Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications
Open accessThe DOI matches its Crossref record; 138 of the 138 references it cites were found in a registry or an index.
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) is an imaging technique based on light scattering. PS-OCT performs rapid two- and three-dimensional imaging of transparent and translucent samples with micrometer scale resolution. PS-OCT provides image contrast based on the polarization state of backscattered light and has been applied in many biomedical fields as well as in non-medical fields. Thereby, the polarimetric approach enabled imaging with enhanced contrast compared to standard OCT and the quantitative assessment of sample polarization properties. In this article, the basic methodological principles, the state of the art of PS-OCT technologies, and important applications of the technique are reviewed in a concise yet comprehensive way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
A New Calculus for the Treatment of Optical SystemsI Description and Discussion of the Calculus
Jones, R. C. (1941) · Journal of the Optical Society of America · doi:10.1364/josa.31.000488 · Cited by 1,907
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212 · cited 3×
“From the interference signal in the time or spectral domain, the axial position of scattering structures within the sample can be reconstructed [4,5].”
BackgroundIn vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913 · cited 1×
“Most modern OCT systems rely on frequency (or Fourier) domain detection of the interference signal [5,31].”
BackgroundState-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906 · cited 1×
“OCT is most established in ophthalmology, where it has become a standard diagnostic method in everyday clinical routine [130].”
Methodde Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883 · cited 4×
“(a–c) First published PS-OCT images (adapted with permission from [8], Optical Society of America, 1997) showing birefringence of bovine tendon.”
BackgroundMethodInfluentialOptical Coherence Tomography: Technology and Applications
(2008) · Biological and Medical Physics, Biomedical Engineering · doi:10.1007/978-3-540-77550-8 · Cited by 706
Glaucoma is second leading cause of blindness globally.
Kingman, S. (2004) · Europe PMC (PubMed Central) · Cited by 617
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582 · cited 3×
“The first PS-OCT prototypes provided axial scan rates on the order of several hertz [8,13,14].”
BackgroundEye-length measurement by interferometry with partially coherent light
Fercher, A. F., Mengedoht, K., & Werner, W. (1988) · Optics Letters · doi:10.1364/ol.13.000186 · Cited by 516 · cited 3×
“From the interference signal in the time or spectral domain, the axial position of scattering structures within the sample can be reconstructed [4,5].”
BackgroundOptical coherence tomography today: speed, contrast, and multimodality
Drexler, W., Liu, M., Kumar, A., Kamali, T., Unterhuber, A., & Leitgeb, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.071412 · Cited by 473 · cited 1×
“OCT is a rapid imaging method providing 3D data comprising up to several millions of axial scans within few seconds [6].”
MethodPolarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454 · cited 1×
“While other review papers provided a more in-depth discussion of the physical principles of the technique [9,10], this article is particularly focusing on applications of PS-OCT.”
BackgroundWeinreb, R. N. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070060105058 · Cited by 449 · cited 1×
“Since the RNFL is damaged in glaucoma—the second leading cause of blindness worldwide [132]—and since RNFL birefringence is connected to layer integrity [133,134], the polarization properties of the RNFL were investigated as potential diagnostic markers for glaucoma.”
BackgroundOCT for glaucoma diagnosis, screening and detection of glaucoma progression
Bussel, I. I., Wollstein, G., & Schuman, J. S. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-304326 · Cited by 441 · cited 1×
“Peripapillary RNFL thickness is currently a key OCT parameter for glaucoma diagnostics in state-of-the-art clinical routine [136].”
BackgroundReview of polarization sensitive optical coherence tomography and Stokes vector determination
de Boer, J. F., & Milner, T. E. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483879 · Cited by 440 · cited 2×
“While other review papers provided a more in-depth discussion of the physical principles of the technique [9,10], this article is particularly focusing on applications of PS-OCT.”
