Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 701–800 of 1,000
Liu, Y., Zhang, Q., & Li, W. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116294 · Cited by 3
Li, Z., Song, G., Zhang, Q., Liu, Y., Yu, J., & Fan, F. (2025) · Developments in the Built Environment · doi:10.1016/j.dibe.2025.100792 · Cited by 5
Schreiber, L., Schuh, B., Shchegelskiy, K., Wardah, W., Büyüktaş, T. M. K., Möller, S., & Spang, R. P. (2025) · International Conference on Quality of Multimedia Experience (QoMEX) · doi:10.1109/qomex65720.2025.11219970 · Cited by 2
Assessment of indoor air quality in a primary school
Dosumu, A. A., & Colbeck, I. (2025) · Discover Environment · doi:10.1007/s44274-025-00479-1 · Cited by 2
Zhan, G., Duan, Y., Chang, F., Shi, S., Zeng, S., Bai, Y., Bai, L., Li, Z., & Zhang, X. (2025) · Separation and Purification Technology · doi:10.1016/j.seppur.2025.135209 · Cited by 2
The influence of cabin environment on takeover performance in conditional automated driving
Wang, Z., Sheng, H., Gu, F., Zhao, L., Wang, Z., & He, D. (2025) · Transportation Research Part F Traffic Psychology and Behaviour · doi:10.1016/j.trf.2025.103478 · Cited by 2
Qutub, R. A., Luo, Z., Essah, E., & Abdou, A. A. (2026) · Indoor Air · doi:10.1155/ina/6946065 · Cited by 2
Evaluation of photobioreactor designs for potential application as microalgal façade systems
Tekin, Z., Al-Hammadi, M. S., Çalışkan, G., DOĞU, D. I., Mengi, O., Deniz, D., & Güngörmüşler, M. (2026) · Scientific Reports · doi:10.1038/s41598-026-42461-8 · Cited by 3
Zang, T., Awada, M., Becerik-Gerber, B., Roll, S. C., Lucas, G., & Narayanan, S. (2026) · Indoor Environments · doi:10.1016/j.indenv.2026.100171 · Cited by 3
Moltedo-Medina, J., Trebilcock, M., Rubio-Bellido, C., & Pérez-Fargallo, A. (2026) · Buildings · doi:10.3390/buildings16101943 · Cited by 2
Carbon Dioxide Exposure Resulting From Hood Protective Equipment Used in Joint Arthroplasty Surgery
Patel, S., Fine, J. M., Lim, M. J., Copp, S. N., Rosen, A. S., West, J. B., & Prisk, G. K. (2017) · The Journal of Arthroplasty · doi:10.1016/j.arth.2017.03.047 · Cited by 2
Elevated Environmental Carbon Dioxide Exposure Confounding Physiologic Events in Aviators?
Andicochea, C. T., Henriques, M. E., Fulkerson, J., Jay, S., Chen, H., & Deaton, T. G. (2019) · Military Medicine · doi:10.1093/milmed/usz092 · Cited by 2
Chikamoto, T., & MIMURA, R. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911102068 · Cited by 2
Hossain, M. S., Che, W., & Lau, A. K. H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19010565 · Cited by 2
“The outdoor CO2 concentration level is lower than the CO2 concentration in indoor environments because of human occupancy [41].”
BackgroundA Smart System for the Contactless Measurement of Energy Expenditure
Sprowls, M., Victor, S., Mora, S. J., Osorio, O., Pyznar, G., Destaillats, H., Wheatley, C. M., Johnson, B. D., Kulick, D., & Forzani, E. (2022) · Sensors · doi:10.3390/s22041355 · Cited by 2
Stern, A. G. (2018) · Energy, environment, and sustainability · doi:10.1007/978-981-13-3284-5_13 · Cited by 2
KAYILI, M. T., & Yetiş, C. (2023) · GRID - Architecture Planning and Design Journal · doi:10.37246/grid.1031184 · Cited by 2
Indoor Air Quality Guidelines Connection to IAQ Certification and Labelling Process
Sprūdža, K. L., Kļaviņa, A., Berzina, B., Kauce, R., & Martinsone, Ž. (2023) · Environmental and Climate Technologies · doi:10.2478/rtuect-2023-0003 · Cited by 3
Pang, Z., Lu, X., Hu, P., O’Neill, Z. D., & Wang, Q. (2023) · Journal of Building Performance Simulation · doi:10.1080/19401493.2023.2208558 · Cited by 3
“…rate but typically ranging from 35,000 ppm to 50,000 ppm (Persily and de Jonge 2017; Washington State University 2013), is much higher than the background CO 2 concentration of the outdoor air, usually on a stable level between 350 and 400 ppm (Erdmann, Steiner, and Apte 2002; Satish et al. 2012).”
