The DOI matches its Crossref record; 47 of the 50 references it cites were found in a registry or an index, and 3 are not checked yet.
Realization of a timescale with an accurate optical lattice clock
Open accessAbstract
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This international all-optical clock measurement surpasses the accuracy of the best possible comparison achievable by measurements against primary caesium clocks by one order of magnitude5212223.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [22]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The accuracy of the former method is limited by the caesium microwave clocks with the most stringent bound set by our groups5212223 at an agreement within 4 × 10−16”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [22]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“After accounting for a linear drift, the dominant contribution to the extrapolation uncertainty is due to the stochastic maser behaviour 42,43,86 .”
From Intercontinental comparison of optical atomic clocks through very long baseline interferometry (2021) · cites this paper as [43]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The details of the actual implementation of state preparation and interrogation being quite different in the two experimental realizations of a Sr lattice clock5212223, systematic and statistical uncertainties are highly independent and uncorrelated.”
From A clock network for geodesy and fundamental science (2016) · cites this paper as [22]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
A sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Keßler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 755
Self-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationCryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Self-citation8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286
Self-citationExperimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Dissemination of time and RF frequency via a stabilized fibre optic link over a distance of 420 km
Śliwczyński, Ł., Krehlik, P., Czubla, A., Buczek, Ł., & Lipiński, M. (2013) · Metrologia · doi:10.1088/0026-1394/50/2/133 · Cited by 203
Sr87 Lattice Clock with Inaccuracy below 10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
Space clocks and fundamental tests: The ACES experiment
Cacciapuoti, L., & Salomon, C. (2009) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2009-01041-7 · Cited by 187
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174
Self-citationUncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., bner, U. H., der, R. S., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Self-citationThe absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 153
Frequency stabilization to 6 × 10−16 via spectral-hole burning
Thorpe, M. J., Rippe, L., Fortier, T. M., Kirchner, M. S., & Rosenband, T. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.215 · Cited by 130
Uncertainty evaluation of the caesium fountain clock PTB-CSF2
Gerginov, V. P., Nemitz, N., Weyers, S., Schröder, R., Griebsch, D., & Wynands, R. (2009) · Metrologia · doi:10.1088/0026-1394/47/1/008 · Cited by 129
Self-citationThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Self-citationDubé, P., Madej, A. A., Zhou, Z., & Bernard, J. E. (2013) · Physical Review A · doi:10.1103/physreva.87.023806 · Cited by 127
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114
Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer
Hong, F.-L., Musha, M., Takamoto, M., Inaba, H., Yanagimachi, S., Takamizawa, A., Watabe, K.-I., Ikegami, T., Imae, M., Fujii, Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000692 · Cited by 113
An optical lattice clock with spin-polarized 87Sr atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Abgrall, M., Rovera, D., Laurent, P., Rosenbusch, P., et al. (2007) · The European Physical Journal D · doi:10.1140/epjd/e2007-00330-3 · Cited by 112
Self-citationGeneration of UTC(PTB) as a fountain-clock based time scale
Bauch, A., Weyers, S., Piester, D., Staliuniene, E., & Yang, W. (2012) · Metrologia · doi:10.1088/0026-1394/49/3/180 · Cited by 104
Self-citationUltra-low-phase-noise cryocooled microwave dielectric-sapphire-resonator oscillators
Hartnett, J. G., Nand, N. R., & Lu, C. (2012) · Applied Physics Letters · doi:10.1063/1.4709479 · Cited by 88
Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
Weyers, S., Gerginov, V. P., Nemitz, N., Li, R., & Gibble, K. (2011) · Metrologia · doi:10.1088/0026-1394/49/1/012 · Cited by 87
