On the Analysis of Fingertip Photoplethysmogram Signals
Open accessAbstract
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, PPG is a promising technique for early screening of various atherosclerotic pathologies and could be helpful for regular GP-assessment but a full understanding of the diagnostic value of the different features is still lacking. Recent studies emphasise the potential information embedded in the PPG waveform signal and it deserves further attention for its possible applications beyond pulse oximetry and heart-rate calculation. Therefore, this overview discusses different types of artifact added to PPG signal, characteristic features of PPG waveform, and existing indexes to evaluate for diagnoses. Keywords: Photoplethysmography, acceleration plethysmogram, second derivative plethysmogram, digital volume pulse, ageing, artery, autonomic function, blood pressure, cardiovascular, heart rate, pulse wave analysis, vascular disease
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures












![Fig. (13) Typical PPG waveforms show the parameters changes with age [62].](/paper-figures/8ee5a57901c347579a7a5160e4be1526/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-13.jpg)


![Fig. (16) APG waveforms and types of photoplethysmogram [73]. There are different types of APG waveforms. The first APG waveform A (far left) refers to good circulation, whereas the amplitude of b wave is lower than c wave. The last APG waveform G (far right) refers to distinctively bad circulation, whereas the amplitude of c wave is lower than b wave.](/paper-figures/54ec3ef6e18e4116ad4a30b26f4dd445/on-the-analysis-of-fingertip-photoplethysmogram-signals-figure-16.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“| c/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The shape of a clean PPG signal is closely related to the blood pulse wave of the human body25”
From Data quality evaluation in wearable monitoring (2022) · cites this paper as [25]
In the citing paper
“In this case, the pulsatile component of the PPG can be of the order of 1 mV in amplitude [55] although lower amplitudes can be caused by technical factors, such as inappropriate gain control, or physiological factors, such as vasoconstriction [9].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [9]
In the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“While, to the authors’ knowledge, publications that experimentally and explicitly demonstrate the effect of obesity or BMI on the PPG waveform are limited, we will explore works which suggest that there would be a substantial effect [56,59,60,61,62,63,64,65,66,67,68,69,70].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“The ratio b/a has been found to correlate positively to age, while c/a, d/a and e/a have all been correlated negatively to age [29,59].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| e/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“| d/a | Decrease | Takazawa et al., 1998 Elgendi et al., 2012 | [29,59] |”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [59]
In the citing paper
“Furthermore, PPG can be used to index heart rate variability (HRV), blood pressure, oxygen saturation, and cardiac output24, but as of yet have not be widely rolled out in consumer-use devices and therefore data collection other than HR will not be discussed further.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Investigation of Chronic Venous Insufficiency: A Consensus Statement
Nicolaides, A. N. (2000) · Circulation · doi:10.1161/01.cir.102.20.e126 · Cited by 945
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. P. M. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 841
Determination of age-related increases in large artery stiffness by digital pulse contour analysis
Millasseau, S., Kelly, R. P., Ritter, J., & Chowienczyk, P. (2002) · Clinical Science · doi:10.1042/cs1030371 · Cited by 624
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 528
Mobile monitoring with wearable photoplethysmographic biosensors
