Cutaneous Complications With Continuous or Flash Glucose Monitoring Use: Systematic Review of Trials and Observational Studies
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background: Continuous glucose monitoring (CGM)/flash glucose monitoring (FGM) use in diabetes management is increasing. Cutaneous complications associated with these devices were reported. We conducted a systematic review to provide an overview of cutaneous complications with CGM/FGM use. Methods: We identified observational studies and intervention trials that report on cutaneous complications with CGM/FGM use up to January 14, 2019. Studies were identified through Medline, Embase, and PubMed, or with hand searching of the previous publications. Screening was duplicated and data extracted to consider four main themes: incidence rate and severity, participant perspectives of cutaneous complications, potential solutions, and future directions in diabetic technology relevant to reducing cutaneous complications. Results: A total of 54 eligible studies were identified. The overall event rate of cutaneous complications reported from 19 trials was one event per eight weeks of sensor wear-time of which 1.5% were considered severe. The most common cutaneous complications were wear-related erythema, itching, and induration. Although skin irritations were the most common cause of CGM/FGM discontinuation, most users experienced less pain or discomfort with CGM/FGM than capillary blood glucose testing. Future technological advances may reduce, but not eliminate cutaneous complications. Conclusion: The incidence rate of reported cutaneous complications with CGM/FGM use from the available literature is low, with one event per eight weeks of sensor wear-time. Reported complication severity was also low, leading to low rates of CGM/FGM discontinuation. However, there appear to be discrepancies between reporting in trial and observational data. Greater constancy in reporting is necessary to understand the frequency of this issue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
Carbohydrate quality and human health: a series of systematic reviews and meta-analyses
Reynolds, A., Mann, J., Cummings, J., Winter, N., Mete, E., & Te Morenga, L. (2019) · The Lancet · doi:10.1016/s0140-6736(18)31809-9 · Cited by 1,630
Self-citationContinuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685 · cited 2×
“Sensor insertion pain or bleeding was not considered a deterrent of use for the majority of individuals.(31,53) Cutaneous complications are often given as a reason for discontinuing CGM/FGM use.”
Background(2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.193 · Cited by 653 · cited 1×
“Achieving healthy glycemic control is a critical goal for those with diabetes given the increased risk of both micro- and macrovascular complications.(1,2) Crucial to achieving this is frequent self-monitoring of glucose.”
BackgroundPickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Miller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505
Postprandial Glucose Regulation and Diabetic Complications
Ceriello, A. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.19.2090 · Cited by 362 · cited 1×
“Achieving healthy glycemic control is a critical goal for those with diabetes given the increased risk of both micro- and macrovascular complications.(1,2) Crucial to achieving this is frequent self-monitoring of glucose.”
BackgroundZiegler, R., Heidtmann, B., Hilgard, D., Hofer, S., Rosenbauer, J., Holl, R., & DPV-Wiss-Initiative, F. T. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2010.00650.x · Cited by 334 · cited 1×
“Crucial to achieving this is frequent self-monitoring of glucose.(3,4) Given the limitations of traditional capillary glucose monitoring,(5) interstitial glucose monitoring such as continuous glucose monitoring (CGM) and flash glucose monitoring (FGM) is growing in popularity.”
BackgroundEffectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · cited 1×
“Several publications have considered new technologies in glucose sensing that may modify the risk of cutaneous complications.(71,73) These technologies can be considered by their degree of invasiveness.”
BackgroundChico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0255-6 · Cited by 188
Poolsup, N., Suksomboon, N., & Kyaw, A. M. (2013) · Diabetology & Metabolic Syndrome · doi:10.1186/1758-5996-5-39 · Cited by 179
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168
Berg, A. K., Nørgaard, K., Thyssen, J. P., Zachariae, C., Hommel, E., Rytter, K., & Svensson, J. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0088 · Cited by 87 · cited 2×
“Data from observational studies indicate that more than 70% of participants have experienced cutaneous complications related to CGM/FGM use at some point, with itch, eczema, and insertion wounds the most commonly reported complications.(24,25,63)”
BackgroundKamann, S., Aerts, O., & Heinemann, L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818762946 · Cited by 85 · cited 1×
“In practical terms, options include adequate drying prior to insertion and the use of various supplemental products such as adhesive barriers, tackifiers (to improve adhesion), or possibly off-label steroid sprays prior to insertion for those with known prior reactions (eg, fluticasone).(16,17,20,65,68,69) To minimize…”
BackgroundTsalikian, E., Fox, L., Weinzimer, S., Buckingham, B., White, N. H., Beck, R., Kollman, C., Xing, D., Ruedy, K., & Diabetes Research in Children Network (DirecNet) Study Group (2012) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00837.x · Cited by 83 · cited 2×
“Several studies reported severity of cutaneous complications.(36,37,40,47,48,55,56,59,60,62) Overall, 78.”
BackgroundAdhesives Used for Diabetes Medical Devices: A Neglected Risk With Serious Consequences?
Heinemann, L., & Kamann, S. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662949 · Cited by 74 · cited 1×
“These often involve degrees of allergic contact dermatitis from CGM/FGM adhesives(15-18) and pose a management challenge for both patients and healthcare professionals.(19) It is important to be able to counsel prospective users of CGM/FGM with accurate information on the potential of cutaneous complications, so that…”
BackgroundCosson, E., Hamo-Tchatchouang, E., Dufaitre-Patouraux, L., Attali, J.-R., Pariès, J., & Schaepelynck-Bélicar, P. (2009) · Diabetes & Metabolism · doi:10.1016/j.diabet.2009.02.006 · Cited by 57
Landau, Z., Abiri, S., Gruber, N., Levy-Shraga, Y., Brener, A., Lebenthal, Y., Barash, G., Pinhas-Hamiel, O., & Rachmiel, M. (2018) · Acta Diabetologica · doi:10.1007/s00592-018-1218-8 · Cited by 48
Evaluation of flash glucose monitoring after long-term use: a pediatric survey
Vergier, J., Samper, M., Dalla-Vale, F., Ventura, V., Baucher, F., Joubert, F., Pons, C., De Oliveira, M., Salet, R., Faure-Galon, N., et al. (2019) · Primary Care Diabetes · doi:10.1016/j.pcd.2018.08.004 · Cited by 32 · cited 1×
“Data from observational studies indicate that more than 70% of participants have experienced cutaneous complications related to CGM/FGM use at some point, with itch, eczema, and insertion wounds the most commonly reported complications.(24,25,63)”
BackgroundDepartment of Children’s Diabetology, S. O. M. I. K., Deja, G., Kłeczek, M., The Students’ Scientific Association at the Department of Children’s Diabetology, M. U. O. S. I. K., Chumięcki, M., Tychy, M. H. I., Strzała-Kłeczek, A., Special Outpatient Clinic of Diabetology of the Upper Silesian Child Health Centre in Katowice, Deja, R., Department of Computer Science, T. U. O. D. G., et al. (2018) · Pediatric Endocrinology Diabetes and Metabolism · doi:10.18544/pedm-24.01.0098 · Cited by 16
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
de Bock, M., Codner, E., Craig, M. E., Huynh, T., Maahs, D. M., Mahmud, F. H., Marcovecchio, L., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13455 · Cited by 254
Self-citation
Metadata
- Authors
- Asarani, N. A. M., Reynolds, A. N., Boucher, S. E., de Bock, M., & Wheeler, B. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2019-08-27
- Volume
- 14
- Issue
- 2
- Pages
- 328-337
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2970752787
- Cited by
- 81
- References
- 27
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.