Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Associations of higher indoor carbon dioxide (CO2) concentrations with impaired work performance, increased health symptoms, and poorer perceived air quality have been attributed to correlation of indoor CO2 with concentrations of other indoor air pollutants that are also influenced by rates of outdoor-air ventilation. Objectives: We assessed direct effects of increased CO2, within the range of indoor concentrations, on decision making. Methods: Twenty-two participants were exposed to CO2 at 600, 1,000, and 2,500 ppm in an office-like chamber, in six groups. Each group was exposed to these conditions in three 2.5-hr sessions, all on 1 day, with exposure order balanced across groups. At 600 ppm, CO2 came from outdoor air and participants’ respiration. Higher concentrations were achieved by injecting ultrapure CO2. Ventilation rate and temperature were constant. Under each condition, participants completed a computer-based test of decision-making performance as well as questionnaires on health symptoms and perceived air quality. Participants and the person administering the decision-making test were blinded to CO2 level. Data were analyzed with analysis of variance models. Results: Relative to 600 ppm, at 1,000 ppm CO2, moderate and statistically significant decrements occurred in six of nine scales of decision-making performance. At 2,500 ppm, large and statistically significant reductions occurred in seven scales of decision-making performance (raw score ratios, 0.06–0.56), but performance on the focused activity scale increased. Conclusions: Direct adverse effects of CO2 on human performance may be economically important and may limit energy-saving reductions in outdoor air ventilation per person in buildings. Confirmation of these findings is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Low ventilation rates and CO2 concentrations normally found in office buildings (approximately 1,000 ppm) have been recently associated with impairment in multiple domains of high-order cognitive function [45,46].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [45]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Self-citationWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462
Self-citationCarbon Dioxide and the Cerebral Circulation
Brian, J. E. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00029 · Cited by 395
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Behavior in the complex environment.
Streufert, S., & Streufert, S. C. (1978) · Cited by 302
Self-citationPhysiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
Roberge, R. J., Coca, A., Williams, W. J., Powell, J. B., & Palmiero, A. J. (2010) · Respiratory Care · doi:10.4187/respcare.10550569 · Cited by 276
Woods, S. W. (1988) · Archives of General Psychiatry · doi:10.1001/archpsyc.1988.01800250051007 · Cited by 265 · cited 2×
“Inhaled CO2 at concentrations of tens of thousands of ppm has been associated with changes in respiration, cerebral blood flow, cardiac output, and anxiety (Brian Jr 1998; Kaye et al. 2004; Lipsett et al. 1994; Roberge et al. 2010; Woods et al. 1988).”
BackgroundErdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · cited 1×
“…perceptions of poor air quality, increased prevalence of acute health symptoms (e.g., headache, mucosal irritation), slower work performance, and increased absence (Erdmann and Apte 2004; Federspiel et al. 2004; Milton et al. 2000; Seppanen et al. 1999; Shendell et al. 2004; Wargocki et al. 2000).”
BackgroundKaye, J., Buchanan, F., Kendrick, A. H., Johnson, P. L., Lowry, C. A., Bailey, J., Nutt, D., & Lightman, S. L. (2004) · Journal of Neuroendocrinology · doi:10.1111/j.0953-8194.2004.01158.x · Cited by 134 · cited 2×
“CO2 is the key regulator of respiration and arousal of behavioral states in humans (Kaye et al. 2004).”
Background
Research works printed but not linked: 7
- ACGIH (American Conference of Governmental Industrial Hygienists), 2011, TLVs and BEIs
- Corsi, 2002, Carbon dioxide levels and dynamics in elementary schools: results of the TESIAS Study. In: Indoor Air 2002, 9th International Conference on Indoor Air Quality and Climate (Levin H, ed)
- Knibbs, 2008, On-road quantification of the key characteristics of automobile HVAC systems in relation to in-cabin submicrometer particle pollution [Abstract]. In: 11th International Conference on Indoor Air Quality and Climate: Indoor Air 2008. Copenhagen, Denmark.
- Mudarri, 1997, Potential correction factors for interpreting CO2 measurements in buildings., ASHRAE Transactions, 103, 244
- Persily, 1997, Evaluating building IAQ and ventilation with carbon dioxide., ASHRAE Transactions, 103, 193
- Satish, 2009, Novel assessment of psychiatry residents: SMS simulations. Accreditation Council for Graduate Medical Education (ACGME) Bulletin, 18–23 January.
