Comparative Accuracy of 17 Point-of-Care Glucose Meters
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The accuracy of point-of-care blood glucose (BG) meters is important for the detection of dysglycemia, calculation of insulin doses, and the calibration of continuous glucose monitors. The objective of this study was to compare the accuracy of commercially available glucose meters in a challenging laboratory study using samples with a wide range of reference BG and hemoglobin values. METHODS: Fresh, discarded blood samples from a hospital STAT laboratory were either used without modification, spiked with a glucose solution, or incubated at 37°C to produce 347 samples with an even distribution across reference BG levels from 20 to 440 mg/dl and hemoglobin values from 9 to 16 g/dl. We measured the BG of each sample with 17 different commercially available glucose meters and the reference method (YSI 2300) at the same time. We determined the mean absolute relative difference (MARD) for each glucose meter, overall and stratified by reference BG and by hemoglobin level. RESULTS: The accuracy of different meters widely, exhibiting a range of MARDs from 5.6% to 20.8%. Accuracy was lower in the hypoglycemic range, but was not consistently lower in samples with anemic blood hemoglobin levels. CONCLUSIONS: The accuracy of commercially available glucose meters varies widely. Although the sample mix in this study was much more challenging than those that would be collected under most use conditions, some meters were robust to these challenges and exhibited high accuracy in this setting. These data on relative accuracy and robustness to challenging samples may be useful in informing the choice of a glucose meter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In a 2017 study, however, only 2 of 17 commercial meters intended for home BGM use met the ISO standard (125).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [125]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, a study involving 17 commercially available home glucometers found that only two met the ISO standard and that accuracy decreased when BG was in the hypoglycemic range [5].”
From Non-Diabetic Hypoglycemia: Evaluation and Management in Adults (2025) · cites this paper as [5]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Sutheran, H. L., & Reynolds, T. (2015) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2014-202797 · Cited by 2
Retracted(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
Factors affecting blood glucose monitoring: sources of errors in measurement
Ginsberg, B. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300438 · Cited by 348
Unrecognized Anemia in Patients With Diabetes
Thomas, M. C., MacIsaac, R. J., Tsalamandris, C., Power, D., & Jerums, G. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1164 · Cited by 347
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
System Accuracy Evaluation of 27 Blood Glucose Monitoring Systems According to DIN EN ISO 15197
Freckmann, G., Baumstark, A., Jendrike, N., Zschornack, E., Kocher, S., Tshiananga, J., Heister, F., & Haug, C. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0128 · Cited by 195
Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200105000-00038 · Cited by 188
Research works printed but not linked: 3
- 6. Centers for Disease Control and Prevention. National Diabetes Statistics Report: Estimates of Diabetes and Its Burden in the United States, 2014. Atlanta, GA: US Department of Health and Human Services; 2014. [Google Scholar]
- 10. International Organization for Standardization. In vitro diagnostic test systems—requirements for blood-glucose monitoring systems for self-testing in managing diabetes Mellitus. EN ISO 15197:2003. (E). [Google Scholar]
- 11. International Organization for Standardization. In vitro diagnostic test systems—requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. ISO 15197:2013. (E). [Google Scholar]
Cited by
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
“8%.(146) Indeed, only one-third of the meters assessed”
BackgroundMethodPorumb, M., Stranges, S., Pescapè, A., & Pecchia, L. (2020) · Scientific Reports · doi:10.1038/s41598-019-56927-5 · Cited by 196
Flash forward: a review of flash glucose monitoring
Leelarathna, L., & Wilmot, E. G. (2018) · Diabetic Medicine · doi:10.1111/dme.13584 · Cited by 167
“[36] assessed 17 different commercially available glucose meters against the Yellow Springs reference method (YSI 2300) to determine the mean ARD.”
MethodSacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors
Klonoff, D. C., Parkes, J. L., Kovatchev, B. P., Kerr, D., Bevier, W. C., Brazg, R. L., Christiansen, M., Bailey, T. S., Nichols, J. H., & Kohn, M. A. (2018) · Diabetes Care · doi:10.2337/dc17-1960 · Cited by 144
“A BGM was considered to have met the standard unless the proportion compliant was in the “clear rejection zone” (7).”
