Assessment of risk for severe hypoglycemia among adults with IDDM: validation of the low blood glucose index.
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate the clinical/research utility of the low blood glucose index (LBGI), a measure of the risk of severe hypoglycemia (SH), based on self-monitoring of blood glucose (SMBG). RESEARCH DESIGN AND METHODS: There were 96 adults with IDDM (mean age 35+/-8 years, duration of diabetes 16+/-10 years, HbA1 8.6+/-1.8%), 43 of whom had a recent history of SH (53 did not), who used memory meters for 135+/-53 SMBG readings over a month, and then for the next 6 months recorded occurrence of SH. The SMBG data were mathematically transformed, and an LBGI was computed for each patient. RESULTS: The two patient groups did not differ with respect to HbA1, insulin units per day, average blood glucose (BG) and BG variability. Patients with history of SH demonstrated a higher LBGI (P < 0.0005) and a trend to be older with longer diabetes duration. Analysis of odds for future SH classified patients into low- (LBGI <2.5), moderate- (LBGI 2.5-5), and high- (LBGI >5) risk groups. Over the following 6 months low-, moderate-, and high-risk patients reported 0.4, 2.3, and 5.2 SH episodes, respectively (P = 0.001). The frequency of future SH was predicted by the LBGI and history of SH (R2 = 40%), while HbA1, age, duration of diabetes, and BG variability were not significant predictors. CONCLUSIONS: LBGI provides an accurate assessment of risk of SH. In the traditional relationship history of SH-to-future SH, LBGI may be the missing link that reflects present risk. Because it is based on SMBG records automatically stored by many reflectance meters, the LBGI is an effective and clinically useful on-line indicator for SH risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationCryer, P. E., Davis, S. N., & Shamoon, H. (2003) · Diabetes Care · doi:10.2337/diacare.26.6.1902 · Cited by 1,160
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Heinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“The LBGI, which is based on the left branch of the BG Risk Function r(BG) has been validated as an excellent predictor of future significant hypoglycemia [186], [187].”
Self-citationHovorka, R., Allen, J. M., Elleri, D., Chassin, L. J., Harris, J., Xing, D., Kollman, C., Hovorka, T., Larsen, A. M. F., Nodale, M., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61998-x · Cited by 450
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes
Monnier, L., Colette, C., Wojtusciszyn, A., Dejager, S., Renard, E., Molinari, N., & Owens, D. R. (2017) · Diabetes Care · doi:10.2337/dc16-1769 · Cited by 390
Ryan, E. A., Shandro, T., Green, K., Paty, B. W., Senior, P. A., Bigam, D., Shapiro, A. M. J., & Vantyghem, M.-C. (2004) · Diabetes · doi:10.2337/diabetes.53.4.955 · Cited by 343
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Evaluation of a New Measure of Blood Glucose Variability in Diabetes
Kovatchev, B. P., Otto, E., Cox, D., Gonder-Frederick, L., & Clarke, W. (2006) · Diabetes Care · doi:10.2337/dc06-1085 · Cited by 333
Self-citationRodbard, D. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0132 · Cited by 310
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0051 · Cited by 307
Klonoff, D. C., Wang, J., Rodbard, D., Kohn, M. A., Li, C., Liepmann, D., Kerr, D., Ahn, D., Peters, A. L., Umpierrez, G. E., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221085273 · Cited by 295
Self-citationMetrics for glycaemic control - from HbA1c to continuous glucose monitoring
Kovatchev, B. P. (2017) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2017.3 · Cited by 272
Self-citationGlucose Variability: Timing, Risk Analysis, and Relationship to Hypoglycemia in Diabetes
Kovatchev, B., & Cobelli, C. (2016) · Diabetes Care · doi:10.2337/dc15-2035 · Cited by 255
Self-citationAbnormal Heart Rate Characteristics Preceding Neonatal Sepsis and Sepsis-Like Illness
Griffin, M. P., O'Shea, T. M., Bissonette, E. A., Harrell, F. E., Lake, D. E., & Moorman, J. R. (2003) · Pediatric Research · doi:10.1203/01.pdr.0000064904.05313.d2 · Cited by 250
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
“We used the low blood glucose index to assess the duration and extent of hypoglycaemia, calculated as an average of transformed glucose measurements progressively increasing at low glucose levels.”
