Towards the optical second: verifying optical clocks at the SI limit
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
The pursuit of ever more precise measures of time and frequency motivates redefinition of the second in terms of an optical atomic transition. To ensure continuity with the current definition, based on the microwave hyperfine transition in 133Cs, it is necessary to measure the absolute frequency of candidate optical standards relative to primary cesium references. Armed with independent measurements, a stringent test of optical clocks can be made by comparing ratios of absolute frequency measurements against optical frequency ratios measured via direct optical comparison. Here we measure the S01→P03 transition of 171Yb using satellite time and frequency transfer to compare the clock frequency to an international collection of national primary and secondary frequency standards. Our measurements consist of 79 runs spanning eight months, yielding the absolute frequency to be 518 295 836 590 863.71(11) Hz and corresponding to a fractional uncertainty of 2.1 × 10−16. This absolute frequency measurement, the most accurate reported for any transition, allows us to close the Cs-Yb-Sr-Cs frequency measurement loop at an uncertainty <3 × 10−16, limited for the first time by the current realization of the second in the International System of Units (SI). Doing so represents a key step towards an optical definition of the SI second, as well as future optical time scales and applications. Furthermore, these high accuracy measurements distributed over eight months are analyzed to tighten the constraints on variation of the electron-to-proton mass ratio, μ=me/mp. Taken together with past Yb and Sr absolute frequency measurements, we infer new bounds on the coupling coefficient to gravitational potential of kμ=(−1.9±9.4)×10−7 and a drift with respect to time of μ˙μ=(5.3±6.5)×10−17/yr.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationFrequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Self-citationGeodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Ultrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
Self-citationImproved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
First accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Self-citationA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Flambaum, V. V., & Tedesco, A. F. (2006) · Physical Review C · doi:10.1103/physrevc.73.055501 · Cited by 163
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
The87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Months-long real-time generation of a time scale based on an optical clock
Hachisu, H., Nakagawa, F., Hanado, Y., & Ido, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-22423-5 · Cited by 83
Cs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Advanced Satellite-Based Frequency Transfer at the 10−16 Level
Fujieda, M., Yang, S.-H., Gotoh, T., Hwang, S.-W., Hachisu, H., Kim, H., Lee, Y. K., Tabuchi, R., Ido, T., Lee, W.-K., et al. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2821159 · Cited by 55
Hachisu, H., Petit, G., Nakagawa, F., Hanado, Y., & Ido, T. (2017) · Optics Express · doi:10.1364/oe.25.008511 · Cited by 53
Sensitivity of hyperfine structure to nuclear radius and quark mass variation
Dinh, T. H., Dunning, A., Dzuba, V. A., & Flambaum, V. V. (2009) · Physical Review A · doi:10.1103/physreva.79.054102 · Cited by 46
Uncertainty of a frequency comparison with distributed dead time and measurement interval offset
Yu, D.-H., Weiss, M., & Parker, T. E. (2007) · Metrologia · doi:10.1088/0026-1394/44/1/014 · Cited by 44 · cited 1×
“The dead time uncertainty [27] associated with intermittent operation of the optical standard is comprehensively evaluated in Part A of Supplement 1 and amounts to the largest source of statistical uncertainty; see Table 1.”
BackgroundSelf-citationMargolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40
Atomic clocks: new prospects in metrology and geodesy
Delva, P., & Lodewyck, J. (2013) · arXiv · doi:10.48550/arxiv.1308.6766 · Cited by 40
Cited by
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Self-citationImproved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons
Lange, R., Huntemann, N., Rahm, J. M., Sanner, C., Shao, H., Lipphardt, B., Tamm, C., Weyers, S., & Peik, E. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.011102 · Cited by 200
Long term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Pizzocaro, M., Bregolin, F., Barbieri, P., Rauf, B., Levi, F., & Calonico, D. (2020) · Metrologia · doi:10.1088/1681-7575/ab50e8 · Cited by 63
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
“Some direct fountain clock comparisons have taken place in the past [12–16], but only a few bilateral remote comparisons of optical clocks have been performed so far [17–22].”
Background
Metadata
- Authors
- McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R. J., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., Brown, R. C., Römisch, S., Oates, C. W., Parker, T. E., Fortier, T. M., & Ludlow, A. D.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2019-04-11
- Volume
- 6
- Issue
- 4
- Pages
- 448
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2935935908
- Cited by
- 135
- References
- 26
- FWCI
- 8.22
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.