MethodChallenges and perspectives in continuous glucose monitoring
van Enter, B. J., & von Hauff, E. (2018) · Chemical Communications · doi:10.1039/c8cc01678j · Cited by 154
A Multi-Patient Data-Driven Approach to Blood Glucose Prediction
Aliberti, A., Pupillo, I., Terna, S., Macii, E., Cataldo, S. D., Patti, E., & Acquaviva, A. (2019) · IEEE Access · doi:10.1109/access.2019.2919184 · Cited by 154
“criteria for accuracy described by International Organisation for Standardisation (ISO) [64], [65].”
MethodInfluentialThe screening and management of newborns at risk for low blood glucose
Narvey, M. R., & Marks, S. D. (2019) · Paediatrics & Child Health · doi:10.1093/pch/pxz134 · Cited by 133
The application of personal glucose meters as universal point-of-care diagnostic tools
Lisi, F., Peterson, J. R., & Gooding, J. J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111835 · Cited by 100
Jafri, R. Z., Balliro, C. A., El-Khatib, F., Maheno, M. M., Hillard, M. A., O'Donovan, A., Selagamsetty, R., Zheng, H., Damiano, E. R., & Russell, S. J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0449 · Cited by 90
“14 Therefore, although the POC PG meter is less accurate than reference methods, this should affect the apparent accuracy of all the CGM systems equally since, to our knowledge, factory calibrations and calibrations algorithms of CGM devices use the YSI as the standard.”
Self-citationEngineering Microneedles for Therapy and Diagnosis: A Survey
Xie, L., Zeng, H., Sun, J., & Qian, W. P. (2020) · Micromachines · doi:10.3390/mi11030271 · Cited by 93
“Thus, wearable healthcare devices visibly narrow the time gap between sampling and diagnosis [5], eliminate the risk of sample contamination, and allow chronic patients to real-time monitor physiological functions at home [6].”
BackgroundA Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials
Spanakis, E. K., Cook, C. B., Kulasa, K. M., Aloi, J., Bally, L., Davis, G. M., Dungan, K. M., Galindo, R. J., Mendez, C. E., Pasquel, F. J., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231191104 · Cited by 93
Massa, G. G., Gys, I., Op ‘t Eyndt, A., Bevilacqua, E., Wijnands, A., Declercq, P., & Zeevaert, R. (2018) · Hormone Research in Paediatrics · doi:10.1159/000487361 · Cited by 73
Forlenza, G. P., Kushner, T., Messer, L. H., Wadwa, R. P., & Sankaranarayanan, S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0401 · Cited by 63
“A 2017 study by Ekhlaspour investigated the comparative accuracy of 17 commercially available BGMs using venous blood samples, thereby eliminating error from skin contamination.(21) These BGMs were compared against YSI values for reference.”
MethodGuillot, F. H., Jacobs, P. G., Wilson, L. M., Youssef, J. E., Gabo, V. B., Branigan, D. L., Tyler, N. S., Ramsey, K., Riddell, M. C., & Castle, J. R. (2020) · Biosensors · doi:10.3390/bios10100138 · Cited by 54
Recent advances in diabetes treatments and their perioperative implications
Kuzulugil, D., Papeix, G., Luu, J., & Kerridge, R. K. (2019) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000000735 · Cited by 52
Chemical and Bio Sensing Using Graphene-Enhanced Raman Spectroscopy
Silver, A., Kitadai, H., Liu, H., Granzier-Nakajima, T., Terrones, M., Ling, X., & Huang, S. (2019) · Nanomaterials · doi:10.3390/nano9040516 · Cited by 47
“3 [93] Electrochemical—graphene electrode 0.”
