A Multimodal, SU-8 - Platinum - Polyimide Microelectrode Array for Chronic In Vivo Neurophysiology
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Utilization of polymers as insulator and bulk materials of microelectrode arrays (MEAs) makes the realization of flexible, biocompatible sensors possible, which are suitable for various neurophysiological experiments such as in vivo detection of local field potential changes on the surface of the neocortex or unit activities within the brain tissue. In this paper the microfabrication of a novel, all-flexible, polymer-based MEA is presented. The device consists of a three dimensional sensor configuration with an implantable depth electrode array and brain surface electrodes, allowing the recording of electrocorticographic (ECoG) signals with laminar ones, simultaneously. In vivo recordings were performed in anesthetized rat brain to test the functionality of the device under both acute and chronic conditions. The ECoG electrodes recorded slow-wave thalamocortical oscillations, while the implanted component provided high quality depth recordings. The implants remained viable for detecting action potentials of individual neurons for at least 15 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Steriade, M., Nunez, A., & Amzica, F. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-08-03252.1993 · Cited by 1,903
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“However, in terms of biocompatibility, these are only necessary, but not sufficient conditions, since inert materials can also trigger the foreign body response of the immune system and cause glial scar formation, which can compromise the functionality of the electrodes [9].”
BackgroundAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · cited 1×
“Following the appearance of the first silicon-based micromachined neural implants [1], such devices evolved rapidly and today a great variety of precisely and reproducibly fabricated MEAs are available, which make the recording of potential changes in the extracellular space with high spatial density possible [2–5].”
BackgroundInfluentialHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
The slow (<1 Hz) rhythm of non-REM sleep: a dialogue between three cardinal oscillators
Crunelli, V., & Hughes, S. W. (2010) · Nature Neuroscience · doi:10.1038/nn.2445 · Cited by 435 · cited 1×
“In the hippocampus, unit activities do not follow the oscillation closely, which meets the expectations, since slow waves are supposedly generated by neocortical and thalamic oscillators [45].”
BackgroundThe Human K-Complex Represents an Isolated Cortical Down-State
Cash, S. S., Halgren, E., Dehghani, N., Rossetti, A. O., Thesen, T., Wang, C., Devinsky, O., Kuzniecky, R., Doyle, W., Madsen, J. R., et al. (2009) · Science · doi:10.1126/science.1169626 · Cited by 394 · cited 1×
“This trend was also observed in humans during slow-wave sleep, although with different spatial pattern [46, 47].”
BackgroundSelf-citationMicromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · cited 1×
“Peripheral neurons can be contacted with either implants penetrating into the nerves [15, 16] or cuff electrodes, which can be wrapped around them [17].”
BackgroundCell and protein compatibility of parylene-C surfaces
Chang, T. Y., Yadav, V. G., De Leo, S., Mohedas, A., Rajalingam, B., Chen, C.-L., Selvarasah, S., Dokmeci, M. R., & Khademhosseini, A. (2007) · Langmuir · doi:10.1021/la7017049 · Cited by 320
Origin of Active States in Local Neocortical Networks during Slow Sleep Oscillation
Chauvette, S., Volgushev, M., & Timofeev, I. (2010) · Cerebral Cortex · doi:10.1093/cercor/bhq009 · Cited by 266
Laminar analysis of slow wave activity in humans
Csercsa, R., Dombovári, B., Fabó, D., Wittner, L., Erőss, L., Entz, L., Sólyom, A., Rásonyi, G., Szűcs, A., Kelemen, A., et al. (2010) · Brain · doi:10.1093/brain/awq169 · Cited by 239
Self-citationImplantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Multiple microelectrode-recording system for human intracortical applications
Ulbert, I., Halgren, E., Heit, G., & Karmos, G. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00330-2 · Cited by 173 · cited 1×
“The probe is an upgraded version of the thumbtack-like neural MEA, shown in Fig 1A, which had been successfully used for recording field potentials, multiple unit and single unit activities in behaving and anaesthetized humans [35].”
MethodSelf-citationMetz, S., Bertsch, A., Bertrand, D., & Renaud, P. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.11.021 · Cited by 167
Novel multi-sided, microelectrode arrays for implantable neural applications
Seymour, J. P., Langhals, N. B., Anderson, D. J., & Kipke, D. R. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9512-z · Cited by 95 · cited 1×
“SU-8 photoresist [11], Polyimide (PI) [12] and Parylene C [13, 14] can be employed as bulk and insulator materials of neural sensors.”
Background
Cited by
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
From softening polymers to multimaterial based bioelectronic devices
Ecker, M., Joshi-Imre, A., Modi, R., Frewin, C. L., Garcia-Sandoval, A., Maeng, J., Gutierrez-Heredia, G., Pancrazio, J. J., & Voit, W. E. (2019) · Multifunctional Materials · doi:10.1088/2399-7532/aaed58 · Cited by 34
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18
Metadata
- Authors
- Márton, G., Orbán, G., Kiss, M., Fiáth, R., Pongrácz, A., & Ulbert, I.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-12-18
- Volume
- 10
- Issue
- 12
- Pages
- e0145307
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2206712621
- Cited by
- 35
- References
- 15
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.