BackgroundChan, M., Rogak, S., & Rysanek, A. (2023) · E3S Web of Conferences · doi:10.1051/e3sconf/202339602029 · Cited by 2
Empirical Studies Assessing the CO2 Levels in Indoor Spaces
Gangrade, S., Vamsi, B., Prasannaa, Raj, S., & Dhariwal, J. (2023) · Smart innovation, systems and technologies · doi:10.1007/978-981-99-0293-4_16 · Cited by 2
Bozkurt, S., & Bozkurt, S. (2023) · Global Challenges · doi:10.1002/gch2.202300120 · Cited by 2
Gaßner, S., Essing, S., Tumpold, D., Schmitt, K., & Wöllenstein, J. (2024) · Journal of sensors and sensor systems · doi:10.5194/jsss-13-219-2024 · Cited by 2
Li, X., Xiong, J., Zhang, Q., & Wang, Q. (2024) · Energies · doi:10.3390/en17184613 · Cited by 2
IAQ and ventilation measurements at the “ZEB Laboratory” office building in Norway
Alonso, M. J., Breesch, H., Lassen, T. E., Carton, Q., & Mathisen, H. M. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100063 · Cited by 3
Griffith, H., Ruiz-Martín, C., & Wainer, G. (2024) · Computers & Industrial Engineering · doi:10.1016/j.cie.2024.110732 · Cited by 2
“[15].”
Near-Room-Temperature CO2 Capacitive Sensors Based on Hybrid Polymer Sensitive Materials
Ghouma, A., Salem, B., Cavalaglio, S., Plaussu, J. R., Crowin, G., Abbes, R. B., Monfray, S., Fiorido, T., Bendahan, M., & Souifi, A. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3537180 · Cited by 2
“As various studies have pointed out above certain concentration thresholds, carbon dioxide has been linked to a myriad of adverse effects on human health and cognitive function [2], [3].”
Dynamic weather-based scheduling for achieving energy savings in factories
Chao, K.-Y. C., Liu, Y., Lee, C., Lin, J.-H., Cheng, C.-P., Lee, M.-H., Kuo, H., & Chen, T.-J. G. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115604 · Cited by 2
Moustakas, T., Fanaridou, K., Karatzinis, G. D., Vougiatzis, G., Bouzos, O., Mateus, N. M., Michailidis, I., & Kosmatopoulos, E. B. (2025) · Energy Reports · doi:10.1016/j.egyr.2025.03.007 · Cited by 2
López-Carreño, R.-D., Pardo-Bosch, F., Aidarov, S., Boix‐Cots, D., & Pujadas, P. (2025) · Applied Sciences · doi:10.3390/app15074033 · Cited by 2
Chen, F., Huang, W.-C., Hwang, W.-C., Wang, Y., Ye, J., & Hung, H. (2025) · Indoor Air · doi:10.1155/ina/3358673 · Cited by 2
Sofuoǧlu, S. C., Arı, A., Civan, M., Dumanoğlu, Y., Güllü, G., Menteşe, S., Onat, B., Şahin, Ü. A., & Toksoy, M. (2025) · Atmospheric Pollution Research · doi:10.1016/j.apr.2025.102743 · Cited by 4
基于2 μm激光二极管和Herriott多光程吸收池的高灵敏二氧化碳气体传感器(特邀)
Chenglong, 王. W., Jiabao, 谢. X., Ruobin, 庄. Z., Haoyang, 林. L., Leqing, 林. L., Cui, R., Hongpeng, 武. W., Huadan, 郑. Z., & Lei, 董. D. (2023) · ACTA PHOTONICA SINICA · doi:10.3788/gzxb20235210.1052406 · Cited by 2
Climate Action Gaming Experiment: Methods and Example Results
Singer, C. E., & Matchett, L. (2015) · Challenges · doi:10.3390/challe6020202 · Cited by 10
“Increases in atmospheric CO2 levels over preindustrial values decrease pot balances even if global average temperature is held constant, due to direct effects on human physiology [37] and other environmental effects including ocean acidification.”