- Swezey, 1998, Preliminary development of a computer-based team performance assessment simulation., Int J Cogn Ergonomics, 2, 163
Cited by
Items 601–700 of 1,000
Luchnikov, I. A., Métivier, D., Ouerdane, H., & Chertkov, M. (2021) · Applied Energy · doi:10.1016/j.apenergy.2020.116419 · Cited by 9
Zin, M., Ismail, S. N. S., & Karuppiah, K. (2016) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 5
CO2 MEASUREMENTS FOR UNCONVENTIONAL MANAGEMENT OF INDOOR AIR QUALITY
Ragazzi, M., Albatici, R., Schiavon, M., Ferronato, N., & Torretta, V. (2019) · WIT transactions on ecology and the environment · doi:10.2495/air190271 · Cited by 5
Indoor Air Quality and Wellbeing - Enabling Awareness and Sensitivity with Ambient IoT Displays
Seiderer, A., Aslan, I., Dang, C. T., & André, E. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-34255-5_18 · Cited by 5
Indoor Air Quality and Academic PerformancePreprint
Stafford, T. M. (2013) · SSRN Electronic Journal · doi:10.2139/ssrn.2339850 · Cited by 5
“In addition, while indoor CO2 concentrations are typically interesting because they correlate well with the prevalence of other indoor pollutants, recent evidence suggests that CO2, in and of itself, may negatively affect performance (Satish et al., 2012).”
Fossil fuel combustion is driving indoor CO2 toward levels harmful to human cognitionPreprint
Karnauskas, K. B., Miller, S. L., & Schapiro, A. C. (2019) · EarthArXiv (California Digital Library) · doi:10.31223/osf.io/b8umq · Cited by 5
Yang, F., Ma, J., & Chen, L. (2023) · ChemistrySelect · doi:10.1002/slct.202203314 · Cited by 4
Ezeamii, V. C., Egbuchiem, A. N., Obianyo, C. M., Nwoke, P., & Obioma, L. O. (2025) · Cureus · doi:10.7759/cureus.83306 · Cited by 4
“Elevated CO₂ levels can lead to hypercapnia, reducing cerebral oxygenation and impairing neuronal function [25].”
Bioinspired Iontronic Gas Sensor for Selective CO 2 Sensing via Reversible Lysine Carbamylation
Xue, J., Shen, B., Wang, J., Li, J., Zhao, H., & Zhang, T. (2025) · ACS Sensors · doi:10.1021/acssensors.5c01661 · Cited by 5
Carbon Dioxide Inhalation—Risks for Health or Opportunity for Physical Fitness Development?
Danek, N. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15010364 · Cited by 7
Indoor environmental quality and the brain: A systematic review of physiological and neural evidence
Rad, P. N., Behzadi, F., Kalantarifard, A., Nazemi, N., & Djebbara, Z. (2026) · Building and Environment · doi:10.1016/j.buildenv.2026.114405 · Cited by 8
Building age is a determining factor of indoor CO2 levels in a University setting
Broadway, L. A., Aycock, H., Broadway, A., Russell, T., Endsley, A., Harley, B., Colmorgan, A., Drafts, T., Estey, D., & Syfert, T. (2025) · Indoor Environments · doi:10.1016/j.indenv.2025.100100 · Cited by 4
Real-time model predictive control of energy recovery ventilators for a school building
Jung, S. Y., Jo, H.-G., & Park, C. (2025) · Science and Technology for the Built Environment · doi:10.1080/23744731.2025.2539048 · Cited by 4
“The increase in CO 2 concentration can harm decision-making ability and lung capacity, and can increase dry eyes, drowsiness, headache, and dizziness (Erdmann and Apte 2004; Satish et al. 2012; Shriram, Ramamurthy, and Ramakrishnan 2019).”
