Development and Applications of Portable Biosensors
Open accessThe DOI matches its Crossref record; 115 of the 115 references it cites were found in a registry or an index.
Abstract
The significance of microfluidics-based and microelectromechanical systems-based biosensors has been widely acknowledged, and many reviews have explored their potential applications in clinical diagnostics, personalized medicine, global health, drug discovery, food safety, and forensics. Because health care costs are increasing, there is an increasing need to remotely monitor the health condition of patients by point-of-care-testing. The demand for biosensors for detection of biological warfare agents has increased, and research is focused on ways of producing small portable devices that would allow fast, accurate, and on-site detection. In the past decade, the demand for rapid and accurate on-site detection of plant disease diagnosis has increased due to emerging pathogens with resistance to pesticides, increased human mobility, and regulations limiting the application of toxic chemicals to prevent spread of diseases. The portability of biosensors for on-site diagnosis is limited due to various issues, including sample preparation techniques, fluid-handling techniques, the limited lifetime of biological reagents, device packaging, integrating electronics for data collection/analysis, and the requirement of external accessories and power. Many microfluidic, electronic, and biological design strategies, such as handling liquids in biosensors without pumps/valves, the application of droplet-based microfluidics, paper-based microfluidic devices, and wireless networking capabilities for data transmission, are being explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OERKE, E.-C. (2006) · The Journal of Agricultural Science · doi:10.1017/s0021859605005708 · Cited by 5,283
Surface Plasmon Resonance Sensors for Detection of Chemical and Biological Species
Homola, J. (2008) · Chemical Reviews · doi:10.1021/cr068107d · Cited by 4,525
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Top 10 plant pathogenic bacteria in molecular plant pathology
MANSFIELD, J., GENIN, S., MAGORI, S., CITOVSKY, V., SRIARIYANUM, M., RONALD, P., DOW, M., VERDIER, V., BEER, S. V., MACHADO, M. A., et al. (2012) · Molecular Plant Pathology · doi:10.1111/j.1364-3703.2012.00804.x · Cited by 2,409
Present and future of surface plasmon resonance biosensors
Homola, J. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2101-0 · Cited by 2,321
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Engineered antibody fragments and the rise of single domains
Holliger, P., & Hudson, P. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1142 · Cited by 1,931
Anderson, P. K., Cunningham, A. A., Patel, N. G., Morales, F. J., Epstein, P. R., & Daszak, P. (2004) · Trends in Ecology & Evolution · doi:10.1016/j.tree.2004.07.021 · Cited by 1,713
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
A review of advanced techniques for detecting plant diseases
Sankaran, S., Mishra, A., Ehsani, R. J., & Davis, C. E. (2010) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2010.02.007 · Cited by 1,372
Katz, E., & Willner, I. (2003) · Electroanalysis · doi:10.1002/elan.200390114 · Cited by 1,351
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Commercialization of microfluidic point-of-care diagnostic devices
Chin, C. D., Linder, V., & Sia, S. K. (2012) · Lab on a Chip · doi:10.1039/c2lc21204h · Cited by 1,124
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Dielectrophoresis: The Behavior of Neutral Matter in Nonuniform Electric Fields
Pohl, H. A. (1978) · Medical Entomology and Zoology · Cited by 935
Biosensors for detection of pathogenic bacteria
Ivnitski, D., Abdel-Hamid, I., Atanasov, P., & Wilkins, E. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00039-1 · Cited by 931
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766
Stability of peptide nucleic acids in human serum and cellular extracts
Demidov, V. V., Potaman, V. N., Frank-Kamenetskil, M. D., Egholm, M., Buchard, O., Sönnichsen, S. H., & Nlelsen, P. E. (1994) · Biochemical Pharmacology · doi:10.1016/0006-2952(94)90171-6 · Cited by 737
