Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 301–400 of 1,000
Advanced buffer materials for indoor air CO2control in commercial buildings
Rajan, P. E., Krishnamurthy, A., Morrison, G., & Rezaei, F. (2017) · Indoor Air · doi:10.1111/ina.12386 · Cited by 24
Jaffe, D. A., & Creekmore, A. (2024) · Atmospheric Environment · doi:10.1016/j.atmosenv.2024.120564 · Cited by 23
Ren, J., & Liu, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.12.047 · Cited by 22
Gupta, R., Howard, A., & Zahiri, S. (2019) · Building Services Engineering Research and Technology · doi:10.1177/0143624419891568 · Cited by 32
Abboushi, B., Safranek, S., Bermudez, E. R.-F., Pratoomratana, S., Chen, Y., Poplawski, M. E., & Davis, R. G. (2022) · Frontiers in Built Environment · doi:10.3389/fbuil.2022.787289 · Cited by 30
Althaus, P., Redder, F., Ubachukwu, E., Mork, M., Xhonneux, A., & Müller, D. (2022) · Applied Sciences · doi:10.3390/app12073305 · Cited by 28
Grimm, K., Niederer, D., Nienhaus, A., Groneberg, D. A., & Engeroff, T. (2022) · Scientific Reports · doi:10.1038/s41598-022-13711-2 · Cited by 22
Human personal air pollution clouds in a naturally ventilated office during the COVID-19 pandemic
Shen, Y., Muthalagu, A., Serrano, V. G., & Licina, D. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110280 · Cited by 22
Impact of VOCs on decision making and productivity
Satish, U., Cleckner, L. B., & Vasselli, J. (2013) · Intelligent Buildings International · doi:10.1080/17508975.2013.812956 · Cited by 26
“…multi-hour (∼2 hours per simulation) quasi-experimental simulation technique that has been repeatedly validated as a predictor of human performance and productivity in the real world (Breuer and Streufert 1995; Streufert et al. 1993; Satish and Streufert 1997, 2002; Satish et al. 2012, 2009, 2004).”
BackgroundSelf-citationA Ratiometric Readout Circuit for Thermal-Conductivity-Based Resistive CO2Sensors
Cai, Z., van Veldhoven, R. H. M., Falepin, A., Suy, H., Sterckx, E., Bitterlich, C., Makinwa, K. A. A., & Pertijs, M. A. P. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2587861 · Cited by 22
Neamtiu, I. A., Lin, S., Chen, M., Roba, C. A., Csobod, É., & Gurzau, E. S. (2019) · Environmental Monitoring and Assessment · doi:10.1007/s10661-019-7768-6 · Cited by 22
Gupta, R., Howard, A., & Zahiri, S. (2020) · Architectural Science Review · doi:10.1080/00038628.2019.1709788 · Cited by 26
“Studies found that higher ventilation rates/lower CO2 concentrations correlatedwith amore productiveworkforce (Allen et al. 2016; Federspiel et al. 2004; Kajtar, Herczeg, and Lang 2003; Park and Yoon 2011; Satish et al. 2012; Tham and Willem 2005; Wargocki et al. 1999).”
BackgroundImpact of Cognitive Tasks on CO2 and Isoprene Emissions from Humans
Gall, E. T., Mishra, A. K., Li, J., Schiavon, S., & Laguerre, A. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c03850 · Cited by 23
Platform for monitoring and analysis of air quality in environments with large circulation of people
Soares, P. H., Monteiro, J. P., Freitas, H. F., Sakiyama, R. Z., & Andrade, C. M. G. (2018) · Environmental Progress & Sustainable Energy · doi:10.1002/ep.12895 · Cited by 21
“However, studies show that from 600 ppm, even in a subtle way, the human being begins to feel the first effects of carbon dioxide in your body [21].”