Oyama, I., Tajima, Y., Ojima, T., & Akiyoshi, I. I. D. A. (2022) · Forensic Toxicology · doi:10.1007/s11419-022-00644-8 · Cited by 4
Holistic Approach to Improve Cabin Air Quality in Electric Vehicles and Energy Savings
Lesage, M., Chalet, D., Migaud, J., & Krautner, C. (2023) · International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems (ECOS) · doi:10.52202/069564-0216 · Cited by 4
McCue, M. D. (2023) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.9639 · Cited by 4
Rao, R. S., Sasiharan, G. M., & Ganapathy, S. (2023) · Indian Journal of Occupational and Environmental Medicine · doi:10.4103/ijoem.ijoem_200_22 · Cited by 4
“…when participants were exposed to 1000 ppm and 2500 ppm of CO2 in a simulated strategic task test compared to when they were inhaling an indoor concentration of 600 ppm. [13] Our exploratory study on CO2 levels showed only modest elevation near the surgical team while cautery was being used.”
Statistical Analysis and Modeling of the CO2 Series Emitted by Thirty European Countries
Bărbulescu, A. (2024) · Climate · doi:10.3390/cli12030034 · Cited by 4
Household Air Pollution in Three Urban Function Areas and Related Respiratory Health Effects
Niu, X., Cheng, Y., Tian, X., Chen, S., Dai, W., Mei, H., Huang, Y. H., Hu, T., Sun, J., & Cao, J. (2024) · Aerosol Science and Engineering · doi:10.1007/s41810-024-00227-7 · Cited by 5
“High concentrations of CO 2 indoor is associated with increased prevalence of acute health symptoms such as headaches and mucosal irritation, and slower work performance (Satish et al. 2012).”
Predictive Heating Control and Perceived Thermal Comfort in a Norwegian Office Building
Lolli, N., Gorantonaki, E., & Clauß, J. (2024) · Energies · doi:10.3390/en17153719 · Cited by 5
Optimising Ventilation Strategies for Improved Driving Range and Comfort in Electric Vehicles
Lesage, M., Chalet, D., & Migaud, J. (2025) · World Electric Vehicle Journal · doi:10.3390/wevj16020098 · Cited by 5
Free Range Capital for Indoor Agriculture
Bomford, M. (2025) · Economic Anthropology · doi:10.1002/sea2.70008 · Cited by 4
Maigari, M., Fu, C., Balodimou, E., Kc, P., Sudhakaran, S., & Sakikhales, M. (2025) · Sustainability · doi:10.3390/su17136155 · Cited by 4
Exposure of research personnel to carbon dioxide during euthanasia procedures.
Amparan, A. A., Djoufack-Momo, S. M., Grunden, B. K., & Boivin, G. P. (2014) · PubMed Central · Cited by 4
Czy zwiększona zawartość dwutlenku węgla w powietrzu ma wpływ na sprawność intelektualną człowieka
Murkowski, A., & Skórska, E. (2016) · Cited by 4
Thomas, D., Mistry, B., Snow, S., & schraefel, M. C. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-01174-1_77 · Cited by 4
Qiu, Y., & Ya, T. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/609/4/042032 · Cited by 4
Arakawa, Y. (2020) · Augmented Humans International Conference (AHs) · doi:10.1145/3384657.3385334 · Cited by 4
“Actually, some paper reported that noise[3] and CO2[4] prevent the worker’s concentration.”
BackgroundMethodThe Internet of things and indoor air quality on ship
Metreveli, Y. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/872/1/012015 · Cited by 4
“Regular researches of the carbon dioxide impact on humans in various conditions show that CO2 affects: the ability to make decisions[2], psychomotor abilities and health [3], the efficiency of personnel [4,5], and so the same long-term presence of personnel in an environment with a constant high level of CO2[6].”
BackgroundA Statistical Evaluation of Combining Human Productivity Metrics in the Indoor Environment
Keene, K., & Jung, W. (2021) · ASME Journal of Engineering for Sustainable Buildings and Cities · doi:10.1115/1.4052872 · Cited by 4
No Climate-Resilient Society Without a Resilient Transport System
Glock, J. P., Hartl, R., Krieg, M., & Becker, U. (2021) · Springer eBooks · doi:10.1007/978-3-030-42462-6_132 · Cited by 6
Indoor Air Quality: Status and Standards
Hasager, F., Bjerregaard, J. D., Bonomaully, J., Knap, H. C., Afshari, A., & Johnson, M. S. (2020) · Springer eBooks · doi:10.1007/978-1-0716-0596-7_1097 · Cited by 5
Snow, S., Danam, R., Leardini, P., Glencross, M., Beeson, B., Ottenhaus, L.-M., & Bodén, M. (2022) · Frontiers in Computer Science · doi:10.3389/fcomp.2022.888688 · Cited by 5
“At 2,500 ppm of CO2, a laboratory study found large and statistically significant reductions occurred in seven scales of decision-making performance (Satish et al., 2012).”
