Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 401–500 of 1,000
Perception of Cabin Air Quality among Drivers and Passengers
Constantin, D., Mazilescu, C.-A., Nagi, M., Drăghici, A., & Mihartescu, A.-A. (2016) · Sustainability · doi:10.3390/su8090852 · Cited by 15
Ventilation, Indoor Air Quality, Health, and Productivity
Wargocki, P. L. (2016) · Human factors and ergonomics · doi:10.1201/9781315374000-4 · Cited by 24
An Internet of Things Framework to Forecast Indoor Air Quality Using Machine Learning
Rastogi, K., & Lohani, D. (2020) · Communications in computer and information science · doi:10.1007/978-981-15-4301-2_8 · Cited by 15
Modeling vehicle indoor air quality using sensor data analytics
Lohani, D., Barthwal, A., & Acharya, D. (2021) · Journal of Reliable Intelligent Environments · doi:10.1007/s40860-021-00137-2 · Cited by 15
Snow, S., Boyson, A., Felipe-King, M., Malik, O., Coutts, L. V., Noakes, C. J., Gough, H., Barlow, J. F., & schraefel, M. C. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/483750 · Cited by 17
Improving energy efficiency in office buildings through adaptive control of the indoor climate
Gunay, H. (2016) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2016-11523 · Cited by 22
“Recent research [189] identified that human decision-making progress may further improve at CO2 concentrations below the ASHRAE standard limit [77] of 1000 ppm.”
BackgroundFostering user’s awareness about indoor air quality through an IoT-enabled home garden system
Ceccarini, C., Chan, K. K., Lok, I. L., Tse, R. T., Tang, S.-K., & Prandi, C. (2021) · International Conference on Computer Communications and Networks (ICCCN) · doi:10.1109/icccn52240.2021.9522313 · Cited by 14
Tent versus Mask-On Acute Effects during Repeated-Sprint Training in Normobaric Hypoxia and Normoxia
Vasquez-Bonilla, A. A., Rojas‐Valverde, D., González-Custodio, A., Timón, R., & Olcina, G. J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10214879 · Cited by 17
“When exceeding 2000–5000 ppm of CO2, symptoms such as dizziness, tiredness, sleepiness, and headaches may be present, potentially altering human performance [35].”
BackgroundGuo, M., Yu, W., Sun, Y., Wang, L., Zhou, H., & Zhang, Y. (2023) · Indoor Air · doi:10.1155/2023/8298339 · Cited by 18
Hierarchical Modelling for CO2 Variation Prediction for HVAC System Operation
Shaer, I., & Shami, A. A. (2023) · Algorithms · doi:10.3390/a16050256 · Cited by 14
Investigation of Microclimate Parameter Assurance in Schools with Natural Ventilation Systems
Makaveckas, T., Bliūdžius, R., Alavočienė, S., Paukštys, V., & Brazionienė, I. (2023) · Buildings · doi:10.3390/buildings13071807 · Cited by 17
Prediction and Comparison of In-Vehicle CO2 Concentration Based on ARIMA and LSTM Models
Han, J., Lin, H., & Qin, Z. (2023) · Applied Sciences · doi:10.3390/app131910858 · Cited by 15
Wang, C., Yoo, S., Tanabe, S., & Ito, K. (2020) · Energy and Built Environment · doi:10.1016/j.enbenv.2020.04.011 · Cited by 14
Feng, Y., Zhang, Y., Ding, X., Fan, Y., & Ge, J. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110489 · Cited by 16
Szczepanik-Ścisło, N., & Ścisło, Ł. (2023) · Buildings · doi:10.3390/buildings13092125 · Cited by 14
Indoor Air Quality in Chemical Laboratories
Ugranli, T., Gungormus, E., Sofuoǧlu, A., & Sofuoǧlu, S. C. (2016) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2016.04.007 · Cited by 17
Loftness, V., Hartkopf, V., Aziz, A., Choi, J.-H., & Park, J. (2017) · Springer eBooks · doi:10.1007/978-3-319-56862-1_3 · Cited by 14
A cross-disciplinary path to healthy and energy efficient buildings
Lex, S. W., Calì, D., Rasmussen, M. K., Bacher, P., Bachalarz, M., & Madsen, H. (2018) · Technological Forecasting and Social Change · doi:10.1016/j.techfore.2018.07.023 · Cited by 15
de Jode, M. L. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100030 · Cited by 13
“…evidence that levels of CO 2 below 5000 ppm induced any acute health symptoms and the evidence for cognitive impairment at moderate CO 2 levels was inconsistent, although evidence existed that decision making may be affected by CO 2 levels as low as 1000 ppm [4] but further research was needed.”