Pors, A., Rasmussen, K. G., Inglev, R., Jendrike, N. R. M., Philipps, A., Ranjan, A. G., Vestergaard, V., Henriksen, J. E., Nørgaard, K., Freckmann, G., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02756 · Cited by 51
A Comprehensive Review of Continuous Glucose Monitoring Accuracy during Exercise Periods
Muñoz Fabra, E., Díez, J.-L., Bondia, J., & Laguna Sanz, A. J. (2021) · Sensors · doi:10.3390/s21020479 · Cited by 42
“Given that the blood glucose reference was not found to relevantly influence the effect of exercise on the accuracy of the sensors evaluated, we acknowledge the clear benefits of favouring SMBG devices (which keep improving in accuracy [82]) over gold-standard reference measurements, which are limited to laboratory an…”
BackgroundComparative assessment of blood glucose monitoring techniques: a review
Ahmadian, N., Manickavasagan, A., & Ali, A. (2022) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2022.2100496 · Cited by 51
Russell, S. J., Sala, R. D., Conaghan, P. G., Habib, G. S., Vo, Q., Manning, R., Kivitz, A., Davis, Y., Lufkin, J., Johnson, J. R., et al. (2018) · Rheumatology · doi:10.1093/rheumatology/key265 · Cited by 46
Self-citationAAV capsid prioritization in normal and steatotic human livers maintained by machine perfusion
Kim, J.-J., Kurial, S. N. T., Choksi, P. K., Nunez, M., Lunow-Luke, T., Bartel, J., Driscoll, J., Her, C. L., Dhillon, S., Yue, W., et al. (2025) · Nature Biotechnology · doi:10.1038/s41587-024-02523-6 · Cited by 47
Foreman, Y. D., Brouwers, M. C. G. J., Kallen, C., Pagen, D. M. E., van Greevenbroek, M. M. J., Henry, R. M. A., Koster, A., Wesselius, A., Schaper, N. C., & Stehouwer, C. D. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0385 · Cited by 47
Kemas, A. M., Youhanna, S., Zandi Shafagh, R., & Lauschke, V. M. (2021) · The FASEB Journal · doi:10.1096/fj.202001989rr · Cited by 41
Comparison of Continuous Glucose Monitoring Accuracy Between Abdominal and Upper Arm Insertion Sites
Steineck, I. I. K., Mahmoudi, Z., Ranjan, A., Schmidt, S., Jørgensen, J. B., & Nørgaard, K. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0014 · Cited by 40
Time in range in pregnancy: is there a role?
Wyckoff, J. A., & Brown, F. M. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0103 · Cited by 39
Rodin, D., Kirby, M. L., Sedogin, N., Shapiro, Y., Pinhasov, A., & Kreinin, A. (2019) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.12.014 · Cited by 35
O’Malley, E. G., Reynolds, C. M. E., O’Kelly, R., Killalea, A. G., Sheehan, S. R., & Turner, M. J. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz005 · Cited by 33
“This has been demonstrated in a study of the comparative accuracy of 17 POC glucose meters that included the Bayer Contour XT meter (26).”
BackgroundDiagnosis of gestational diabetes mellitus will be flawed until we can measure glucose
Bruns, D. E., Metzger, B. E., & Sacks, D. B. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz027 · Cited by 30
“Better results might have been obtained with a different meter, but that points to another danger in concluding that glucose meters can be used for diagnosis of GDM: Meters vary in analytical performance (13).”
BackgroundPersonal Versus Professional Continuous Glucose Monitoring: When to Use Which on Whom
Longo, R. R., & Sperling, S. B. (2019) · Diabetes Spectrum · doi:10.2337/ds18-0093 · Cited by 36
“It is also worth addressing that the MARD in relation to laboratory glucose values of 17 current blood glucose meters was found to range from 5 to 22%, with higher MARD values in the settings of hypoglycemia and hyperglycemia (39).”
Marks, B. E., Williams, K. M., Sherwood, J. S., & Putman, M. S. (2021) · Journal of Clinical & Translational Endocrinology · doi:10.1016/j.jcte.2021.100282 · Cited by 39
“[48] Ekhlaspour L, Mondesir D, Lautsch N, Balliro C, Hillard M, Magyar K, et al.”