Asada, H. H., Shaltis, P., Reisner, A., Rhee, S., & Hutchinson, R. C. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213624 · Cited by 466
Gil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH
Hertzman, A. B. (1938) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1938.124.2.328 · Cited by 460
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, K. H. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000269512.82836.c9 · Cited by 450
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365
Noninvasive Assessment of the Digital Volume Pulse
Millasseau, S., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J., Ritter, J. M., & Chowienczyk, P. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 292
27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2005) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2005.845677 · Cited by 288
Lu, S. F., Zhao, H., Ju, K., Shin, K., Lee, M., Shelley, K. H., & Chon, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9103-y · Cited by 284
Bortolotto, L. A., Blacher, J., Kondo, T., Takazawa, K., & Safar, M. E. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00192-2 · Cited by 272
Nakajima, K., TAMURA, T., & Miike, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00066-6 · Cited by 244
The peripheral pulse wave: Information overlooked
Murray, W. B., & Foster, P. A. (1996) · The Journal of Clinical Monitoring · doi:10.1007/bf02077634 · Cited by 231
Predicting Arterial Stiffness From the Digital Volume Pulse Waveform
Alty, S. R., Angarita-Jaimes, N., Millasseau, S., & Chowienczyk, P. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897805 · Cited by 192
PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIA
Dorlas, J. C., & Nijboer, J. A. (1985) · British Journal of Anaesthesia · doi:10.1093/bja/57.5.524 · Cited by 160
The role of air plethysmography in the diagnosis of chronic venous insufficiency
Criado, E., Farber, M. A., Marston, W. A., Daniel, P. F., Burnham, C. B., & Keagy, B. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70231-9 · Cited by 145
Patterns of venous reflux in limbs with skin changes associated with chronic venous insufficiency
Lees, T. A., & Lambert, D. (1993) · British journal of surgery · doi:10.1002/bjs.1800800617 · Cited by 145
The relationship between the photoplethysmographic waveform and systemic vascular resistance
Alian, A. A., Haddadin, A. S., Tantawy, H., Badr, T., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9097-5 · Cited by 136
Journal of Clinical Monitoring and Computing
(2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/10877.1573-2614 · Cited by 134
Hashimoto, J., Chonan, K., Aoki, Y., Nishimura, T., Ohkubo, T., Hozawa, A., Suzuki, M., Matsubara, M., Michimata, M., Araki, T., et al. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00021 · Cited by 122
Seitsonen, E. R. J., Korhonen, I. K. J., Van Gils, M. J., Huiku, M., Lötjönen, J. M. P., Korttila, K. T., & Yli‐Hankala, A. M. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00654.x · Cited by 120
Imanaga, I., Hara, H., KOYANAGI, S., & TANAKA, K. (1998) · Japanese Heart Journal · doi:10.1536/ihj.39.775 · Cited by 118
Noninvasive cardiac output estimation using a novel photoplethysmogram index
Wang, L., Pickwell‐MacPherson, E., Liang, Y. P., & Zhang, Y. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333091 · Cited by 117
Photoplethysmography and nociception
Korhonen, I., & Yli‐Hankala, A. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02026.x · Cited by 105
Otsuka, T., Kawada, T., Katsumata, M., & Ibuki, C. (2006) · Circulation Journal · doi:10.1253/circj.70.304 · Cited by 103
Nilsson, L. M., Johansson, A., & Kálmán, S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00721.x · Cited by 78
Towards Using Photo-Plethysmogram Amplitude to Measure Blood Pressure During Sleep
Chua, E. C.-P., Redmond, S. J., McDarby, G., & Heneghan, C. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9882-z · Cited by 77
Effects of Physical Training on Peripheral Vascular Disease: A Controlled Study
Mannarino, E., Pasqualini, L., Menna, M. B., Maragoni, G., & Orlandi, U. (1989) · Angiology · doi:10.1177/000331978904000102 · Cited by 76