MethodChoudhary, P., Rickels, M. R., Senior, P. A., Vantyghem, M.-C., Maffi, P., Kay, T. W., Keymeulen, B., Inagaki, N., Saudek, F., Lehmann, R., et al. (2015) · Diabetes Care · doi:10.2337/dc15-0090 · Cited by 233
New and Improved Methods to Characterize Glycemic Variability Using Continuous Glucose Monitoring
Rodbard, D. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0015 · Cited by 232
Kovatchev, B. P., Clarke, W. L., Breton, M., Brayman, K., & McCall, A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.849 · Cited by 201
Self-citationFonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
“…hypoglycemic levels Mathematical formula may need further validation Concept needs to be shown to relate to diabetes outcomes in clinical trials Kovatchev et al 1998 (59) Rodbard 2009 (54) Fabris et al 2015 (60) HBGI Weights risk according to more severe hyperglycemic levels Mathematical…”
BackgroundWright, L. A.-C., & Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0029 · Cited by 178
Kovatchev, B. P., Renard, E., Cobelli, C., Zisser, H. C., Keith-Hynes, P., Anderson, S. M., Brown, S. A., Chernavvsky, D. R., Breton, M. D., Mize, L. B., et al. (2014) · Diabetes Care · doi:10.2337/dc13-2076 · Cited by 178
Self-citationReinforcement learning application in diabetes blood glucose control: A systematic review
Tejedor, M., Woldaregay, A. Z., & Godtliebsen, F. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101836 · Cited by 172
Stewart, Z. A., Wilinska, M. E., Hartnell, S., O’Neil, L. K., Rayman, G., Scott, E. M., Barnard, K., Farrington, C., Hovorka, R., & Murphy, H. R. (2018) · Diabetes Care · doi:10.2337/dc17-2534 · Cited by 168
Bergenstal, R. M., Ahmann, A. J., Bailey, T., Beck, R. W., Bissen, J., Buckingham, B., Deeb, L., Dolin, R. H., Garg, S. K., Goland, R., et al. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700234 · Cited by 166
Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 Diabetes
Elleri, D., Allen, J. M., Kumareswaran, K., Leelarathna, L., Nodale, M., Caldwell, K., Cheng, P., Kollman, C., Haidar, A., Murphy, H. R., et al. (2013) · Diabetes Care · doi:10.2337/dc12-0816 · Cited by 158
Glycemic variability: how to measure and its clinical implication for type 2 diabetes
Umpierrez, G. E., & P. Kovatchev, B. (2018) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2018.09.010 · Cited by 148
Prediction of Severe Hypoglycemia
Cox, D. J., Gonder-Frederick, L., Ritterband, L., Clarke, W., & Kovatchev, B. P. (2007) · Diabetes Care · doi:10.2337/dc06-1386 · Cited by 129
Self-citationBreton, M. D., Brown, S. A., Karvetski, C. H., Kollar, L., Topchyan, K. A., Anderson, S. M., & Kovatchev, B. P. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0333 · Cited by 128
“The system then predicts glycemic excursions 30–45 min ahead and computes a predicted hypoglycemic and hyperglycemic risks.”
Self-citationBenhamou, P.-Y., Melki, V., Boizel, R., Perreal, F., Quesada, J.-L., Bessieres-Lacombe, S., Bosson, J.-L., Halimi, S., & Hanaire, H. (2007) · Diabetes & Metabolism · doi:10.1016/j.diabet.2007.01.002 · Cited by 118
Rama Chandran, S., Tay, W. L., Lye, W. K., Lim, L. L., Ratnasingam, J., Tan, A. T. B., & S.L. Gardner, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0388 · Cited by 114
Bosi, E., Scavini, M., Ceriello, A., Cucinotta, D., Tiengo, A., Marino, R., Bonizzoni, E., Giorgino, F., & on behalf of the PRISMA Study Group (2013) · Diabetes Care · doi:10.2337/dc13-0092 · Cited by 105
Visentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103
Self-citationFirst use of model predictive control in outpatient wearable artificial pancreas
Del Favero, S., Bruttomesso, D., Di Palma, F., Lanzola, G., Visentin, R., Filippi, A., Scotton, R., Toffanin, C., Messori, M., Scarpellini, S., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1631 · Cited by 103
Self-citationValue of Self-Monitoring Blood Glucose Pattern Analysis in Improving Diabetes Outcomes
Parkin, C. G., & Davidson, J. A. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300314 · Cited by 96
Real-world assessments of mySugr mobile health app
Debong, F., Mayer, H., & Kober, J. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0019 · Cited by 95
Manohar, C., Levine, J. A., Nandy, D. K., Saad, A., Dalla Man, C., McCrady-Spitzer, S. K., Basu, R., Cobelli, C., Carter, R. E., Basu, A., et al. (2012) · Diabetes Care · doi:10.2337/dc11-2381 · Cited by 89
Rodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0440 · Cited by 75
Schachinger, H., Hegar, K., Hermanns, N., Straumann, M., Keller, U., Fehm-Wolfsdorf, G., Berger, W., & Cox, D. (2005) · Journal of Behavioral Medicine · doi:10.1007/s10865-005-9026-3 · Cited by 73
“Blood glucose accuracy index (Clarke et al., 1987; Cox et al., 1989), detection of low ( < 4 mmol/L) and high ( > 10 mmol/L) blood glucose levels, as well as low and high blood glucose risk index (Cox et al., 1994b; Kovatchev et al., 1998) were calculated according to the published standards.”
