Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 901–1,000 of 1,000
Razura-Carmona, F. F., Navidad-Murrieta, M. S., Casas-Rodríguez, J. O., Barajas-Carrillo, V. W., Covantes‐Rosales, C. E., Ojeda-Durán, A. J., Díaz‐Reséndiz, K. J. G., Toledo‐Ibarra, G. A., Ventura‐Ramón, G. H., & Girón‐Pérez, M. I. (2023) · Revista Bio Ciencias · doi:10.15741/revbio.10.e1412
Temperature fields visualization monitoring subsystem at low temperatures
Zhuravlev, A., & Annenkova, N. (2023) · AIP conference proceedings · doi:10.1063/5.0124931
Bonnefoy, A. R., & Durán-Vargas, A. (2022) · Cuadernos del Centro de Estudios de Diseño y Comunicación · doi:10.18682/cdc.vi164.7014
Fundamentals of IEQ and Occupant Needs
Schweiker, M., Berger, C., Day, J., & Mahdavi, A. (2023) · Routledge eBooks · doi:10.1201/9781003176985-2
Otsuka, M., Perusquía-Hernández, M., Isoyama, N., Uchiyama, H., & Kiyokawa, K. (2023) · IEEE Conference on Virtual Reality and 3D User Interfaces Abstracts and Workshops (VRW) · doi:10.1109/vrw58643.2023.00153
Adverse effects of the long-term use of an N95 mask in healthcare workersPreprint
Takami, H., Mitsuhashi, T., Nomura, T., Sugita, M., & Usuda, D. (2023) · Research Square · doi:10.21203/rs.3.rs-2859844/v1
Microclimate algorithmic control support on transport infrastructure inhabited objects
Zhuravlev, A., Pautov, E., Rodionova, A., Nikolskiy, S., & Annekova, N. (2023) · AIP conference proceedings · doi:10.1063/5.0102926
Real-Time Model Predictive Control of Energy Recovery Ventilators for School BuildingsPreprint
Jung, S. Y., Jo, H.-G., Jeong, H., Heo, T., & Park, C.-S. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4474282
Effects of elevated carbon dioxide levels on response speed in cognitive test
Chen, D., Bagkeris, E., Mumovic, D., Huebner, G. M., & Ucci, M. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202339601040
ОЦІНКА СТАНУ ЗДОРОВ’Я СТУДЕНТІВ-МЕДИКІВ НА ФОНІ ЗМІНИ ЧИСТОТИ ПОВІТРЯ ТА МІКРОКЛІМАТУ
Ярема, О. М., Bilyk, Y. O., Krytska, H., Stravskyy, Y. S., Podobivskiy, S. S., & Fedoniuk, L. Y. (2023) · Вісник соціальної гігієни та організації охорони здоров я України · doi:10.11603/1681-2786.2023.1.13858
Shirzad, M., Riesen, J. V., Behboodpour, N., & Heath, M. D. (2023) · Life Sciences in Space Research · doi:10.1016/j.lssr.2023.07.003
Carbon Dioxide at TWA-TLV Alters Immune Responses to Influenza A
Schneberger, D., Kirychuk, S., Thompson, B., Zhou, Y., Aulakh, G. K., & Simonson, C. J. (2023) · Environmental science and engineering · doi:10.1007/978-981-19-9822-5_224
Keene, K., McCord, K. H., Dehwah, A. H. A., & Jung, W. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4612190
Moredock, J. L., Dutta, B., & Chatterjee, A. (2023) · Springer proceedings in earth and environmental sciences · doi:10.1007/978-3-031-46966-4_28
Infrastructure and Indoor Air Quality in Educational Buildings in South AfricaPreprint
van der Walt, R. E., Grobbelaar, S. S. S., & Booysen, M. J. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4627036
Edelmers, E., Kauce, R., Konopecka, V., Veignere, E., Sprūdža, K. L., Neļķe, V., Citskovska, E., Šipilova, V., Čikuts, M., Skrebele, E., et al. (2023) · Environmental and Climate Technologies · doi:10.2478/rtuect-2023-0055
Batista, M., Bulgim, O., Matus, E., Estrella, J., Gittens, R. A., Gittens, R. A., Gittens, R. A., Molino, J. J., Molino, J. J., & Molino, J. J. (2023) · American Journal of Applied Sciences · doi:10.3844/ajassp.2023.18.26
“Since O 2 sensors are affordable, they have been used as a natural data source for indoor air quality, considering that CO 2 levels in indoor environments have been linked to harmful health in general (Satish et al ., 2012).”
