Review of control strategies for lower-limb exoskeletons to assist gait
Open accessThe DOI matches its Crossref record; 287 of the 287 references it cites were found in a registry or an index.
Abstract
Background: Many lower-limb exoskeletons have been developed to assist gait, exhibiting a large range of control methods. The goal of this paper is to review and classify these control strategies, that determine how these devices interact with the user. Methods: In addition to covering the recent publications on the control of lower-limb exoskeletons for gait assistance, an effort has been made to review the controllers independently of the hardware and implementation aspects. The common 3-level structure (high, middle, and low levels) is first used to separate the continuous behavior (mid-level) from the implementation of position/torque control (low-level) and the detection of the terrain or user’s intention (high-level). Within these levels, different approaches (functional units) have been identified and combined to describe each considered controller. Results: 291 references have been considered and sorted by the proposed classification. The methods identified in the high-level are manual user input, brain interfaces, or automatic mode detection based on the terrain or user’s movements. In the mid-level, the synchronization is most often based on manual triggers by the user, discrete events (followed by state machines or time-based progression), or continuous estimations using state variables. The desired action is determined based on position/torque profiles, model-based calculations, or other custom functions of the sensory signals. In the low-level, position or torque controllers are used to carry out the desired actions. In addition to a more detailed description of these methods, the variants of implementation within each one are also compared and discussed in the paper. Conclusions: By listing and comparing the features of the reviewed controllers, this work can help in understanding the numerous techniques found in the literature. The main identified trends are the use of pre-defined trajectories for full-mobilization and event-triggered (or adaptive-frequency-oscillator-synchronized) torque profiles for partial assistance. More recently, advanced methods to adapt the position/torque profiles online and automatically detect terrains or locomotion modes have become more common, but these are largely still limited to laboratory settings. An analysis of the possible underlying reasons of the identified trends is also carried out and opportunities for further studies are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Gladstone, D. J., Danells, C. J., & Black, S. E. (2002) · Neurorehabilitation and Neural Repair · doi:10.1177/154596802401105171 · Cited by 2,032
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Review of control strategies for robotic movement training after neurologic injury
Marchal-Crespo, L., & Reinkensmeyer, D. J. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-20 · Cited by 1,182
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
Self-citationHuman-in-the-loop optimization of exoskeleton assistance during walking
Zhang, J., Fiers, P., Witte, K. A., Jackson, R. W., Poggensee, K. L., Atkeson, C. G., & Collins, S. H. (2017) · Science · doi:10.1126/science.aal5054 · Cited by 1,011
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
Esquenazi, A., Talaty, M., Packel, A., & Saulino, M. (2012) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e318269d9a3 · Cited by 958
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Review of assistive strategies in powered lower-limb orthoses and exoskeletons
Yan, T., Cempini, M., Oddo, C. M., & Vitiello, N. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.032 · Cited by 715
A soft robotic exosuit improves walking in patients after stroke
Awad, L. N., Bae, J., O’Donnell, K., De Rossi, S. M. M., Hendron, K., Sloot, L. H., Kudzia, P., Allen, S., Holt, K. G., Ellis, T. D., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai9084 · Cited by 672
Geyer, H., & Herr, H. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047592 · Cited by 627
On the Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Kazerooni, H., Racine, J.-L., Huang, L., & Steger, R. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570790 · Cited by 594
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 508
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503
Multiple Muscle Systems: Biomechanics and Movement Organization
(1990) · Springer eBooks · doi:10.1007/978-1-4613-9030-5 · Cited by 492
Reducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
