Biological reactions to wear debris in total joint replacement
The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Abstract
The vast majority of total hip prostheses currently implanted consist of a hard metal or ceramic femoral head articulating against an ultra-high molecular weight polyethylene (UHMWPE) acetabular cup. Over the last 10 years, evidence has accumulated to show that these prostheses are prone to failure due to late aseptic loosening and few survive beyond 25 years. With an increasing need to implant hip prostheses in the younger, more active patient the need to understand the mechanisms of failure and to develop artificial hip joints using alternative materials have become major issues in the orthopaedic community. This review focuses initially on our current understanding of the biological reactions to UHMWPE prosthetic wear debris in vivo and in vitro since this is believed to be the main cause of late aseptic loosening. While the precise mechanisms of osteolysis induced by UHMWPE wear debris have not been elucidated, the major message to emerge is that it is not the wear volume that determines the biological response to the debris, but the concentration of the wear volume that is within the critical size range (0.2-0.8 μm) for macrophage activation. The review then considers whether the problem of wear-debris-induced osteolysis may be overcome with the use of new generation metal-on-metal or ceramic-on-ceramic prostheses. For metal-on-metal prostheses, the prospects for increasing the osteolysis free life of the implant are good but additional biological problems associated with the nanometre size and reactivity of the wear particles in vivo may emerge. For the ceramic-on-ceramic prostheses, although initial prospects are encouraging, more data are needed on the characteristics of the wear particles generated in vivo before predictions can be made. It is concluded that the pre-clinical testing of any new materials for joint replacement must include an analysis of the wear particle characteristics and their biological reactivity in addition to the usual assessment of wear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertolini, D. R., Nedwin, G. E., Bringman, T. S., Smith, D. D., & Mundy, G. R. (1986) · Nature · doi:10.1038/319516a0 · Cited by 1,434
Effect of femoral head size on wear of the polyethylene acetabular component.
Livermore, J., Ilstrup, D., & Morrey, B. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00008 · Cited by 1,024
An interleukin 1 like factor stimulates bone resorption in vitro
Gowen, M., Wood, D. D., Ihrie, E. J., McGuire, M. K. B., & Russell, R. G. G. (1983) · Nature · doi:10.1038/306378a0 · Cited by 1,012
Schmalzried, T. P., Jasty, M., & Harris, W. H. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00006 · Cited by 989
Goldring, S. R., Schiller, A. L., Roelke, M., Rourke, C. M., OʼNeil, D. A., & Harris, W. H. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365050-00001 · Cited by 849
Reactions of the articular capsule to wear products of artificial joint prostheses
Willert, H. ‐., & Semlitsch, M. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110202 · Cited by 822
Mechanism and Clinical Significance of Wear Debris-Induced Osteolysis
AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00003 · Cited by 670
Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses
Ryd, L., Albrektsson, B., Carlsson, L., Dansgard, F., Herberts, P., Lindstrand, A., Regner, L., & Toksvig-Larsen, S. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b3.7744919 · Cited by 603
Green, T. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00140-9 · Cited by 569
Widespread dissemination of metal debris from implants
Case, C., Langkamer, V., James, C., Palmer, M., Kemp, A., Heap, P., & Solomon, L. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b5.8083255 · Cited by 444
Extensive localized bone resorption in the femur following total hip replacement
Harris, W., Schiller, A., Scholler, J., Freiberg, R., & Scott, R. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658050-00005 · Cited by 438
Jiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436
Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., & Amstutz, H. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1<103::aid-jbm13>3.0.co;2-m · Cited by 431
Macrophage/particle interactions: Effect of size, composition and surface area
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280111 · Cited by 410
Macrophages stimulate bone resorption when they phagocytose particles
Murray, D., & Rushton, N. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246303 · Cited by 402
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., & Amstutz, H. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1<103::aid-jbm13>3.3.co;2-d · Cited by 377
Endosteal erosion in association with stable uncemented femoral components.
Maloney, W. J., Jasty, M., Harris, W. H., Galante, J. O., & Callaghan, J. J. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072070-00011 · Cited by 369
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352
Localized osteolysis in stable, non-septic total hip replacement.