BackgroundAnalysis of Large-Scale Energy Efficiency Programs
Krarti, M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-849869-9.00009-0 · Cited by 3
Mishchuk, O. (2019) · Technology audit and production reserves · doi:10.15587/2312-8372.2019.188743 · Cited by 2
Measuring Elevated Indoor Carbon Dioxide Concentration from Unsuitable Condition of Indoor Plant
Pamonpol, K., Tokhun, N., & Somparn, A. (2020) · International Conference and Utility Exhibition on Energy, Environment and Climate Change (ICUE) · doi:10.1109/icue49301.2020.9307080 · Cited by 3
“At this CO2 level, human health could be affected by associating with headaches, sleepiness, stagnant, stale, poor concentration, loss of attention, increased heart rate, slight nausea, restrict lung behavior, and unhealthy blood CO2 levels [24], [26], [28], [32].”
BackgroundOn reducing CO2 concentration in buildings by using plants
Franek, O., & Jarský, Č. (2021) · Acta Polytechnica · doi:10.14311/ap.2021.61.0617 · Cited by 2
Indoor Air Quality in the Context of Climate Change
Kinney, P. L. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_74-1 · Cited by 2
Energy performance and indoor air quality in modern buildings in Greenland—Case study Apisseq
Kotol, M., Rode, C., & Vahala, J. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1012418 · Cited by 2
“Nevertheless, a recent study on effects of CO2 on human performance (Satish et al. 2012) found a clear”
BackgroundA global approach to evaluate IAQ and thermal comfort in a healthy building perspective
Sicurella, F., & Colamesta, P. (2015) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-cisbat2015-387-392 · Cited by 2
MODELING OF INDOOR AIR QUALITY
Teodosiu, C. I. (2011) · International Multidisciplinary Scientific GeoConference SGEM ... · doi:10.5593/sgem2015/b41/s19.125 · Cited by 2
Effects of inhalation exposure to carbon dioxide on human health in indoor environment
Azuma, K. (2018) · Indoor Environment · doi:10.7879/siej.21.113 · Cited by 2
Tu, Z., Geng, S., & Li, Y. (2020) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/510/5/052026 · Cited by 2
The Study on Association between Urban Green Space and Temperature Changes in Mega City
Padon, A., Punson, B., Iamtrakul, P., & Klaylee, J. (2020) · International Conference and Utility Exhibition on Energy, Environment and Climate Change (ICUE) · doi:10.1109/icue49301.2020.9307077 · Cited by 4
Caruso, M., Jabbour, J., Neale, C., Summerville, A., Walters, A., Heydarian, A., Small, A. A., & Varnosfaderani, M. P. (2022) · Systems and Information Engineering Design Symposium · doi:10.1109/sieds55548.2022.9799313 · Cited by 2
Indoor Air Quality Diagnosis Program for School Multi-Purpose Activity and Office Spaces
Lee, Y.-K., Kim, Y., & Kim, G. (2022) · Energies · doi:10.3390/en15218134 · Cited by 2
Effects from Exposures to Human Bioeffluents and Carbon Dioxide
Zhang, X., Mishra, A. K., & Wargocki, P. L. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_63 · Cited by 5
Contribuições para a qualidade do ar interior em salas de aula pós pandemia de COVID-19
Silva, S. V. D. O., & Pagel, É. C. (2023) · PARC Pesquisa em Arquitetura e Construção · doi:10.20396/parc.v14i00.8670256 · Cited by 2
Zhang, N., Srivastava, A., Li, X., Li, Y., Zhou, Z., Bittner, A., Zhou, X., & Dehé, A. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325246 · Cited by 2
“High-concentration CO 2 exposure makes humans tired and impairs their attention [7] [8].”