Predictive Analysis of In-Vehicle Air Quality Monitoring System Using Deep Learning Technique
Sukor, A. S. A., Cheik, G. C., Kamarudin, L. M., Mao, X., Nishizaki, H., Zakaria, A., & Zakaria, S. M. M. S. (2022) · Atmosphere · doi:10.3390/atmos13101587 · Cited by 13
“Ref.[19] reported that seven out of nine cognitive function domains could be affected by the increase of CO2 concentration in the vehicle cabin.”
BackgroundKlausen, F. B., Amidi, A., Kjærgaard, S. K., Schlünssen, V., Ravn, P., Østergaard, K., Gutzke, V. H., Glasius, M., Grønborg, T. K., Hansen, S. N., et al. (2023) · International Journal of Occupational Medicine and Environmental Health · doi:10.13075/ijomeh.1896.02032 · Cited by 16
Rawat, N., & Kumar, P. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.108813 · Cited by 18
Bie, H., Guo, B., Li, T., & Loftness, V. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.115389 · Cited by 16
Asere, L., Mols, T., & Blumberga, A. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.09.009 · Cited by 13
Popa, C., Petrus, M., & Bratu, A. (2022) · Molecules · doi:10.3390/molecules27113618 · Cited by 13
“Satish et al. 2012 [40] suggested in their study that even moderately elevated CO2 concentrations (approximately 2500 ppm) have the potential to affect decision-making.”
BackgroundAssessment of Indoor Air Quality in Renovated Buildings of Liepāja Municipality
Asere, L., Mols, T., & Blumberga, A. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.06.257 · Cited by 12
Xia, Y., Shikii, S., & Shimomura, Y. (2020) · Ergonomics · doi:10.1080/00140139.2020.1784466 · Cited by 13
Indoor Climate Performance in a Renovated School Building
Mocová, P., & Mohelníková, J. (2021) · Energies · doi:10.3390/en14102827 · Cited by 15
“The symptoms assessed for the syndrome are related to respiratory tract problems, headache, fatigue and difficulty concentrating [5,6].”
BackgroundGrygierek, K., & Ferdyn-Grygierek, J. (2022) · Energies · doi:10.3390/en15228456 · Cited by 12
Physiology or Psychology: What Drives Human Emissions of Carbon Dioxide and Ammonia?
Shen, Y., Bekö, G., Wargocki, P. L., Zhang, M., Merizak, M., Nenes, A., Williams, J., & Licina, D. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c07659 · Cited by 16
Gamification for air quality education: A systematic literature review
Daemei, A. B., Lovreglio, R., Feng, Z., Paes, D., & Miller, C. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112526 · Cited by 21
Cheung, H. Y. W., Kumar, P., Hama, S. M. L., Emygdio, A. P. M., Wei, Y., Anagnostopoulos, L., Ewer, J., Ferracci, V., Galea, E. R., Grandison, A., et al. (2025) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2024.178286 · Cited by 15
The influence of temperature and interior ambient lighting color on nighttime driving performance
Wang, C., Elson, J., Lin, Y., & Liu, S. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112815 · Cited by 13
Terracciano, A. C., Thurmond, K., Villar, M., Urso, J. J., Ninnemann, E. M., Parupalli, A., Loparo, Z. E., Demidovich, N., Kapat, J. S., Partridge, W. P., et al. (2018) · New Space · doi:10.1089/space.2017.0044 · Cited by 13
“Even chemically inert gases such as carbon dioxide (CO2), at concentrations below asphyxiating limits, can pose an indirect risk to humans by reducing cognitive performance.(7) Although the total list of gases hazardous to spacecraft operation is extensive, Table 1 lists gaseous species and various volatile organics o…”
Wyrwoll, C. S., Papini, M. G., Chivers, E. K., Yuan, J., Pavlos, N. J., Lucas, R. M., Bierwirth, P. N., & Larcombe, A. N. (2021) · The Journal of Physiology · doi:10.1113/jp282179 · Cited by 12
“Exposure to CO2 levels of 950–2000 ppm (compared to 600 ppm) for periods of 2.5–8 h was associated with reduced cognitive function scores (Satish et al. 2012; Allen et al. 2016).”