Vita, F., Taiti, C., Pompeiano, A., Gu, Z., Lo Presti, E., Whitney, L., Monti, M., Di Miceli, G., Giambalvo, D., Ruisi, P., et al. (2016) · Scientific Reports · doi:10.1038/srep34619 · Cited by 436
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
Donati, A. R. C., Shokur, S., Morya, E., Campos, D. S. F., Moioli, R. C., Gitti, C. M., Augusto, P. B., Tripodi, S., Pires, C. G., Pereira, G. A., et al. (2016) · Scientific Reports · doi:10.1038/srep30383 · Cited by 428
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Path Control: A Method for Patient-Cooperative Robot-Aided Gait Rehabilitation
Duschau-Wicke, A., von Zitzewitz, J., Caprez, A., Lunenburger, L., & Riener, R. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2033061 · Cited by 421
Intention-Based Walking Support for Paraplegia Patients with Robot Suit HAL
Suzuki, K., Mito, G., Kawamoto, H., Hasegawa, Y., & Sankai, Y. (2010) · Climbing and Walking Robots · doi:10.5772/8835 · Cited by 400
Hill-Based Muscle Models: A Systems Engineering Perspective
Winters, J. M. (1990) · Multiple Muscle Systems · doi:10.1007/978-1-4613-9030-5_5 · Cited by 386
Design and Control of the MINDWALKER Exoskeleton
Wang, S., Wang, L., Meijneke, C., van Asseldonk, E., Hoellinger, T., Cheron, G., Ivanenko, Y., La Scaleia, V., Sylos-Labini, F., Molinari, M., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2365697 · Cited by 380
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Bortole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Power Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
Preliminary Evaluation of a Powered Lower Limb Orthosis to Aid Walking in Paraplegic Individuals
Farris, R. J., Quintero, H. A., & Goldfarb, M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2163083 · Cited by 342
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Lee, S., & Sankai, Y. (2003) · IEEE/RSJ International Conference on Intelligent Robots and System · doi:10.1109/irds.2002.1043967 · Cited by 291
High-Precision Robust Force Control of a Series Elastic Actuator
Oh, S., & Kong, K. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2016.2614503 · Cited by 278
Orizio, C., Gobbo, M., Diemont, B., Esposito, F., & Veicsteinas, A. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0924-1 · Cited by 260
Grimmer, M., Riener, R., Walsh, C. J., & Seyfarth, A. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0458-8 · Cited by 249
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Sawicki, G. S., & Ferris, D. P. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-23 · Cited by 248
EEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
Mooney, L. M., & Herr, H. M. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0111-3 · Cited by 229
Robotics and Automation Handbook
(2004) · CRC Press eBooks · doi:10.1201/9781420039733 · Cited by 229
Reference Trajectory Generation for Rehabilitation Robots: Complementary Limb Motion Estimation
Vallery, H., van Asseldonk, E. H. F., Buss, M., & van der Kooij, H. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008278 · Cited by 228
The development and testing of a human machine interface for a mobile medical exoskeleton
Strausser, K. A., & Kazerooni, H. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6095025 · Cited by 226
Galle, S., Malcolm, P., Collins, S. H., & De Clercq, D. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0235-0 · Cited by 225
Brain–machine interfaces for controlling lower-limb powered robotic systems
He, Y., Eguren, D., Azorín, J. M., Grossman, R. G., Luu, T. P., & Contreras-Vidal, J. L. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa8c0 · Cited by 224
Adaptive Impedance Control of a Robotic Orthosis for Gait Rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · IEEE Transactions on Cybernetics · doi:10.1109/tsmcb.2012.2222374 · Cited by 223
Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review
Pinto-Fernandez, D., Torricelli, D., Sanchez-Villamanan, M. D. C., Aller, F., Mombaur, K., Conti, R., Vitiello, N., Moreno, J. C., & Pons, J. L. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2989481 · Cited by 220
The Effects of Body Weight Support on the Locomotor Pattern of Spastic Paretic Patients
Visintin, M., & Barbeau, H. (1989) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100029152 · Cited by 217
Powered Hip Exoskeletons Can Reduce the User's Hip and Ankle Muscle Activations During Walking
Lenzi, T., Carrozza, M. C., & Agrawal, S. K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2248749 · Cited by 215
Design and evaluation of Mina: A robotic orthosis for paraplegics
Neuhaus, P. D., Noorden, J. H., Craig, T. J., Torres, T., Kirschbaum, J., & Pratt, J. E. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975468 · Cited by 208
Jackson, R. W., & Collins, S. H. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01133.2014 · Cited by 205