BackgroundMethodBarmanray, R., Kyi, M., Worth, L. J., Colman, P. G., Churilov, L. P., Fazio, T. N., Rayman, G. A., Gonzalez, V., Hall, C., & Fourlanos, S. (2024) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgae051 · Cited by 33
Personalized diabetes monitoring platform leveraging IoMT and AI for non-invasive estimation
Padmavilochanan, D., Pathinarupothi, R. K., Menon, K. A. U., Kumar, H., Guntha, R., Ramesh, M. V., & Rangan, P. V. (2023) · Smart Health · doi:10.1016/j.smhl.2023.100428 · Cited by 33
The use of mice in diabetes research: The impact of experimental protocols
Kennard, M. R., Gatward, L. F. D., Roberts, A. G., White, E. R. P., Nandi, M., & King, A. (2021) · Diabetic Medicine · doi:10.1111/dme.14705 · Cited by 31
Metabolism-Driven High-Throughput Cancer Identification with GLUT5-Specific Molecular Probes
Kannan, S., Begoyan, V., Fedie, J. R., Xia, S., Weseliński, Ł. J., Tanasova, M., & Rao, S. (2018) · Biosensors · doi:10.3390/bios8020039 · Cited by 27
Larose, S., RABASA-LHORET, R. P. R., Roy‐Fleming, A., Suppère, C., Tagougui, S., Messier, V., & Taleb, N. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0400 · Cited by 31
Farhoudi, N., Laurentius, L. B., Magda, J. J., Reiche, C. F., & Solzbacher, F. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00844 · Cited by 28
Nagl, K., Berger, G., Aberer, F., Ziko, H., Weimann, K., Bozic, I., Rami-Merhar, B. M., & Mader, J. K. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13160 · Cited by 24
Self-measurement of Blood Glucose and Continuous Glucose Monitoring – Is There Only One Future?
Heinemann, L., & Stuhr, A. (2018) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2018.14.2.24 · Cited by 30
“8%.(37) Only some SMBG systems were robust and exhibited a high degree of accuracy.”
BackgroundLundemose, S. B., Laugesen, C., Ranjan, A. G., & Nørgaard, K. (2023) · Sensors · doi:10.3390/s23229256 · Cited by 21
“BGM was performed every 10 min during the exercise session using a Contour Next One ( BGM was performed every 10 min during the exercise session using a Contour Next One (Ascensia, Baal, Switzerland) [14] blood glucose meter.”
Diabetes technology in people with diabetes and advanced chronic kidney disease
Galindo, R. J., Soliman, D., Cherñavvsky, D. R., & Rhee, C. M. (2024) · Diabetologia · doi:10.1007/s00125-024-06244-y · Cited by 26
“…available blood glucose meters demonstrated that accuracy varied substantially, with mean absolute relative differences (MARDs) ranging from 5.6% to 20.8%, with less reliability in participants with anaemia [25], which is a very frequent complication in people with advanced stages of CKD and ESKD.”
BackgroundInfluentialManaging discordance between HbA 1c and glucose management indicator
Lenters‐Westra, E., Fokkert, M. J., Kilpatrick, E. S., Schleicher, E. D., Pilla, S. J., English, E., & van Dijk, P. R. (2025) · Diabetic Medicine · doi:10.1111/dme.70023 · Cited by 21
“33,34 Incorrect timing of the calibration (during a meal or insulin bolus) when the discrepancy in glucose between interstitial and blood will be greatest will result in the CGM glucose values being misaligned with the blood glucose value, which will ultimately lead to a GMI incorrectly lower or…”
Clinical evaluation of a polarization-based optical noninvasive glucose sensing system
Leung, H. M. C., Gong, C., Geiser, L., Fivekiller, E. E., Bui, N., Vu, T. N., Prioleau, T., Forlenza, G. P., Liu, Q., & Zhou, X. (2025) · Scientific Reports · doi:10.1038/s41598-025-92515-6 · Cited by 20
Tschaikner, M., Powell, K., Jungklaus, M., Fritz, M., Ellmerer, M., Hovorka, R., Lane, S., Pieber, T. R., & Regittnig, W. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2925434 · Cited by 19
“in the current study (Abbott FreeStyle Freedom Lite) was previously found to be one of the most accurate glucose test strip devices available [42], [43].”