MethodMonitoring Environments with New Generation Devices
Lendínez, A. M., Ruiz, J. L. L., Rodríguez, M. P. B., Díaz-Jiménez, D., Nugent, C., & Espinilla, M. (2023) · Lecture notes in networks and systems · doi:10.1007/978-3-031-48306-6_3
Zhao, L., Tam, C., Zhao, Y., & Liao, Z. (2024) · doi:10.32920/25363231.v1
Zhao, L., Tam, C., Zhao, Y., & Liao, Z. (2024) · doi:10.32920/25363231
Examining The Effects of Carbon Dioxide Emissions on Human Brain Activity Using Agent-Based ModelingPreprint
Alqarni, A., & Almarwaey, A. (2024) · Preprints.org · doi:10.20944/preprints202403.0590.v1
Choi, S., Kim, J., Kim, H., Cho, H., & Jang, H. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4822010
Discrete-Event Modeling of Human Behavior for Spread of Diseases on University CampusesPreprint
Griffith, H., Ruiz-Martín, C., & Wainer, G. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4806349
Ledins, P. M. (2023) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr1
(2023) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr2
(2023) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr3
Ledins, P. M. (2024) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr5
(2024) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr6
(2023) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4.pr4
Thiele, V., Monsé, C., David, M., Dębiak, M., Kolossa‐Gehring, M., Brüning, T., Bünger, J., & Sucker, K. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100035 · Cited by 1
Vorobioff, J., Boggio, N. G., Checozzi, F., Garrón, T. P., & Rinaldi, C. A. (2024) · Tecnura · doi:10.14483/22487638.19522
Percepção da qualidade do ar interior em salas de aula urbanas: estudo de caso em Vitória-ES
Silva, S. V. D. O., Pagel, É. C., Sarnaglia, A. J. Q., & Velten, F. B. (2024) · Gestão & Tecnologia de Projetos · doi:10.11606/gtp.v19i2.221080 · Cited by 2
Zhai, D., Bahadure, S., Ong, B., & Soh, Y. C. (2024) · IEEE Conference on Industrial Electronics and Applications (ICIEA) · doi:10.1109/iciea61579.2024.10664986
Borisov, B. V., Kuznetsov, G., Maksimov, V., Nagornova, T. A., & Salikhov, F. Y. (2024) · Frontiers in Heat and Mass Transfer · doi:10.32604/fhmt.2024.056758
“…have shown [17] that short-term CO 2 exposure, starting at 1000 ppm, affects cognitive abilities, including decision making and problem solving [18,19], increased heart rate, change in heart rate variability, increased blood pressure, increased peripheral blood circulation [20,21], dizziness…”
Chung, Y.-H., Chen, S., Lee, C.-L., & Chang, Y.-S. (2024) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-024-09676-9
“Air pollution and indoor environmental factors such as air quality and temperature also impact HR and changes in HRV, affecting health and the ability to learn (Pope et al., 1999; Satish et al., 2012; Zhang et al., 2017).”