BackgroundHitzenberger, C., Goetzinger, E., Sticker, M., Pircher, M., & Fercher, A. (2001) · Optics Express · doi:10.1364/oe.9.000780 · Cited by 391 · cited 5×
“(a–c) PS-OCT images of ex vivo chicken myocardium (adapted with permission from [14], Optical Society of America, 2001).”
BackgroundInfluentialPolarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384 · cited 3×
“The polarization state of a light beam can be affected by interaction with optical components or sample structures [7].”
BackgroundInfluentialStokes vectors, Mueller matrices, and polarized scattered light
Bickel, W. S., & Bailey, W. M. (1985) · American Journal of Physics · doi:10.1119/1.14202 · Cited by 337 · cited 2×
“Analogously, real-valued 4 × 4 matrices—so-called Müller matrices (M)—are used to describe the interaction of Stokes vectors with optical elements by the Stokes–Müller formalism: Sout = MSin (see Figure 2d) [12].”
BackgroundMethodFried, D., Xie, J., Shafi, S., Featherstone, J. D. B., Breunig, T. M., & Le, C. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1509752 · Cited by 331
Stifter, D. (2007) · Applied Physics B · doi:10.1007/s00340-007-2743-2 · Cited by 303 · cited 1×
“Its sensitivity for microstructural changes affecting sample polarization properties along with its 3D imaging capabilities made PS-OCT also an interesting modality for materials science and nondestructive testing applications [236].”
BackgroundHigh-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin
Saxer, C. E., de Boer, J. F., Park, B. H., Zhao, Y., Chen, Z., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.001355 · Cited by 302 · cited 2×
“From the polarization states detected at the output of the interferometer, depth-resolved Stokes vectors can be computed [64,65].”
BackgroundMethodRetinal pigment epithelium segmentation by polarization sensitive optical coherence tomography
Götzinger, E., Pircher, M., Geitzenauer, W., Ahlers, C., Baumann, B., Michels, S., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2008) · Optics Express · doi:10.1364/oe.16.016410 · Cited by 294 · cited 21×
“In DOPU images, DOPU values at every spatial coordinate are color-coded.”
BackgroundMethodSelf-citationPolarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288 · cited 1×
“Also PS-OCT has been successfully applied for ophthalmic imaging using experimental prototypes [131].”
MethodBirefringence characterization of biological tissue by use of optical coherence tomography
Everett, M. J., Schoenenberger, K., Colston, B. W., & Da Silva, L. B. (1998) · Optics Letters · doi:10.1364/ol.23.000228 · Cited by 269 · cited 1×
“These Jones vectors enable the calculation of the sample’s birefringent properties, namely of phase retardation δ [13,39] and fast birefringent axis orientation θ [14] as well as sample reflectivity R: R ∝ A(2)H + A 2 V (6)”
Backgroundde Boer, J. F., Milner, T. E., & Nelson, J. S. (1999) · Optics Letters · doi:10.1364/ol.24.000300 · Cited by 261
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Park, B. H., Saxer, C., Srinivas, S. M., Nelson, J. S., & de Boer, J. F. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1413208 · Cited by 256 · cited 1×
“By computing this angle between the Stokes vectors at the sample surface and those within the tissue, cumulative phase retardation can be computed at any sample position [66,67].”
BackgroundPolarization–Sensitive Optical Coherence Tomography of Dental Structures
Baumgartner, A., Dichtl, S., Hitzenberger, C. K., Sattmann, H., Robl, B., Moritz, A., Fercher, A. F., & Sperr, W. (2000) · Caries Research · doi:10.1159/000016571 · Cited by 235 · cited 1×
“(a–c) PS-OCT tomograms of a carious lesion in enamel at the distal surface of a human molar (adapted with permission from [209], Karger Publishers, 1999).”
