The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Determination of 19 Cardiac Troponin I and T Assay 99th Percentile Values from a Common Presumably Healthy Population
Abstract
BACKGROUND: Between-assay comparability of 99th percentiles for cardiac troponin concentrations has not been assessed systematically in a single population for a large number of assays. METHODS: We determined 99th percentiles for 19 cardiac troponin assays in heparin plasma samples from a population of 272 and 252 presumably healthy males and females, respectively. The assays evaluated included 1 cardiac troponin T (cTnT) assay from Roche and 18 cTnI assays from Abbott, Alere, Beckman, bioMerieux, Instrumentation Laboratory, Ortho-Clinical Diagnostics, Singulex, Siemens, and Roche. Five of these assays were categorized as high-sensitivity, 9 as sensitive-contemporary, and 5 as point-of-care (POC) assays. RESULTS: For high-sensitivity cTnI (hs-cTnI) assays 99th percentiles varied from 23 to 58 ng/L. At least 80% of individuals had measurable hs-cTnI, whereas only 25% had measurable high-sensitivity cTnT. All high-sensitivity cardic troponin assays had 99th percentiles that were 1.2–2.4-fold higher in males than females. For the 9 sensitive-contemporary cTnI assays, 99th percentiles varied from 12 to 392 ng/L, and only the Beckman assay gave measurable concentrations in a substantial portion of the population (35% vs ≤6% for the others). Seven of these 9 assays had 1.3–5.0-fold higher 99th percentiles for males than females. For 5 cTnI POC assays, 99th percentiles varied from <10 to 40 ng/L. The Instrumentation Laboratory assay gave measurable results in 27.8% of study participants vs ≤6% for the others. Correlations were generally poor among assays. CONCLUSIONS: Among cardiac troponin assays 99th percentile concentrations appear to differ. High-sensitivity assays provide measurable cardiac troponin results in a substantially greater fraction of presumably healthy individuals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E., Bassand, J.-P., Klein, W., Ohman, M., Lopez Sendon, J. L., Rydén, L., Simoons, M., & Tendera, M. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00804-4 · Cited by 4,821
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687
Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction
Keller, T., Zeller, T., Peetz, D., Tzikas, S., Roth, A., Czyz, E., Bickel, C., Baldus, S., Warnholtz, A., Fröhlich, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0903515 · Cited by 1,150
Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,084
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
Self-citationWu, A. H., Apple, F. S., Gibler, W. B., Jesse, R. L., Warshaw, M. M., & Valdes, R. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.7.1104 · Cited by 662
Self-citationReichlin, T., Schindler, C., Drexler, B., Twerenbold, R., Reiter, M., Zellweger, C., Moehring, B., Ziller, R., Hoeller, R., Rubini Gimenez, M., et al. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.3698 · Cited by 551
Influence of Statistical Method Used on the Resulting Estimate of Normal Range
Reed, A. H., Henry, R. J., & Mason, W. B. (1971) · Clinical Chemistry · doi:10.1093/clinchem/17.4.275 · Cited by 531
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 474
Self-citationReichlin, T., Irfan, A., Twerenbold, R., Reiter, M., Hochholzer, W., Burkhalter, H., Bassetti, S., Steuer, S., Winkler, K., Peter, F., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.023937 · Cited by 460
A New Season for Cardiac Troponin Assays: It’s Time to Keep a Scorecard
Apple, F. S. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.128363 · Cited by 438
Self-citationMulticenter analytical evaluation of a high-sensitivity troponin T assay
Saenger, A. K., Beyrau, R., Braun, S., Cooray, R., Dolci, A., Freidank, H., Giannitsis, E., Gustafson, S., Handy, B., Katus, H., et al. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.12.034 · Cited by 376
Apple, F. S., Quist, H. E., Doyle, P. J., Otto, A. P., & Murakami, M. M. (2003) · Clinical Chemistry · doi:10.1373/49.8.1331 · Cited by 322
Self-citationMingels, A., Jacobs, L., Michielsen, E., Swaanenburg, J., Wodzig, W., & van Dieijen-Visser, M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.106427 · Cited by 295
Influence of Population Selection on the 99th Percentile Reference Value for Cardiac Troponin Assays