BackgroundMax Fast Fourier Transform (maxFFT) Clustering Approach for Classifying Indoor Air Quality
Chu, K.-U., & Ho, Y.-H. (2022) · Atmosphere · doi:10.3390/atmos13091375 · Cited by 4
Dingemanse, J. D., Abiyu, M. A., Tesfaye, K. G., & Roro, F. F. (2022) · Clean Air Journal · doi:10.17159/caj/2022/32/2.13470 · Cited by 6
Chemistry of Indoor Air Pollution
Eftekhari, A., Won, Y., Morrison, G., & Ng, N. L. (2023) · ACS in focus · doi:10.1021/acsinfocus.7e7018 · Cited by 7
Seol, H., Arztmann, D., Kim, N., & Balderrama, A. (2023) · Sustainability · doi:10.3390/su15139892 · Cited by 4
Impact of Energy Consumption on CO2 emissions: Case of Pakistan
Bukhari, N., & Waseem, M. (2017) · Journal of Management Info · doi:10.31580/jmi.v13i1.66 · Cited by 4
“Satish et al (2012) talk about the higher demand of energy result”
BackgroundDeng, Y., Sprowls, M., Mora, S. J., Kulick, D., Tao, N. J., Destaillats, H., & Forzani, E. (2020) · Sensors · doi:10.3390/s20247202 · Cited by 4
Hypoxia, Hypercarbia, and Atmospheric Control
Beck, G., Law, J., Bacal, K., & Barratt, M. R. (2019) · Springer eBooks · doi:10.1007/978-1-4939-9889-0_3 · Cited by 4
Kim, J., Hong, T., Hastak, M., & Jeong, K. (2020) · Journal of Asian Architecture and Building Engineering · doi:10.1080/13467581.2020.1803076 · Cited by 7
“…Lee et al. 2012; Higgins et al. 2005; Mendell et al. 2016; Myhrvold, Olsen, and Lauridsen 1996; Nordström, Norbäck, and Akselsson 1994; Persily 2015; Satish et al. 2012; Seppänen and Fisk 2004; Wargocki et al. 2002; Wargocki and Wyon 2007; Wargocki, Wyon, and Fanger 2000; Wargocki et al. 1999).”
BackgroundToftum, J., Andersen, R. K., Aguilera, J. J., Kolstrup, K., Hauberg, D. S., & Clausen, G. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111274 · Cited by 4
Ventilação natural e qualidade do ar em salas de aula: revisão sistemática da literatura
Silva, S. V. D. O., Pagel, É. C., Bastos, L. E. G., & Santos, C. M. L. (2022) · PARC Pesquisa em Arquitetura e Construção · doi:10.20396/parc.v13i00.8666284 · Cited by 11
“Por isso, o dióxido de carbono é considerado um indicador da qualidade do ar interior (ALMEIDA et al., 2017; SATISH et al., 2012).”
BackgroundInfluentialIndoor Air Quality: Status and Standards
Hasager, F., Bjerregaard, J. D., Bonomaully, J., Knap, H. C., Afshari, A., & Johnson, M. S. (2019) · Springer eBooks · doi:10.1007/978-1-4939-2493-6_1097-1 · Cited by 6
Measuring Indoor Environmental Quality (IEQ) in a National School Property Portfolio
ACKLEY, A. U. (2021) · Open Access Victoria University of Wellington | Te Herenga Waka (Figshare) · doi:10.26686/wgtn.14050715.v1 · Cited by 7
Occurrence and Mitigation of PM2.5, NO2, CO and CO2 in Homes Due to Cooking and Gas Stoves
Jaffe, D. A., Nirschl, D., & Birman, S. (2025) · Atmosphere · doi:10.3390/atmos16070882 · Cited by 3
Cho, B.-J., & Kim, S. (2025) · Toxics · doi:10.3390/toxics13080692 · Cited by 5
“…to systemic inflammation or carcinogenesis [7–9, 11 ,15 Interestingly, higher indoor CO 2 concentrations were sometimes associated with lower biomarker levels, likely reflecting differences in indoor air ventilation or occupancy patterns rather than direct physiological mechanisms [11,14,33,36].”