BackgroundSouza, M. I. O., da Mota, A. F., Pepino, V. M., Carmo, J. P., & Borges, B. V. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3033970 · Cited by 17
“mercial blood glucose sensor is the Contour Next [28],”
InfluentialTwigg, S. M., Lim, S. K., Yoo, S.-H., Chen, L., Bao, Y., Kong, A. P. S., Yeoh, E. C. K., Chan, S. P., Robles, J., Mohan, V., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231176533 · Cited by 17
“17 This highlights the need for blood glucose meters to adhere to the accuracy assessment, design verification, and performance validation guidelines outlined by ISO 15197:2013.”
MethodHow conclusive is the CONCLUDE trial?
Prato, S. D. (2020) · Diabetologia · doi:10.1007/s00125-020-05086-8 · Cited by 16
Accuracy of a Continuous Glucose Monitor During Pediatric Type 1 Diabetes Inpatient Admissions
Cobry, E. C., Pyle, L., WATERMAN, L. A., Forlenza, G. P., Towers, L., KARAMI, A. J., Jost, E., Berget, C., & Wadwa, R. P. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0375 · Cited by 15
Performance of commercially-available cholesterol self-tests
Kurstjens, S., Gemen, E. F. A., Walk, S., Njo, T. L., Krabbe, J. G., Gijzen, K., Elisen, M. G. L. M., & Kusters, R. (2021) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563221992393 · Cited by 13
“Many studies comparing point-of-care equipment or self-tests assess their performance on residual venous plasma samples or venous whole blood, instead of using capillary blood directly taken from a finger prick.(12,13) Moreover, the plasma cholesterol concentrations measured by our routine chemistry analysers were val…”
MethodFreckmann, G., Baumstark, A., Jendrike, N., Mende, J., Schauer, S., Link, M., Pleus, S., & Haug, C. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820948873 · Cited by 12
Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions
WATERMAN, L. A., Pyle, L., Forlenza, G. P., Towers, L., KARAMI, A. J., Jost, E., Berget, C., Wadwa, R. P., & Cobry, E. C. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0542 · Cited by 16
“POC glucose measures were obtained using Nova Biomedical StatStrip (MARD 6%), 19 which was specifically developed for use in critically ill patients and used by CHCO in the ICUs and medical floors.”
Wang, Y., Plebani, M., Sciacovelli, L., Zhang, S., Wang, Q., & Zhou, R. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23327 · Cited by 16
Predictive Analysis and Prognostic Approach of Diabetes Prediction with Machine Learning Techniques
Omana, J., & Moorthi, M. (2021) · Wireless Personal Communications · doi:10.1007/s11277-021-08274-w · Cited by 14
Recent Developments in Personal Glucose Meters as Point-of-Care Testing Devices (2020–2024)
Yang, D.-N., Geng, S., Rong, J., & Zhang, H. (2024) · Biosensors · doi:10.3390/bios14090419 · Cited by 11
“This method demonstrates the capacity to detect glucose levels within the range of 0.6–33.0 mmol/L [7].”
MethodInfluentialHenao-Pabon, G., Gao, N., Prasad, K. S., & Li, X. (2023) · Biosensors · doi:10.3390/bios13050566 · Cited by 12
“Only two of them meet the ISO (International Organization for Standardization) 2013 criteria for the international standards for blood glucose monitoring systems [14,15].”