BackgroundA Regularization Approach for Identifying Cumulative Lagged Effects in Smart Health Applications
Srinivasan, K. K., Currim, F., Ram, S., Mehl, M. R., Lindberg, C. M., STERNBERG, E. M., Skeath, P. R., Herzl, D., Herzl, R., Lunden, M. M., et al. (2017) · International Conference on Digital Health · doi:10.1145/3079452.3079503 · Cited by 2
“The cumulative lag is also known as area under the curve (AUC) [1] or window of exposure [16] effect.”
Backgroundclimify.org: an online solution for easy control and monitoring of the indoor environment
Calì, D., Kindler, E., Ebrahimy, R., Bacher, P., Hu, K., Østrup, M. L., Bachalarz, M., & Madsen, H. (2019) · E3S Web of Conferences · doi:10.1051/e3sconf/201911105006 · Cited by 3
Continued Development of a Liquid Amine Carbon Dioxide Removal System for Microgravity Applications
Alvarez, G., DeGraff, G., Swickrath, M. J., Belancik, G. A., & Sweterlitsch, J. (2019) · ThinkTech (Texas Tech University) · Cited by 2
Kermeci, P. (2018) · UEA Digital Repository (University of East Anglia) · Cited by 2
Buildings in Higher Education: Energy Consumption and Environmental Quality
Yang, J., & Lee, S. E. (2014) · CRC Press eBooks · doi:10.1081/e-eee2-120054023 · Cited by 2
Oelßner, W. (2019) · Wiley eBooks · doi:10.1002/9783527688302.ch13 · Cited by 2
Zhang, D., & Zhang, L. (2023) · Preprints.org · doi:10.20944/preprints202306.1489.v1 · Cited by 2
Choi, J.-S., & Kim, E.-J. (2019) · Sustainability · doi:10.3390/su11072069 · Cited by 1
Moritani, M., Watanabe, N., Miyamoto, K., Itoda, K., Imani, J., Aoyama, H., & Takefuji, Y. (2020) · Applied Sciences · doi:10.3390/app10134631 · Cited by 1
eAir: an energy efficient air quality management system in residential buildings
Huang, Z., & Zhu, T. (2014) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/2676061.2675043 · Cited by 1
Optimal Placement of Heat Exchangers in a Carbon Capture-Based Ventilation System
Harrouz, J. P., Ghali, K., & Ghaddar, N. (2023) · Renewable Energy and Power Quality Journal · doi:10.24084/repqj21.325 · Cited by 2
Comparison of Face Masks by Arduino Sensors
Balkir, B. (2023) · Cornell Undergraduate Research Journal · doi:10.37513/curj.v2i2.733 · Cited by 1
Bukhari, S. S. I. (2024) · Punjab University journal of zoology · doi:10.17582/journal.pujz/2024/39.1.107.118 · Cited by 1
“This focuses out to the moo ventilation at that time but how much it must have influenced the tenants is still obscure (Satish et al ., 2012).”
InfluentialJin, R. N., Inada, H., Momma, H., Ma, D., Yuan, K., & Nagatomi, R. (2024) · Environmental Research · doi:10.1016/j.envres.2024.119785 · Cited by 1
Kumari, N., Sahu, V., Chintala, K., M., S. C., Durga, C. S., Mantravadi, H. B., Peddapalegani, P., & Ealla, K. K. R. (2025) · Bulletin of Atmospheric Science and Technology · doi:10.1007/s42865-025-00092-3 · Cited by 1
“Furthermore, CO 2 levels above 600 ppm have been shown to cause headaches, irrita - tion, fatigue, sleep apnea, and poor cognition (Seppanen et al. 1999; Satish et al. 2012 ; Allen et al. 2016; Petersen et al. 2016).”