Garibyan, L., & Avashia, N. (2013) · Journal of Investigative Dermatology · doi:10.1038/jid.2013.1 · Cited by 689
Ganter, M. T., & Hofer, C. K. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b367 · Cited by 677
Point-of-care testing (POCT): Current techniques and future perspectives
Luppa, P. B., Müller, C., Schlichtiger, A., & Schlebusch, H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.01.019 · Cited by 660
Electrochemical nucleic acid biosensors
Wang, J. (2002) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)01399-x · Cited by 614
An Overview on Wireless Sensor Networks Technology and Evolution
Buratti, C., Conti, A., Dardari, D., & Verdone, R. (2009) · Sensors · doi:10.3390/s90906869 · Cited by 597
McDonnell, J. M. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00251-9 · Cited by 594
Pai, N. P., Vadnais, C., Denkinger, C., Engel, N., & Pai, M. (2012) · PLoS Medicine · doi:10.1371/journal.pmed.1001306 · Cited by 593
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Single virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Aptamer-based biosensors for biomedical diagnostics
Zhou, W., Jimmy Huang, P.-J., Ding, J., & Liu, J. (2014) · The Analyst · doi:10.1039/c4an00132j · Cited by 539
Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800863w · Cited by 532
Liu, G., & Lin, Y. (2006) · Analytical Chemistry · doi:10.1021/ac051559q · Cited by 478
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Zhang, C., & Xing, D. (2007) · Nucleic Acids Research · doi:10.1093/nar/gkm389 · Cited by 417
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Molecular diagnostics for fungal plant pathogens
McCartney, H. A., Foster, S. J., Fraaije, B. A., & Ward, E. (2003) · Pest Management Science · doi:10.1002/ps.575 · Cited by 401
Ultrafast microfluidics using surface acoustic waves
Yeo, L. Y., & Friend, J. R. (2009) · Biomicrofluidics · doi:10.1063/1.3056040 · Cited by 391
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
Amperometric biosensors for clinical and therapeutic drug monitoring: a review
Wang, J. (1999) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(98)00056-9 · Cited by 293
Emerging Infectious Diseases: Public Health Issues for the 21st Century
Binder, S., Levitt, A. M., Sacks, J. J., & Hughes, J. M. (1999) · Science · doi:10.1126/science.284.5418.1311 · Cited by 281
A B Cell-Based Sensor for Rapid Identification of Pathogens
Rider, T. H., Petrovick, M. S., Nargi, F. E., Harper, J. D., Schwoebel, E. D., Mathews, R. H., Blanchard, D. J., Bortolin, L. T., Young, A. M., Chen, J., et al. (2003) · Science · doi:10.1126/science.1084920 · Cited by 267
Park, S., Zhang, Y., Wang, T.-H., & Yang, S. (2011) · Lab on a Chip · doi:10.1039/c1lc20307j · Cited by 241
High-Performance Single Cell Genetic Analysis Using Microfluidic Emulsion Generator Arrays
Zeng, Y., Novak, R., Shuga, J., Smith, M. T., & Mathies, R. A. (2010) · Analytical Chemistry · doi:10.1021/ac902683t · Cited by 232
A review on viral biosensors to detect human pathogens
Caygill, R. L., Blair, G. E., & Millner, P. A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.09.038 · Cited by 230
Electroanalytical biosensors and their potential for food pathogen and toxin detection
Palchetti, I., & Mascini, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1876-4 · Cited by 223
Microfluidic diagnostics for the developing world
Mao, X., & Huang, T. J. (2012) · Lab on a Chip · doi:10.1039/c2lc90022j · Cited by 223
Yang, L., & Li, Y. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.06.024 · Cited by 221
Focus. Dealing with ‘real’ samples: sample pre-treatment in microfluidic systems
de Mello, A. J., & Beard, N. (2003) · Lab Chip · doi:10.1039/b301019h · Cited by 207
Lee, B. S., Lee, Y. U., Kim, H.-S., Kim, T.-H., Park, J., Lee, J.-G., Kim, J., Kim, H., Lee, W. G., & Cho, Y.-K. (2011) · Lab Chip · doi:10.1039/c0lc00205d · Cited by 200
Artificial neural networks in foodstuff analyses: Trends and perspectives A review
Marini, F. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.01.009 · Cited by 199
