Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 201–300 of 1,000
Lee, J., Kim, T. W., Chan-Sik, L., & Koo, C. (2021) · Journal of Management in Engineering · doi:10.1061/(asce)me.1943-5479.0000993 · Cited by 66
de Araújo, T., Silva, L. T., Aguiar, A., & Moreira, A. J. C. (2023) · Sensors · doi:10.3390/s23136153 · Cited by 47
Enabling advanced environmental conditioning with a building application stack
Taneja, J., Krioukov, A., Dawson-Haggerty, S., & Culler, D. (2013) · International Green and Sustainable Computing Conference · doi:10.1109/igcc.2013.6604519 · Cited by 45
“One critical opportunity in using a platform that enables rapid development of building applications is to identify and exploit the instances where an incremental addition of a piece of hardware or software enables a non-incremental benefit in performance.”
BackgroundMontgomery, J. F., Storey, S., & Bartlett, K. H. (2014) · Indoor and Built Environment · doi:10.1177/1420326x14530999 · Cited by 39
Luther, M., Horan, P., & Tokede, O. (2017) · Architectural Science Review · doi:10.1080/00038628.2017.1416576 · Cited by 39
“However, in a study by Satish et al. (2012), it was found that at CO2 concentrations over 1000 ppmsymptomsof failure indecision-makingbegin to show in six of the nine metrics evaluated, and that at 2500 ppm, such failure is clear.”
BackgroundIndoor Air Quality and Cognitive PerformancePreprint
Künn, S., Palacios, J., & Pestel, N. (2019) · SSRN Electronic Journal · doi:10.2139/ssrn.3460848 · Cited by 58
“This length is similar to the average exposure time in epidemiological studies exploring the effect of CO2 or temperature on cognition (e.g. Satish et al., 2012).”
BackgroundEngeroff, T., Groneberg, D. A., & Niederer, D. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00388-6 · Cited by 45
“Although it is likely that the aforementioned effects may not lead to clinically relevant hypoxia or hypercapnia, the slightly elevated CO2 may still affect cognitive performance and could increase the risk for headache [9].”
BackgroundInfluence of Indoor Climate on Employees in Office Buildings—A Case Study
Kapalo, P., Vilčeková, S., Mečiarová, Ľ., Domniţa, F. V., & Adamski, M. (2020) · Sustainability · doi:10.3390/su12145569 · Cited by 38
Chen, E. X., Han, X., Malkawi, A. M., Zhang, R. C., & Li, N. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110519 · Cited by 47
Freiberger, J. J., Derrick, B. J., Natoli, M. J., Akushevich, I. V., Schinazi, E. A., Parker, C., Stolp, B. W., Bennett, P. B., Vann, R. D., Dunworth, S., et al. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00534.2016 · Cited by 37
Building Occupancy Behavior and Prediction Methods: A Critical Review and Challenging Locks
Kanthila, C., Boodi, A., Beddiar, K., Amirat, Y., & Benbouzid, M. (2021) · IEEE Access · doi:10.1109/access.2021.3083534 · Cited by 50
“ing, this shows the importance of keeping CO2 level below in the admissible rage in the indoors [77], [78].”
BackgroundThe nexus between in-car aerosol concentrations, ventilation and the risk of respiratory infection
Kumar, P., Omidvarborna, H., Tiwari, A., & Morawska, L. (2021) · Environment International · doi:10.1016/j.envint.2021.106814 · Cited by 43
A novel real-time carbon dioxide analyzer for health and environmental applications
Zhao, D., Miller, D., Xian, X., Tsow, F., & Forzani, E. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.12.110 · Cited by 37
Dharmasastha, K., Samuel, D. G. L., Nagendra, S. M. S., & Maiya, M. P. (2022) · Energy and Built Environment · doi:10.1016/j.enbenv.2022.04.003 · Cited by 40
Palacios, J., Eichholtz, P. M. A., Willeboordse, M., & Kok, N. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-031233 · Cited by 45
“Satish et al 23 find that, relative to a baseline of 600 ppm of CO 2 (close to outdoor levels), healthy adults exposed to 2500 ppm of CO 2 for 2.5 hours scored 44%–94% lower along different cognitive dimensions, such as crisis response, or information usage.”