BackgroundInfluentialMonitoring and Analysis of Outdoor Carbon Dioxide Concentration by Autonomous Sensors
Soares, P. H., Monteiro, J. P., de Freitas, H. F. S., Ogiboski, L., Vieira, F. S., & Andrade, C. M. G. (2022) · Atmosphere · doi:10.3390/atmos13020358 · Cited by 12
Beard, J. D., Thygerson, S. M., Olivares, A., Tadje, J. E., Willis, S. E., & Johnston, J. D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191912431 · Cited by 13
“Concentrations as low as 800 ppm can increase heart rate, blood pressure, and cardiac output and stimulate ventilation and other respiratory symptoms while concentrations from 1000–2500 ppm can lead to significantly reduced cognitive performance [30,31].”
BackgroundFan, G., Xie, J., & Liu, J. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.377 · Cited by 13
Influence of common lighting conditions and time-of-day on the effort-related cardiac response
Zauner, J., Plischke, H., Stijnen, H., Schwarz, U. T., & Strasburger, H. (2020) · PLoS ONE · doi:10.1371/journal.pone.0239553 · Cited by 13
“Room-temperature and carbon-dioxide levels have the potential to influence performance [67, 68], and therefore, likely, also the experienced task demand and the cardiac reaction.”
BackgroundLiu, X., Chen, X., Zhang, J., & Liu, L. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116326 · Cited by 14
A Review of Cognitive and Behavioral Effects of Increased Carbon Dioxide Exposure in Humans
Stanković, A., Alexander, D. J., Oman, C. M., & Schneiderman, J. S. (2016) · Cited by 11
Kim, S. H., & Moon, H. J. (2023) · Buildings · doi:10.3390/buildings13123062 · Cited by 12
Zhang, D., Zhang, L., & Zhang, Y. (2024) · Journal of Building Engineering · doi:10.1016/j.jobe.2024.109422 · Cited by 21
Impact of partial regeneration method on the reduction of CO2 desorption energy
Kim, H. S., Xu, R., Kim, S., Kim, M., Koh, Y., Kim, K., Kim, J., Wee, H., & Kang, Y. T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.158300 · Cited by 11
A Survey on Sensor-Based Techniques for Continuous Stress Monitoring in Knowledge Work Environments
Kallio, J., Vildjiounaite, E., Tervonen, J., & López, M. B. (2025) · ACM Transactions on Computing for Healthcare · doi:10.1145/3720551 · Cited by 20
“Furthermore, reviews have highlighted the use of precise sensors like heart rate, ECG, and GSR in industrial contexts, emphasizing both the potential and challenges of real-time stress monitoring [51].”
Kalamees, T., Väli, A., Kallavus, U., Kurik, L., & Alev, Ü. (2015) · International Journal of Ventilation · doi:10.1080/14733315.2015.11684077 · Cited by 16
“According to Satish et al. (2012), relative to 600 ppm, at 1000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance.”
BackgroundKlimatyczne ABC. Interdyscyplinarne podstawy współczesnej wiedzy o zmianie klimatu
Bohdanowicz, Z., Budziszewska, M., Gajda, P., Giergiczny, M., Jȩdrak, J., Kardas, A. E., Kotowski, W., Łopaciuk-Gonczaryk, B., Malinowski, S., Mikulski, A., et al. (2021) · Wydawnictwa Uniwersytetu Warszawskiego eBooks · doi:10.31338/uw.9788323547303 · Cited by 19
Irawan, D. A., & Sari, P. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/729/1/012126 · Cited by 20
Neuroplasticity as a Foundation for Decision-Making in Space
Rappaport, M. B., & Corbally, C. J. (2022) · NeuroSci · doi:10.3390/neurosci3030033 · Cited by 12
Kanama, N., Ondarts, M., Guyot, G., Outin, J., Golly, B., & Gonze, E. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.106529 · Cited by 12
Faubel, C., Martínez-Molina, A., & Suk, J. Y. (2023) · Journal of Building Engineering · doi:10.1016/j.jobe.2023.108289 · Cited by 12
Cognitive functions and human error
Kanki, B. G. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-101869-9.00002-9 · Cited by 20
Huttunen, K. (2018) · Springer eBooks · doi:10.1007/978-3-319-62731-1_7 · Cited by 20
Keeping Doors Closed as One Reason for Fatigue in Teenagers—A Case Study
Mainka, A., & Zajusz-Zubek, E. (2019) · Applied Sciences · doi:10.3390/app9173533 · Cited by 11
The Deployment of a LoRaWAN-Based IoT Air Quality Sensor Network for Public Good
Howerton, J. M., & Schenck, B. L. (2020) · Systems and Information Engineering Design Symposium · doi:10.1109/sieds49339.2020.9106676 · Cited by 17
“In addition to its impact on global warming, even moderate levels of CO2 have an impact on cognitive performance, thus presenting us with an important opportunity and responsibility to change our behavior [10].”