BackgroundDetection of Glaucoma With Scanning Laser Polarimetry
Weinreb, R. N. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.12.1583 · Cited by 231
Nadkarni, S. K., Pierce, M. C., Park, B. H., de Boer, J. F., Whittaker, P., Bouma, B. E., Bressner, J. E., Halpern, E., Houser, S. L., & Tearney, G. J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.11.040 · Cited by 223 · cited 4×
“(g–r) PS-OCT images of fibrous plaques (adapted with permission from [205], Elsevier, 2007).”
BackgroundInfluentialCense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-1160 · Cited by 221 · cited 1×
“After initial experiments in the primate retina [140], RNFL birefringence was measured in vivo in the human eye by performing circular scans around the optic nerve head [79,141].”
MethodHigh-speed OCT light sources and systems [Invited]
Klein, T., & Huber, R. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000828 · Cited by 220
High speed spectral domain polarization sensitive optical coherence tomography of the human retina
Götzinger, E., Pircher, M., & Hitzenberger, C. K. (2005) · Optics Express · doi:10.1364/opex.13.010217 · Cited by 217 · cited 1×
“First high-speed PS-OCT systems with spectrometer-based detection provided scan rates of several tens of A-scans per second [41,68].”
BackgroundPolarization effects in optical coherence tomography of various biological tissues
de Boer, J. F., Srinivas, S. M., Park, B. H., Pham, T. H., Chen, Z., Milner, T. E., & Nelson, J. S. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796347 · Cited by 200 · cited 1×
“Also nerve fibers in cerebral white matter or in peripheral nerves may be imaged by PS-OCT based on their birefringence [223].”
BackgroundMorphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography
Mogensen, M., Morsy, H. A., Thrane, L., & Jemec, G. B. E. (2008) · Dermatology · doi:10.1159/000118508 · Cited by 183 · cited 1×
“Using PS-OCT, dermal layers with different scattering and polarization properties can be observed, including stratum corneum, dermis, and epidermis (Figure 7) [50,64,172,173].”
BackgroundWavelength-tuning interferometry of intraocular distances
Lexer, F., Hitzenberger, C. K., Fercher, A. F., & Kulhavy, M. (1997) · Applied Optics · doi:10.1364/ao.36.006548 · Cited by 182
Cense, B., Chen, T. C., Park, B. H., Pierce, M. C., & de Boer, J. F. (2002) · Optics Letters · doi:10.1364/ol.27.001610 · Cited by 182
Hyle Park, B., Pierce, M. C., Cense, B., & de Boer, J. F. (2004) · Optics Letters · doi:10.1364/ol.29.002512 · Cited by 180 · cited 6×
“It should be noted that diattenuation in biological tissue is usually very weak and thus is often assumed negligible for PS-OCT [16,17], although attempts have been made to quantify diattenuation using PS-OCT [15,17,18].”
BackgroundMethodInfluentialPolarization-sensitive optical coherence tomography of invasive basal cell carcinoma
Strasswimmer, J., Pierce, M. C., Park, B. H., Neel, V., & de Boer, J. F. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1644118 · Cited by 167 · cited 1×
“and depolarization characteristics enabled imaging and identification of skin lesions such as basal cell carcinoma (Figure 8a–d) [24,182,183].”
BackgroundJiao, S., Yao, G., & Wang, L. V. (2000) · Applied Optics · doi:10.1364/ao.39.006318 · Cited by 165
Baumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163 · cited 2×
“, it is reduced or even absent in albino patients [25,153].”
BackgroundSelf-citationJiao, S., & Wang, L. V. (2002) · Optics Letters · doi:10.1364/ol.27.000101 · Cited by 163
Human Macula Investigated In Vivo with Polarization-Sensitive Optical Coherence Tomography
Pircher, M., Go¨tzinger, E., Findl, O., Michels, S., Geitzenauer, W., Leydolt, C., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-1589 · Cited by 161 · cited 1×
“PS-OCT images of the human retina exhibit strong depolarization in pigmented structures such as the RPE [150,151].”