Su, Y., Dai, Y., & Pfrang, C. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.110563
Gao, C., Wang, Z., Wang, C., Wang, T., & Wang, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3519346
Spatial-Temporal Prediction Method for Air Quality Data Collected by WSN
Usui, K., Mochizuki, S., & Komuro, N. (2024) · International Conference on Information and Communication Technology Convergence (ICTC) · doi:10.1109/ictc62082.2024.10826831
García, G., Acosta, I. J., Campano, M. Á., & Bustamante, P. (2025) · Springer proceedings in earth and environmental sciences · doi:10.1007/978-981-96-1270-3_2
Harnessing neuroplasticity’s features for civilian spaceflight through remediation and treatment
Corbally, C. J. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13850-8.00001-4
The Influence of In-Car Air Quality on Drivers’ Brain States with Hybrid Fnirs and EegPreprint
Wang, C., Liu, S., Gao, Y., Cheng, X., Hu, X., Solovey, E., & Lin, Y. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5157858
Carbon Dioxide Real-time Tracking Exploiting Light-Induced Thermoelastic Spectroscopy
Melchiorre, L., Menduni, G., Zifarelli, A., Giglio, M., Patimisco, P., Magno, G., Sampaolo, A., Grande, M., & Spagnolo, V. (2024) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon55916.2024.10905537
“CO 2 is also monitored to ensure human health and safety; for this reason, in indoor environments like offices, schools, and hospitals, high CO 2 levels can lead to discomforts, to a decrease in mental focus, and to respiratory issues [3].”
Application of a occupant-specific integrated air quality index using health risk assessment
Park, S., Jeong, J., Noh, K.-C., & Lee, C.-M. (2024) · Journal of Odor and Indoor Environment · doi:10.15250/joie.2024.23.4.363
Wang, F., Xu, H., Lei, T., Xu, Y., Wang, H., & Wang, L. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.03.21.644619
“The CO 2 concentration was controlled at 947 ± 32 ppm to ensure optimal air quality during the trials (Satish et al., 2012).”
InfluentialHuman Nervous System and Behavioral Toxicology
Fiedler, N. L., & Wiersielis, K. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-95488-4.00231-x
Liu, X., Chu, X., Li, C., Liu, H., Zheng, Y., & Li, H. (2025) · Dalton Transactions · doi:10.1039/d5dt00181a
AI-Based Driver Drowsiness Detection via Facial Landmark Tracking and Metahuman Reconstruction
Kim, C., Jo, C., Shin, J., Seo, Y., & Kim, B. (2025) · Journal of the korean society of manufacturing technology engineers · doi:10.7735/ksmte.2025.34.2.113
Assessing the impact of high and low occupancy on air quality inside a library
Jain, S., Goel, A., Ola, D., Addya, A., & Kabdal, Y. (2025) · Sadhana · doi:10.1007/s12046-025-02737-7
“High levels of CO 2 have been linked to discomfort, fatigue, headaches, and decreased cognitive function [26].”
Tang, W., Yan, S., Shawky, M. A., Couraud, B., Imran, M. A., Flynn, D., & Taha, A. (2025) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc61545.2025.10978376 · Cited by 1
Homkanchan, S., Puttha, J., Tephiruk, N., Teerakawanich, N., Kanokbannakorn, W., & Srisonphan, S. (2024) · IEEE International Smart Cities Conference (ISC2) · doi:10.1109/isc260477.2024.11004229
“The initial CO 2 concentration in the chamber is set to around 7500 ppm, significantly higher than typical ambient room levels (~1000 ppm) [14].”
Dominski, F. H., Buonanno, G., Stabile, L., & Andrade, A. (2025) · Sport Sciences for Health · doi:10.1007/s11332-025-01442-6
“There is evidence that even in moderate concentrations this gas can alter human performance and influence decision-making [42].”