Self-citationMatsubara, K., Hachisu, H., Li, Y., Nagano, S., Locke, C., Nogami, A., Kajita, M., Hayasaka, K., Ido, T., & Hosokawa, M. (2012) · Optics Express · doi:10.1364/oe.20.022034 · Cited by 87
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
Self-citationUltrastable laser with average fractional frequency drift rate below 5 × 10^−19/s
Hagemann, C., Grebing, C., Lisdat, C., Falke, S., Legero, T., Sterr, U., Riehle, F., Martin, M. J., & Ye, J. (2014) · Optics Letters · doi:10.1364/ol.39.005102 · Cited by 78
Self-citationScattering of Cold-Atom Coherences by Hot Atoms: Frequency Shifts from Background-Gas Collisions
Gibble, K. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.180802 · Cited by 72
Benkler, E., Lisdat, C., & Sterr, U. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/565 · Cited by 69
Self-citationFirst Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM
Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Zang, E., Sun, Z. G., Fang, F., Li, T., & Fang, Z. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/090601 · Cited by 67
Invited Review Article: The statistical modeling of atomic clocks and the design of time scales
Levine, J. (2012) · Review of Scientific Instruments · doi:10.1063/1.3681448 · Cited by 63
Yamaguchi, A., Shiga, N., Nagano, S., Li, Y., Ishijima, H., Hachisu, H., Kumagai, M., & Ido, T. (2012) · Applied Physics Express · doi:10.1143/apex.5.022701 · Cited by 60
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53
Self-citationUltrahigh long-term dimensional stability of a sapphire cryogenic optical resonator
Storz, R., Braxmaier, C., Jäck, K., Pradl, O., & Schiller, S. (1998) · Optics Letters · doi:10.1364/ol.23.001031 · Cited by 53
UTCr: a rapid realization of UTC
Petit, G., Arias, E. F., Harmegnies, A., Panfilo, G., & Tisserand, L. (2013) · Metrologia · doi:10.1088/0026-1394/51/1/33 · Cited by 50
Akamatsu, D., Inaba, H., Hosaka, K., Yasuda, M., Onae, A., Suzuyama, T., Amemiya, M., & Hong, F.-L. (2013) · Applied Physics Express · doi:10.7567/apex.7.012401 · Cited by 50
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
Yu, D.-H., Weiss, M., & Parker, T. E. (2007) · Metrologia · doi:10.1088/0026-1394/44/1/014 · Cited by 44
Panfilo, G., & Parker, T. E. (2010) · Metrologia · doi:10.1088/0026-1394/47/5/005 · Cited by 38
Margolis, H. (2014) · Nature Physics · doi:10.1038/nphys2834 · Cited by 33
Parker, T. E. (2012) · Review of Scientific Instruments · doi:10.1063/1.3682002 · Cited by 28
Tanabe, T., Akamatsu, D., Kobayashi, T., Takamizawa, A., Yanagimachi, S., Ikegami, T., Suzuyama, T., Inaba, H., Okubo, S., Yasuda, M., et al. (2015) · Journal of the Physical Society of Japan · doi:10.7566/jpsj.84.115002 · Cited by 28
Hydrogen maser ensemble performance and characterization of frequency standards
Parker, T. E. (2003) · doi:10.1109/freq.1999.840736 · Cited by 28
Automatic laser control for a88Sr+optical frequency standard
Barwood, G. P., Gill, P. R., Huang, G., & Klein, H. A. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/5/055201 · Cited by 27
Subhertz-linewidth infrared frequency source with a long-term instability below 5 × 10−15
Raupach, S. M. F., Legero, T., Grebing, C., Hagemann, C., Keßler, T., Koczwara, A., Lipphardt, B., Misera, M., Schnatz, H., Grosche, G., et al. (2012) · Applied Physics B · doi:10.1007/s00340-012-5280-6 · Cited by 6
Self-citation
Cited by
Sorted by citations
Optical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K. J., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 746
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Self-citationFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
Metadata
- Authors
- Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2016-05-25
- Volume
- 3
- Issue
- 6
- Pages
- 563
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2295004978
- Cited by
- 149
- References
- 47
- Citations by year
- 2026: 8 · 2025: 11 · 2024: 10 · 2023: 13 · 2022: 11 · 2021: 9 · 2020: 22 · 2019: 21 · 2018: 26 · 2017: 12 · 2016: 6
- FWCI
- 10.25
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Optica (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Centre of Quantum Engineering and Space-Time Research (QUEST)
- German Research Foundation (DFG) (RTG 1729, CRC 1128)
- International Timescales with Optical Clocks (ITOC)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- optical lattice clock, redefinition of the second, clock frequency stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review