Heartbeat monitoring alert via SMS
Jubadi, W. M., & Sahak, S. (2009) · IEEE Symposium on Industrial Electronics & Applications (ISIEA) · doi:10.1109/isiea.2009.5356491 · Cited by 71
Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse
Padilla, J. M. S., BERJANO, E. J., Sáiz, J., Fácila, L., Díaz, P. T., & Merce, S. (2006) · Cited by 70
Second Derivative of Photoplethysmography for Estimating Vascular Aging
Baek, H. J., Kim, J. S., Kim, Y. S., Lee, H. B., & Park, K. S. (2007) · IEEE International Conference on Information Technology and Applications in Biomedicine · doi:10.1109/itab.2007.4407346 · Cited by 69
Optical Techniques in the Assessment of Peripheral Arterial Disease
Alnaeb, M. E., Alobaid, N., Seifalian, A. M., Mikhailidis, D. P., & Hamilton, G. (2006) · Current Vascular Pharmacology · doi:10.2174/157016107779317242 · Cited by 69
Cardiac resynchronization therapy optimization by finger plethysmography
Butter, C., Stellbrink, C., Belalcazar, A., Villalta, D., Schlegl, M., Sinha, A. M., CUESTA, F., & Reister, C. A. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.07.002 · Cited by 66
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Chua, C. P., & Heneghan, C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259612 · Cited by 65
Lawrence, A. A., Latty, E. M., Chivers, M. L., & Bailey, J. M. (2005) · Archives of Sexual Behavior · doi:10.1007/s10508-005-1792-z · Cited by 63
(2008) · Journal of Medical and Biological Engineering · Cited by 57
Using The Morphology of Photoplethysmogram Peaks to Detect Changes in Posture
Linder, S. P., Wendelken, S., Wei, E., & McGrath, S. P. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9015-2 · Cited by 56
Photoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases
Rubīns, U., Grabovskis, A., Grūbe, J., & Kukulis, I. (2008) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-69367-3_85 · Cited by 55
Weingarten, M. S., Czeredarczuk, M., Scovell, S. D., Branas, C. C., Mignogna, G. M., & Wolferth, C. C. (1996) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(96)70008-3 · Cited by 52
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 50
Ubbink, D. T. (2004) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2004.01.031 · Cited by 46
The finger volume pulse and assessment of arterial properties
Avolio, A. P. (2002) · Journal of Hypertension · doi:10.1097/00004872-200212000-00007 · Cited by 45
The vasomotor components in the vascular reactions in the finger to cold
Hertzman, A. B., & Roth, L. W. (1942) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1942.136.4.669 · Cited by 39
Ushiroyama, T., Kajimoto, Y., Sakuma, K., & Ueki, M. (2005) · Institutional Repositories DataBase (IRDB) · doi:10.57371/00000405 · Cited by 37
Assessment of relationships between blood pressure, pulse wave velocity and digital volume pulse
Padilla, Berjano, Sáiz, Facila, Diaz, & Merce (2006) · Computing in cardiology · Cited by 37
Hahn, M., Hahn, C., Jünger, M., Steins, A., Zuder, D., Klyscz, T., Büchtemann, A., Rassner, G., & Blazek, V. (1999) · Microvascular Research · doi:10.1006/mvre.1998.2130 · Cited by 33
An overview of non-contact photoplethysmography
Demirezen, H., & Erdem, Ç. E. (2017) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2017.7960176 · Cited by 31
Automatic Ankle Pressure Measurements Using PPG in Ankle-brachial Pressure Index Determination
Jönsson, B., Laurent, C., Eneling, M., Skau, T., & Lindberg, L.-G. (2005) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2005.05.012 · Cited by 29
Foster, A., NEUMANN, C. G., & Rovenstine, E. A. (1945) · Anesthesiology · doi:10.1097/00000542-194505000-00004 · Cited by 29
An assessment of blood vessel vasoactivity using photoplethysmography.
Evans, M., & Geddes, L. A. (1988) · PubMed · Cited by 28
DeSanctis, M. T., Cesarone, M. R., INCANDELA, L., Belcaro, G., & Acerbi, G. (2002) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/107424840200700102 · Cited by 25
Peripheral Hemodynamics Evaluated by Acceleration Plethysmography in Workers Exposed to Lead.