Pei, J., Qu, M., Dong, X., Xu, X., Lv, M., Wang, X., Zhao, R., & Zhao, Z.-Z. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5271798
Fernando, M. M. D. N. P., & Silva, N. D. (2025) · International Conference on Facilities Management Futures (FMF) · doi:10.31705/icfmf2025.9
Ghazanfari, N., & Reichard, G. (2025) · CIB Conferences · doi:10.7771/3067-4883.2034
William Happer, Ph.D. (Princeton): The Consequential Climate Physicist
Shanmugam, G. (2025) · Indian Association of Sedimentologists · doi:10.51710/jias.v4i1.428
VIVIENDO ENTRE MUROS... Y DIÓXIDO DE CARBONO: CALIDAD DEL AIRE INTERIOR DURANTE EL CONFINAMIENTO
Moreno, F. I. G., Alarcón-Ruiz, E., López-Huerta, F., & Caballero‐Briones, F. (2025) · HISTORIAS DE FENGACOS · doi:10.29059/hf.20250630-23
Enhancing Thermal Comfort and Co2 Uniformity Using Fabric Air Dispersion Systems in Lecture HallsPreprint
Choi, S., Kim, H., Jang, H., & Kim, J. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5342468
Impact of mask-wearing-related CO2 exposure on performance – A global survey
Hurley, R. F., Mangoubi, O., Zhang, K., & Liu, S. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113537
Effects of in-car CO2 concentration on driving: a preliminary study with taxi drivers
Shimazaki, K., Ishigaki, Y., Hayashi, K., & Fujita, K. (2025) · Environmental and Occupational Health Practice · doi:10.1539/eohp.2025-0001
The influence of in-car air quality on drivers’ brain states with hybrid fNIRS and EEG
Wang, C., Gao, Y., Cheng, X., Hu, X., Solovey, E., Lin, Y., & Liu, S. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113678
Bugarski, A. D., Ritter, D. A., & Moredock, J. L. (2025) · Mining Metallurgy & Exploration · doi:10.1007/s42461-025-01345-7
Green Photocatalytic Air Purification
Singh, S., Anntar, H., Jangir, S., & Chand, S. (2025) · Clean Energy Production Technologies · doi:10.1007/978-981-95-1618-6_7
Assessing exposure of young children to air pollutants in urban homes in Alexandria, Egypt
Abdel-Salam, M. M. M. (2025) · International Journal of Environmental Health Research · doi:10.1080/09603123.2025.2572407
“Recent monitoring studies have shown that indoor CO ₂ concentrations frequently exceed recommended levels, affecting comfort and cognitive performance (Satish et al. 2012; Persily and de Jonge 2017).”
Breathwork in VestAndPage Performance Practice
Pagnes, A., & Stenke, V. (2024) · Performance Research · doi:10.1080/13528165.2024.2511383
Enhancing Cabin Air Quality: Challenges, Impact and Advanced Climate Control Solutions
Sharma, S. (2025) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2025-28-0433 · Cited by 1
Mohammed, L. J., Salih, S. A., & Ja’afar, M. F. Z. (2025) · ALAM CIPTA International Journal Of Sustainable Tropical Design & Practice · doi:10.47836/ac.18.s2.paper08
Wang, X., Tian, H., Huo, X., Shu, G., Luo, K. H., Wu, M., & Yang, Z. (2025) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2025.104363
Exploring CO2-Distribution in Educational Spaces: Results from Experimental Field StudiesPreprint
Plörer, D., Hammes, S., Huber, J., Pfluger, R., & Öttl, S. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5849029
Kim, M. K., Cremers, B., & Liu, J. (2025) · E3S Web of Conferences · doi:10.1051/e3sconf/202567207008
Winter Air Exchange in a Nursing Home Room: A Numerical Analysis of Actual Ventilation Times
Nardecchia, F., Romagna, M., & Grignaffini, S. (2025) · Journal of Physics Conference Series · doi:10.1088/1742-6596/3143/1/012042
An intelligent mobile direct air capture robot system based on temperature-vacuum swing adsorptionPreprint
Chen, Z., Zhan, T., Miao, Y., Zhang, Z., He, C., Gu, Y., Jiang, K., Redonnet, S., & Li, J. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5889027
Choi, S., Kim, H., Jang, H., Kim, J., Hong, J., Choi, J., & Hong, T. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.115022
Liu, Y., Zhao, M., Shao, Y., Yan, L., & Zhu, X. (2021) · Figshare · doi:10.6084/m9.figshare.14396836
Aliaj, B., Xhexhi, K., & Nika, B. (2026) · Research Square · doi:10.21203/rs.3.rs-8364283/v1
Indoor air quality and health exposure in an educational campus in Western India
Shrivastava, A., Konwar, D., & Bhattu, D. (2026) · Atmospheric Environment · doi:10.1016/j.atmosenv.2026.121790
Towards Healthier Workspaces: IoT-Based Thermal Comfort and IAQ Monitoring
Shriram, S. (2025) · International Conference on Communication and Smart Devices (ICCoSD) · doi:10.1109/iccosd66074.2025.11348383
IoT-Enabled Feedback System for Monitoring Indoor Air Quality in Laboratory Environments
Shriram, S., Chellamani, G. K., & Bhavaneesh, L. (2025) · International Conference on Communication and Smart Devices (ICCoSD) · doi:10.1109/iccosd66074.2025.11348512
Mahmoud, S. S., & Elshibly, S. M. (2026) · Journal of Applied Toxicology · doi:10.1002/jat.70071
“…range of accepted occupational exposure limits, while 10% CO 2 represents an extreme but plausible exposure condition observed under poorly ventilated or enclosed industrial settings (NIOSH Pocket Guide to Chemical Hazards 2025; Occupational Safety and Health Standards, n.d.; Satish et al. 2012).”