InfluentialPang, L., Zhang, J., Cao, X., Wang, X., Liang, J., Zhang, L., & Guo, L. (2020) · Indoor Air · doi:10.1111/ina.12746 · Cited by 36
Inflammatory responses to acute elevations of carbon dioxide in mice
Thom, S. R., Bhopale, V. M., Hu, J., & Yang, M. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00343.2017 · Cited by 39
“Breathing CO2 at ~1,000 ppm for 8 h, or higher concentrations for 2–3 h, causes cognitive dysfunction (2, 17, 33) and may cause subtle cardiovascular effects (17).”
BackgroundSu, W., Ai, Z., Liu, J., Yang, B., & Wang, F. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.121504 · Cited by 36
Parhizkar, H., Taddei, P., Węziak‐Białowolska, D., McNeely, E., Spengler, J. D., & Laurent, J. G. C. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110984 · Cited by 44
Laurie, S. S., Christian, K. H., Kysar, J. E., Lee, S. M. C., Lovering, A. T., Macias, B. R., Moestl, S., Sies, W., Mulder, E. R., Young, M., et al. (2020) · The Journal of Physiology · doi:10.1113/jp279383 · Cited by 35
“However, prospective studies that exposed adults to mild levels of CO2 have reported decreases (Satish et al. 2012), no change (Rodeheffer et al. 2018; Zhang et al. 2016) and increases (Scully et al. 2019) in performance, highlighting the challenges in interpreting a direct link between exposure to…”
BackgroundYin, H., Li, L., Wu, R. J., Wang, Y., & Li, A. (2020) · Building Simulation · doi:10.1007/s12273-020-0699-x · Cited by 35
Pereira, P. F., Ramos, N., & Ferreira, A. J. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107376 · Cited by 35
Respiratory performance of humans exposed to moderate levels of carbon dioxide
Mishra, A. K., Schiavon, S., Wargocki, P. L., & Tham, K. W. (2021) · Indoor Air · doi:10.1111/ina.12823 · Cited by 35
Liu, M., Nejat, P., Cao, P., Jimenez-Bescos, C., & Calautit, J. K. (2023) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2023.114048 · Cited by 36
TVOCs and PM 2.5 in Naturally Ventilated Homes: Three Case Studies in a Mild Climate
Fernández-Agüera, J., Domínguez-Amarillo, S., Fornaciari, M., & Orlandi, F. (2019) · Sustainability · doi:10.3390/su11226225 · Cited by 41
Valone, T. F. (2021) · Journal of Geoscience and Environment Protection · doi:10.4236/gep.2021.93007 · Cited by 82
Kuga, K., Ito, K., & Wargocki, P. L. (2021) · Indoor Air · doi:10.1111/ina.12852 · Cited by 38
A review of research on the impact of the classroom physical environment on schoolchildren's health
Fang, Y., Luo, X., & Lu, J. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.105430 · Cited by 55
An evaluation of HVAC energy usage and occupant comfort in religious facilities
Terrill, T. J., & Rasmussen, B. P. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.06.078 · Cited by 36
Carbon Dioxide Concentrations and Temperatures within Tour Buses under Real-Time Traffic Conditions
Chiu, C.-F., Chen, M., & Chang, F.-H. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125117 · Cited by 34
“However, using the AC system may reduce mileage by 5–25% [37], thus the need to reduce energy consumption provides an incentive for low rates of ventilation, leading to higher indoor CO2 concentrations [28].”
BackgroundPersonal CO2 bubble: Context-dependent variations and wearable sensors usability
Ghahramani, A., Pantelic, J., Vannucci, M., Pistore, L., Liu, S., Gilligan, B., Alyasin, S. S., Arens, E. A., Kampshire, K., & STERNBERG, E. M. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2018.11.015 · Cited by 33
“Recent studies have shown that increase in indoor CO2 concentration in indoor environments could negatively impact productivity and especially decision making [9, 10].”