InfluentialCao, X., Fang, H., & Yuan, X. (2025) · Buildings · doi:10.3390/buildings15173168 · Cited by 7
Pellegatti, M., Visentin, C., Torresin, S., Babich, F., Wargocki, P. L., & Prodi, N. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.114005 · Cited by 9
AlKakuri, M., Elkhouly, A., Jaafar, K., & Gouda, H. (2025) · Aerosol and Air Quality Research · doi:10.1007/s44408-025-00068-0 · Cited by 3
“5 hospital visits for asthma increasing by 0.67% per 10 µg/m 3 increase Satish et al. (2012) Indoor CO 2 concentrations at 1000 ppm and above lead to significant reductions in decision-making performance and cognitive function, with a 20–50% decrease in cognitive scores Wyon (2004) Elevated indoor…”
InfluentialVarnosfaderani, M. P., & Heydarian, A. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.114134 · Cited by 7
Natural Ventilation Reduces Cooking-Related PM 2.5 Peaks Indoors
Su, Y., Dai, Y., Shi, Z., Jiang, Y., Kong, L., & Pfrang, C. (2026) · ACS ES&T Air · doi:10.1021/acsestair.5c00427 · Cited by 3
Petrić, V., Strbad, D., Račić, N., Hussein, T., Kecorius, S., Mureddu, F., & Lovrić, M. (2026) · Atmosphere · doi:10.3390/atmos17020184 · Cited by 6
Pollutions of Cooking Oil Fume and Health Risks
Li, A., & Kosonen, R. (2019) · Springer eBooks · doi:10.1007/978-981-13-6496-9_3 · Cited by 4
Towards safer indoor spaces: A machine learning based CO2 forecasting approach for smart systems
Athanasakis, E., Pantelidou, K., Siopis, N., Bizopoulos, P. A., Lalas, A. X., Votis, K., & Tzovaras, D. (2024) · IEEE Conference on Evolving and Adaptive Intelligent Systems (EAIS) · doi:10.1109/eais58494.2024.10570031 · Cited by 4
“Although it is not linked to the development of chronic respiratory diseases, studies have shown that high CO 2 concentrations can lead to impaired cognitive function and decision-making performance [9] [10].”
BackgroundIn-Vehicle Air Pollutant Exposures from Daily Commute in the San Francisco Bay Area, California
Deevi, R., & Lu, M. (2024) · Atmosphere · doi:10.3390/atmos15091130 · Cited by 3
Lu, F. T., Gupta, D., Fiedler, N. L., Satish, U., Black, K., Legard, A., Resende, A. D., Guo, C., Gow, A. J., & Kipen, H. M. (2024) · Environmental Health Perspectives · doi:10.1289/ehp14806 · Cited by 3
Self-citationAtmospheric-level carbon dioxide gas sensing using low-loss mid-IR silicon waveguides
Lin, P.-S., Quellmalz, A., Parhizkar, S., Huang, P., Negm, N., Suckow, S., Briano, F. O., Lemme, M. C., Schall-Giesecke, A. L., Niklaus, F., et al. (2024) · Optics Express · doi:10.1364/oe.527421 · Cited by 3
García-Martín, G., Romero-Lara, F., Campano, M. Á., Acosta, I., & Bustamante, P. (2025) · Applied Sciences · doi:10.3390/app15031217 · Cited by 6
Building occupancy estimation using single channel CW radar and deep learning
Pramanik, S. K., Hossain, M. S., & Islam, S. M. M. (2025) · Scientific Reports · doi:10.1038/s41598-025-95752-x · Cited by 5
“Misclassification rates were higher for occupancy levels 5, 6, and 7, which can be attributed to increased signal intermodulation and reduced separability in the time-frequency domain.”