Point-of-care breath test for biomarkers of active pulmonary tuberculosis
Phillips, M., Basa-Dalay, V., Blais, J., Bothamley, G., Chaturvedi, A., Modi, K. D., Pandya, M., Natividad, M. P. R., Patel, U., Ramraje, N. N., et al. (2012) · Tuberculosis · doi:10.1016/j.tube.2012.04.002 · Cited by 190
Antimicrobial Peptides for Detection of Bacteria in Biosensor Assays
Kulagina, N. V., Lassman, M. E., Ligler, F. S., & Taitt, C. R. (2005) · Analytical Chemistry · doi:10.1021/ac050639r · Cited by 175
Adhesion based detection, sorting and enrichment of cells in microfluidic Lab-on-Chip devices
Didar, T. F., & Tabrizian, M. (2010) · Lab on a Chip · doi:10.1039/c0lc00130a · Cited by 173
Community Epidemiology Framework for Classifying Disease Threats
Fenton, A., & Pedersen, A. B. (2005) · Emerging Infectious Diseases · doi:10.3201/eid1112.050306 · Cited by 167
The Potential Impact of Droplet Microfluidics in Biology
Schneider, T., Kreutz, J., & Chiu, D. T. (2013) · Analytical Chemistry · doi:10.1021/ac400257c · Cited by 166
Rapid Detection of Mycobacterium tuberculosis by Recombinase Polymerase Amplification
Boyle, D. S., McNerney, R., Teng Low, H., Leader, B. T., Pérez-Osorio, A. C., Meyer, J. C., O'Sullivan, D. M., Brooks, D. G., Piepenburg, O., & Forrest, M. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103091 · Cited by 164 · cited 1×
“Some of the methods for isothermal amplification include loop-mediated isothermal amplification (LAMP),(69) helicase-dependent amplification (HDA),(70) nucleic acid sequence–based amplification (NASBA),(71) recombinase polymerase amplification (RPA),(72) and rolling circle amplification (RCA).(72)”
MethodUsing artificial neural networks for solving chemical problems
Smits, J. R. M., Melssen, W. J., Buydens, L. M. C., & Kateman, G. (1994) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(93)e0035-3 · Cited by 163
Status of point-of-care testing: promise, realities, and possibilities
St-Louis, P. (2000) · Clinical Biochemistry · doi:10.1016/s0009-9120(00)00138-7 · Cited by 163
Continuous dielectrophoretic cell separation microfluidic device
Li, Y., Dalton, C., Crabtree, H. J., Nilsson, G., & Kaler, K. V. I. S. (2007) · Lab Chip · doi:10.1039/b613344d · Cited by 158
Miniature magnetic resonance system for point-of-care diagnostics
Issadore, D., Min, C., Liong, M., Chung, J., Weissleder, R., & Lee, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20177h · Cited by 150
Improving Healthcare Accessibility through Point-of-Care Technologies
Edited on behalf of the National Institute of Biomedical Imaging and Bioengineering/National Heart, L., Price, C. P., & Kricka, L. J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084707 · Cited by 142
A nanobeads amplified QCM immunosensor for the detection of avian influenza virus H5N1
Li, D., Wang, J., Wang, R., Li, Y., Abi-Ghanem, D., Berghman, L. R., Hargis, B. M., & Lu, H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.010 · Cited by 138
Discovering genetic polymorphisms in next‐generation sequencing data
Imelfort, M., Duran, C., Batley, J., & Edwards, D. (2009) · Plant Biotechnology Journal · doi:10.1111/j.1467-7652.2009.00406.x · Cited by 129
A novel wireless glucose sensor employing direct electron transfer principle based enzyme fuel cell
Kakehi, N., Yamazaki, T., Tsugawa, W., & Sode, K. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.11.004 · Cited by 126
Vidal, J.-C., Espuelas, J., García-Ruiz, E., & Castillo, J. R. (2004) · Talanta · doi:10.1016/j.talanta.2004.03.038 · Cited by 124
Development of a surface plasmon resonance biosensor for the identification of Campylobacter jejuni
Wei, D. M., Oyarzábal, O. A., Huang, T., Balasubramanian, S., Sista, S. P., & Simonian, A. L. (2007) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2006.12.002 · Cited by 121
Lopez, A. D. (2005) · Globalization and Health · doi:10.1186/1744-8603-1-5 · Cited by 119
Point-of-care testing, medical error, and patient safety: a 2007 assessment
Ehrmeyer, S. S., & Laessig, R. H. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.164 · Cited by 116
