies, D. W. (1998) · Circulation · doi:10.1161/01.cir.98.9.887 · Cited by 309
Catheter Ablation for Ventricular Tachycardia
Stevenson, W. G., & Soejima, K. (2007) · Circulation · doi:10.1161/circulationaha.106.655720 · Cited by 299
Self-citationNogami, A., Naito, S., Tada, H., Taniguchi, K., Okamoto, Y., Nishimura, S., Yamauchi, Y., Aonuma, K., Goya, M., Iesaka, Y., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00780-4 · Cited by 287
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Novel, Magnetically Guided Catheter for Endocardial Mapping and Radiofrequency Catheter Ablation
Faddis, M. N., Blume, W., Finney, J., Hall, A., Rauch, J., Sell, J., Bae, K. T., Talcott, M., & Lindsay, B. (2002) · Circulation · doi:10.1161/01.cir.0000038704.84304.6f · Cited by 280
TANNER, H., HINDRICKS, G., VOLKMER, M., FURNISS, S., KÜHLKAMP, V., LACROIX, D., DE CHILLOU, C., ALMENDRAL, J., CAPONI, D., KUCK, K., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01563.x · Cited by 265
Marchlinski, F. E., Zado, E., Dixit, S., Gerstenfeld, E., Callans, D. J., Hsia, H., Lin, D., Nayak, H., Russo, A., & Pulliam, W. (2004) · Circulation · doi:10.1161/01.cir.0000145154.02436.90 · Cited by 256
Dalal, D., Jain, R., Tandri, H., Dong, J., Eid, S. M., Prakasa, K., Tichnell, C., James, C., Abraham, T., Russell, S. D., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.049 · Cited by 255
Epstein, A. E., Miles, W. M., Benditt, D. G., Camm, A. J., Darling, E. J., Friedman, P. L., Garson, A., Harvey, J. C., Kidwell, G. A., Klein, G. J., et al. (1996) · Circulation · doi:10.1161/01.cir.94.5.1147 · Cited by 220
A novel pacing maneuver to localize focal atrial tachycardia
MOHAMED, U., SKANES, A. C., GULA, L. J., LEONG‐SIT, P., KRAHN, A. D., YEE, R., SUBBIAH, R., & KLEIN, G. J. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00664.x · Cited by 164
Left Septal Atrial Flutter: Electrophysiology, Anatomy, and Results of Ablation
Marrouche, N. F., Natale, A., Wazni, O. M., Cheng, J., Yang, Y., Pollack, H., Verma, A., Ursell, P., & Scheinman, M. M. (2004) · Circulation · doi:10.1161/01.cir.0000129439.03836.96 · Cited by 110
Differential effects of adenosine on focal and macroreentrant atrial tachycardia
MARKOWITZ, S. M., STEIN, K. M., MITTAL, S., SLOTWTNER, D. J., & LERMAN, B. B. (1999) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1999.tb00705.x · Cited by 88
Esato, M., Hindricks, G., Sommer, P., Arya, A., Gaspar, T., Bode, K., Bollmann, A., Wetzel, U., Hilbert, S., Kircher, S., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2008.12.013 · Cited by 58
Metadata
- Authors
- Stevenson, W. G., Khan, H., Sager, P., Saxon, L. A., Middlekauff, H. R., Natterson, P. D., & Wiener, I.
- Venue
- Circulation
- Published
- 1993-10
- Volume
- 88
- Issue
- 4
- Pages
- 1647-1670
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2066742771
- Cited by
- 909
- References
- 0
- FWCI
- 18.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.