Wang, X., Jiang, Y., Long, X., Yan, Z., You, D., & Guo, T. (2025) · Chemical Engineering Journal · doi:10.1016/j.cej.2025.165017 · Cited by 3
On the Influence of Indoor Temperature on Occupant’s Performance
Markov, D. G., Yordanov, P. S., Симова, И., Ivanov, M., Kehaiova, N. N., & Georgiev, E. (2014) · Cited by 3
Xie, X., Lu, Q., Parlikad, A. K., & Puri, R. S. (2020) · ASCE Construction Research Congress (CRC) · doi:10.1061/9780784482865.028 · Cited by 3
Measurement methods and evaluation techniques of indoor CO2 in a cabin for an electric crane
Muratori, L., Peretto, L., Bottiglieri, G., Coiro, F., Pulvirenti, B., & Sante, R. D. (2021) · IEEE International Workshop on Metrology for Automotive (MetroAutomotive) · doi:10.1109/metroautomotive50197.2021.9502887 · Cited by 3
Assessment of energy saving due to a flexible indoor air quality control
Muratori, L., Peretto, L., Bottiglieri, G., Coiro, F., Pulvirenti, B., & Sante, R. D. (2021) · IEEE International Workshop on Metrology for Automotive (MetroAutomotive) · doi:10.1109/metroautomotive50197.2021.9502848 · Cited by 3
Validity of the strategic management simulations to predict real‐world productivity
MacNaughton, P., & Cockerill, A. P. (2021) · Journal of Applied Social Psychology · doi:10.1111/jasp.12771 · Cited by 3
Indoor air quality assessment inside secondary public classrooms in Jeddah, Saudi Arabia
Alama, A., & Sabbagh, M. (2022) · Journal of Engineering Research · doi:10.36909/jer.12937 · Cited by 3
Zeng, W., Liu, H., Hou, S., Qiu, X., Chen, X., Liu, M., Wu, D., & Liu, L. (2022) · Atmosphere · doi:10.3390/atmos13071006 · Cited by 4
Air Quality in Fitness Centers: The Impact of Ventilation Restrictions - A Case Study
Peixoto, C., Slezáková, K., Pereira, M. D. C., & Morais, S. (2022) · U Porto Journal of Engineering · doi:10.24840/2183-6493_008.004_0004 · Cited by 3
“Whereas CO2 does not pose a direct hazard to human health at the levels detected in clubs, exposure to moderate concentrations can cause changes in human performances and influence decision-making (Persily 1997; Satish et al. 2012).”
BackgroundWu, C., Herbst, G., Lujan, A., & Kim, K. H. (2022) · Annual Modeling and Simulation Conference (ANNSIM) · doi:10.23919/annsim55834.2022.9859444 · Cited by 3
“While CO2 is not often considered a pollutant, with high concentration, it can reduce work productivity (Satish et al. 2012).”
BackgroundEffects of IAQ on Office Work Performance
Porras-Salazar, J. A., Schiavon, S., & Tham, K. W. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-10-5155-5_64-1 · Cited by 3
CuxO/Cu based electrochemical sensor for the detection of CO2 gas
Digvijay, B., Amala, J., Aravind, S. P., Bhuvaneshwari, S., & Mohanraj, P. (2022) · Indian Chemical Engineer · doi:10.1080/00194506.2022.2114947 · Cited by 3
“04%); if concentration rises above 2% (20,000 ppm), it causes panting and breathlessness; above 10% (100,000 ppm), it results in tremors and loss of consciousness, and above 25% (250,000 ppm) is fatal [2].”
BackgroundIndoor Air Quality in the Context of Climate Change
Kinney, P. L. (2022) · Handbook of Indoor Air Quality · doi:10.1007/978-981-16-7680-2_74 · Cited by 4
Yang, H.-H., Kwak, M.-J., Kim, K. J., & Kim, H.-H. (2022) · Journal of people, plants, and environment · doi:10.11628/ksppe.2022.25.6.571 · Cited by 3
Patil, V. S., Nandurdikar, V., Shelar, M. N., Barahate, S. D., Pagare, A., & Chandratre, M. (2023) · Sadhana · doi:10.1007/s12046-023-02094-3 · Cited by 3
“Usha et al have assessed the direct effects of increased CO2 on decision making performances considering various factors [5].”
BackgroundModifiable Indoor Environmental Factors: Impact on Human Health and Digital Monitoring.