BackgroundPositive Work: A Multidimensional Overview and Analysis of Work-Related Drivers of Wellbeing
Lomas, T. (2019) · International Journal of Applied Positive Psychology · doi:10.1007/s41042-019-00016-5 · Cited by 27
Gignac, F., Barrera‐Gómez, J., Persavento, C., Solé, C., Tena, È., López-Vicente, M., Foraster, M., Amato, F., Alástuey, A., Querol, X., et al. (2021) · Environment International · doi:10.1016/j.envint.2021.106614 · Cited by 25
Roskams, M., McNeely, E., Węziak‐Białowolska, D., & Białowolski, P. (2021) · Routledge eBooks · doi:10.1201/9781003128830-3 · Cited by 32
Manipulating polymer composition to create low-cost, high-fidelity sensors for indoor CO2 monitoring
Siefker, Z. A., Hodul, J. N., Zhao, X., Bajaj, N., Brayton, K. M., Flores‐Hansen, C., Zhao, W., Chiu, G. T. ‐., Braun, J. E., Rhoads, J. F., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-92181-4 · Cited by 21
A Practical and Adaptive Approach to Predicting Indoor CO2
Segala, G., Doriguzzi-Corin, R., Peroni, C., Gazzini, T., & Siracusa, D. (2021) · Applied Sciences · doi:10.3390/app112210771 · Cited by 21
Influence of indoor air quality on sleep quality of university students in Lisbon
Ramos, J., Belo, J., Silva, D., Diogo, C., Almeida, S. M., & Canha, N. (2021) · Atmospheric Pollution Research · doi:10.1016/j.apr.2021.101301 · Cited by 21
Review on Discrimination of Hazardous Gases by Smart Sensing Technology
Bandewad, G. W., Datta, K. P., Gawali, B. W., & Pawar, S. N. (2023) · Artificial Intelligence and Applications · doi:10.47852/bonviewaia3202434 · Cited by 42
Harrouz, J. P., Karam, J., Ghali, K., & Ghaddar, N. (2023) · Energy Conversion and Management · doi:10.1016/j.enconman.2023.117290 · Cited by 23
Run, K., Cévaër, F., & Dubé, J. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.107507 · Cited by 25
Assessing metabolic rate and indoor air quality with passive environmental sensors
Ruiz, I., Sprowls, M., Deng, Y. C., Kulick, D., Destaillats, H., & Forzani, E. (2018) · Journal of Breath Research · doi:10.1088/1752-7163/aaaec9 · Cited by 21
Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study
Stenson, J., Ishaq, S. L., Laguerre, A., Loia, A., MacCrone, G., Mugabo, I., Northcutt, D., Riggio, M., Barbosa, A. R., Gall, E. T., et al. (2019) · Buildings · doi:10.3390/buildings9060142 · Cited by 27
Assessment and improvement of indoor environmental quality in a primary school
Ekren, O., Karadeniz, Z. H., Atmaca, İ., Ugranli, T., Sofuoǧlu, S. C., & Toksoy, M. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1251288 · Cited by 27
“While CO2 has been considered as an indicator of air exchange, a recent study showed that it may be an indoor air pollutant (Satish et al. 2012).”
BackgroundJin, R. N., Inada, H., Négyesi, J., Ito, D., & Nagatomi, R. (2022) · Indoor Air · doi:10.1111/ina.13055 · Cited by 18
“15,17 However, the relationship between CO 2 concentration and exposure time on daytime sleepiness, which critically reduces office workers’ work efficiency, is still controversial.”
Wang, H., Wang, J., Feng, Z., Yu, C. W., & Cao, S. (2022) · Indoor and Built Environment · doi:10.1177/1420326x221108587 · Cited by 20
Ma, N., Chau, H.-W., Zhou, J. Z., & Noguchi, M. (2017) · Sustainability · doi:10.3390/su9122172 · Cited by 19
“(1) CO2 concentrations The elevated concentration of CO2 has been associated with negative impacts on human cognition and decision-making [26,27].”
BackgroundMa, F., Zhan, C., & Xu, X. (2019) · Energies · doi:10.3390/en12091602 · Cited by 22
Elaouzy, Y., & Zaabout, A. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112817 · Cited by 24
Context-aware IoT-enabled framework to analyse and predict indoor air quality
Rastogi, K., & Lohani, D. (2022) · Intelligent Systems with Applications · doi:10.1016/j.iswa.2022.200132 · Cited by 19
Enhanced ZIF-8-enabled colorimetric CO2 sensing through dye-precursor synthesis
Davey, A. K., Li, Z., Lefton, N. G., Leonhardt, B. E., Pourghaderi, A., McElhany, S., Popple, D., Dai, C., Kahn, S., Dods, M. N., et al. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132783 · Cited by 18
Yao, H., Shen, X., Wu, W., Lv, Y., Vishnupriya, V., Zhang, H., & Long, Z. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111347 · Cited by 19
Du, B., Reda, I., Licina, D., Kapsis, K., Qi, D., Candanedo, J. A., & Li, T. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.4c02797 · Cited by 19
Xue, T., Kang, N., & Zhu, T. (2024) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-071723-015722 · Cited by 21
Laverge, J., Delghust, M., & Janssens, A. (2015) · International Journal of Ventilation · doi:10.1080/14733315.2015.11684078 · Cited by 19
“A recent study, however, suggests that carbon dioxide in itself can also cause physiological reactions, reducing the decision making ability of test subjects (Satish et al. 2012, Streufert 1988).”