BackgroundIGZO MESFET with enzyme-modified Schottky gate electrode for glucose sensing
Kaczmarski, J., Jankowska‐Śliwińska, J., & Borysiewicz, M. A. (2019) · Japanese Journal of Applied Physics · doi:10.7567/1347-4065/ab1a65 · Cited by 13
Non-Diabetic Hypoglycemia: Evaluation and Management in Adults
Looi, E., & Lawler, H. M. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14134393 · Cited by 13
“However, a study involving 17 commercially available home glucometers found that only two met the ISO standard and that accuracy decreased when BG was in the hypoglycemic range [5].”
In Vitro System for Evaluation of Biosensors in Controlled Dynamic Environmental Conditions
Ko, B. S., Zavareh, A. T., & McShane, M. J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3334366 · Cited by 10
“…of the system outputs with a survey of mean absolute relative difference (MARD) values for a variety of commercially available glucose monitors at different ranges suggests that the system can reliably produce glucose values within the measurement absolute errors of the glucose monitors [50].”
BackgroundOstendorf, A., Gräfen, M., Delbeck, S., Busch, H., & Heise, H. M. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2289625 · Cited by 10
“strips have been developed and tested for their performance [8, 9], but based on this technology only scarce data on the daily time-dependent variable glucose profile are available, especially if such information is required for intensified insulin therapy.”
BackgroundAdvances in Care for Insulin-Requiring Patients Without Closed Loop
Lal, R., Buckingham, B. A., & Maahs, D. M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0084 · Cited by 10
“8% for the Nipro SideKick.(27) CGM offers accuracy within this range and will soon operate independently of the glucometer.”
BackgroundInfluentialLin, Y. K., Agni, A., Chuisano, S. A., Fetters, M. D., Funnell, M. M., Pop‐Busui, R., & DeJonckheere, M. J. (2023) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106231168859 · Cited by 11
Makkar, B. M., Agarwal, S., Seshadri, K., Kesavadev, J., Chawla, M. S., & Saboo, B. (2024) · International journal of clinical metabolism and diabetes. · doi:10.1177/30502071241293567 · Cited by 13
“…±15% for glucose values ≥100 mg/dL. Glucose meters adhering to ISO 2013 standards should be used for SMBG. 27 Although some research has been conducted to compare standard glucose meters, 28,29 there is a lack of sufficient data about the comparison of standard glucose meters in the Indian context.”
Inman, M., Parker, K., Strueby, L., Lyon, A. W., & Lyon, M. E. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819884923 · Cited by 8
Fakheran, O., Bencze, B., Mischak, I., Végh, D., & Payer, M. (2024) · Clinical Oral Investigations · doi:10.1007/s00784-024-05685-4 · Cited by 10
“It is important to emphasize the use of FDA approved glucometers in order to ensure the accuracy of all measurements.”
Immanuel, J., Kongbrailatpam, T., Rajagopal, R., & Simmons, D. S. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16209 · Cited by 8
The Personal Glucose Meter as the Measurement Principle in Point-of-Care Applications
Cano, M., & del Valle, M. (2025) · Biosensors · doi:10.3390/bios15020121 · Cited by 7
“First, PGMs are designed to measure glucose in the ranges from 30 to 600 mg/dl, depending on the sensor used [19], which covers the dynamic range of glucose in people with diabetes.”
Chen, L., Yang, S., Dotzert, M. S., Melling, C. W. J., & Zhang, J. (2023) · Journal of Materials Chemistry B · doi:10.1039/d2tb01927b · Cited by 6
Nastiti, A. N., & Christyaningsih, J. (2019) · Media Gizi Indonesia · doi:10.20473/mgi.v14i1.35-43 · Cited by 31
Surveillance accuracy of smartphone-dependent glucose meters in the measurement of plasma glucose
Mondal, H., Mondal, S., & Biri, S. K. (2020) · Indian Journal of Endocrinology and Metabolism · doi:10.4103/ijem.ijem_580_19 · Cited by 6
Nonadjunctive Use of Continuous Glucose Monitoring: The End of Fingersticks?