BackgroundReal-time multi-functional optical coherence tomography
Park, B. H., Pierce, M. C., Cense, B., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.000782 · Cited by 155 · cited 1×
“By computing this angle between the Stokes vectors at the sample surface and those within the tissue, cumulative phase retardation can be computed at any sample position [66,67].”
BackgroundSchlanitz, F. G., Baumann, B., Kundi, M., Sacu, S., Baratsits, M., Scheschy, U., Shahlaee, A., Mittermüller, T. J., Montuoro, A., Roberts, P., et al. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308422 · Cited by 154 · cited 1×
“In age-related macular degeneration (AMD), PS-OCT was not only used to distinguish drusen characteristics but also to quantify the area and volume of drusen during disease progression (Figure 5f–h) [122,124,156].”
BackgroundSelf-citationJones-matrix imaging of biological tissues with quadruple-channel optical coherence tomography
Jiao, S., & Wang, L. V. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483878 · Cited by 154
Giattina, S. D., Courtney, B. K., Herz, P. R., Harman, M., Shortkroff, S., Stamper, D. L., Liu, B., Fujimoto, J. G., & Brezinski, M. E. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2005.11.036 · Cited by 153
High-speed polarization sensitive optical frequency domain imaging with frequency multiplexing
Oh, W., Yun, S. H., Vakoc, B. J., Shishkov, M. S., Desjardins, A. E., Park, B. H., de Boer, J. F., Tearney, G. J., & Bouma, B. E. (2008) · Optics Express · doi:10.1364/oe.16.001096 · Cited by 149 · cited 1×
“Alternatively, using a Mach–Zehnder type interferometer, only the polarization state in the sample arm can be varied [71,72] from one scan to the next.”
MethodYamanari, M., Makita, S., & Yasuno, Y. (2008) · Optics Express · doi:10.1364/oe.16.005892 · Cited by 146 · cited 1×
“PS-OCT of the anterior eye markedly improves the contrast for birefringent, collagenous tissues such as the cornea, sclera, and tendons as well as for the trabecular meshwork [40,84,94,127].”
BackgroundVilliger, M., Lorenser, D., McLaughlin, R. A., Quirk, B. C., Kirk, R. W., Bouma, B. E., & Sampson, D. D. (2016) · Scientific Reports · doi:10.1038/srep28771 · Cited by 140 · cited 4×
“( –j) Needle-based PS-OCT of breast cance (reproduced with permission from [112], M.”
BackgroundInfluentialImaging of polarization properties of human retina in vivo with phase resolved transversal PS-OCT
Pircher, M., Götzinger, E., Leitgeb, R. A., Sattmann, H., Findl, O., & Hitzenberger, C. K. F. (2004) · Optics Express · doi:10.1364/opex.12.005940 · Cited by 132 · cited 1×
“PS-OCT images of the human retina exhibit strong depolarization in pigmented structures such as the RPE [150,151].”
BackgroundBaumann, B., Choi, W., Potsaid, B. M., Huang, D., Duker, J. S., & Fujimoto, J. G. (2012) · Optics Express · doi:10.1364/oe.20.010229 · Cited by 130
Self-citationVilliger, M., Zhang, E. Z., Nadkarni, S. K., Oh, W., Vakoc, B. J., & Bouma, B. E. (2013) · Optics Express · doi:10.1364/oe.21.016353 · Cited by 130
Ahlers, C., Götzinger, E., Pircher, M., Golbaz, I., Prager, F., Schütze, C., Baumann, B., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3817 · Cited by 129 · cited 1×
“Depolarization has proven a particularly useful contrast for the assessment of the RPE in clinical cases, where it is often hard to distinguish ocular structures in pathological eyes [20,103,154,155].”
BackgroundSelf-citationJu, M. J., Hong, Y.-J., Makita, S., Lim, Y., Kurokawa, K., Duan, L., Miura, M., Tang, S., & Yasuno, Y. (2013) · Optics Express · doi:10.1364/oe.21.019412 · Cited by 117 · cited 1×
“Such combinations may not only improve the contrast for vascular tissue components but also provide additional, complementary insight into disease patterns [30,103,105,106].”