(2009) · IFMBE Proceedings · doi:10.1007/978-3-540-89208-3 · Cited by 204
Development of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
Oscillator-based assistance of cyclical movements: model-based and model-free approaches
Ronsse, R., Lenzi, T., Vitiello, N., Koopman, B., van Asseldonk, E., De Rossi, S. M. M., van den Kieboom, J., van der Kooij, H., Carrozza, M. C., & Ijspeert, A. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0816-1 · Cited by 188
Self-citationA PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185
Witte, K. A., Fiers, P., Sheets-Singer, A. L., & Collins, S. H. (2020) · Science Robotics · doi:10.1126/scirobotics.aay9108 · Cited by 184
A portable powered ankle-foot orthosis for rehabilitation
Shorter, K. A., Kogler, G. F., Loth, E., Durfee, W. K., & Hsiao-Wecksler, E. T. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.04.0054 · Cited by 180
Fully autonomous hip exoskeleton saves metabolic cost of walking
Seo, K., Lee, J., Lee, Y., Ha, T., & Shim, Y. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487663 · Cited by 177
Assessment of Motion of a Swing Leg and Gait Rehabilitation With a Gravity Balancing Exoskeleton
Agrawal, S. K., Banala, S. K., Fattah, A., Sangwan, V., Krishnamoorthy, V., Scholz, J. P., & Hsu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903930 · Cited by 170
Development of the IHMC Mobility Assist Exoskeleton
Kwa, H. K., Noorden, J., Missel, M., Craig, T., Pratt, J. E., & Neuhaus, P. D. (2009) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2009.5152394 · Cited by 169
Real-Time Neural Network-Based Gait Phase Estimation Using a Robotic Hip Exoskeleton
Kang, I., Kunapuli, P., & Young, A. J. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2961749 · Cited by 168
Ao, D., Song, R., & Gao, J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2583464 · Cited by 166
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Tefertiller, C., Hays, K., Jones, J., Jayaraman, A., Hartigan, C., Bushnik, T., & Forrest, G. F. (2018) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci17-00014 · Cited by 165
Voluntary motion support control of Robot Suit HAL triggered by bioelectrical signal for hemiplegia
Kawamoto, H., Taal, S. R., Niniss, H., Hayashi, T., Kamibayashi, K., Eguchi, K., & Sankai, Y. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626191 · Cited by 164
Lerner, Z. F., Damiano, D. L., Park, H., Gravunder, A. J., & Bulea, T. C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2595501 · Cited by 164
Stauffer, Y., Allemand, Y., Bouri, M., Fournier, J., Clavel, R., Metrailler, P., Brodard, R., & Reynard, F. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008288 · Cited by 163
Self-citationAn autonomous, underactuated exoskeleton for load-carrying augmentation
Walsh, C., Pasch, K., & Herr, H. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.281932 · Cited by 162
Koller, J. R., Jacobs, D. A., Ferris, D. P., & Remy, C. D. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0086-5 · Cited by 162
Veale, A. J., & Xie, S. Q. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.01.010 · Cited by 160
EMG patterns during assisted walking in the exoskeleton
Labini, F. S., Scaleia, V. L., d’Avella, A., Pisotta, I., Tamburella, F., Scivoletto, G., Molinari, M., Wang, S., Wang, L., van Asseldonk, E. H. F., et al. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00423 · Cited by 157
Reducing the Energy Cost of Human Running Using an Unpowered Exoskeleton
Nasiri, R., Ahmadi, A., & Ahmadabadi, M. N. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2872889 · Cited by 155
Invariant hip moment pattern while walking with a robotic hip exoskeleton
Lewis, C. L., & Ferris, D. P. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.01.030 · Cited by 154
Harib, O., Hereid, A., Agrawal, A., Gurriet, T., Finet, S., Boéris, G., Duburcq, A., Mungai, M. E., Masselin, M., Ames, A. D., et al. (2018) · IEEE Control Systems · doi:10.1109/mcs.2018.2866604 · Cited by 153
Liu, M., Wang, D., & Huang, H. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2420539 · Cited by 145
Bae, J., Siviy, C., Rouleau, M., Menard, N., Odonnell, K., Geliana, I., Athanassiu, M., Ryan, D., Bibeau, C., Sloot, L., et al. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8461046 · Cited by 145
Adaptation to walking with an exoskeleton that assists ankle extension
Galle, S., Malcolm, P., Derave, W., & Clercq, D. D. (2013) · Gait & Posture · doi:10.1016/j.gaitpost.2013.01.029 · Cited by 144
A brain-controlled exoskeleton with cascaded event-related desynchronization classifiers
Lee, K., Liu, D., Perroud, L., Chavarriaga, R., & Millán, J. D. R. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.10.005 · Cited by 143