Spatial seated occupancy detection in offices with a chair-based temperature sensor array
Wagner, D. N., Mathur, A., & Boor, B. E. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.107360 · Cited by 33
Davey, A. K., Gao, X., Xia, Y., Li, Z., Dods, M. N., DelaCruz, S., Pan, A., Swamy, S., Gardner, D. W., Carraro, C., et al. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130313 · Cited by 33
Feasibility of MOF-based carbon capture from indoor spaces as air revitalization system
Harrouz, J. P., Ghali, K., Hmadeh, M., Ghaddar, N., & Ghani, S. A. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111666 · Cited by 34
Farm education and the value of learning in an authentic learning environment
Smeds, P., Jeronen, E. K., & Kurppa, S. (2015) · Jukuri (Natural Resources Institute Finland (Luke)) · doi:10.12973/ijese.2015.251a · Cited by 78
Ilieș, A. B., Caciora, T. I., Marcu, F. M., BERDENOV, Z. G., Ilieș, G., Safarov, B., Hodor, N., Grama, V., Shomali, M. A., Ilieș, D. C., et al. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192416599 · Cited by 32
“A quantity of CO2 greater than 1000 ppm [60] can lead to headaches, drowsiness and even breathing problems in case of prolonged exposure [17,61].”
BackgroundCritical factors and thresholds for user satisfaction on air quality in office environments
Park, J., Loftness, V., Aziz, A., & Wang, T. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106310 · Cited by 32
Effects of Types of Horticultural Activity on the Physical and Mental State of Elderly Individuals
Tu, P.-C., Cheng, W.-C., Hou, P.-C., & Chang, Y.-S. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17145225 · Cited by 37
Air pollution effects on adult mortality rate in developing countries
Ahmad, N. A., Ismail, N. W., Sidique, S. F., & Mazlan, N. S. (2020) · Environmental Science and Pollution Research · doi:10.1007/s11356-020-11191-3 · Cited by 34
Liu, W., Tian, X., & Tao, M. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108431 · Cited by 34
Hattori, S., Iwamatsu, T., Miura, T., Tsutsumi, F., & Tanaka, N. (2022) · Sensors · doi:10.3390/s22197331 · Cited by 34
Cao, X., Li, P., Zhang, J., & Pang, L. (2022) · Atmosphere · doi:10.3390/atmos13060891 · Cited by 38
“The exposure to elevated pure CO 2 concentration could significantly reduce the SMS test performance starting at 1000 ppm [10,11].”
Kaushik, A. K., Arif, M., Syal, M., Rana, M. Q., Oladinrin, O. T., Sharif, A. A., & Alshdiefat, A. S. (2022) · Sustainability · doi:10.3390/su142315719 · Cited by 40
Rossi, A., Fabbri, B., Spagnoli, E., Gaiardo, A., Valt, M., Ferroni, M., Ardit, M., Krik, S., Pedrielli, A., Vanzetti, L., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c04789 · Cited by 34
Basner, M., Nasrini, J., Hermosillo, E., McGuire, S., Dinges, D. F., Moore, T. M., Gur, R. C., Rittweger, J., Mulder, E. R., Wittkowski, M., et al. (2018) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00855.2017 · Cited by 31
Kim, A. A., Wang, S., Kim, J.-E., & Reed, D. A. (2019) · Buildings · doi:10.3390/buildings9040094 · Cited by 33
“Carbon dioxide levels can be harmful to humans at concentrations above 2500 ppm [44].”
BackgroundBuitrago, N., Savdie, J., Almeida, S. M., & Verde, S. C. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.116062 · Cited by 32
Wu, J., Weng, J., Xia, B., Zhao, Y., & Song, Q. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18084109 · Cited by 37
“Satish et al. (2012) found that more than half of subjects appear to reduce decision-making performance at CO2 concentrations of 1000 ppm, relative to 600 ppm [26].”
Backgroundn-Gage: Predicting in-class Emotional, Behavioural and Cognitive Engagement in the WildPreprint
Gao, N., Shao, W., Rahaman, M. S., & Salim, F. D. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2007.04831 · Cited by 31
Human responses to high levels of carbon dioxide and air temperature
Tu, Z., Li, Y., Geng, S., Zhou, K., Wang, R., & Dong, X. M. (2020) · Indoor Air · doi:10.1111/ina.12769 · Cited by 31
Torriani, G., Torresin, S., Lara-Ibeas, I., Albatici, R., & Babich, F. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111645 · Cited by 42
“Among the former, we find diaries [62,63], interviews [63], sensory testing [23, 64], and text mining techniques [65], as well as questionnaires, which are employed in the vast majority of cases [21 – 23,23,25 – 36,38 – 43, 45 – 50,52 – 63,63 – 112].”
