Coronal alignment after total knee replacement
The DOI matches its Crossref record.
Abstract
Maquet's line passes from the centre of the femoral head to the centre of the body of the talus. The distance of this line from the centre of the knee on a long-leg radiograph provides the most accurate measure of coronal alignment. Malalignment causes abnormal forces which may lead to loosening after knee replacement. We report a series of 115 Denham knee replacements performed between 1976 and 1981 using the earliest design of components, inserted with intramedullary guide rods. Patients were assessed clinically and long-leg standing radiographs were taken before operation, soon after surgery and up to 12 years later. In two-thirds of the knees (68%) Maquet's line passed through the middle third of the prosthesis on postoperative films and the incidence of subsequent loosening was 3%. When Maquet's line was medial or lateral to this, an error of approximately +/- 3 degrees, the incidence of loosening at a median period of eight years was 24%. This difference is highly significant (p = 0.001). Accurate coronal alignment appears to be an important factor in prevention of loosening. Means of improving the accuracy of alignment and of measuring it on long-leg radiographs are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
The Effect of Alignment and BMI on Failure of Total Knee Replacement
Ritter, M. A., Davis, K. E., Meding, J. B., Pierson, J. L., Berend, M. E., & Malinzak, R. A. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00772 · Cited by 669
Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b5.14927 · Cited by 667
Choong, P. F., Dowsey, M. M., & Stoney, J. D. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.02.018 · Cited by 447
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00002 · Cited by 429
Good Alignment After Total Knee Arthroplasty Leads to Faster Rehabilitation and Better Function
Longstaff, L. M., Sloan, K., Stamp, N., Scaddan, M., & Beaver, R. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2008.03.002 · Cited by 380
Kim, Y.-H., Park, J.-W., Kim, J.-S., & Park, S.-D. (2014) · International Orthopaedics · doi:10.1007/s00264-013-2097-9 · Cited by 367
Meta-Analysis of Navigation vs Conventional Total Knee Arthroplasty
Hetaimish, B. M., Khan, M. M., Simunovic, N., Al-Harbi, H. H., Bhandari, M., & Zalzal, P. K. (2012) · The Journal of Arthroplasty · doi:10.1016/j.arth.2011.12.028 · Cited by 352
Kayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5138-5 · Cited by 338
Vanlommel, L., Vanlommel, J., Claes, S., & Bellemans, J. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2481-4 · Cited by 322
Bonner, T. J., Eardley, W. G. P., Patterson, P., & Gregg, P. J. (2011) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.93b9.26573 · Cited by 302
Almaawi, A. M., Hutt, J. R. B., Masse, V., Lavigne, M., & Vendittoli, P.-A. (2017) · The Journal of Arthroplasty · doi:10.1016/j.arth.2017.02.028 · Cited by 302
The effect of valgus/varus malalignment on load distribution in total knee replacements
Werner, F. W., Ayers, D. C., Maletsky, L. P., & Rullkoetter, P. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.024 · Cited by 289
Howell, S. M., Kuznik, K., Hull, M. L., & Siston, R. A. (2008) · Orthopedics · doi:10.3928/01477447-20080901-15 · Cited by 288
Technique and first clinical results of robot-assisted total knee replacement
Siebert, W., Mai, S., Kober, R., & Heeckt, P. F. (2002) · The Knee · doi:10.1016/s0968-0160(02)00015-7 · Cited by 281
Alignment in total knee replacement
Sikorski, J. M. (2008) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.90b9.20793 · Cited by 276
Mechanical, Anatomical, and Kinematic Axis in TKA: Concepts and Practical Applications
Cherian, J. J., Kapadia, B. H., Banerjee, S., Jauregui, J. J., Issa, K., & Mont, M. A. (2014) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-014-9218-y · Cited by 274
Chauhan, S. K., Clark, G. W., Lloyd, S., Scott, R. G., Breidahl, W., & Sikorski, J. M. (2004) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.86b6.15456 · Cited by 272
Song, E., Seon, J., Park, S., Jung, W. B., Park, H., & Lee, G. W. (2011) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1400-9 · Cited by 268
de Steiger, R. N., Liu, Y.-L., & Graves, S. E. (2015) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.01496 · Cited by 267
Liow, M. H. L., Xia, Z., Wong, M. K., Tay, K. J., Yeo, S. J., & Chin, P. L. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.12.010 · Cited by 265
Kinematically Versus Mechanically Aligned Total Knee Arthroplasty
Dossett, H. G., Swartz, G. J., Estrada, N. A., LeFevre, G. W., & Kwasman, B. G. (2012) · Orthopedics · doi:10.3928/01477447-20120123-04 · Cited by 264
Young, S. W., Walker, M. L., Bayan, A., Briant-Evans, T., Pavlou, P., & Farrington, B. (2017) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-016-4844-x · Cited by 256
van der List, J. P., Chawla, H., Joskowicz, L., & Pearle, A. D. (2016) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-016-4305-9 · Cited by 200
“Since many studies suggested a correlation between tighter control of these variables and better outcomes [7, 18, 28, 50, 58, 86, 96, 98], one can expect better outcomes following joint replacement using computer navigation, especially at longer follow-up.”
BackgroundCourtney, P. M., & Lee, G.-C. (2017) · The Journal of Arthroplasty · doi:10.1016/j.arth.2017.02.041 · Cited by 194
Residual Varus Alignment does not Compromise Results of TKAs in Patients with Preoperative Varus
Magnussen, R. A., Weppe, F., Demey, G., Servien, E., & Lustig, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1988-6 · Cited by 188
“Although two recent studies found little correlation between limb alignment and revision rates [21, 22], the majority of studies showed increased revision rates with malalignment, particularly in varus [3, 8, 12, 15, 23, 27] (Table 4).”
BackgroundResultInfluentialThe Cost-Effectiveness of Computer-Assisted Navigation in Total Knee Arthroplasty
Novak, E. J., Silverstein, M. D., & Bozic, K. J. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200711000-00008 · Cited by 181
Kim, R., Wakelin, E. A., Plaskos, C., Gupta, S., & Putman, S. (2023) · International Orthopaedics · doi:10.1007/s00264-022-05636-2 · Cited by 20
Metadata
- Authors
- Jeffery, R., Morris, R., & Denham, R.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1991-09
- Volume
- 73-B
- Issue
- 5
- Pages
- 709-714
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2125502857
- Cited by
- 1,100
- References
- 0
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.