Locomotor adaptation to a powered ankle-foot orthosis depends on control method
Cain, S. M., Gordon, K. E., & Ferris, D. P. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-48 · Cited by 141
Robot assisted gait training with active leg exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762885 · Cited by 140
Estimating instantaneous energetic cost during non-steady-state gait
Selinger, J. C., & Donelan, J. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00445.2014 · Cited by 137
Durandau, G., Farina, D., Asín-Prieto, G., Dimbwadyo-Terrer, I., Lara, S. L., Pons, J. L., Moreno, J. C., & Sartori, M. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0559-z · Cited by 136
The Effect of Hip Assistance Levels on Human Energetic Cost Using Robotic Hip Exoskeletons
Kang, I., Hsu, H., & Young, A. J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2890896 · Cited by 135
Robotic lower limb exoskeletons using proportional myoelectric control
Ferris, D. P., & Lewis, C. L. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333984 · Cited by 134
The Cybathlon promotes the development of assistive technology for people with physical disabilities
Riener, R. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0157-2 · Cited by 127
Lerner, Z. F., Gasparri, G. M., Bair, M. O., Lawson, J. L., Luque, J., Harvey, T. A., & Lerner, A. T. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2870756 · Cited by 125
Delayed Output Feedback Control for Gait Assistance With a Robotic Hip Exoskeleton
Lim, B., Lee, J., Jang, J., Kim, K., Park, Y. J., Seo, K., & Shim, Y. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2913318 · Cited by 119
A wearable exoskeleton suit for motion assistance to paralysed patients
Chen, B., Zhong, C.-H., Zhao, X., Ma, H., Guan, X., Li, X., Liang, F., Cheng, J. C. Y., Qin, L., Law, S. W., et al. (2017) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2017.02.007 · Cited by 118
Shamaei, K., Cenciarini, M., Adams, A. A., Gregorczyk, K. N., Schiffman, J. M., & Dollar, A. M. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2307698 · Cited by 117
Walking assist device with bodyweight support system
Ikeuchi, Y., Ashihara, J., Hiki, Y., Kudoh, H., & Noda, T. (2009) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2009.5354543 · Cited by 116
Depth Sensing for Improved Control of Lower Limb Prostheses
Krausz, N. E., Lenzi, T., & Hargrove, L. J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2448457 · Cited by 115
IMU-based iterative control for hip extension assistance with a soft exosuit
Ding, Y., Galiana, I., Siviy, C., Panizzolo, F. A., & Walsh, C. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487530 · Cited by 115
Design and Evaluation of a Soft Assistive Lower Limb Exoskeleton
Natali, C. D., Poliero, T., Sposito, M., Graf, E. S., Bauer, C. M., Pauli, C. A., Bottenberg, E., de Eyto, A., O'Sullivan, L. W., Hidalgo, A. F., et al. (2019) · Robotica · doi:10.1017/s0263574719000067 · Cited by 115
Young, A. J., Foss, J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00004 · Cited by 113
Huo, W., Mohammed, S., Amirat, Y., & Kong, K. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2830367 · Cited by 108
Gait training using a robotic hip exoskeleton improves metabolic gait efficiency in the elderly
Martini, E., Crea, S., Parri, A., Bastiani, L., Faraguna, U., McKinney, Z., Molino-Lova, R., Pratali, L., & Vitiello, N. (2019) · Scientific Reports · doi:10.1038/s41598-019-43628-2 · Cited by 108
Impedance and Interaction Control
Hogan, N., & Buerger, S. P. (2018) · doi:10.1201/9781315220352-22 · Cited by 107
Adaptive Frequency Oscillators and Applications
Righetti, L., Buchli, J., & Ijspeert, A. J. (2009) · The Open Cybernetics & Systemics Journal · doi:10.2174/1874110x00903010064 · Cited by 105
Self-citationTowards Restoring Locomotion for Paraplegics: Realizing Dynamically Stable Walking on Exoskeletons
Gurriet, T., Finet, S., Boéris, G., Duburcq, A., Hereid, A., Harib, O., Masselin, M., Grizzle, J. W., & Ames, A. D. (2018) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2018.8460647 · Cited by 103
McCain, E. M., Dick, T. J. M., Giest, T. N., Nuckols, R. W., Lewek, M. D., Saul, K. R., & Sawicki, G. S. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0523-y · Cited by 103
Controlling negative and positive power at the ankle with a soft exosuit
Lee, S., Crea, S., Malcolm, P., Galiana, I., Asbeck, A. T., & Walsh, C. J. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487531 · Cited by 102
Actively controlled lateral gait assistance in a lower limb exoskeleton
Wang, L., Wang, S., van Asseldonk, E. H. F., & van der Kooij, H. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696467 · Cited by 101
Elastic ankle exoskeletons reduce soleus muscle force but not work in human hopping