Aiba, Y., Ohshiba, S., Horiguchi, S., Morioka, I., Miyashita, K., Kiyota, I., Endo, G., Takada, H., & Iwata, H. (1999) · Industrial Health · doi:10.2486/indhealth.37.3 · Cited by 23
KIMURA, Y., Takamatsu, K., Fujii, A., Suzuki, M., Chikada, N., Tanada, R., Kume, Y., & Satō, H. (2007) · Journal of obstetrics and gynaecology research · doi:10.1111/j.1447-0756.2007.00531.x · Cited by 23
HEART RATE VARIABILITY MEASUREMENT USING THE SECOND DERIVATIVE PHOTOPLETHYSMOGRAM
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · International Conference on Bio-inspired Systems and Signal Processing · doi:10.5220/0002743300820087 · Cited by 22
Self-citationThe use of automated strain gauge plethysmography in the diagnosis of deep vein thrombosis
Maskell, N. A., Cooke, S., Jones, D. J. M., PRIOR, J. G., & Butland, R. J. (2002) · British Journal of Radiology · doi:10.1259/bjr.75.896.750648 · Cited by 22
Strain gauge plethysmography for the detection of deep venous thrombosis
Croal, S. A., Birkmyre, J., McNally, M., Hamilton, C., & Mollan, R. A. B. (1993) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(93)90043-x · Cited by 21
Dicrotic notch detection using wavelet transform analysis
Antonelli, L. T., Ohley, W. J., & Khamlach, R. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1994.415400 · Cited by 20
Changes in the Photoplethysmogram Waveform After Exercise
Poon, C. C. Y., Teng, X. F., Wong, Y. M., Zhang, C., & Zhang, Y. (2006) · IEEE/EMBS International Summer School on Medical Devices and Biosensors (ISSS-MDBS) · doi:10.1109/issmd.2004.1689576 · Cited by 19
Classification of Acceleration Plethysmogram Using Self-Organizing Map
Nousou, N., Urase, S., Maniwa, Y., Fujimura, K., & Fukui, Y. (2006) · International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS) · doi:10.1109/ispacs.2006.364747 · Cited by 19
Tokutaka, H., Maniwa, Y., Gonda, E., Yamamoto, M., Kakihara, T., Kurata, M., Fujimura, K., Li, S., & Ohkita, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02397-2_35 · Cited by 17
Blood-flow indices in amputee and control limbs by mutual electrical impedance plethysmography
Nyboer, J., Murray, P., & Sedensky, J. A. (1974) · American Heart Journal · doi:10.1016/0002-8703(74)90414-1 · Cited by 17
Cold sensitivity of the hand in arterial occlusive disease.
Hirai, M. (1979) · PubMed · Cited by 16
Applying the APG to measure Heart Rate Variability
Elgendi, M., Jonkman, M., & Boer, F. D. (2010) · doi:10.1109/iccae.2010.5452042 · Cited by 16
Self-citationEvaluating the surgeon's stress when using surgical assistant robots
Taniguchi, K., Nishikawa, A., Nakagoe, H., Sugino, T., Sekimoto, M., Okada, K., Takiguchi, S., Monden, M., & Miyazaki, F. (2007) · IEEE International Symposium on Robot and Human Interactive Communication · doi:10.1109/roman.2007.4415210 · Cited by 16
Rimaud, D., Boissier, C., & Calmels, P. (2008) · Journal of Spinal Cord Medicine · doi:10.1080/10790268.2008.11760713 · Cited by 14
Measurement of a-a Intervals at Rest in the Second Derivative Plethysmogram
Elgendi, M., Jonkman, M., & Boer, F. D. (2009) · Cited by 13
Self-citationRELATIONSHIP BETWEEN ACCELERATED PLETHYSMOGRAM, BLOOD PRESSURE AND ARTERIOLAR ELASTICITY
Homma, S. T., Ito, S., Koto, T., & IKEGAMI, H. (1992) · 体力科學 · doi:10.7600/jspfsm1949.41.98 · Cited by 13
Automated Bedside Measurement of Penile Blood Flow Using Pulse-Volume Plethysmography
Unno, N., Inuzuka, K., Mitsuoka, H., Ishimaru, K., Sagara, D., & Konno, H. (2006) · Surgery Today · doi:10.1007/s00595-005-3139-8 · Cited by 12
Maximal hand blood flow in hypertensive and normal subjects
Horwitz, D. L., & Patel, D. J. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90386-8 · Cited by 12
Continuous Limb Blood Flow Estimation in the Newborn Using Electrical Impedance Plethysmography
Costeloe, K., & Rolfe, P. J. (1980) · Pediatric Research · doi:10.1203/00006450-198009000-00007 · Cited by 12
Validation of a continuous penile blood-flow measurement by pulse-volume-plethysmography