Qualidade do ar interior em edifícios de saúde e sistemas de ventilação
Schroeffer, K. G., & Pagel, É. C. (2025) · PARC Pesquisa em Arquitetura e Construção · doi:10.20396/parc.v16i00.8674496 · Cited by 1
Nazarenko, Y., & Narayanan, C. (2025) · Atmosphere · doi:10.3390/atmos16030309 · Cited by 2
Erdoğan, S., Akalin, G., & Balsalobre‐Lorente, D. (2025) · Sustainable Development · doi:10.1002/sd.3413 · Cited by 2
Adverse Effects of the Long-term use of an N95 Respirator in Healthcare Workers
Takami, H., Mitsuhashi, T., Usuda, D., Nomura, T., & Sugita, M. (2025) · Juntendō Igaku/Juntendo igaku · doi:10.14789/ejmj.jmj24-0050-oa · Cited by 1
CO 2 concentration in six schools located in Palma – a comparative evaluation
Llabrés-Morey, M.-A., Hormigos-Jiménez, S., & Merino, M. D. R. (2025) · Building Research & Information · doi:10.1080/09613218.2025.2517366 · Cited by 1
“…well-being impacts in daily indoor environments, despite not being the most chemically toxic compound (Baudet et al., 2022; Health Canada, 2021; Kumar et al., 2023; Lin et al., 2023; NCCEH-CCSNE National Collaborating Centre for Environmental Health, 2010; Park et al., 2025; Satish et al., 2012).”
Madsen, S. T., Weidema, B. P., & Gershuny, J. (2025) · Review of Economics of the Household · doi:10.1007/s11150-025-09792-3 · Cited by 1
Miyamoto, M., Mizutani, A., Takamatsu, R., Oumi, Y., Uemiya, S., Watanabe, S., & Nakanishi, T. (2025) · JOURNAL OF CHEMICAL ENGINEERING OF JAPAN · doi:10.1080/00219592.2025.2557372 · Cited by 2
Ivanova, M., Angelova, R. A., & Sofronova, D. (2025) · Applied Sciences · doi:10.3390/app152010941 · Cited by 1
Blasco, M. J. V., Teruel-Recio, P., Smaha, K., & Gandía‐Romero, J. M. (2025) · Sustainability · doi:10.3390/su172310534 · Cited by 1
Wang, Z., Sheng, H., Gu, F., Yujie, Z., Zhao, L., Wang, Z., & He, D. (2025) · Ergonomics · doi:10.1080/00140139.2025.2596871 · Cited by 1
Saleh, A. D., Khoukhi, M., Mohammad, A., Marzouqi, A. H. A., & Bessadok-Jemai, A. (2025) · Frontiers in Built Environment · doi:10.3389/fbuil.2025.1626770 · Cited by 1
Yang, Y., Huajiang, D., Wang, N., Zhang, J., Zhang, Z., Sun, Q., Zhang, W., Wang, J., Liu, J., Liu, Y., et al. (2026) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2025.119578 · Cited by 2
Zhang, X., Liu, Y., Wang, M., & Xie, J. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114247 · Cited by 3
İlgördü, Ö. Ö., & Başak, S. (2026) · Environments · doi:10.3390/environments13020099 · Cited by 1
Pei, J., Qu, M., Dong, X., Xu, X., Lv, M., Cui, J., Wang, X., Zhao, R., & Zhao, Z. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114362 · Cited by 1
Effects of Dynamic Increases in Indoor CO2 Concentration on Daytime Sleepiness: An EEG-Based Study
Guo, B., Wang, W., Yan, B., & Fan, H. (2026) · Buildings · doi:10.3390/buildings16040752 · Cited by 1
Microalgal photobioreactors as living air purifiers for better indoor carbon dioxide quality control
Komkhum, T., Winterburn, J. B., Wongsirichot, P., Janpum, C., & In-na, P. (2026) · Biomass and Bioenergy · doi:10.1016/j.biombioe.2026.109178 · Cited by 2
Fosu-Amankwah, K., Owusu, S., Mensah, P. K., Asamoah, E., & Damoah, R. (2026) · African Transport Studies · doi:10.1016/j.aftran.2026.100088 · Cited by 1
Chen, E. X., Malkawi, A. M., Samuelson, H. W., Shen, G., & Li, N. (2026) · Energy and Buildings · doi:10.1016/j.enbuild.2026.117337 · Cited by 4
Hossam, H., Tamer, R., Mohsen, M. A., Ahmed, O. S. M., Alaa, M., Mourad, J., Adel, R., Hatem, A. O. B., & Sherif, S. (2026) · Scientific Reports · doi:10.1038/s41598-026-41628-7 · Cited by 1
“Prior studies by Satish et al. 22 and Mendell et al. 29 demonstrate that elevated CO 2 levels, heat exposure, and poor ventilation negatively affect decision-making accuracy, increase fatigue, and exacerbate respiratory symptoms—effects that are particularly pronounced in children.”