BackgroundDeng, X., & Gong, G. (2020) · Journal of Environmental Sciences · doi:10.1016/j.jes.2020.06.025 · Cited by 14
Chemical space mapping for multicomponent gas mixtures
Kotliar-Shapirov, A., Fedorov, F. S., Ouerdane, H., Evlashin, S. A., Nasibulin, A. G., & Stevenson, K. J. (2021) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2021.115472 · Cited by 11
Indoor Coal Combustion for Heating Exacerbates CO2 Exposure Approaching Harmful Levels
Li, Y., Liu, X., Men, Y., Luo, Z., Xiong, R., Li, J., Cheng, H., Tao, S., & Shen, G. (2021) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.1c00650 · Cited by 11
Brain Fog: Does Air Pollution Make Us Less Productive?
Schmidt, S. (2019) · Environmental Health Perspectives · doi:10.1289/ehp4869 · Cited by 13
Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review
Chen, Y., Hu, Y., Lin, G., Zhang, Y., Ye, S., & Shen, B. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.113609 · Cited by 13
Membrane system for management and utilization of indoor CO2
Yoo, S. Y., Kim, Y. J., Lee, T. H., Lee, B. K., Kim, M. J., Han, S. H., Ha, S. Y., & Park, H. B. (2023) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2023.02.018 · Cited by 10
Xie, Z., Wang, Q., Zhou, K., Ma, L., Wang, J., Li, Y., Chen, S., & Wei, W. (2024) · Indoor Air · doi:10.1155/2024/5781565 · Cited by 12
Environmental data monitoring and infection risks in UK care-homes in the context of COVID-19
Khaliq, K. A., Mohamad, S., Edwards, A. J., Noakes, C. J., Kemp, A. H., Thompson, C. A., McGill, G., & Sharpe, T. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111174 · Cited by 10
Sun, R., Schiavon, S., Brager, G. S., Yan, H., & Parkinson, T. (2025) · Indoor Environments · doi:10.1016/j.indenv.2025.100080 · Cited by 16
Carbon dioxide as a pollutant: the risks on human health and the stability of the biosphere
Bardi, U., Bierwirth, P. N., Huang, K., & McIntyre, J. (2025) · Environmental Science Advances · doi:10.1039/d5va00017c · Cited by 25
Wang, F., Xu, H., Lei, T., Xu, Y., Wang, H., & Wang, L. (2025) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00108.2025 · Cited by 12
Home is where the health is: New Zealand responses to a “healthy” housing crisis
Ade, R., & Rehm, M. (2020) · Pacific Rim Property Research Journal · doi:10.1080/14445921.2020.1808278 · Cited by 15
“However researchers like Satish et al. (2012) have also determined that CO 2 itself may be a pollutant, rather than just an indicator of ventilation rates with Strøm-Tejsen, Zukowska, Wargocki, and Wyon (2016) determining that sleep quality and subsequent ability to concentrate and performance the…”
BackgroundLim, S., Mudway, I., Molden, N., Holland, J. A., & Barratt, B. (2021) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2021.152521 · Cited by 10
Chou, Y.-A., Wang, Z.-Y., Chang, H.-C., Liu, Y.-C., Su, P., Huang, Y., Yang, C., & Lai, C. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1052452 · Cited by 15
“Moderate concentrations of indoor CO2 are associated with changes in human performance and decision-making ability (13).”