Collinson, P. O., Heung, Y. M., Gaze, D., Boa, F., Senior, R., Christenson, R., & Apple, F. S. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.171082 · Cited by 254
Self-citationMueller, M., Biener, M., Vafaie, M., Doerr, S., Keller, T., Blankenberg, S., Katus, H. A., & Giannitsis, E. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.171827 · Cited by 242
Apple, F. S., Pearce, L. A., Smith, S. W., Kaczmarek, J. M., & Murakami, M. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.114728 · Cited by 212
Self-citationVenge, P., Johnston, N., Lindahl, B., & James, S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.05.051 · Cited by 164
Kavsak, P. A., MacRae, A. R., Yerna, M.-J., & Jaffe, A. S. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.116020 · Cited by 164
Apple, F. S., Smith, S. W., Pearce, L. A., Ler, R., & Murakami, M. M. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.097162 · Cited by 163
Self-citationAcute Coronary Syndrome vs Nonspecific Troponin Elevation
Alcalai, R. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.3.276 · Cited by 130
Wilson, S. R., Sabatine, M. S., Braunwald, E., Sloan, S., Murphy, S. A., & Morrow, D. A. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.06.011 · Cited by 99
Apple, F. S., & Jaffe, A. S. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.194985 · Cited by 87
Self-citationCounterpoint: Standardization of Cardiac Troponin I Assays Will Not Occur in My Lifetime
Apple, F. S. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.166165 · Cited by 80
Self-citationApple, F. S., Simpson, P. A., & Murakami, M. M. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2010.05.014 · Cited by 75
Self-citationSerum and Plasma Cardiac Troponin I 99th Percentile Reference Values for 3 2nd-Generation Assays
Apple, F. S., & Murakami, M. M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.087718 · Cited by 44
Self-citationApple, F. S., Smith, S. W., Pearce, L. A., & Murakami, M. M. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.02.030 · Cited by 36
Self-citationKontos, M. C., de Lemos, J. A., Ou, F., Wiviott, S. D., Foody, J. M., Newby, L. K., Chen, A., & Roe, M. T. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.07.022 · Cited by 29
High-Sensitivity Cardiac Troponin for Screening Large Populations of Healthy People: Is There Risk?
Apple, F. S. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.162875 · Cited by 24
Self-citationPoint: Put Simply, Standardization of Cardiac Troponin I Is Complicated
Christenson, R. H., Bunk, D. M., Schimmel, H. G., Tate, J. R., & IFCC Working Group on Standardization of Troponin I (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.166140 · Cited by 23
Third universal definition of myocardial infarction
Thygesen, K. A., Alpert, J. S., Jaffe, A. S., Simoons, M. L., CHAITMAN, B. R., & White, H. D. (2013) · Srce i krvni sudovi · doi:10.5937/siks1301029t · Cited by 20
Collinson, P. O. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.05.035 · Cited by 4
Cited by
Fourth universal definition of myocardial infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., ESC Scientific Document Group, Thygesen, K., Alpert, J. S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy462 · Cited by 5,880
Self-citationFourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., & White, H. D. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1038 · Cited by 4,118
Fourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., & The Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction (2018) · Circulation · doi:10.1161/cir.0000000000000617 · Cited by 3,799
Shah, A. S. V., Anand, A., Sandoval, Y., Lee, K. K., Smith, S. W., Adamson, P. D., Chapman, A. R., Langdon, T., Sandeman, D., Vaswani, A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00391-8 · Cited by 510
Self-citationFourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., & White, H. D. (2018) · Global Heart · doi:10.1016/j.gheart.2018.08.004 · Cited by 460
Metadata
- Authors
- Apple, F. S., Ler, R., & Murakami, M. M.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-11-01
- Volume
- 58
- Issue
- 11
- Pages
- 1574-1581
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2160843187
- Cited by
- 542
- References
- 34
- FWCI
- 33.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.