Jasty, M. J., Floyd, W. E., Schiller, A. L., Goldring, S. R., & Harris, W. H. (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668060-00014 · Cited by 326
Anthony, P., Gie, G., Howie, C., & Ling, R. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246300 · Cited by 319
Aggressive granulomatous lesions associated with hip arthroplasty. Immunopathological studies.
Santavirta, S., Konttinen, Y. T., Bergroth, V, Eskola, A., Tallroth, K., & Lindholm, T. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072020-00014 · Cited by 318
Bone resorption activity of particulate-stimulated macrophages
Glant, T. T., Jacobs, J. J., Molnár, G., Shanbhag, A. S., Valyon, M., & Galante, J. O. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650080907 · Cited by 309
Maloney, W. J., Smith, R. L., Schmalzried, T. P., Chiba, J., Huene, D., & Rubash, H. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199509000-00002 · Cited by 307
Jacobs, J. J., Skipor, A. K., Black, J., Urban, R. M., & Galante, J. O. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173100-00005 · Cited by 306
Bone lysis in well-fixed cemented femoral components
Maloney, W., Jasty, M., Rosenberg, A., & Harris, W. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246299 · Cited by 304
The Pathology of Failed Total Joint Arthroplasty
MIRRA, J. M., MARDER, R. A., & AMSTUTZ, H. C. (1982) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198210000-00023 · Cited by 296
Biology and Physiology of the Osteoclast
Rifkin, B. R. (1992) · Cited by 289
Isolation and characterization of debris in membranes around total joint prostheses.
Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A., & Merritt, K. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199411000-00010 · Cited by 270
Human monocyte response to particulate biomaterials generated in vivo and in vitro
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130520 · Cited by 252
CYTOKINE GENE POLYMORPHISM AND HEART TRANSPLANT REJECTION1
Turner, D., Grant, S. C. D., Yonan, N., Sheldon, S., Dyer, P. A., Sinnott, P. J., & Hutchinson, I. V. (1997) · Transplantation · doi:10.1097/00007890-199709150-00021 · Cited by 243
Aggressive granulomatous lesions in cementless total hip arthroplasty
Santavirta, S., Hoikka, V, Eskola, A., Konttinen, Y., Paavilainen, T., & Tallroth, K. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246301 · Cited by 241
Effects of metal ions on osteoblast-like cell metabolism and differentiation
Sun, Z. L., Wataha, J. C., & Hanks, C. T. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199701)34:1<29::aid-jbm5>3.0.co;2-p · Cited by 230
CHIBA, J., RUBASH, H. E., JUNG, K., & IWAKI, Y. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199403000-00043 · Cited by 227
The incidence of cancer following total hip replacement
Gillespie, W., Frampton, C., Henderson, R., & Ryan, P. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b4.3403594 · Cited by 222
Brinkman, B. M., Huizinga, T. W., Kurban, S. S., van der Velde, E. A., Schreuder, G. M., Hazes, J. M., Breedveld, F. C., & Verweij, C. L. (1997) · Rheumatology · doi:10.1093/rheumatology/36.5.516 · Cited by 213
Biological reaction to debris in relation to joint prostheses
Revell, P. A., AL-Saffar, N., & Kobayashi, A. (1997) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411971534304 · Cited by 195
Fibroblast response to metallic debris in vitro. Enzyme induction cell proliferation, and toxicity.