BackgroundJung, C., Hsu, N., & Su, H.-J. J. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106249 · Cited by 33
Motta, O., Pironti, C., Ricciardi, M., Rostagno, C., Bolzacchini, E., Ferrero, L., Cucciniello, R., & Proto, A. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-021-13741-9 · Cited by 28
“For good indoor air quality, carbon dioxide concentration should not exceed 1000 ppm to also avoid impairment to the health of people in indoor environments, such as “sick building syndrome” (SBS) symptoms (Satish et al. 2012).”
BackgroundAhmed, R., Mumovic, D., Bagkeris, E., & Ucci, M. (2022) · Indoor Air · doi:10.1111/ina.13004 · Cited by 36
Chen, D., Huebner, G. M., Bagkeris, E., Ucci, M., & Mumovic, D. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110967 · Cited by 33
“…three methods to control CO 2 levels in the studies: (1) injecting pure CO 2 : most studies which used this method were conducted in the chamber [14,19 – 26] and controlled laboratory environment [15,17], one in the office room [27] (2) manipulating the ventilation rates (Table S2,…”
InfluentialMitigating particulate matter exposure in naturally ventilated buildings during haze episodes
Tham, K. W., Parshetti, G. K., Balasubramanian, R., Sekhar, C., & Cheong, D. K. W. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.11.036 · Cited by 33
Tian, Z., Si, B., Wu, Y., Zhou, X., & Shi, X. (2019) · Building Simulation · doi:10.1007/s12273-019-0543-3 · Cited by 29
Matthaios, V. N., Kramer, L. J., Crilley, L. R., Sommariva, R., Pope, F. D., & Bloss, W. J. (2020) · Atmospheric Environment · doi:10.1016/j.atmosenv.2020.117810 · Cited by 29
Effects of head-down tilt bed rest plus elevated CO2 on cognitive performance
Basner, M., Stahn, A. C., Nasrini, J., Dinges, D. F., Moore, T. M., Gur, R. C., Mühl, C., Macias, B. R., & Laurie, S. S. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00865.2020 · Cited by 39
Creating Clean Air Spaces During Wildland Fire Smoke Episodes: Web Summit Summary
Davison, G., Barkjohn, K. K., Hagler, G. S. W., Holder, A. L., Coefield, S., Noonan, C. W., & Hassett-Sipple, B. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.508971 · Cited by 36
“If the fresh air intake is reduced, it is important to monitor PM and VOC concentrations, which may increase due to indoor sources (25, 26).”
BackgroundThe impact of emissions from an essential oil diffuser on cognitive performance
Du, B., Schwartz‐Narbonne, H., Tandoc, M. C., Heffernan, E., Mack, M. L., & Siegel, J. A. (2021) · Indoor Air · doi:10.1111/ina.12919 · Cited by 34
Detection of occupancy profile based on carbon dioxide concentration pattern matching
Szczurek, A., Maciejewska, M., Wyłomańska, A., Zimroz, R., Żak, G., & Dolega, A. (2016) · Measurement · doi:10.1016/j.measurement.2016.07.036 · Cited by 29
Investigating CO2 removal by Ca- and Mg-based sorbents with application to indoor air treatment
Gall, E. T., Sonat, C., Nazaroff, W. W., & Unluer, C. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.10.008 · Cited by 29
Impacts of school environment quality on autistic pupil's behaviours – A systematic review
Qutub, R. A., Luo, Z., Vasilikou, C., Tavassoli, T., Essah, E., & Marcham, H. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111981 · Cited by 42
“One study found that a slight increase in CO 2 levels from 600 to 1000 ppm negatively influenced cognitive performance [96].”
BackgroundChamber Studies on Nonvented Decorative Fireplaces Using Liquid or Gelled Ethanol Fuel
Schripp, T., Salthammer, T., Wientzek, S., & Wensing, M. (2014) · Environmental Science & Technology · doi:10.1021/es404972s · Cited by 28
Kaduwela, A. P., Kaduwela, A. P., Jrade, E., Brusseau, M., Morris, S., Morris, J., & Risk, V. (2019) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2019.1629362 · Cited by 29
“However, there is evidence that the attentional processes of students (Coley, Greeves, and Saxby 2007) and the decision-making performance (Satish et al. 2012) are inversely proportional to the CO2 levels.”