Botulinum Neurotoxin Serotype a Specific Cell-Based Potency Assay to Replace the Mouse Bioassay
Fernández‐Salas, E., Wang, J., Molina, Y., Nelson, J. B., Jacky, B., & Aoki, K. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0049516 · Cited by 115
Point of care testing in the emergency department
Fermann, G. J., & Suyama, J. (2002) · Journal of Emergency Medicine · doi:10.1016/s0736-4679(02)00429-8 · Cited by 107
Acoustically Driven Programmable Microfluidics for Biological and Chemical Applications
Wixforth, A. (2006) · JALA Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2006.08.001 · Cited by 107
Chen, D., Chen, L., Tan, J., Chen, J., Du, L., Sun, T., Shen, J., Chen, K., Jiang, H., & Shen, X. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m408211200 · Cited by 106
Ding, S., Chang, B., Wu, C.-C., Lai, M.-F., & Chang, H. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.08.046 · Cited by 105
Future of portable devices for plant pathogen diagnosis
Sanati‐Nezhad, A. (2014) · Lab on a Chip · doi:10.1039/c4lc00487f · Cited by 104
Moncada-Hernández, H., & Lapizco‐Encinas, B. H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3422-4 · Cited by 101
Electrochemical impedance spectroscopy as a platform for reagentless bioaffinity sensing
Lillie, G. C., Payne, P. A., & Vadgama, P. M. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00821-8 · Cited by 100
Preechaburana, P., Suska, A., & Filippini, D. (2014) · Trends in biotechnology · doi:10.1016/j.tibtech.2014.03.007 · Cited by 94
Mens, P. F., van Amerongen, A., Sawa, P., Kager, P. A., & Schallig, H. D. F. H. (2008) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2008.03.009 · Cited by 92
Droplet microfluidics for amplification-free genetic detection of single cells
Rane, T. D., Zec, H. C., Puleo, C., Lee, A. P., & Wang, T. (2012) · Lab on a Chip · doi:10.1039/c2lc40537g · Cited by 92
Cohen-Bacrie, S., Ninove, L., Nougaırède, A., Charrel, R. N., Richet, H., Minodier, P., Badiaga, S., Noël, G., Scola, B. L., de Lamballerie, X. N., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022403 · Cited by 88
Fiber-Optic Microsphere-Based Arrays for Multiplexed Biological Warfare Agent Detection
Song, L., Ahn, S., & Walt, D. R. (2006) · Analytical Chemistry · doi:10.1021/ac051417w · Cited by 87
The Evidence to Support Point-of-Care Testing.
John, A. S. (2010) · PubMed Central · Cited by 86
Cheng, I.-F., Lin, C., Lin, D.-Y., & Chang, H. (2010) · Biomicrofluidics · doi:10.1063/1.3474638 · Cited by 85
Malic, L., Sandros, M. G., & Tabrizian, M. (2011) · Analytical Chemistry · doi:10.1021/ac200465m · Cited by 83
Point-of-care biosensor system
Vasan, A. S. S., Mahadeo, D. M., Doraiswami, R., Huang, Y., & Pecht, M. (2012) · Frontiers in Bioscience-Scholar · doi:10.2741/s357 · Cited by 83
A novel molecularly imprinted polymer thin film as biosensor for uric acid
Chen, P., Vittal, R., Nien, P., Liou, G., & Ho, K. (2009) · Talanta · doi:10.1016/j.talanta.2009.08.041 · Cited by 73
BioElectronic Tongue for the quantification of total polyphenol content in wine
Cetó, X., Céspedes, F., & del Valle, M. (2012) · Talanta · doi:10.1016/j.talanta.2012.06.031 · Cited by 72
Immunosensors in clinical analysis
Stefan, R. I., van Staden, J. F., & Aboul‐Enein, H. Y. (2000) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051560 · Cited by 69
Nanomonitor: A Miniature Electronic Biosensor for Glycan Biomarker Detection
Nagaraj, V. J., Aithal, S., Eaton, S., Bothara, M. G., Wiktor, P. J., & Prasad, S. (2010) · Nanomedicine · doi:10.2217/nnm.10.11 · Cited by 67
Biosensors for L-malate and L-lactate based on solid binding matrix
Katrlík, J., Pizzariello, A., Mastihuba, V., Švorc, J., Streďanský, M., & Miertuš, S. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00610-2 · Cited by 65
Rapid Point-Of-Care Breath Test for Biomarkers of Breast Cancer and Abnormal Mammograms
Phillips, M., Beatty, J. D., Cataneo, R. N., Huston, J., Kaplan, P. D., Lalisang, R. I., Lambin, P., Lobbes, M. B. I., Mundada, M., Pappas, N., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090226 · Cited by 63
Rapi, S., Bazzini, C., Tozzetti, C., Sbolci, V., & Modesti, P. A. (2008) · Translational research · doi:10.1016/j.trsl.2008.11.010 · Cited by 60