MethodSelf-citationAnderson, S. M., Buckingham, B. A., Breton, M. D., Robic, J. L., Barnett, C. L., Wakeman, C. A., Oliveri, M. C., Brown, S. A., Ly, T. T., Clinton, P. K., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0018 · Cited by 68
Self-citationCosson, E., Hamo-Tchatchouang, E., Dufaitre-Patouraux, L., Attali, J.-R., Pariès, J., & Schaepelynck-Bélicar, P. (2009) · Diabetes & Metabolism · doi:10.1016/j.diabet.2009.02.006 · Cited by 57
Are risk indices derived from CGM interchangeable with SMBG-Based indices?
Fabris, C., Patek, S. D., & Breton, M. D. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815599177 · Cited by 52
Hypoglycemia preceding fatal car collisions
Cox, D. J., Kovatchev, B., Vandecar, K., Gonder-Frederick, L., Ritterband, L., & Clarke, W. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1836 · Cited by 48
Self-citationDeveloping the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Self-citationBeck, R. W., Bergenstal, R. M., Riddlesworth, T. D., & Kollman, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0362 · Cited by 42
Significance of Glycemic Variability in Diabetes Mellitus
Kusunoki, Y., Konishi, K., Tsunoda, T., & Koyama, H. (2022) · Internal Medicine · doi:10.2169/internalmedicine.8424-21 · Cited by 40
Chow, L. S., Zmora, R., Ma, S., Seaquist, E. R., & Schreiner, P. J. (2018) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2018-000527 · Cited by 37
Visentin, R., Giegerich, C., Jäger, R., Dahmen, R., Boss, A., Grant, M., Dalla Man, C., Cobelli, C., & Klabunde, T. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0128 · Cited by 36
González-Molero, I., Domínguez-López, M., Guerrero, M., Carreira, M., Caballero, F., Rubio-Martín, E., Linares, F., Cardona, I., Anarte, M. T., de Adana, M. S. R., et al. (2012) · Journal of Telemedicine and Telecare · doi:10.1258/jtt.2012.120103 · Cited by 24
Visentin, R., Schiavon, M., Giegerich, C., Klabunde, T., Man, C. D., & Cobelli, C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2897851 · Cited by 22
“Gla-100 in terms of percent time in target 70–180 mg/dL (Tt), tight target 80–140 mg/dL, (Ttt), below 70 mg/dL (Tb), above 180 mg/dL (Ta), BG mean (MBG) and standard deviation (SD), low and high BG indexes (LBGI, HBGI) [24], [25], and hourly risk range (HRR) [26].”
BackgroundClinical impact of blood glucose monitoring accuracy: an in-silico study
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710474 · Cited by 22
Kovatchev, B., Umpierrez, G., DiGenio, A., Zhou, R., & Inzucchi, S. E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815587014 · Cited by 18
Self-citationThe financial impact of inaccurate blood glucose monitoring systems
Fortwaengler, K., Campos-Náñez, E., Parkin, C. G., & Breton, M. D. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817731423 · Cited by 17
Metadata
- Authors
- Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., Young-Hyman, D., Schlundt, D., & Clarke, W.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 1998-11-01
- Volume
- 21
- Issue
- 11
- Pages
- 1870-1875
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2062082544
- Cited by
- 310
- References
- 0
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.