BackgroundIndoor living plants’ effects on an office environment
Smith, A. J., Fsadni, A. M., & Holt, G. D. (2017) · Facilities · doi:10.1108/f-09-2016-0088 · Cited by 28
Evaluation of relative weights for temperature, CO2, and noise in the aircraft cabin environment
Jia, S., Lai, D., Kang, J., Li, J., & Liu, J. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.009 · Cited by 19
Assessing and reducing fine and ultrafine particles inside Los Angeles taxis
Yu, N., Shu, S., Lin, Y., & Zhu, Y. (2018) · Atmospheric Environment · doi:10.1016/j.atmosenv.2018.03.023 · Cited by 19
Tam, C., Zhao, Y., Liao, Z., & Zhao, L. Y. (2020) · Buildings · doi:10.3390/buildings10070124 · Cited by 19
Zhao, X., Lou, Z., Shah, P. T., Wu, C., Liu, R., Xie, W. B., & Zhang, S. (2025) · Sensors · doi:10.3390/s25154858 · Cited by 22
“…demonstrate blunted circadian temperature rhythms, impaired thermoregulation, and heightened sensitivity to indoor air quality parameters including CO 2 and volatile organic compounds, with these factors interacting to influence mood through effects on sleep, activity, and social behavior [83,84].”
Liu, Z., Deng, Y., Ma, S., He, B., & Cao, G. (2020) · Building Simulation · doi:10.1007/s12273-020-0693-3 · Cited by 20
Ledins, P. M., Borsuk, A. M., Ciardullo, C., Hénaff, E., & Dyson, A. H. (2022) · Energy and Buildings · doi:10.1016/j.enbuild.2022.111913 · Cited by 21
“headaches, irritability, sleepiness [14,15], as well as heart rate variability, focus [16], cognitive function and the ability to perform tasks [17].”
BackgroundLongitudinal assessment of personal air pollution clouds in ten home and office environments
Serrano, V. G., & Licina, D. (2022) · Indoor Air · doi:10.1111/ina.12993 · Cited by 18
Duhirwe, P. N., Ngarambe, J., & Yun, G. Y. (2022) · Frontiers of Architectural Research · doi:10.1016/j.foar.2022.10.003 · Cited by 22
Yin, C., Li, H., Cha, Y., Zhang, S., Du, J., Li, Z., & Wu, Y. (2022) · Environmental Pollution · doi:10.1016/j.envpol.2022.120884 · Cited by 18
Ramírez, O., Hernández-Cuellar, B., & de la Rosa, J. D. (2023) · Urban Climate · doi:10.1016/j.uclim.2023.101694 · Cited by 18
Rizzo, K., Camilleri, M. A., Gatt, D., & Yousif, C. (2024) · Sustainability · doi:10.3390/su16020766 · Cited by 29
A longitudinal study of IAQ metrics and the efficacy of default HVAC ventilation
Varnosfaderani, M. P., Heydarian, A., & Jazizadeh, F. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111353 · Cited by 18
Balvís, E., Sampedro, Ó., Zaragoza, S., Paredes, Á., & Michinel, H. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.04.117 · Cited by 21
Interaction between plant species and substrate type in the removal of CO2 indoors
Gubb, C., Blanuša, T., Griffiths, A., & Pfrang, C. (2019) · Air Quality Atmosphere & Health · doi:10.1007/s11869-019-00736-2 · Cited by 21
Improving adherence and outcomes in diabetic patients
Joshi, R., Joshi, D., & Cheriyath, P. (2017) · Patient Preference and Adherence · doi:10.2147/ppa.s122490 · Cited by 20
Bustamante-Mora, A., Diéguez, M., Zegarra, M., Escobar, F., & Epuyao, G. (2025) · Sustainability · doi:10.3390/su17031071 · Cited by 35
Li, J., Xu, W., You, B., & Sun, Y. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108820 · Cited by 17
Ma, X., Liu, H., Zhang, Z., & Li, Y. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110189 · Cited by 24
Crosscutting of the pollutants and building ventilation systems: a literature review
Zuazua-Ros, A., Andrade, L. D. B., Dorregaray-Oyaregui, S., Martín-Gómez, C., Ramos, J. C., Manzueta, R., Sáiz-Esquerra, B. S., & Ariño, A. H. (2023) · Environmental Science and Pollution Research · doi:10.1007/s11356-023-27148-1 · Cited by 19
Shah, K. B., Kim, D., Pinakana, S. D., Hobosyan, M., Montes, A., & Raysoni, A. U. (2024) · Environments · doi:10.3390/environments11110237 · Cited by 23
“Several studies have also demonstrated that high levels of indoor CO 2 (500–5000 ppm) can cause headaches, drowsiness, lethargy, anxiety, and stuffiness, as well as memory loss and cognitive difficulties [42,43,45,46].”