BackgroundGyromagnetic Imaging: Dynamic Optical Contrast Using Gold Nanostars with Magnetic Cores
Wei, Q., Song, H.-M., Leonov, A. P., Hale, J. A., Oh, D., Ong, Q. K., Ritchie, K. P., & Wei, A. (2009) · Journal of the American Chemical Society · doi:10.1021/ja901562j · Cited by 117 · cited 1×
“In order to increase detection sensitivity for single particles, their polarization-sensitive scattering signal in the near infrared can be modulated by an external oscillating magnetic field [231].”
BackgroundBaumann, B., Götzinger, E., Pircher, M., Sattmann, H., Schütze, C., Schlanitz, F. G., Ahlers, C., Schmidt-Erfurth, U. M., & Hitzenberger, C. K. F. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3499420 · Cited by 115 · cited 3×
“(f,g) PS-OCT based layer segmentation in an AMD patient with drusen (adapted with permission from [121], SPIE, 2010).”
BackgroundMethodSelf-citationMakita, S., Hong, Y.-J., Miura, M., & Yasuno, Y. (2014) · Optics Letters · doi:10.1364/ol.39.006783 · Cited by 113 · cited 1×
“have been developed including DOPU with noise floor normalization [21], spectral DOPU [22], the depolarization index independent of the incident polarization state [23], and the differential depolarization index providing a larger dynamic range for depolarization mapping [24].”
MethodWang, H., Black, A. J., Zhu, J., Stigen, T., Al-Qaisi, M. K., Netoff, T. I., Abosch, A., & Akkin, T. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.005 · Cited by 111
Transversal phase resolved polarization sensitive optical coherence tomography
Pircher, M., Goetzinger, E., Leitgeb, R. A., & Hitzenberger, C. K. F. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/013 · Cited by 109 · cited 2×
“Later rapid reference scanning schemes [79,80] and advanced beam scanning approaches such as transverse-scanning PS-OCT [40] sped up the technique to several frames (B-scans) per second.”
BackgroundMethodTodorović, M., Jiao, S., Wang, L. V., & Stoica, G. (2004) · Optics Letters · doi:10.1364/ol.29.002402 · Cited by 93 · cited 2×
“1 is based on a single circular input state and relies on the assumptions that the sample is not diattenuating (which is a valid assumption for most biological tissues [17,56]) and that the axis orientation of the birefringent structure does not change along depth [43,44].”
BackgroundImaging Polarimetry in Age-Related Macular Degeneration
Miura, M., Yamanari, M., Iwasaki, T., Elsner, A. E., Makita, S., Yatagai, T., & Yasuno, Y. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-0501 · Cited by 92
Li, E., Makita, S., Hong, Y.-J., Kasaragod, D. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001290 · Cited by 92 · cited 1×
“For instance, in collagenous tissue such as skin, local birefringence can be used for the depth-resolved assessment of the collagen content [77,78].”
BackgroundThree dimensional polarization sensitive OCT of human skin in vivo
Pircher, M., Goetzinger, E., Leitgeb, R. A., & Hitzenberger, C. K. F. (2004) · Optics Express · doi:10.1364/opex.12.003236 · Cited by 91 · cited 1×
“Using PS-OCT, dermal layers with different scattering and polarization properties can be observed, including stratum corneum, dermis, and epidermis (Figure 7) [50,64,172,173].”
BackgroundSchütze, C., Wedl, M., Baumann, B., Pircher, M., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.02.020 · Cited by 90
Self-citationPolarization-Sensitive Multimodal Imaging for Detecting Breast Cancer
Patel, R. P., Khan, A. A., Quinlan, R., & Yaroslavsky, A. N. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2411 · Cited by 88 · cited 1×
“Several groups also successfully studied PS-OCT for imaging breast cancer [112,186,187].”