Beck, R. W., Brown, S. A., Lum, J. W., & Kovatchev, B. P. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0387 · Cited by 7
“7 Although not as accurate as the most accurate BGMs, CGM accuracy is now equal to or better than the accuracy of many BGMs. 8,9 During time periods without rapid fluctuations in the blood glucose concentration, the CGM measurement of interstitial glucose lags behind blood glucose by about 4 min.”
Simulating Realistic Continuous Glucose Monitor Time Series By Data Augmentation
Gomez, L., Toye, A. A., Hum, R. S., & Kleinberg, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231181138 · Cited by 7
Setford, S. J., Grady, M., Mackintosh, S., Donald, R., & Levy, B. L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818776668 · Cited by 5
Hypoglycemia in the Toddler and Child
Wolfsdorf, J. I., & Stanley, C. A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-62520-3.00023-3 · Cited by 6
Dahya, K., Kuiper, H. C., Kingsley, S. W., Danilenko, U., & Vesper, H. W. (2025) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2025.04.005 · Cited by 4
“One study indicated that the accuracy of different POCT devices varied widely, with a mean absolute relative difference (MARD) of up to 20.8 % [3].”
InfluentialGlucose monitoring in diabetes: from clinical studies to real‐world practice
Sagar, R. C., Abbas, A., & Ajjan, R. (2019) · Practical Diabetes · doi:10.1002/pdi.2215 · Cited by 5
A Comprehensive Review on the Accuracy Determination Methods for Glucose Meters
Kesavadev, J., Saboo, B., Gupta, A. S., Sreelakshmi, R., & Krishnan, G. (2023) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_1_24 · Cited by 3
Moriuchi, T., Otaki, Y., Satou, H., Chai, F., Hayashida, Y., Aikawa, R., Sugiyama, T., & Sode, K. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211060865 · Cited by 2
Abreu, C., Miranda, F., Dabrowska, A., & Felgueiras, P. (2019) · AIP conference proceedings · doi:10.1063/1.5114250 · Cited by 3
“As reported by Ekhlaspour et al in [2], the accuracy of commercially available blood glucose meters varies significantly.”
MethodResultHospital Diabetes Meeting 2022
Huang, J. K., Yeung, A. M., Nguyen, K. T., Xu, N. Y., Preiser, J., Rushakoff, R. J., Seley, J. J., Umpierrez, G. E., Wallia, A., Drincic, A., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221110878 · Cited by 4
“46 A comparison of hypoglycemia detection using POC BGM and CGM is presented in Figure 8.”
MethodComparative study of i-SENS glucometers in neonates using capillary blood samples
Kim, H. N., & Yoon, S. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1367 · Cited by 3
Setford, S. J., Liu, Z., McColl, D., Phillips, S., Cameron, H., & Grady, M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211039465 · Cited by 5
Glycemic Targets and Glucose Monitoring
Oser, T. K., & Oser, S. M. (2022) · Primary Care Clinics in Office Practice · doi:10.1016/j.pop.2021.11.002 · Cited by 3
Impact of hematocrit levels on the accuracy of specific blood glucose meters: A hospital‐based study
Pham, H. N., Pham, P. N. H., Phan, H. T., Cao, L. T., Thoi, H. T. T., Thanh, T. D., & Truong, T. T. A. (2024) · Journal of Diabetes Investigation · doi:10.1111/jdi.14276 · Cited by 5
“The present study differs from other studies 9 – 11 , as we used the CLSI standard to assess meters ’ accuracies, precisions and hematocrit, whereas others used international organization standard 15197 to assess accuracies.”
Seaser, J., & Sherman, B. (2024) · JEM Reports · doi:10.1016/j.jemrpt.2024.100136 · Cited by 3
O'Donnell, D. J. P., Burns, S., Drever, S., Quesnelle, L., & Yuen, B. (2025) · JMIR Diabetes · doi:10.2196/73485 · Cited by 2
“The top seven highest-performing fingerstick glucometers have MARDs between 5.6% and 8.2% versus reference measurements, compared with 9.2% for FreeStyle Libre 2 and 12.8% for another CGM system [36-38].”