BackgroundQiu, Y., Wang, Y., & Ya, T. (2020) · Building Simulation · doi:10.1007/s12273-020-0663-9 · Cited by 28
Abdel-Salam, M. M. M. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108425 · Cited by 35
Nunayon, S. S., & Zhong, L. (2025) · Sustainable Cities and Society · doi:10.1016/j.scs.2025.106535 · Cited by 33
Is CO2 an Indoor Pollutant? Higher Levels of CO2 May Diminish Decision Making Performance
Fisk, W. J., Satish, U., Mendell, M. J., Hotchi, T., & Sullivan, D. P. (2013) · eScholarship (California Digital Library) · Cited by 27
Self-citationChang, T., Lin, Y.-S., & Hsu, Y.-T. (2022) · Atmospheric Environment · doi:10.1016/j.atmosenv.2022.119473 · Cited by 30
Investigation of indoor air quality in university residences using low-cost sensors
Afroz, R., Guo, X., Cheng, C.-W., Delorme, A., Duruisseau-Kuntz, R., & Zhao, R. (2023) · Environmental Science Atmospheres · doi:10.1039/d2ea00149g · Cited by 27
“27,28 Growing evidence shows that exposure to a CO 2 concentration of 500 – 5000 ppm can cause various physiological changes in circulatory and autonomic systems, and numerous unpleasant responses were also reported, including drowsiness, lethargy, stu ffi ness, and a feeling that the air is stale.”
BackgroundGall, E. T., & Nazaroff, W. W. (2015) · Atmospheric Environment · doi:10.1016/j.atmosenv.2015.01.004 · Cited by 29
Limitations and requirements for measuring metabolic rates: a mini review
Lighton, J. R. B. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2016.265 · Cited by 31
Ventilatory and integrated physiological responses to chronic hypercapnia in goats
Burgraff, N. J., Neumueller, S., Buchholz, K. J., Länger, T., Hodges, M. R., Pan, L., & Forster, H. V. (2018) · The Journal of Physiology · doi:10.1113/jp276666 · Cited by 29
“2012), and studies of CO2 stresses, such as studies of environmental medicine showing an association between elevated InCO2 and cognitive decline (Fothergill et al. 1991; Satish et al. 2012; Allen et al. 2016).”
BackgroundSørensen, S. B., & Kristensen, K. V. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111369 · Cited by 30
Young, A. S., Parikh, S., Dedesko, S., Bliss, M., Xu, J., Zanobetti, A., Miller, S. L., & Allen, J. G. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111551 · Cited by 34
Tahmasebi, F., Wang, Y., Cooper, E., Godoy-Shimizu, D., Stamp, S., & Mumovic, D. (2021) · Building Services Engineering Research and Technology · doi:10.1177/01436244211017786 · Cited by 28
Shum, C., Alipouri, Y., & Zhong, L. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108476 · Cited by 32
Indoor exposure of elderly to air pollutants in residential buildings in Alexandria, Egypt
Abdel-Salam, M. M. M. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109221 · Cited by 34
CO2 Concentrations and Thermal Comfort Analysis at Onsite and Online Educational Environments
Alegría-Sala, A., Tardío, E. C., Casals, L. C., Macarulla, M., & Salom, J. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192316039 · Cited by 26
“Apart from the negative impacts on health, high concentrations of CO2 levels present a drop in the speed of cognitive functions [23,24].”
BackgroundImpact of window views on cognitive functions and perceived comfort in healthcare environments
Elnaklah, R., & AlWaer, H. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112482 · Cited by 30
Wang, J., Park, Y. K., & Jo, Y. M. (2020) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.06.011 · Cited by 25
Larcombe, A. N., Papini, M. G., Chivers, E. K., Berry, L. J., Lucas, R. M., & Wyrwoll, C. S. (2021) · Environmental Health Perspectives · doi:10.1289/ehp7305 · Cited by 25
“…in a range of adverse health e ff ects, including in fl ammation (Schneberger et al. 2017; Thom et al. 2017a, 2017b) and cognitive impairment (Kajtár and Herczeg 2012; Satish et al. 2012; Allen et al. 2016; Snow et al. 2019), with some e ff ects manifesting after as little as a few hours of exposure.”