Farris, D. J., Robertson, B., & Sawicki, G. S. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00253.2013 · Cited by 101
Lee, G., Ding, Y., Galiana, I., Karavas, N. C., Zhou, Y. M., & Walsh, C. J. (2017) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2017.8205981 · Cited by 99
Park, E. J., Akbaş, T., Eckert-Erdheim, A. M., Sloot, L. H., Nuckols, R. W., Orzel, D., Schumm, L., Ellis, T. D., Awad, L. N., & Walsh, C. J. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2989321 · Cited by 99
Adaptive Admittance Control for an Ankle Exoskeleton Using an EMG-Driven Musculoskeletal Model
Yao, S., Zhuang, Y., Li, Z., & Song, R. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00016 · Cited by 98
Admittance Shaping-Based Assistive Control of SEA-Driven Robotic Hip Exoskeleton
Zhang, T., Tran, M., & Huang, H. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2916546 · Cited by 98
A Method for the Autonomous Control of Lower Limb Exoskeletons for Persons With Paraplegia
Quintero, H. A., Farris, R. J., & Goldfarb, M. (2012) · Journal of Medical Devices · doi:10.1115/1.4007181 · Cited by 97
Design and Control of a Lower Limb Exoskeleton for Robot-Assisted Gait Training
Beyl, P., Damme, M. V., Ham, R. V., Vanderborght, B., & Lefeber, D. (2009) · Applied Bionics and Biomechanics · doi:10.1080/11762320902784393 · Cited by 97
User-Independent Intent Recognition for Lower Limb Prostheses Using Depth Sensing
Massalin, Y., Abdrakhmanova, M., & Varol, H. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2776157 · Cited by 96
Effects of Robotic Knee Exoskeleton on Human Energy Expenditure
Gams, A., Petrič, T., Debevec, T., & Babič, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2240682 · Cited by 95
A Controller for Guiding Leg Movement During Overground Walking With a Lower Limb Exoskeleton
Martínez, A., Lawson, B. E., & Goldfarb, M. T. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2017.2768035 · Cited by 92
Yu, S., Huang, T.-H., Wang, D., Lynn, B., Sayd, D., Silivanov, V., Park, Y. S., Tian, Y., & Su, H. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2931427 · Cited by 91
Integral admittance shaping: A unified framework for active exoskeleton control
Nagarajan, U., Aguirre-Ollinger, G., & Goswami, A. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.09.015 · Cited by 90
Bayón, C., Ramírez, O., Serrano, J. I., del Castillo, M. D., Moreno, Á. P.-S., Lois, J. M. B., Martínez-Caballero, I., Lara, S. L., Cifuentes, C. A., Frizera, A., et al. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2016.12.015 · Cited by 90
Autonomous hip exoskeleton saves metabolic cost of walking uphill
Seo, K., Lee, J., & Park, Y. J. (2017) · 2017 International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2017.8009254 · Cited by 90
Siviy, C., Bae, J., Baker, L. M., Porciuncula, F., Baker, T. C., Ellis, T. D., Awad, L. N., & Walsh, C. J. (2020) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2020.2965072 · Cited by 90
Nuckols, R. W., Dick, T. J. M., Beck, O. N., & Sawicki, G. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-60360-4 · Cited by 90
Khazoom, C., Veronneau, C., Bigué, J.-P. L., Grenier, J., Girard, A., & Plante, J. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2924852 · Cited by 89
Vision-Assisted Autonomous Lower-Limb Exoskeleton Robot
Liu, D.-X., Xu, J. L., Chen, C., Long, X., Tao, D., & Wu, X. (2019) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2019.2932892 · Cited by 88
Weiler, D. T., Villajuan, S. O., Edkins, L., Cleary, S., & Saleem, J. J. (2017) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213601804 · Cited by 87
Martínez, A., Lawson, B. E., Durrough, C. M., & Goldfarb, M. T. (2018) · IEEE Transactions on Robotics · doi:10.1109/tro.2018.2883819 · Cited by 87
Gait mode recognition and control for a portable-powered ankle-foot orthosis
Li, Y. D., & Hsiao-Wecksler, E. T. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650373 · Cited by 86
Young, A. J., Gannon, H., & Ferris, D. P. (2017) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2017.00037 · Cited by 86
Wu, A. R., Dzeladini, F., Brug, T. J. H., Tamburella, F., Tagliamonte, N. L., van Asseldonk, E. H. F., van der Kooij, H., & Ijspeert, A. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00030 · Cited by 85
Self-citationReal-Time Hybrid Locomotion Mode Recognition for Lower Limb Wearable Robots
Parri, A., Yuan, K., Marconi, D., Yan, T., Crea, S., Munih, M., Lova, R. M., Vitiello, N., & Wang, Q. (2017) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2017.2755048 · Cited by 85
Control of a robotic orthosis for gait rehabilitation
Hussain, S., Xie, S. Q., & Jamwal, P. K. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.01.007 · Cited by 84