Accumulation of metabolic carbon dioxide (CO2) in a vehicle cabin
Angelova, R. A., Markov, D. G., Симова, И., Величкова, Р., & Stankov, P. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/664/1/012010 · Cited by 17
Pereira, P. F., & Ramos, N. (2020) · Indoor and Built Environment · doi:10.1177/1420326x20960767 · Cited by 17
“Satish et al.(21) proposed the threshold of 2500 ppm for 2.”
BackgroundInfluentialLiu, Y., Zhao, M., Shao, Y., Yan, L., & Zhu, X. (2021) · World Journal of Surgical Oncology · doi:10.1186/s12957-021-02211-8 · Cited by 17
“And 250,000 ppm (a 25% concentration) can cause death[29].”
BackgroundEnergy taxes and economic growth in OECD countries: a simultaneous equations approach
Hassan, M., Oueslati, W., & Rousselière, D. (2021) · Journal of Environmental Economics and Policy · doi:10.1080/21606544.2021.1937326 · Cited by 18
“On the other side, Satish et al. (2012) evaluate the effects of increased CO2 concentrations on decision making.”
BackgroundLópez, M. J. R., Guyot, G., Golly, B., Ondarts, M., Würtz, F., & Gonze, E. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.103350 · Cited by 17
Carbon dioxide generation rates for children and adolescents
Wu, Y., Li, Y., Gao, S., Liu, S., Yin, H., & Zhai, Y. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110310 · Cited by 18
Occupant perceptions and a health outcome in retail stores
Zhao, M., Kim, Y., & Srebric, J. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.05.039 · Cited by 19
Bamrungwong, N., Vongmanee, V., & Rattanawong, W. (2020) · Sustainability · doi:10.3390/su12176994 · Cited by 16
Carbon dioxide in passenger cabins: Spatial temporal characteristics and 30‐year trends
He, J., Yin, Y., Yang, X., Pei, J., Sun, Y., Cui, X., & Chen, Q. (2021) · Indoor Air · doi:10.1111/ina.12874 · Cited by 16
Attaianese, E., Alfano, F. R. D., Palella, B. I., Pepe, D., & Vanacore, R. (2021) · Atmosphere · doi:10.3390/atmos12101272 · Cited by 18
Fernández-Agüera, J., Domínguez-Amarillo, S., Campano, M. Á., & Al-Khatri, H. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01239-3 · Cited by 17
Proxy methods for detection of inhalation exposure in simulated office environments
Yun, S., Zhong, S., Alavi, H. S., Alahi, A., & Licina, D. (2022) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-022-00495-w · Cited by 18
“, sneezing, irritated eyes, dry or itchy skin), impaired cognitive functioning and decision making [4, 5].”
Herbig, B., Norrefeldt, V., Mayer, F., Reichherzer, A., Lei, F., & Wargocki, P. L. (2022) · Environmental Research · doi:10.1016/j.envres.2022.114770 · Cited by 20
D’Alicandro, A. C., & Mauro, A. (2023) · Journal of Building Performance Simulation · doi:10.1080/19401493.2022.2163423 · Cited by 16
“In the range of 1000–10000 PPM (Particle PerMillion), it can create temporary inconvenient such as negative effects on cognitive abilities and concentrations (Satish et al. 2012), while at a concentration in the air higher than 25% can cause death due to asphyxia (Barberi et al. 1989).”