Chen, L., Lee, S., Lee, M., Lim, C., Choo, J., Park, J. Y., Lee, S., Joo, S., Lee, K.-H., & Choi, Y.-W. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.013 · Cited by 60
Biotoxin Detection Using Cell-Based Sensors
Banerjee, P., Kintzios, S. E., & Prabhakarpandian, B. (2013) · Toxins · doi:10.3390/toxins5122366 · Cited by 56
Bioelectric recognition assay (BERA)
Kintzios, S. E., Pistola, E., Panagiotopoulos, P., Bomsel, M., Alexandropoulos, N., Bem, F., Ekonomou, G., Biselis, J., & Levin, R. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00127-0 · Cited by 55
Dyszkiewicz-Korpanty, A. M., Olteanu, H., Frenkel, E. P., & Sarode, R. (2007) · Platelets · doi:10.1080/09537100701280654 · Cited by 54
Direct hemoglobin measurement on a centrifugal microfluidic platform for point-of-care diagnostics
Steigert, J., Grumann, M., Dube, M., Streule, W., Riegger, L., Brenner, T., Koltay, P., Mittmann, K., Zengerle, R., & Ducrée, J. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2006.01.031 · Cited by 54
Quality and timeliness in medical laboratory testing
Schimke, I. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2349-5 · Cited by 51
Prototype Amperometric Biosensor for Sialic Acid Determination
Marzouk, S. A. M., Ashraf, S. M., & Tayyari, K. A. A. (2006) · Analytical Chemistry · doi:10.1021/ac061886d · Cited by 47
Multi-analyte assay for triazines using cross-reactive antibodies and neural networks
Reder, S., Dieterle, F., Jansen, H., et al. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00202-1 · Cited by 39
Wang, H., Zhang, C., & Xing, D. (2011) · Microchimica Acta · doi:10.1007/s00604-011-0584-5 · Cited by 37
Potentiometric biosensor for studying hydroquinone cytotoxicity in vitro
Wang, Y., Chen, Q., & Zeng, X. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.027 · Cited by 36
Renard, M., Belkadi, L., & Bedouelle, H. (2003) · Journal of Molecular Biology · doi:10.1016/s0022-2836(02)01334-7 · Cited by 32
Kamboj, D. V., Goel, A. K., & Singh, L. (2006) · Defence Science Journal · doi:10.14429/dsj.56.1915 · Cited by 30
The essential role of information management in point-of-care/critical care testing
Blick, K. E. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00460-0 · Cited by 30
Point-of-Care-Testing – das Intensivlaboratorium
Müller, M. M., Hackl, W. O., & Griesmacher, A. (1999) · Der Anaesthesist · doi:10.1007/s001010050661 · Cited by 30
The use of the iSTAT portable analyzer in patients undergoing cardiopulmonary bypass
Connelly, N. R., Magee, M., & Kiessling, B. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02221752 · Cited by 27
Kintzios, S. E., Bem, F., Mangana, O., Nomikou, K., Markoulatos, P., Alexandropoulos, N., Fasseas, C., Arakelyan, V. B., Petrou, A., Soukouli, K., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.04.009 · Cited by 25
Ferentinos, K. P., Yialouris, C. P., Blouchos, P., Moschopoulou, G., & Kintzios, S. E. (2013) · BioMed Research International · doi:10.1155/2013/813519 · Cited by 21
Biosensors: Recent advances and mathematical challenges
(2014) · doi:10.3926/oms.98 · Cited by 11
Establishment of a conversion factor for the Cepheid GeneXpert BCR-ABL Assay
McNiven, M., & Talaulikar, D. (2011) · Pathology · doi:10.1097/pat.0b013e32834e4203 · Cited by 9
Cited by
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Microfluidics Based Point‐of‐Care Diagnostics
Pandey, C. M., Augustine, S., Kumar, S., Kumar, S., Nara, S., Srivastava, S., & Malhotra, B. D. (2018) · Biotechnology Journal · doi:10.1002/biot.201700047 · Cited by 273
Fundamentals of bio-electrochemical sensing
Shanbhag, M. M., Manasa, G., Mascarenhas, R. J., Mondal, K., & Shetti, N. P. (2023) · Chemical Engineering Journal Advances · doi:10.1016/j.ceja.2023.100516 · Cited by 273
Metadata
- Authors
- Srinivasan, B., & Tung, S.
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2015-08
- Volume
- 20
- Issue
- 4
- Pages
- 365-389
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2141259981
- Cited by
- 262
- References
- 115
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.