BackgroundZand, M. S., Spallina, S., Ross, A., Zandi, K., Pawlowski, A., Seplaki, C. L., Herington, J., Corbett, A. M., Kaukeinen, K. A., Holden‐Wiltse, J., et al. (2024) · PLoS ONE · doi:10.1371/journal.pone.0291840 · Cited by 12
“…SARS-CoV-2 infections and room ventilation in an IDD school, elevated CO 2 concentrations on their own may decrease cognitive task performance [37, 39–42, 59] , concentration concentration [ 60 ], This study also highlights the potential trade-offs in terms of improving in-line filtration and…”
InfluentialLedins, P. M., Bhattacharya, C., Dyson, A. H., & Hénaff, E. (2024) · Research Directions Biotechnology Design · doi:10.1017/btd.2024.4 · Cited by 11
“Poor indoor air quality (IAQ) has measurable impacts to human health as levels of carbon dioxide (CO 2 ) (Jacobson et al. 2019; Satish et al. 2012; Vehvilainen et al. 2016), volatile organic compounds (VOCs) (Ataei et al. 2023; Halios et al. 2022) and other pollutants (Kumar et al. 2023) increase.”
BackgroundA Phase-Domain Readout Circuit for a CMOS-Compatible Hot-Wire CO2Sensor
Cai, Z., van Veldhoven, R., Suy, H., de Graaf, G., Makinwa, K. A. A., & Pertijs, M. A. P. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2866374 · Cited by 12
“Adverse effects on human productivity have been reported for average CO2 concentrations as low as 1000 ppm [2], [3].”
BackgroundHärkönen, K., Hannola, L., Lassila, J., & Luoranen, M. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.103460 · Cited by 14
Ye, W., Won, D., & Zhang, X. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.09.017 · Cited by 10
Kalema, T., & Viot, M. (2013) · Indoor Air · doi:10.1111/ina.12059 · Cited by 10
Salvatori, E., Gentile, C., Altieri, A., Aramini, F., & Manes, F. (2020) · Sustainability · doi:10.3390/su12020565 · Cited by 11
Carbon Dioxide Monitoring inside an Australian Brewery Using an Internet-of-Things Sensor Network
Hawchar, A., Ould, S., & Bennett, N. S. (2022) · Sensors · doi:10.3390/s22249752 · Cited by 9
Akamatsu, N., Sugano, S., Amada, K., Tomita, N., Iwaizumi, H., Takeda, Y., Wargocki, P. L., Olesen, B. W., & Tanabe, S. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.111540 · Cited by 9
“Several other studies have also established this relationship[6,7].”
BackgroundRasheed, E. O., Wang, K., Hashemi, A. R., Mahmoodi, M., & Panchalingam, K. (2024) · Buildings · doi:10.3390/buildings14072095 · Cited by 14
Kraakman, N. J. R., González-Martín, J., Garcia, C. S., Cantera, S., Lebrero, R., & Muñoz, R. (2024) · Journal of environmental chemical engineering · doi:10.1016/j.jece.2024.113695 · Cited by 9
Assessments and application of low-cost sensors to study indoor air quality in layer facilities
Afroz, R., Guo, X., Cheng, C.-W., Omar, S., Carney, V. L., Zuidhof, M. J., & Zhao, R. (2024) · Environmental Technology & Innovation · doi:10.1016/j.eti.2024.103773 · Cited by 9
Effect of Indoor Air Quality on Respiratory Health of Children: An MPPD Model Approach
Shukla, A., Indaliya, R., & Tandel, B. N. (2024) · Aerosol Science and Engineering · doi:10.1007/s41810-024-00253-5 · Cited by 9
“Prolonged exposure to elevated CO 2 levels can negatively impact cognitive function and cause discomfort (Satish and Mendell 2012).”