Lavoisier, P., Barbe, R., & Gally, M. (2002) · International Journal of Impotence Research · doi:10.1038/sj.ijir.3900840 · Cited by 9
Assessment of venous function using photoplethysmography
Moore, D. J., Maher, T., Kingston, V., & Shanik, G. D. (1982) · Irish Journal of Medical Science (1971 -) · doi:10.1007/bf02940210 · Cited by 8
Fujimoto, Y., & Yamaguchi, T. (2008) · IFAC Proceedings Volumes · doi:10.3182/20080706-5-kr-1001.01393 · Cited by 7
EFFECT OF RAPID DISTENSION OF LARGE ARTERIES AND VEINS ON THE VASCULAR TONE OF THE FINGERS
Heyman, F., & Ahlberg, N. E. (1968) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1968.tb10487.x · Cited by 7
Cesarone, M. R., Sanctis, M. T. D., INCANDELA, L., Belcaro, G., GRIFFIN, M. B., & Cacchio, M. (2001) · Angiology · doi:10.1177/000331970105202s02 · Cited by 7
Kawakami, Y., Menkes, H. A., & DuBois, A. B. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106337 · Cited by 6
Iokibe, T., KURIHARA, M., Maniwa, Y., Ohta, S., UCHIDA, I., Amata, M., & YAMAMOTO, M. (2003) · Journal of Japan Society for Fuzzy Theory and Intelligent Informatics · doi:10.3156/jsoft.15.565 · Cited by 5
Cowbird Research and Measuring Pulsatile Diffusing Capacity
Hyde, R. W. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.6.2112010 · Cited by 4
Continuous Blood Pressure Monitoring using ECG and Finger Photoplethysmogram
Chua, C. P., & Heneghan, C. (2006) · Conference proceedings · doi:10.1109/iembs.2006.4398605 · Cited by 3
The vasomotor components in the vascular reactions in the finger to cold
(1943) · American Heart Journal · doi:10.1016/s0002-8703(43)90408-9 · Cited by 1
Research works printed but not linked: 3
- [59]Takazawa KTN Fujita M Matsuoka O Saiki T Aikawa M Tamura S Ibukiyama C Assessment of vasocative agents and vascular aging by the second derivative of photoplethysmogram waveform Hypertension 1998 32 365 70 9719069
- [80]Elgendi M Jonkman M De Boer F Fred A Filipe J Gamboa h Heart Rate Variability and Acceleration Plethysmogram measured at rest Biomedical Engineering Systems and Technologies: 2011 Springer 266 77
- [81]Tokutaka H MY Gonda E Yamamoto M Construction of a General Physical Condition Judgment System Using Acceleration Plethysmogram Pulse-Wave Analysis 2009 Berlin/Heidelberg Springer 5629 307 15
Cited by
Sorted by citations
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Multifunctional materials for implantable and wearable photonic healthcare devices
Lee, G., Moon, H., Kim, H., Lee, G. H., Kwon, W., Yoo, S., Myung, D. J., Yun, S. H., Bao, Z., & Hahn, S. K. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0167-3 · Cited by 683
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
The use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Self-citationCuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Metadata
- Authors
- Elgendi, M.
- Affiliations
- Charles Darwin University (AU)
- Corresponding author
- Elgendi, Mohamed
- ORCID
- Elgendi, Mohamed
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-06-01
- Volume
- 8
- Issue
- 1
- Pages
- 14-25
- ISSN
- 1573-403X (ISSN-L)
- PMC
- PMC3394104
- OpenAlex
- W1981918735
- Cited by
- 1,206
- References
- 88
- Citations by year
- 2026: 120 · 2025: 106 · 2024: 116 · 2023: 109 · 2022: 130 · 2021: 114 · 2020: 118 · 2019: 118 · 2018: 86 · 2017: 65 · 2016: 46 · 2015: 42 · 2014: 24 · 2013: 11 · 2012: 1
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Current Cardiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DR-NTU (Nanyang Technological University) (submittedVersion)
- Funders
- Univerzita Karlova v Praze
- Australian Government
- Charles Darwin University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, digital volume pulse, aging, autonomic function, blood pressure, heart rate, pulse wave analysis, cardiovascular disease, vascular disease, atherosclerosis screening
- MeSH terms
- Fingers, Hemodynamics, Humans, Skin, Artifacts, Photoplethysmography, Pulse Wave Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review