BackgroundShaer, I., & Shami, A. A. (2023) · IEEE Transactions on Network and Service Management · doi:10.1109/tnsm.2023.3278937 · Cited by 17
“As a result, a more informed HVAC control is obtained, which improves occupants’ comfort [14], curbs the spread of COVID-19 [15], and reduces energy consumption [16].”
BackgroundParametric simulations of hierarchical core–shell MOF materials for direct air capture
Lieber, A. R., Boone, P., He, Y., Steckel, J. A., Rosi, N. L., Wilmer, C. E., & Hornbostel, K. (2023) · Separation and Purification Technology · doi:10.1016/j.seppur.2023.124180 · Cited by 17
Triboelectric nanogenerator assisted synthesis and detection of chemical compounds
Tushar, S. I., Sayam, A., Uddin, M. M., Dip, T. M., Anik, H. R., Arin, M. R. A., & Sharma, S. (2023) · Journal of Materials Chemistry A · doi:10.1039/d3ta03572g · Cited by 17
Effectiveness of natural ventilation through single-sided window opening in air-conditioning rooms
Liu, X., Wang, H., Li, Z., Zhao, J., Li, C., & Xie, D. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114260 · Cited by 16
Xia, T., Raneses, J. M., Schmiesing, B., Garcia, R., Walding, A., DeMajo, R., Schulz, A. J., & Batterman, S. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1427116 · Cited by 17
CO2 Levels in Classrooms: What Actions to Take to Improve the Quality of Environments and Spaces
Settimo, G., Indinnimeo, L., Inglessis, M., Felice, M. D., Morlino, R., di Coste, A., Carriera, F., Fiore, C. D., & Avino, P. (2024) · Sustainability · doi:10.3390/su16198619 · Cited by 16
Facing disaster: the great challenges framework
Torres, P. (2018) · foresight · doi:10.1108/fs-04-2018-0040 · Cited by 17
“…“moderate” declines in cognitive performance on decision tasks when the ambient concentration of CO2 increased from 600 to 1,000 ppm, and an “astonishingly large” drop in performance from 1,000 to 2,500 ppm (Grossman 2016; see also Romm 2014; Satish et al. 2012; Allen et al. 2016; Torres 2017a).”
BackgroundBrown, H., Proulx, M. J., & Fraser, D. S. (2020) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.02261 · Cited by 20
Mahadevan, A. D., Hupfeld, K. E., Lee, J. K., Dios, Y. E. D., Kofman, I. S., Beltran, N. E., Mulder, E. R., Bloomberg, J. J., Mulavara, A. P., & Seidler, R. D. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.654906 · Cited by 20
“Declines in performance are often evident when people perform under dual as opposed to single task conditions (Schaefer and Schumacher, 2011).”
BackgroundSchneberger, D., DeVasure, J. M., Bailey, K. L., Romberger, D. J., & Wyatt, T. A. (2017) · Journal of Occupational Medicine and Toxicology · doi:10.1186/s12995-017-0155-8 · Cited by 16
“Given that elevation of other gasses in this environment showed potential to enhance lung inflammatory symptoms [18], that CO2 could alter response to dust extract exposures in bronchial epithelial cells [24] and that levels as low as 1000 ppm were capable of inducing changes in cognitive function [25], we hypothesize…”
BackgroundTowards reliable intelligent occupancy detection for smart building applications
Luppe, C., & Shabani, A. (2017) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2017.7946831 · Cited by 16
“One could also add other complementary sensors such as indoor air quality such as Volatile Organic Compound (VOC) or carbon dioxide (CO2) [8] that could react to human presence.”
BackgroundBTEX near real-time monitoring in two primary schools in La Rochelle, France
Lara-Ibeas, I., Trocquet, C., Nasreddine, R., Andrikopoulou, C., Person, V., Cormerais, B., Englaro, S., & Calvé, S. L. (2018) · Air Quality Atmosphere & Health · doi:10.1007/s11869-018-0611-3 · Cited by 17
Genetic Algorithm Design of MOF-based Gas Sensor Arrays for CO2-in-Air Sensing
Day, B. A., & Wilmer, C. E. (2020) · Sensors · doi:10.3390/s20030924 · Cited by 16
“And even in areas where CO2 is less likely to accumulate rapidly, there are concerns over its role as an indoor pollutant [8,20,21].”