Dedesko, S., Pendleton, J., Petrov, J., Coull, B. A., Spengler, J. D., & Allen, J. G. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112531 · Cited by 11
Cui, X., Cui, X., Zhu, Q., Yin, S., Shi, X., Zhang, L., Yu, B., Hong, Y., & Chen, W. (2025) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2025.137329 · Cited by 9
Meselhy, A., & Almalkawi, A. (2025) · npj Clean Energy · doi:10.1038/s44406-025-00002-8 · Cited by 9
Toghraei, A., & Romanić, D. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113335 · Cited by 11
Zheng, J., Guo, X., Hu, S., Wu, F., Lao, C., Ma, H., Liu, R., & Xu, G. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111760 · Cited by 9
Fath, A., Hanna, N., Liu, Y., Tanch, S., Xia, T., & Huston, D. R. (2024) · Future Internet · doi:10.3390/fi16050170 · Cited by 9
Perry, J. L., Sargusingh, M., & Toomarian, N. B. (2016) · AIAA SPACE 2016 · doi:10.2514/6.2016-5461 · Cited by 9
Indoor air quality and thermal comfort for elderly residents in Houston TX—a case study
Baniassadi, A., Sailor, D. J., & O’Lenick, C. R. (2018) · Healthy, Intelligent and Resilient Buildings and Urban Environments · doi:10.14305/ibpc.2018.ie-2.04 · Cited by 11
“For example, exposure to moderate to high levels of carbon dioxide (CO2), with its welldocumented negative impacts on cognitive function (Allen et al., 2016; Satish et al., 2012), may be more detrimental to the elderly than other age groups.”
BackgroundBrdarić, D., Capak, K., Gvozdić, V., Barišin, A., Jelinić, J. D., Egorov, A. I., Šapina, M., Kalambura, S., & Kramarić, K. (2019) · Archives of Industrial Hygiene and Toxicology · doi:10.2478/aiht-2019-70-3343 · Cited by 12
“(13) found that cognitive performance was slightly worse at CO2 concentrations of 1938 mg/m 3”
BackgroundApriesnig, J. L., Manning, D. T., Suter, J. F., Magzamen, S. L., & Cross, J. E. (2020) · Energy Policy · doi:10.1016/j.enpol.2020.111859 · Cited by 11
Environmental Monitoring of PM2.5 and CO2 in Indoor Office Spaces of Delhi, India
Gupta, A., Goyal, R., Kulshreshtha, P., & Jain, A. (2020) · Lecture notes in civil engineering · doi:10.1007/978-981-15-1334-3_8 · Cited by 11
Characterizing Indoor Air Quality Performance Using a Graphical Approach
Teichman, K. Y., Howard-Reed, C., Persily, A. K., & Emmerich, S. J. (2016) · doi:10.6028/nist.tn.1868 · Cited by 9
“[10] suggests indoor CO2 levels may directly impact occupant decision making, meriting more research on this topic.”
BackgroundSun, Y., Marasinghe, S. A., Hou, J., Wang, P., Zhang, Q., & Sundell, J. (2024) · Environment International · doi:10.1016/j.envint.2024.108825 · Cited by 10
Assessing the hidden dangers of volcanic CO2 exposure: a critical review of health impacts
Boada, L. D., Simbaña‐Rivera, K., Rodríguez-Pérez, C., Fuentes, M. E., Henríquez‐Hernández, L. A., López-Villarrubia, E., & Álvarez-León, E. E. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1465837 · Cited by 8
A longitudinal field study of sensor-driven occupancy-centric HVAC controls in an office building
Pang, Z., Guo, M., O’Neill, Z. D., Smith-Cortez, B., Yang, Z., & Dong, B. (2025) · Energy and Buildings · doi:10.1016/j.enbuild.2025.116693 · Cited by 8
Exposures in Indoor Air Affecting Health
Hartiala, M., Elenius, V., Pesquera, A. A., Androulakis, S., Annesi‐Maesano, I., Badyda, A. J., Brandsma, S. H., Chatziprodromidou, I. P., Gajski, G., García‐Aymerich, J., et al. (2025) · Allergy · doi:10.1111/all.70179 · Cited by 16
“Elevated CO 2 concentrations (> 1000 ppm) can cause symptoms such as headaches, dizziness, fatigue, and impaired cognitive function [22].”
Lee, Y.-K., Kim, Y., & Lee, W. (2022) · Energies · doi:10.3390/en15093232 · Cited by 8
Microclimate Assessment in a 19th‐Century Heritage Building From Romania
Caciora, T. I., Ilieș, D. C., Costea, M., Blaga, L., BERDENOV, Z. G., Ilieș, A. B., Hassan, T. H., Pereș, A. C., Safarov, B., Josan, I., et al. (2024) · Indoor Air · doi:10.1155/2024/2989136 · Cited by 8
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.