Maloney, W. J., Smith, R. L., Castro, F., & Schurman, D. J. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00005 · Cited by 192
Glant, T. T., & Jacobs, J. J. (1994) · Journal of Orthopaedic Research · doi:10.1002/jor.1100120515 · Cited by 190
Black, J., Sherk, H., Bonini, J., Rostoker, W. R., Schajowicz, F., & Galante, J. O. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072010-00021 · Cited by 187
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
Lee, J., Salvati, E., Betts, F., DiCarlo, E., Doty, S., & Bullough, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b3.1587882 · Cited by 176
PERIPROSTHETIC BONE RESORPTION: PARTICLES VERSUS MOVEMENT
Aspenberg, P., & Herbertsson, P. (1996) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.78b4.0780641 · Cited by 173
Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces*
YOON, T. R., ROWE, S. M., JUNG, S. T., SEON, K. J., & MALONEY, W. J. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199810000-00007 · Cited by 169
Metal Versus Polyethylene Wear Particles in Total Hip Replacements: A Review
Doorn, P. F., CAMPBELL, P. A., & Amstutz, H. C. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199608001-00018 · Cited by 167
IN VITRO HUMAN MONOCYTE RESPONSE TO WEAR PARTICLES OF TITANIUM ALLOY CONTAINING VANADIUM OR NIOBIUM
Rogers, S. D., Howie, D. W., Graves, S. E., Pearcy, M. J., & Haynes, D. R. (1997) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.79b2.0790311 · Cited by 161
Metal wear and tissue response in failed titanium alloy total hip replacements
Witt, J., & Swann, M. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b4.2071635 · Cited by 161
Kadoya, Y., Revell, P. A., Al‐Saffar, N., Kobayashi, A., Scott, G., & Freeman, M. A. R. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140318 · Cited by 159
Tissue response in relation to type of wear particles around failed hip arthroplasties
Howie, D. W. (1990) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(08)80093-9 · Cited by 150
Resorption of bone by inflammatory cells derived from the joint capsule of hip arthroplasties
Athanasou, N., Quinn, J., & Bulstrode, C. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b1.1732267 · Cited by 147
Size and shape of biomaterial wear debris
Savio, J. A., Overcamp, L. M., & Black, J. (1994) · Clinical Materials · doi:10.1016/0267-6605(94)90076-0 · Cited by 144
The Response to Particulate Debris
Howie, D. W., Rogers, S. D., McGee, M. A., Pearcy, M. J., & Haynes, D. R. (1993) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)31836-8 · Cited by 140
Periprosthetic bone resorption. Particles versus movement.
Aspenberg, P., & Herbertsson, P. (1996) · PubMed · Cited by 138
CANCER RISK AFTER MCKEE-FARRAR TOTAL HIP REPLACEMENT
Visuri, T. I., & Koskenvuo, M. J. (1991) · Orthopedics · doi:10.3928/0147-7447-19910201-07 · Cited by 136
The Microscopic Anatomy of the Bone-Cement Interface in Failed Total Hip Arthroplasties
Johanson, N. A., Bullough, P. G., WILSON, P. D., Salvati, E. A., & Ranawat, C. S. (1987) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198705000-00018 · Cited by 126
Histologic investigations on 33 retrieved Nobelpharma implants
Albrektsson, T. O., Eriksson, A. R., Friberg, B., Lekholm, U., Lindahl, L., Nevins, M. L., Oikarinen, V. J., Roos, J., Sennerby, L., & Åstrand, P. (1993) · Clinical Materials · doi:10.1016/0267-6605(93)90021-x · Cited by 116
Pineda, L. M., B�sing, M., Meinig, R. P., & Gogolewski, S. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199607)31:3<421::aid-jbm17>3.0.co;2-l · Cited by 106
Goodman, S. B., Fornasier, V. L., Lee, J., & Kei, J. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240408 · Cited by 105
Jd, B., Jj, J., Tänzer, M., Urban, R. M., Aribindi, R., Sumner, D. R., Tm, T., & Brooks, C. E. (1995) · PubMed · Cited by 103
HICKS, D. G., JUDKINS, A. R., SICKEL, J. Z., ROSIER, R. N., PUZAS, J. E., & OʼKEEFE, R. J. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199604000-00002 · Cited by 98
Effects of polyethylene on macrophages
Horowitz, S. M., & Gonzales, J. B. (1997) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100150108 · Cited by 96
Macrophage phagocytosis of polyethylene particulate in vitro
Voronov, I., Santerre, J. P., Hinek, A., Callahan, J. W., Sandhu, J. K., & Boynton, E. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199801)39:1<40::aid-jbm6>3.0.co;2-i · Cited by 91