InfluentialOccupancy-Aware Digital Twin for Sustainable Buildings
Smirnov, I., & Cecconi, F. R. (2026) · Buildings · doi:10.3390/buildings16081629 · Cited by 1
Maroofiazar, R., & Reveshti, A. M. (2026) · Indoor Air · doi:10.1155/ina/9959278 · Cited by 2
He, M., Tao, L., & Chen, Y. (2026) · Coatings · doi:10.3390/coatings16060646 · Cited by 1
Salunkhe, P. G., Shirole, M. R., & Mehendale, N. D. (2026) · Automation · doi:10.3390/automation7030094 · Cited by 1
“Second, peer-reviewed evidence identifies the 1500–2500 ppm range as the interval at which measurable cognitive performance decrements and physiological symptoms such as headaches and drowsiness arise, which occur consistently in enclosed-space occupants [33].”
Huang, Q., Casanova, E., Melo, A. P., Frisch, J., & van Treeck, C. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.115268 · Cited by 1
Rahad, G. M., Hossain, J., Hasan, M., Uddin, M. N., Islam, M. H., Ahmed, M. E., & Rahman, M. H. (2026) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2026.108541 · Cited by 1
Monn, C., Leiblein, T., Janser, M., Feige, A., Wallbaum, H., Inversini, L. W., & Hofmann, T. (2015) · Zürcher Hochschule für Angewandte Wissenschaften digital collection (Zurich University of Applied Sciences) · Cited by 1
eAir: an energy efficient air quality management system in residential buildings
Huang, Z., & Zhu, T. (2014) · ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation (BuildSys) · doi:10.1145/2674061.2675043 · Cited by 1
“At those levels of CO 2 concentrations recent studies have shown the effect on human health by inhibit cognitive functions, as well as impair decision-making [2].”
An Approach for Meeting Room Activity Monitoring and Analysis
Taranovs, R., Jesilevskis, V., Miezītis, G., Bļizņuks, D., Kļaviņš, Ē., Kalnins, A., & Zagursky, V. (2015) · Technologies of Computer Control · doi:10.7250/tcc.2014.009 · Cited by 1
“However, medical research [4] shows that the cause of these problems is insufficient room ventilation that leads to high CO2 concentration in the air.”
BackgroundMaddalena, R. L. (2014) · eScholarship (California Digital Library) · Cited by 1
Modelling the Dynamic Interaction between Building Performance and Occupant Well-Being
Grey, F., & Fruchter, R. (2017) · ASCE International Conference on Computing in Civil Engineering (i3CE) · doi:10.1061/9780784480847.025 · Cited by 1
Physiological performance and capabilities
Beard, B. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-101869-9.00005-4 · Cited by 1
Personal Ventilation Modeling Using a CFD Analysis
Szczepanik-Ścisło, N. (2016) · World Scientific News · Cited by 1
The Air Quality Paradigm inside Car Microenvironments; Balancing between PM2.5 and CO2 Offsets
Hofman, J., & Manna, V. P. L. (2020) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47125.2020.9278665 · Cited by 1
“Depending on some vehicle-specific parameters, like ventilation settings, number of occupants, cabin volume, indoor/outdoor leakage, driving speed and trip duration, recent studies report on resulting in-vehicle concentrations between 600 and 3000 ppm [3]–[6], while outdoor concentrations are typically ~400 ppm.”
BackgroundFuture Directions on IoT and Indoor Air Quality Management
Saini, J., Dutta, M., & Marques, G. (2021) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-030-82216-3_5 · Cited by 3
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.