BackgroundImaging myocardial fiber orientation using polarization sensitive optical coherence tomography
Fan, C., & Yao, G. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000460 · Cited by 88 · cited 1×
“As such, Jones matrix PS-OCT can not only measure phase retardation but also diattenuation [15], local birefringence [16], and local optic axis orientation [76].”
BackgroundBraaf, B., Vermeer, K. A., de Groot, M., Vienola, K. V., & de Boer, J. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002736 · Cited by 87 · cited 5×
“It should be noted that diattenuation in biological tissue is usually very weak and thus is often assumed negligible for PS-OCT [16,17], although attempts have been made to quantify diattenuation using PS-OCT [15,17,18].”
BackgroundMethodInfluentialLim, Y., Hong, Y.-J., Duan, L., Yamanari, M., & Yasuno, Y. (2012) · Optics Letters · doi:10.1364/ol.37.001958 · Cited by 85 · cited 2×
“In particular the advent of commercial laser technology providing longer imaging ranges led to the development of PS-OCT at ultrahigh imaging speeds of 100,000 axial scans per second [18,54,73,74,98].”
BackgroundMethodNadkarni, S. K., Bouma, B. E., de Boer, J. F., & Tearney, G. J. (2008) · Lasers in Medical Science · doi:10.1007/s10103-007-0535-x · Cited by 85
Serial optical coherence scanner for large-scale brain imaging at microscopic resolution
Wang, H., Zhu, J., & Akkin, T. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.09.063 · Cited by 84
Polarization-sensitive spectral-domain optical coherence tomography using a single line scan camera
Cense, B., Mujat, M., Chen, T. C., Park, B. H., & de Boer, J. F. (2007) · Optics Express · doi:10.1364/oe.15.002421 · Cited by 81
Li, B. H., Leung, A. S. O., Soong, A., Munding, C. E., Lee, H., Thind, A. S., Munce, N. R., Wright, G. A., Rowsell, C. H., Yang, V. X. D., et al. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24295 · Cited by 77 · cited 1×
“To further increase the contrast and image range, PS-OCT has been combined with other technologies such as ultrasound and fluorescence imaging [113,114].”
MethodMichels, S., Pircher, M., Geitzenauer, W., Simader, C., Götzinger, E., Findl, O., Schmidt-Erfurth, U. M., & Hitzenberger, C. K. F. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.130047 · Cited by 75 · cited 1×
“Depolarization has proven a particularly useful contrast for the assessment of the RPE in clinical cases, where it is often hard to distinguish ocular structures in pathological eyes [20,103,154,155].”
BackgroundSouth, F. A., Chaney, E. J., Marjanović, M., Adie, S. G., & Boppart, S. A. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003417 · Cited by 75 · cited 1×
“Several groups also successfully studied PS-OCT for imaging breast cancer [112,186,187].”
BackgroundFortune, B. A., Burgoyne, C. F., Cull, G. A., Reynaud, J. F., & Wang, L. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12219 · Cited by 73 · cited 1×
“PS-OCT based assessment of the RNFL’s birefringent properties might be particularly interesting since it was shown that polarization changes in experimental glaucoma can be observed earlier than RNFL thickness changes [135].”
BackgroundPrimate retina imaging with polarization-sensitive optical coherence tomography
Ducros, M. G., Marsack, J. D., Rylander, H. G., Thomsen, S. L., & Milner, T. E. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.002945 · Cited by 68 · cited 1×
“After initial experiments in the primate retina [140], RNFL birefringence was measured in vivo in the human eye by performing circular scans around the optic nerve head [79,141].”
MethodWang, H., Zhu, J., Reuter, M., Vinke, L. N., Yendiki, A., Boas, D. A., Fischl, B., & Akkin, T. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.032 · Cited by 67 · cited 2×
“Toluidine blue staining for assessing the myelination state; (e–h) En face PS-OCT optic axis orientation maps quantitatively depict in-plane fiber orientations in the medulla (from [229] with permission by Elsevier).”