Lorenzo, J., Sousa, S., Fonseca, J., Hock, J. M., & Medlock, E. S. (1987) · Journal of Clinical Investigation · doi:10.1172/jci113042 · Cited by 91
Blaine, T. A., Pollice, P. F., Rosier, R. N., Reynolds, P. R., Puzas, J. E., & O’Keefe, R. J. (1997) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199710000-00009 · Cited by 88
Goodman, S. B., Aspenberg, P., Song, Y., Knoblich, G., Huie, P., Regula, D. P., & Lidgren, L. (1995) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199507000-00008 · Cited by 87
Role of tumor necrosis factor alpha in particulate‐induced bone resorption
Algan, S. M., Purdon, M., & Horowitz, S. M. (1996) · Journal of Orthopaedic Research · doi:10.1002/jor.1100140107 · Cited by 86
Biological, material and mechanical considerations of joint replacement
Stone, M. H. (1994) · Current Orthopaedics · doi:10.1016/0268-0890(94)90042-6 · Cited by 78
金, 強. (1993) · Medical Entomology and Zoology · doi:10.11501/3097116 · Cited by 77
Cellular events in the mechanisms of prosthesis loosening
Pizzoferrato, A., Ciapetti, G., Stea, S., & Toni, A. (1991) · Clinical Materials · doi:10.1016/0267-6605(91)90057-m · Cited by 72
Pathologic Studies of Total Joint Replacement
Bullough, P. G., DiCarlo, E. F., Hansraj, K. K., & Neves, M. C. (1988) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)32267-7 · Cited by 70
Al-Saffar, N., Mah, J. T., Kadoya, Y., & Revell, P. A. (1995) · Annals of the Rheumatic Diseases · doi:10.1136/ard.54.3.201 · Cited by 65
Al-Saffar, N., Khwaja, H. A., Kadoya, Y., & Revell, P. A. (1996) · American Journal of Clinical Pathology · doi:10.1093/ajcp/105.5.628 · Cited by 64
Morais, S., Sousa, J. P., Fernandes, M. H., & de Carvalho, G. S. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00149-x · Cited by 61
Sabokbar, A., & Rushton, N. (1995) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(05)80080-4 · Cited by 57
Regional dissemination of wear debris from a total knee prosthesis. A case report.
Bauer, T. W., Saltarelli, M. G., McMahon, J. T., & Wilde, A. H. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199301000-00013 · Cited by 48
Klein, C. L., Nieder, P., Wagner, M., K�hler, H., Bittinger, F., Kirkpatrick, C. J., & Lewis, J. C. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00213138 · Cited by 47
Shea, K. G., Bloebaum, R. D., Avent, J., BIRK, G. T., & Samuelson, K. M. (1996) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199604000-00003 · Cited by 42
Effects of stem cell factor on osteoclast-like cell formation in long-term human marrow cultures
Demulder, A., Suggs, S. V., Zsebo, K. M., Scarcez, T., & Roodman, G. D. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650071114 · Cited by 39
Inguinal lymphadenopathy due to metal release from a prosthesis. A case report
Shinto, Y., Uchida, A., Yoshikawa, H., Araki, N., Kato, T., & Ono, K. (1993) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.75b2.8444948 · Cited by 39
Wroblewski, B. M. (1997) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411971534737 · Cited by 26
Al-Saffar, N., Kadoya, Y., & Revell, P. A. (1994) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00213140 · Cited by 19
Tomás, H., de Carvalho, G. S., Fernandes, M. H., Freire, A. P., & Abrantes, L. M. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00058569 · Cited by 17
Nagase, M., Nishiya, H., & Takeuchi, H. (1995) · Scandinavian Journal of Rheumatology · doi:10.3109/03009749509099293 · Cited by 11
Cited by
The potential environmental impact of engineered nanomaterials
Colvin, V. L. (2003) · Nature Biotechnology · doi:10.1038/nbt875 · Cited by 2,158
A review of polyvinyl alcohol and its uses in cartilage and orthopedic applications
Baker, M. I., Walsh, S. P., Schwartz, Z., & Boyan, B. D. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.32694 · Cited by 1,111
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Paital, S. R., & Dahotre, N. B. (2009) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2009.05.001 · Cited by 673
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Self-citation
Metadata
- Authors
- Ingham, E., & Fisher, J.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Publisher
- SAGE Publications
- Published
- 2000-01-01
- Volume
- 214
- Issue
- 1
- Pages
- 21-37
- ISSN
- 0954-4119 (ISSN-L)
- 2041-3033
- OpenAlex
- W2068645319
- Cited by
- 708
- References
- 83
- FWCI
- 26.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.