Human-Cooperative Control of a Wearable Walking Exoskeleton for Enhancing Climbing Stair Activities
Li, Z., Deng, C., & Zhao, K. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2914573 · Cited by 84
Toward Design of an Environment-Aware Adaptive Locomotion-Mode-Recognition System
Du, L., Zhang, F., Liu, M., & Huang, H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208641 · Cited by 83
Liu, X., & Wang, Q. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.2990668 · Cited by 83
Sawicki, G. S., Domingo, A., & Ferris, D. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-3 · Cited by 81
Design of a minimally constraining, passively supported gait training exoskeleton: ALEX II
Winfree, K. N., Stegall, P., & Agrawal, S. K. (2011) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975499 · Cited by 81
The Accuracy of Heart Rate Monitoring by Some Wrist-Worn Activity Trackers
Cadmus-Bertram, L., Gangnon, R., Wirkus, E. J., Thraen-Borowski, K. M., & Gorzelitz-Liebhauser, J. (2017) · Annals of Internal Medicine · doi:10.7326/l16-0353 · Cited by 80
Zhuang, Y., Yao, S.-W., Ma, C., & Song, R. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2875729 · Cited by 80
Energetics of Walking With a Robotic Knee Exoskeleton
MacLean, M. K., & Ferris, D. P. (2019) · Journal of Applied Biomechanics · doi:10.1123/jab.2018-0384 · Cited by 80
Qiu, S., Guo, W. P., Caldwell, D. G., & Chen, F. (2020) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.2968845 · Cited by 77
Tele-Impedance based stiffness and motion augmentation for a knee exoskeleton device
Karavas, N. C., Ajoudani, A., Tsagarakis, N. G., Saglia, J. A., Bicchi, A., & Caldwell, D. G. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6630872 · Cited by 75
Connecting the legs with a spring improves human running economy
Simpson, C. S., Welker, C. G., Uhlrich, S. D., Sketch, S. M., Jackson, R. W., Delp, S. L., Collins, S. H., Selinger, J. C., & Hawkes, E. W. (2019) · Journal of Experimental Biology · doi:10.1242/jeb.202895 · Cited by 75
Gagnon, D. H., Escalona, M. J., Vermette, M., Carvalho, L. P., Karelis, A. D., Duclos, C., & Aubertin‐Leheudre, M. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0354-2 · Cited by 74
Medial Gastrocnemius Myoelectric Control of a Robotic Ankle Exoskeleton
Kinnaird, C. R., & Ferris, D. P. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008285 · Cited by 73
An intrinsically compliant robotic orthosis for treadmill training
Hussain, S., Xie, S. Q., Jamwal, P. K., & Parsons, J. G. M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.003 · Cited by 72
Adaptive Oscillator-Based Robust Control for Flexible Hip Assistive Exoskeleton
Xue, T., Wang, Z., Zhang, T., & Zhang, M. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2926678 · Cited by 72
Online gait task recognition algorithm for hip exoskeleton
Jang, J., Kim, K., Lee, J., Lim, B., & Shim, Y. (2015) · 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7354129 · Cited by 71
Evaluation of Lower Leg Muscle Activities During Human Walking Assisted by an Ankle Exoskeleton
Wang, W., Chen, J., Ji, Y., Jin, W., Liu, J., & Zhang, J. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2974232 · Cited by 71
Gait Adaptation Using a Cable-Driven Active Leg Exoskeleton (C-ALEX) With Post-Stroke Participants
Hidayah, R., Bishop, L., Jin, X. H., Chamarthy, S., Stein, J. M., & Agrawal, S. K. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3009317 · Cited by 71
Adaptive assist-as-needed controller to improve gait symmetry in robot-assisted gait training
Zanotto, D., Stegall, P., & Agrawal, S. K. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6906934 · Cited by 70
Boehler, A., Hollander, K. W., Sugar, T. G., & Shin, D. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543504 · Cited by 70
Schrade, S. O., Dätwyler, K., Stücheli, M., Studer, K., Türk, D.-A., Meboldt, M., Gassert, R., & Lambercy, O. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0360-4 · Cited by 70
Recognition of walking environments and gait period by surface electromyography
Kyeong, S., Shin, W., Yang, M., Heo, U., Feng, J.-R., & Kim, J. (2019) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/fitee.1800601 · Cited by 68
A new adaptive frequency oscillator for gait assistance
Seo, K., Hyung, S., Choi, B. K., Lee, Y., & Shim, Y. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139977 · Cited by 68
Lee, J., Seo, K., Lim, B., Jang, J., Kim, K., & Choi, H. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009297 · Cited by 68
Synergy-Based Control of Assistive Lower-Limb Exoskeletons by Skill Transfer
Wei, Q., Li, Z., Zhao, K., Kang, Y., & Su, C. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2961567 · Cited by 68
Processing Surface EMG Signals for Exoskeleton Motion Control