BackgroundHuang, X.-R., & Knighton, R. W. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463050 · Cited by 67 · cited 1×
“Since the RNFL is damaged in glaucoma—the second leading cause of blindness worldwide [132]—and since RNFL birefringence is connected to layer integrity [133,134], the polarization properties of the RNFL were investigated as potential diagnostic markers for glaucoma.”
BackgroundKiseleva, E. B., Kirillin, M., Feldchtein, F. I., Vitkin, I. A., Sergeeva, E. A., Вадимовна, З. Е., Streltzova, O., Shakhov, B. E., Gubarkova, E. V., & Gladkova, N. D. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001464 · Cited by 67 · cited 2×
“Such settings correspond to regular OCT, however with altered reference polarization for cross-polarization imaging [32,33] or for imaging with variable reference polarization [34].”
BackgroundIn vivo evaluation of human skin anisotropy by polarization-sensitive optical coherence tomography
Sakai, S., Yamanari, M., Lim, Y., Nakagawa, N., & Yasuno, Y. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002623 · Cited by 67
Kemp, N. J., Zaatari, H. N., Park, J., Rylander, H. G., & Milner, T. E. (2005) · Optics Express · doi:10.1364/opex.13.004611 · Cited by 67 · cited 1×
“1 is based on a single circular input state and relies on the assumptions that the sample is not diattenuating (which is a valid assumption for most biological tissues [17,56]) and that the axis orientation of the birefringent structure does not change along depth [43,44].”
BackgroundGo¨tzinger, E., Pircher, M., Dejaco‐Ruhswurm, I., Kaminski, S. L., Skorpik, C., & Hitzenberger, C. K. F. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0727 · Cited by 67 · cited 2×
“Substantial changes in the birefringent appearance of the cornea can be observed in keratoconus as shown in Figure 6a–e, such that PS-OCT was proposed as a diagnostic method for this disease [128,165].”
BackgroundMethodLammer, J., Bolz, M., Baumann, B., Pircher, M., Gerendas, B. S., Schlanitz, F. G., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-13539 · Cited by 66
Self-citationPerformance of Automated Drusen Detection by Polarization-Sensitive Optical Coherence Tomography
Schlanitz, F. G., Baumann, B., Spalek, T., Schütze, C., Ahlers, C., Pircher, M., Götzinger, E., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6846 · Cited by 64 · cited 1×
“In age-related macular degeneration (AMD), PS-OCT was not only used to distinguish drusen characteristics but also to quantify the area and volume of drusen during disease progression (Figure 5f–h) [122,124,156].”
BackgroundSelf-citationUgryumova, N., Jacobs, J. W., Bonesi, M., & Matcher, S. J. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2008.05.005 · Cited by 64 · cited 1×
“PS-OCT using variable incidence angles was further used to investigate the 3D architecture of the collagen fiber network in cartilage [197,198].”
MethodWang, Z., Lee, H., Vermeulen, D., Chen, L., Nielsen, T., Park, S. Y., Ghaemi, A., Swanson, E. A., Doerr, C. R., & Fujimoto, J. G. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002562 · Cited by 60
Lippok, N., Villiger, M., & Bouma, B. E. (2015) · Optics Letters · doi:10.1364/ol.40.003954 · Cited by 60 · cited 1×
“have been developed including DOPU with noise floor normalization [21], spectral DOPU [22], the depolarization index independent of the incident polarization state [23], and the differential depolarization index providing a larger dynamic range for depolarization mapping [24].”
MethodFan, C., & Yao, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.11.110501 · Cited by 60 · cited 1×
“1 is based on a single circular input state and relies on the assumptions that the sample is not diattenuating (which is a valid assumption for most biological tissues [17,56]) and that the axis orientation of the birefringent structure does not change along depth [43,44].”