BackgroundBartyzel, J., Zięba, D., Nęcki, J., & Zimnoch, M. (2020) · Sustainability · doi:10.3390/su12145600 · Cited by 18
Poza-Casado, I., Gil-Valverde, R., Meiss, A., & Padilla-Marcos, M. Á. (2021) · Sustainability · doi:10.3390/su13126875 · Cited by 15
“Harmless as it may be considered, a high concentration of CO2 can have a negative impact on the attention of the students, hindering academic achievement [19].”
BackgroundAn adsorption-based CO2 treatment unit for ultra-low fresh air HVAC system using solid amine
Chu, Y., Xu, P., Jia, Y., Lin, M., Peng, C., & Dou, Q. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111148 · Cited by 15
Meta-Analysis of the Effect of Ventilation on Intellectual Productivity
Kuramochi, H., Tsurumi, R., & Ishibashi, Y. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20085576 · Cited by 21
“In addition, several studies have indicated that levels of CO2 that pose no health risks, such as around 1000 ppm, can still have an impact on intellectual productivity [5,9].”
BackgroundAir quality in the car: How CO2 and body odor affect drivers' cognition and driving performance?
Wang, C., Lin, Y., Ptukhin, Y., & Liu, S. (2023) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2023.168785 · Cited by 18
European residential ventilation: Investigating the impact on health and energy demand
Belias, E., & Licina, D. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113839 · Cited by 18
Lesage, M., Chalet, D., Migaud, J., & Krautner, C. (2024) · Journal of Environmental Management · doi:10.1016/j.jenvman.2024.120861 · Cited by 21
Ballerini, V., Coccagna, M., Bisi, M., Volta, A., Droghetti, L., di Schio, E. R., Valdiserri, P., & Mazzacane, S. (2025) · Buildings · doi:10.3390/buildings15060869 · Cited by 16
Assessment of Interventions to Improve Air Quality in a Livestock Building
Anthony, T., Yang, A. Y.-J., & Peters, T. M. (2017) · Journal of Agricultural Safety and Health · doi:10.13031/jash.12426 · Cited by 15
“Significant declines in the cognitive ability of office workers were identified with CO2 exposures in the range of 945 to 2500 ppm (Satish et al., 2012; Allen et al., 2016).”
Natural Ventilation Characterization in a Classroom under Different Scenarios
Chillón, S. A., Millan, M., Aramendía, Í., Fernández‐Gámiz, U., Zulueta, E., & Mendaza-Sagastizabal, X. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18105425 · Cited by 15
“[22] realized that, at other times, the aim is just reducing energy consumption, which leads to low rates of ventilation.”
BackgroundSurface Plasmon Resonance Sensor of CO2 for Indoors and Outdoors
Perez-Ocon, F. D. A., Pozo, A. M., Cortina, J., & Rabaza, O. (2021) · Applied Sciences · doi:10.3390/app11156869 · Cited by 15
Şahin, Ç., Doğan, T. R., Yıldız, M., & Sofuoǧlu, S. C. (2022) · Indoor Air · doi:10.1111/ina.13068 · Cited by 21
Dynamics of carbon dioxide concentration in indoor air
Szczurek, A., Maciejewska, M., Połoczański, R., Teuerle, M., & Wyłomańska, A. (2014) · Stochastic Environmental Research and Risk Assessment · doi:10.1007/s00477-014-1009-x · Cited by 16
Schmidt, M. A., Goodwin, T. J., & Pelligra, R. (2016) · Metabolomics · doi:10.1007/s11306-015-0942-0 · Cited by 19
“…of nine scales of decision-making performance (basic activity, applied activity, task orientation, initiative, information usage, breadth of approach, and basic strategy) have shown to consistently decline with increasing CO2 concentrations in humans (overall p-values\0.001; Satish et al. 2012).”
BackgroundInfluentialSurprising Effects of CO2 Exposure on Decision Making
James, J. T. (2013) · International Conference on Environmental Systems (ICES) · doi:10.2514/6.2013-3463 · Cited by 15
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).