Yin, G., Zhang, X., Chen, D., Li, H., Chen, J., Chen, C., & Lemos, S. E. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00040 · Cited by 68
Design and development of a lightweight ankle exoskeleton for human walking augmentation
Bougrinat, Y., Achiche, S., & Raison, M. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.102297 · Cited by 67
Design and control of a robotic lower extremity exoskeleton for gait rehabilitation
Unluhisarcikli, O., Pietrusinski, M., Weinberg, B., Bonato, P., & Mavroidis, C. (2011) · 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2011.6094973 · Cited by 66
Limit Cycles to Enhance Human Performance Based on Phase Oscillators
Sugar, T. G., Bates, A. R., Holgate, M. A., Kerestes, J., Mignolet, M. P., New, P., Ramachandran, R. K., Redkar, S., & Wheeler, C. (2014) · Journal of Mechanisms and Robotics · doi:10.1115/1.4029336 · Cited by 65
Laschowski, B., McNally, W., Wong, A. K. C., & McPhee, J. (2019) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2019.8779540 · Cited by 65
Development of real-time gait phase detection system for a lower extremity exoskeleton robot
Lim, D.-H., Kim, W., Kim, H.-J., & Han, C.-S. (2017) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-017-0081-9 · Cited by 60
Stepping Forward with Exoskeletons: Team IHMC?s Design and Approach in the 2016 Cybathlon
Griffin, R., Cobb, T., Craig, T., Daniel, M., van Dijk, N., Gines, J., Kramer, K., Shah, S., Siebinga, O., Smith, J., et al. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2754284 · Cited by 59
TWIICE — A lightweight lower-limb exoskeleton for complete paraplegics
Vouga, T., Baud, R., Fasola, J., Bouri, M., & Bleuler, H. (2017) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2017.8009483 · Cited by 58
Self-citationFeasibility of an optimal EMG-driven adaptive impedance control applied to an active knee orthosis
Peña, G. G., Consoni, L. J., dos Santos, W. M., & Siqueira, A. A. G. (2018) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2018.11.011 · Cited by 58
Garate, V. R., Parri, A., Yan, T., Munih, M., Lova, R. M., Vitiello, N., & Ronsse, R. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2015.2510778 · Cited by 57
Electromyography-Driven Progressive Assist-as-Needed Control for Lower Limb Exoskeleton
Gui, K., Tan, U.-X., Liu, H.-H., & Zhang, D.-G. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2970222 · Cited by 55
Preliminary design of a terrain recognition system
Zhang, F., Fang, Z., Liu, M., & Huang, H. (2011) · 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2011.6091391 · Cited by 54
Guo, B., Jianhai, H., Li, X., & Lin, Y. D. (2019) · International Journal of Advanced Robotic Systems · doi:10.1177/1729881419839584 · Cited by 54
Zhou, B., Wang, H., Hu, F., Feng, N., Xi, H., Zhang, Z., & Tang, H. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105486 · Cited by 54
Chen, B., Zhong, C.-H., Zhao, X., Ma, H., Qin, L., & Liao, W. (2019) · IEEE Access · doi:10.1109/access.2019.2904296 · Cited by 53
Towards Online Estimation of Human Joint Muscular Torque with a Lower Limb Exoskeleton Robot
Li, M., Deng, J., Zha, F., Qiu, S., Wang, X., & Chen, F. (2018) · Applied Sciences · doi:10.3390/app8091610 · Cited by 52
Stroke Survivors' Gait Adaptations to a Powered Ankle–Foot Orthosis
Ward, J. A., Sugar, T. G., Boehler, A., Standeven, J., & Engsberg, J. R. (2011) · Advanced Robotics · doi:10.1163/016918611x588907 · Cited by 51
ALEX III: A novel robotic platform with 12 DOFs for human gait training
Zanotto, D., Stegall, P., & Agrawal, S. K. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631128 · Cited by 51
Driving Robotic Exoskeletons Using Cable-Based Transmissions: A Qualitative Analysis and Overview
Grosu, S., Rijcke, L. D., Grosu, V., Geeroms, J., Vanderboght, B., Lefeber, D., & Rodriguez‐Guerrero, C. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4042399 · Cited by 50
Tamburella, F., Tagliamonte, N. L., Pisotta, I., Masciullo, M., Arquilla, M., van Asseldonk, E. H. F., van der Kooij, H., Wu, A. R., Dzeladini, F., Ijspeert, A. J., et al. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2984790 · Cited by 50
Self-citationKnee Exoskeleton Assistive Torque Control Based on Real-Time Gait Event Detection
Xu, D., Liu, X., & Wang, Q. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2930352 · Cited by 49
Lee, D., Kwak, E. C., McLain, B. J., Kang, I., & Young, A. J. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2972323 · Cited by 49
Human Preference-Based Learning for High-dimensional Optimization of Exoskeleton Walking Gaits
Tucker, M., Cheng, M., Novoseller, E., Cheng, R., Yue, Y., Burdick, J. W., & Ames, A. D. (2020) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros45743.2020.9341416 · Cited by 49