InfluentialYoo, J. W. S., Wang, R., Kyi, M., Fourlanos, S., & Barmanray, R. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261427437 · Cited by 2
“66 Additionally, hospitals vary in their practices of BG testing frequencies and thresholds.”
Wang, X., Peng, H., Xiao, H., Li, H., He, J., Chen, L., Qiu, X., Wang, K., Hu, X., Guo, X., et al. (2026) · Small Structures · doi:10.1002/sstr.70429 · Cited by 2
“The glucose concentrations obtained from the sensor were compared with those measured using a commercial glucose meter, yielding a mean absolute relative difference of 6.67%, which demonstrated excellent accuracy and precision [65].”
InfluentialContinuous Glucose Monitors for Insulin Dosing
Beck, R. W. (2018) · JAMA · doi:10.1001/jama.2018.0185 · Cited by 2
Chundawat, S. P. S. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.21.106468 · Cited by 2
Patient and glucometer: how can glucose self-monitoring be improved?
Kononova, Y. A., Babenko, A. Y., & Bregovskiy, V. B. (2024) · Meditsinskiy sovet = Medical Council · doi:10.21518/ms2024-259 · Cited by 1
Engineered Nanoparticles for μPAD Nucleic Acid Detection
Morgan, R. L., Zehnder, L. J., Jenkin, M. A., Alonso, E., Haunz, S., Bevil, A., & Scott, D. F. (2025) · ACS Omega · doi:10.1021/acsomega.4c11390 · Cited by 1
Accuracy of Glucose Meter Technologies in Low vs High Blood Sugar Ranges: A Bayesian Meta-Analysis
Sujimongkol, C., Daochai, S., Wichakhrueang, S., & Daochai, C. (2025) · Biomedical Engineering International Conference · doi:10.1109/bmeicon66226.2025.11113812 · Cited by 1
Kikula, A. I., Ramaiya, K. L., Sirili, N. S., Mkonyi, M. A., Msumi, R. J., Macha, J., Pembe, A. B., Peñalvo, J. L., & Beňová, L. (2025) · PLOS Global Public Health · doi:10.1371/journal.pgph.0004696 · Cited by 1
Granderson, D. M., Camic, C. L., Chomentowski, P. J., Howell, S. M., & Sebastião, É. (2019) · Kinesiology · doi:10.26582/k.51.2.10 · Cited by 1
“In addition, Ekhlaspour et al. (2017) reported overall MARD (±SD) values ranging from 5.6 (±6.4) to 20.8 (±16.6) for 17 different handheld blood glucose monitors versus the YSI 2300, with the Nova Max Plus ranking 8th for the lowest MARD (9.7).”
BackgroundInfluentialComparative Evaluation of the Precision and Accuracy of Five Available Glucometers in India
Kesavadev, J., Shankar, A., Chandran, G. B., Sreelakshmi, R., & Basanth, A. (2024) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_44_24 · Cited by 2
Current state of continuous glucose monitoring. Minirewiew
Friedecky, B., & Kratochvíla, J. (2020) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2020.023 · Cited by 2
Metadata
- Authors
- Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J.
- Affiliations
- Massachusetts General Hospital (US)
- Massachusetts General Hospital Diabetes Research Center, Boston, MA, USA
- Corresponding author
- Russell, Steven J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2016-10-03
- Volume
- 11
- Issue
- 3
- Pages
- 558-566
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC5505415
- OpenAlex
- W2529767183
- Semantic Scholar
- 5e3e282622eb98bf27bbfad30cef36065db8a325
- Cited by
- 127
- References
- 40
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 12 · 2023: 13 · 2022: 5 · 2021: 13 · 2020: 21 · 2019: 24 · 2018: 16
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (R01DK097657)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Keywords
- point-of-care glucose meters, blood glucose measurement accuracy, mean absolute relative difference, hemoglobin interference, anemia, hypoglycemia, insulin dose calculation
- MeSH terms
- Data Accuracy, Blood Glucose, Humans, Blood Glucose Self-Monitoring, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.