Caramizoiu, S., Zichișanu, M.-D.-Ș., Chiriță, T.-P., Iordache, A., Florea, A.-M., Bita, B. I., & Iordache, S.-M. (2025) · International Conference on Developments in eSystems Engineering (DeSE) · doi:10.1109/dese68208.2025.11367954
Essien, E., & Umoh, E. (2026) · Research Square · doi:10.21203/rs.3.rs-8763269/v1
Günzel, M., Stinglhammer, S., & Jensch, W. (2026) · Developments in the Built Environment · doi:10.1016/j.dibe.2026.100878
UHAB-1: Physiological responses to a 48-hour spaceflight analog mission underwater
Möller, F. N., Haarslev, C., Mølgaard, J., Harris, N. S., Petersen, J. C. G., & Petersen, L. G. (2026) · Life Sciences in Space Research · doi:10.1016/j.lssr.2026.02.006
Design and Implementation of a Microwave CSRR Sensor for CO 2 Gas Detection in Ambient Air
Banerjee, A., Tzourmpakis, P., Fatani, F., & Shamim, A. (2025) · International Microwave and Antenna Symposium (IMAS) · doi:10.1109/imas66694.2025.11387498
Carbonation Behavior of an Aged Reinforced Concrete Building in Seoul
Sim, S.-R. (2026) · Buildings · doi:10.3390/buildings16050927
Seong, N., & Kim, D. (2026) · KIEAE Journal · doi:10.12813/kieae.2026.26.1.077
LOW BUDGET MEASURING DEVICE FOR DETERMINING CARBON DIOXIDE LEVELS IN INDOOR SPACES
Pasic, R., Kuzmanov, I., & Mijakovska, S. (2026) · TEMEL Citizens Association Center for Development Organization Research Promotion of Values Education and Promotion of Youth · doi:10.52576/temel2610101p
Olatona, G. I., Oyedokun, S. M., & Adisa, S. A. (2026) · Turkish Journal of Forecasting · doi:10.34110/forecasting.1829638
Choi, Y., Muthuraman, G., & Kim, D. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.175397
Dalay, L., & Aytaç, G. (2026) · Sustainability · doi:10.3390/su18063112
Impact of indoor environment quality on autistic behaviours in autism schools of Saudi Arabia
Qutub, R. A., Luo, Z., Essah, E., Tavassoli, T., Marcham, H., & Qihong, D. (2026) · Environmental Pollution · doi:10.1016/j.envpol.2026.127992
Regenerable CO2 sorbents based on potassium carbonate and carbon nanotubes
Shevtsov, T. V., Suknev, A. P., Veselovskaya, J. V., Leonova, A. A., Gerasimov, E. Y., Yatsenko, D. A., Moseenkov, S. I., Kuznetsov, V. L., & Derevschikov, V. S. (2026) · Kataliz v promyshlennosti · doi:10.18412/1816-0387-2026-2-3-17
Die Dimensionen der Architekturpsychologie
Gauer, S. (2026) · Springer eBooks · doi:10.1007/978-3-662-72370-8_3
Sensorless Estimation of In-Cabin CO 2 Concentration for Model-Based Air Recirculation Control
Stürmer, M., Geier, B., Hofstetter, M., & Hirz, M. (2026) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2026-01-0130
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