WalkON Suit: A Medalist in the Powered Exoskeleton Race of Cybathlon 2016
Choi, J., Na, B., Jung, P.-G., Rha, D., & Kong, K. (2017) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2017.2752285 · Cited by 47
Knee Impedance Modulation to Control an Active Orthosis Using Insole Sensors
Villa-Parra, A. C., Delisle-Rodríguez, D., Lima, J. P. S., Frizera, A., & Bastos-Filho, T. (2017) · Sensors · doi:10.3390/s17122751 · Cited by 47
Ankle-Foot-Orthosis Control in Inclinations and Stairs
Svensson, W., & Holmberg, U. (2008) · IEEE Conference on Robotics, Automation and Mechatronics (RAM) · doi:10.1109/ramech.2008.4681479 · Cited by 46
Dynamic Balance Gait for Walking Assistance Exoskeleton
Chen, Q., Cheng, H., Yue, C., Huang, R., & Guo, H. (2018) · Applied Bionics and Biomechanics · doi:10.1155/2018/7847014 · Cited by 45
Villa-Parra, A. C., Delisle-Rodríguez, D., Botelho, T. R., Mayor, J. J. V., López-Delis, A., Carelli, R. O., Frizera, A., & Bastos-Filho, T. (2018) · Research on Biomedical Engineering · doi:10.1590/2446-4740.07417 · Cited by 45
Development and testing of a passive Walking Assist Exoskeleton
Lovrenovic, Z., & Doumit, M. (2019) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2019.01.002 · Cited by 45
Cardona, M., & García, C. (2019) · IEEE Access · doi:10.1109/access.2019.2927515 · Cited by 45
Human-robot interaction tests on a novel robot for gait assistance
Tagliamonte, N. L., Sergi, F., Carpino, G., Accoto, D., & Guglielmelli, E. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650387 · Cited by 44
An assist-as-needed control scheme for robot-assisted rehabilitation
Asl, H. J., Narikiyo, T., & Kawanishi, M. (2017) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2017.7962953 · Cited by 44
Cardona, M., García, C., Serrano, F. E., & Saltaren, R. J. (2020) · Sensors · doi:10.3390/s20030789 · Cited by 43
Evaluating Immediate Benefits of Assisting Knee Extension With a Soft Inflatable Exosuit
Sridar, S., Qiao, Z., Rascon, A., Biemond, A., Beltran, A., Maruyama, T., Kwasnica, C. M., Polygerinos, P., & Zhang, W. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.2988305 · Cited by 43
Development of pneumatic lower limb power assist wear driven with wearable air supply system
SASAKI, D., Noritsugu, T., & TAKAIWA, M. (2013) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2013.6696994 · Cited by 42
Exoskeleton robot control based on cane and body joint synergies
Hassan, M., Kadone, H., Suzuki, K., & Sankai, Y. (2012) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2012.6386248 · Cited by 42
Torque Control in Legged Locomotion
Zhang, J., Cheah, C., & Collins, S. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803766-9.00007-5 · Cited by 42
An Ankle Exoskeleton Using a Lightweight Motor to Create High Power Assistance for Push-Off
Liu, J., Xiong, C., & Fu, C. (2019) · Journal of Mechanisms and Robotics · doi:10.1115/1.4043456 · Cited by 42
Adaptive Assist-as-needed Control Based on Actor-Critic Reinforcement Learning
Zhang, Y., Li, S., Nolan, K. J., & Zanotto, D. (2019) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros40897.2019.8968464 · Cited by 42
A biarticular passive exosuit to support balance control can reduce metabolic cost of walking
Barazesh, H., & Sharbafi, M. A. (2020) · Bioinspiration & Biomimetics · doi:10.1088/1748-3190/ab70ed · Cited by 42
Gao, S., Wang, Y., Fang, C., & Xu, L. (2020) · Applied Sciences · doi:10.3390/app10082638 · Cited by 41
A gait rehabilitation strategy inspired by an iterative learning algorithm
Bae, J., & Tomizuka, M. (2012) · Mechatronics · doi:10.1016/j.mechatronics.2012.01.009 · Cited by 40
Cited by
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Interactive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“Several reviews have also been published on LLERs [9], [37], [38], [39], [40], [41], [42].”
BackgroundDeep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
Ren, J., Wang, A., Li, H., Yue, X., & Meng, L. (2023) · Sensors · doi:10.3390/s23146547 · Cited by 34
“While significant progress has been made in exoskeleton technology [6–8], the optimization of human–robot collaboration remains a persistent challenge due to the intricate interactions between the wearers and the exoskeletons [9].”
BackgroundHuman Gait phases recognition based on multi-source data fusion and BILSTM attention neural network
Zhan, H., Kou, J., Cao, Y., Guo, Q., Zhang, J., & Shi, Y. (2024) · Measurement · doi:10.1016/j.measurement.2024.115396 · Cited by 28
Metadata
- Authors
- Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2021-07-27
- Volume
- 18
- Issue
- 1
- Pages
- 119-119
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W3183839786
- Cited by
- 381
- References
- 287
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.