Lebedev, G. S., Moscow, R., Shaderkin, I. A., & Lebedeva, N. A. (2023) · Russian Journal of Telemedicine and E-Health · doi:10.29188/2712-9217-2023-9-1-21-48 · Cited by 3
Indoor CO 2 phytoremediation using ornamental plants: A case study in Gresik, Indonesia
Tangahu, B. V., Przybysz, A., Mashudi, M., Popek, R., Faz, M. R. I., Titah, H. S., Purwanti, I. F., Pismanik, M., & Mangkoedihardjo, S. (2024) · Ecological Research · doi:10.1111/1440-1703.12511 · Cited by 5
Azrak, V., Öter, Ö., Oğuzlar, S., & Bursalı, E. A. (2024) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-024-13455-x · Cited by 3
Santalunai, S., Pakprom, J., Charoensiri, W., Thongsopa, C., Thosdeekoraphat, T., Janpangngern, P., Santalunai, N., & Santalunai, S. (2024) · IEEE Access · doi:10.1109/access.2024.3456180 · Cited by 3
“Additionally, indoor CO 2 concentrations more than 1000 ppm can have various health impacts, further emphasizing the need to control CO 2 levels [7], [8].”
BackgroundEmotion Estimation Using Noncontact Environmental Sensing with Machine and Deep Learning Models
Isogami, T., & Komuro, N. (2025) · Applied Sciences · doi:10.3390/app15020721 · Cited by 3
Zhao, C., Morsli, S., & Ganaoui, M. E. (2025) · E3S Web of Conferences · doi:10.1051/e3sconf/202560201002 · Cited by 3
“Elevated CO₂ concentrations can lead to adverse health effects, including headaches, fatigue, and decreased cognitive performance [7, 8].”
Keene, K., McCord, K. H., Dehwah, A. H. A., & Jung, W. (2025) · Indoor Air · doi:10.1155/ina/6840369 · Cited by 5
“Indoors, CO 2 has been shown to act as a surrogate for ventilation rate [6] and indoor-generated pollutant levels [7], rather than being an exposure metric for impacts on human health directly [8].”
Bastuck, M., Schütze, A., Puglisi, D., Möller, P., Spetz, A. L., Andersson, M., & Reimringer, W. (2017) · SENSOR International Conference on Sensors and Measurement Technology (SENSOR) · doi:10.5162/sensor2017/p5.4 · Cited by 3
Monitorização e controlo de qualidade do ar interior em gabinetes de edifícios escolares
Fernandes, S., Igrejas, G., & Feliciano, M. (2017) · Revista de Ciências Agrárias · doi:10.19084/rca16192 · Cited by 3
Heo, S., Kim, W., Lee, T.-J., Adelodun, A. A., & Jo, Y. M. (2021) · Asian Journal of Atmospheric Environment · doi:10.5572/ajae.2020.132 · Cited by 3
“Therefore, effective management of IAQ CO2 is necessary for human health (Satish et al. , 2012).”
BackgroundBehavioral complexity theory: Seven decades and beyond
Cockerill, A. P., & Satish, A. (2021) · Journal of Applied Social Psychology · doi:10.1111/jasp.12838 · Cited by 3
Effects of ERV Filter Degradation on Indoor CO2 Levels of a Classroom
Choi, J.-S., Lee, J., & Kim, E.-J. (2018) · Sustainability · doi:10.3390/su10041215 · Cited by 3
“[6] attempted to assess the effects of increased CO2 on decision-making performance by means of chamber tests with six groups of four participants.”
Methodde Araújo, T., Silva, L. T., & Moreira, A. J. C. (2020) · International Conference on Sensor Networks · doi:10.5220/0008968400410051 · Cited by 3
“In an indoor scenario, they can also be used for air-quality assessment by monitoring the levels of CO 2 , once it has relevant consequences on cognitive performance of the occupants, as described by (Allen et al., 2016; Satish et al., 2012).”
