HypoDE: Research Design and Methods of a Randomized Controlled Study Evaluating the Impact of Real-Time CGM Usage on the Frequency of CGM Glucose Values <55 mg/dl in Patients With Type 1 Diabetes and Problematic Hypoglycemia Treated With Multiple Daily Injections
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Systems for continuous glucose monitoring (CGM) have been available for a number of years, and numerous clinical studies have been performed with them. Interestingly, in many of these studies patients with an increased risk of hypoglycemic events were excluded. In addition, in most studies subjects were using a pump for insulin delivery. Therefore our knowledge about the benefit of CGM in patients employing multiple daily injections (MDI) of insulin is limited, especially when it comes to a reduction in the risk of low glucose events in high-risk individuals. We are planning to run a 26-week randomized controlled study in Germany (HypoDE, Hypoglycemia in Deutschland) that is focused on evaluating if such a reduction can be observed in patients on MDI with an increased risk of low glucose events. In all, 160 patients will participate in the study, randomized into the intervention group and control group. Ideally one would study if the frequency of severe hypoglycemic events is different between both groups. However, this would require such a large sample size and study duration, so for pragmatic reasons we will use low glucose levels <55 mg/dl (measured by CGM) for at least 20 minutes as a risk marker for severe hypoglycemic events. The results from the HypoDE study shall help determine the advantage of using CGM in subjects with type 1 diabetes with an increased risk of low glucose events treated with MDI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200002103420603 · Cited by 1,534 · cited 1×
“The most important risk factor for hypoglycemia unawareness and subsequent hypoglycemia problems in people with type 1 diabetes is a prior history of hypoglycemia.(30) Frequent hypoglycemia is associated with a downshift of glycemic threshold for endocrine and symptomatic counterregulatory responses toward low blood g…”
BackgroundThe Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Defining and Reporting Hypoglycemia in Diabetes
American Diabetes Association Workgroup on Hypoglycemia (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1245 · Cited by 1,146
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · cited 1×
“Although real-time CGM per se (that mean CGM only, without communicating with an insulin pump; subsequently the term CGM will be used in this sense) has been shown to reduce the amount of time a user spends at low glucose, it has not demonstrated to be effective in reducing such low glucose events in general and noctu…”
BackgroundGold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746 · cited 1×
“In fact, data suggest the existence of risk groups of people with type 1 diabetes, who account for the majority of SH events.(16,23,24,26,27) A key risk factor for SH in patients with type 1 diabetes is reduced hypoglycemia awareness.”
BackgroundThreshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652 · cited 1×
“- The duration for which glucose has to be below the selected threshold was also used in the ASPIRE study.(47) Secondary Endpoints Patients in both study groups will be instructed to document (advanced) hypoglycemic or SH events during the study duration as close as possible; they will be asked to note the date, time,…”
MethodClarke, W. L., Cox, D. J., Gonder-Frederick, L. A., Julian, D., Schlundt, D., & Polonsky, W. (1995) · Diabetes Care · doi:10.2337/diacare.18.4.517 · Cited by 651
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541 · cited 1×
“Yet, after more than a decade of availability, the evidence for usage of CGM to reduce the risk of hypoglycemic events (especially of severe hypoglycemic events [SH]) from a number of studies remains under debate.(1-6) However, in many of these studies first generations CGM systems were used; the analytical performanc…”
Backgroundthe SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Mechanisms of hypoglycemia-associated autonomic failure in diabetes
Cryer, P. E. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1215228 · Cited by 433 · cited 1×
“Neuroglycopenia narrows the window of opportunity for an effective self-treatment of low blood glucose values, enhancing the risk of SH, which has to be treated by the assistance of a third person or medical assistance.(31,32) Early detection and scrupulous avoidance of low glucose values can restore hypoglycemia awar…”
BackgroundRestoration of hypoglycaemia awareness in patients with long-duration insulin-dependent diabetes.
Cranston, I., Lomas, J., Amiel, S. A., Maran, A., & Macdonald, I. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91336-6 · Cited by 430
Ly, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Fanelli, C. G., Epifano, L., Rambotti, A. M., Pampanelli, S., Di Vincenzo, A., Modarelli, F., Lepore, M., Annibale, B., Ciofetta, M., Bottini, P., et al. (1993) · Diabetes · doi:10.2337/diab.42.11.1683 · Cited by 398
Prevalence of impaired awareness of hypoglycaemia in adults with Type 1 diabetes
Geddes, J., Schopman, J. E., Zammitt, N. N., & Frier, B. M. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02413.x · Cited by 387
Weinstock, R. S., Xing, D., Maahs, D. M., Michels, A., Rickels, M. R., Peters, A. L., Bergenstal, R. M., Harris, B., DuBose, S. N., Miller, K. M., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1589 · Cited by 338
Psychometric properties of the hypoglycemia fear survey-ii for adults with type 1 diabetes
Gonder-Frederick, L. A., Schmidt, K. M., Vajda, K. A., Greear, M. L., Singh, H., Shepard, J. A., & Cox, D. J. (2011) · Diabetes Care · doi:10.2337/dc10-1343 · Cited by 337
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Little, S. A., Leelarathna, L., Walkinshaw, E., Tan, H. K., Chapple, O., Lubina-Solomon, A., Chadwick, T. J., Barendse, S., Stocken, D. D., Brennand, C., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0030 · Cited by 237
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237 · cited 1×
“” However, in case a patient uses a meter that is shown in respective evaluation studies to have an insufficient measurement quality, this might be switched to one with an adequate quality.(56) Statistics A statistical analysis plan (SAP) will be established for this study.”
MethodFanelli, C., Pampanelli, S., Epifano, L., Rambotti, A. M., Ciofetta, M., Modarelli, F., Di Vincenzo, A., Annibale, B., Lepore, M., Lalli, C., et al. (1994) · Diabetologia · doi:10.1007/bf00404337 · Cited by 193
Intensified insulin therapy and the risk of severe hypoglycaemia
Bott, S., Bott, U., Berger, M., & Mühlhauser, I. (1997) · Diabetologia · doi:10.1007/s001250050769 · Cited by 180 · cited 1×
“In fact, data suggest the existence of risk groups of people with type 1 diabetes, who account for the majority of SH events.(16,23,24,26,27) A key risk factor for SH in patients with type 1 diabetes is reduced hypoglycemia awareness.”
BackgroundMaran, A., Lomas, J., Macdonald, I. A., & Amiel, S. A. (1995) · Diabetologia · doi:10.1007/bf00400601 · Cited by 102
O'Connell, S. M., Cooper, M. N., Bulsara, M. K., Davis, E. A., & Jones, T. W. (2011) · Diabetes Care · doi:10.2337/dc11-0748 · Cited by 81
Cited by
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Self-citationDeshmukh, H., Wilmot, E. G., Gregory, R., Barnes, D., Narendran, P., Saunders, S., Furlong, N., Kamaruddin, S., Banatwalla, R., Herring, R., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0738 · Cited by 175
“The benefits include improvements 69 in glycaemic control and hypoglycaemia[1-4].”
BackgroundHermanns, N., Heinemann, L., Freckmann, G., Waldenmaier, D., & Ehrmann, D. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819831695 · Cited by 66
Self-citationAcciaroli, G., Welsh, J. B., & Akturk, H. K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820982584 · Cited by 27
Metadata
- Authors
- Heinemann, L., Deiss, D., Hermanns, N., Graham, C., Kaltheuner, M., Liebl, A., & Price, D.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2015-03-09
- Volume
- 9
- Issue
- 3
- Pages
- 651-662
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2097339294
- Cited by
- 19
- References
- 27
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.