Alaidroos, A., Almaimani, A. K., Krarti, M., Dahlan, A. S., & Maddah, R. (2021) · Building Simulation · doi:10.1007/s12273-021-0854-z · Cited by 27
“It is worth noting that research evidences showed that average indoor CO2 concentration in buildings is generally below the critical values responsible for health risks; however, the observed indoor CO2 concentrations are known to have major impacts on occupant’s performance according to reported studies (Satish et al…”
BackgroundAs, M., & Bilir, T. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107792 · Cited by 25
IoT based indoor personal comfort levels monitoring
Ciabattoni, L., Ferracuti, F., Ippoliti, G., Longhi, S., & Turri, G. (2016) · International Conference on Consumer Electronics · doi:10.1109/icce.2016.7430548 · Cited by 26
“On the same time it is well known [10] that CO 2 has negative effects on human working performances.”
BackgroundCampbell, N., McGrath, T., Nanukuttan, S. V., & Brown, S. (2017) · Case Studies in Construction Materials · doi:10.1016/j.cscm.2017.07.002 · Cited by 25
“Other recent studies have shown that CO2 concentrations in excess of 1000 ppm have adverse effects on the decision making performance of individuals [33] and [34] recommends that maximum levels of CO2 should be 1350 ppm.”
BackgroundKapalo, P., Domniţa, F. V., Bacoţiu, C., & Podolak, M. (2018) · International Journal of Environmental Health Research · doi:10.1080/09603123.2018.1483010 · Cited by 25
“Satish et al. (2012) studied the performance reduction at a higher CO2 concentration inside a room.”
BackgroundReal time in-vehicle air quality monitoring using mobile sensing
Lohani, D., & Acharya, D. (2016) · IEEE India Conference · doi:10.1109/indicon.2016.7839099 · Cited by 24
“It has been researched and reported that high levels of CO2 can impact decision making abilities [6].”
BackgroundThe Study of Co2 Concentration in A Classroom During The Covid-19 Safety Measures
Zemītis, J., Bogdanovičs, R., & Bogdanovica, S. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202124601004 · Cited by 26
“Experiments carried out at the Lawrence Berkeley National Laboratory found out that a relationship between CO2 levels in the air and human thinking ability can be demonstrated [31].”
BackgroundAmine-Based Latex Coatings for Indoor Air CO2 Control in Commercial Buildings
Krishnamurthy, A., Salunkhe, B., Zore, A., Rownaghi, A. A., Schuman, T. P., & Rezaei, F. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02934 · Cited by 27
Research on risk scorecard of sick building syndrome based on machine learning
Fan, L., & Ding, Y. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108710 · Cited by 24
Building occupancy estimation using microwave Doppler radar and wavelet transform
Islam, S. M. M., Droitcour, A. D., Yavari, E., Lubecke, V. M., & Borić-Lubecke, O. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110233 · Cited by 27
Karaiskos, P., Munian, Y., Martínez-Molina, A., & Alamaniotis, M. (2024) · Smart and Sustainable Built Environment · doi:10.1108/sasbe-10-2023-0308 · Cited by 32
Health and Exposure to VOCs From Pinewood in Indoor Environments
Skulberg, K. R., Nyrud, A. Q., Goffeng, L. O., & Wisthaler, A. (2019) · Frontiers in Built Environment · doi:10.3389/fbuil.2019.00107 · Cited by 26
“An experimental study by Satish et al. (2012) revealed adverse effects of CO2 on various tests of decision-making performance.”
BackgroundManiscalco, J., Hoffmeyer, F., Monsé, C., Jettkant, B., Marek, E. M., Brüning, T., Bünger, J., & Sucker, K. (2021) · Indoor Air · doi:10.1111/ina.12939 · Cited by 28
Ulpiani, G., Nazarian, N., Zhang, F., & Pettit, C. J. (2021) · Frontiers in Environmental Science · doi:10.3389/fenvs.2021.725974 · Cited by 24
“, headaches, dizziness, vomit) soars when CO2 reaches 1,000 ppm (Loh and Andamon; Satish et al., 2012), which is the commonly accepted threshold for indoor CO2 concentration in literature and regulations (Daisey et al.”
Integration of Indoor Air Quality Prediction into Healthy Building Design
Shen, Y., Mahecha, S. D., Moreno, S. A., & Licina, D. (2022) · Sustainability · doi:10.3390/su14137890 · Cited by 27
Fohrmann, L. S., Petrov, A. Y., Lang, S., Jalas, D., Krauss, T. F., & Eich, M. (2015) · Optics Express · doi:10.1364/oe.23.027672 · Cited by 24
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.