BackgroundHealth Effects of Atmospheric Contamination
James, J. T., & Ryder, V. E. (2019) · Springer eBooks · doi:10.1007/978-1-4939-9889-0_4 · Cited by 3
Strategies for Well-being in New Work Spaces: A Case Study in a Post-Pandemic Context
León, M. J. A., & Abella, A. (2022) · Temes de disseny · doi:10.46467/tdd38.2022.132-161 · Cited by 8
The Effect of Students, Computers, and Air Purifiers on Classroom Air Quality
Dabanlis, G., Loupa, G., Liakos, D., & Rapsomanikis, S. (2022) · Applied Sciences · doi:10.3390/app122311911 · Cited by 4
“When the attendance was high (30–42 students) and windows and the door were kept closed, CO2 concentrations ranged between 861 ppm (percentile 10%) and 2746 ppm (percentile 90%), indicating a moderate to poor IAQ [23].”
BackgroundSantos, C. R. (2020) · Revista Brasileira de Ciências Ambientais · doi:10.5327/z2176-947820200540 · Cited by 3
Mendell, M. J., & Fisk, W. J. (2014) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1164281 · Cited by 5
“Another important unresolved question, raised in recent publications (Kajtar et al. 2006; Satish et al. 2012) is whether carbon dioxide (CO 2 ) itself may be an indoor pollutant, rather than just an indicator of ventilation adequacy for removing other pollutants.”
Self-citationEnergy use and indoor environment in new and existing dwellings in Arctic climates
Kotol, M. (2014) · Cited by 3
Rogers, T., Swickrath, M. J., Graf, J. C., Verduzco, R., & Sharma, S. (2018) · ThinkTech (Texas Tech University) · Cited by 3
INDOOR AIR QUALITY IN NONINDUSTRIAL OCCUPATIONAL ENVIRONMENTS
Morey, P. R., & Shaughnessy, R. J. (2019) · Wiley eBooks · doi:10.1002/9781119581482.ch8 · Cited by 3
Practical application of CO 2 as an indicator regarding the risk of infectionPreprint
Hartmann, A., Çetin, Y. E., Gastmeier, P., & Kriegel, M. (2022) · medRxiv · doi:10.1101/2022.07.14.22277631 · Cited by 3
“Recent 39 findings point out that high CO2 levels in indoor spaces may cause detrimental outcomes on health and 40 cognitive function [11, 12].”
BackgroundTaamté, J. M., Signing, V. R. F., Modibo, O. B., Kountchou, M., Abba, H. Y., & Saïdou, S. (2023) · Research Square · doi:10.21203/rs.3.rs-2987539/v1 · Cited by 3
R.H. Board, Barrow, J., Whelton, C., & Tim Board (2024) · Journal of Orthopaedics · doi:10.1016/j.jor.2024.06.007 · Cited by 2
Improving Indoor Air Quality in a Higher-Education Institution Through Biophilic Solutions
Gomes, M. I., Barreiros, A. M., Pinto, I., & Rodrigues, A. (2025) · Sustainability · doi:10.3390/su17115041 · Cited by 9
Metadata
- Authors
- Satish, U., Mendell, M. J., Shekhar, K., Hotchi, T., Sullivan, D., Streufert, S., & Fisk, W. J.
- Affiliations
- SUNY Upstate Medical University (US)
- Lawrence Berkeley National Laboratory (US)
- Corresponding author
- Mendell, Mark J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-20
- Volume
- 120
- Issue
- 12
- Pages
- 1671-1677
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- PMC
- PMC3548274
- OpenAlex
- W2089734242
- Cited by
- 1,064
- References
- 24
- Citations by year
- 2026: 105 · 2025: 119 · 2024: 103 · 2023: 108 · 2022: 92 · 2021: 123 · 2020: 94 · 2019: 80 · 2018: 63 · 2017: 47 · 2016: 44 · 2015: 34 · 2014: 33 · 2013: 16 · 2012: 1
- FWCI
- 18.60
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- public-domain
- creativecommons.org/licenses/by/4.0/ (vor, 1926 d)
- Locations
- Environmental Health Perspectives (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Syracuse University
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor carbon dioxide, decision performance, cognitive performance, indoor air quality, ventilation rate, health symptoms, perceived air quality, CO2 exposure, office buildings
- MeSH terms
- Adolescent, Adult, Air Pollutants, Analysis of Variance, Carbon Dioxide, Decision Making, Dose-Response Relationship, Drug, Environmental Exposure, Environmental Monitoring, Female, Humans, Male, Surveys and Questionnaires, Ventilation, Air Pollution, Indoor, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.