BackgroundAl-Qaisi, M. K., & Akkin, T. (2008) · Optics Express · doi:10.1364/oe.16.013032 · Cited by 59
Gong, P., Chin, L., Es’haghian, S., Liew, Y. M., Wood, F. M., Sampson, D. D., & McLaughlin, R. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.12.126014 · Cited by 59 · cited 3×
“(f–j) Birefringence and vascular imaging of a hypertrophic scar and adjacent normal skin (adapted with permission from [106], P.”
BackgroundKeratoconus Diagnosis Using Anterior Segment Polarization-Sensitive Optical Coherence Tomography
Fukuda, S., Yamanari, M., Lim, Y., Hoshi, S., Beheregaray, S., Oshika, T., & Yasuno, Y. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10979 · Cited by 59 · cited 1×
“Substantial changes in the birefringent appearance of the cornea can be observed in keratoconus as shown in Figure 6a–e, such that PS-OCT was proposed as a diagnostic method for this disease [128,165].”
MethodSchlanitz, F. G., Sacu, S., Baumann, B., Bolz, M., Platzer, M., Pircher, M., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.05.008 · Cited by 57 · cited 1×
“In age-related macular degeneration (AMD), PS-OCT was not only used to distinguish drusen characteristics but also to quantify the area and volume of drusen during disease progression (Figure 5f–h) [122,124,156].”
BackgroundSelf-citationBaumann, B., Wöehrer, A., Ricken, G., Augustin, M., Mitter, C., Pircher, M., Kovács, G. G., & Hitzenberger, C. K. F. (2017) · Scientific Reports · doi:10.1038/srep43477 · Cited by 55 · cited 4×
“Color map range: 7–41◦ (reproduced with permission from [230], B.”
BackgroundSelf-citationOldenburg, A. L., Chhetri, R. K., Cooper, J. M., Wu, W., Troester, M. A., & Tracy, J. B. (2013) · Optics Letters · doi:10.1364/ol.38.002923 · Cited by 55 · cited 2×
“Based on temporal changes in polarization contrast parameters, a method for differentiating light scatterers such as cells and gold nanorods was developed [233].”
MethodLee, R. C., Kang, H., Darling, C. L., & Fried, D. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002950 · Cited by 54 · cited 1×
“Recently, an automated method for assessing remineralized lesions was developed based on PS-OCT [222].”
MethodChhetri, R. K., Blackmon, R. L., Wu, W., Hill, D. B., Button, B. M., Casbas-Hernández, P., Troester, M. A., Tracy, J. B., & Oldenburg, A. L. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1409321111 · Cited by 54 · cited 4×
“The arrows indicate highly strained areas at the teeth of the wheel; (c) Orientation of the slow optic axis (color-coded and displayed as vector-field scaled by the magnitude of the retardation); (d) Diffusion of gold nanorods (GNRs) in in vitro extracellular matrix models (adapted ith permission from [234], A.”
BackgroundInfluentialImaging the Mucosa of the Human Vocal Fold with Optical Coherence Tomography
Burns, J. A., Zeitels, S. M., Anderson, R. R., Kobler, J. B., Pierce, M. C., & de Boer, J. F. (2005) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940511400903 · Cited by 53 · cited 1×
“In the oropharyngeal tract, PS-OCT was demonstrated for investigating the mucosa of the vocal fold and for detecting lesions in the buccal mucosa based on increased birefringence [174,175].”
BackgroundRoberts, P. K., Sugita, M., Deák, G. G., Baumann, B., Zotter, S., Pircher, M., Sacu, S., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18694 · Cited by 51
Self-citationLo, W. C. Y., Villiger, M., Golberg, A., Broelsch, G. F., Khan, S. I., Lian, C. G., Austen, W. G., Yarmush, M. L., & Bouma, B. E. (2015) · Journal of Investigative Dermatology · doi:10.1038/jid.2015.399 · Cited by 50 · cited 1×
“For instance, in collagenous tissue such as skin, local birefringence can be used for the depth-resolved assessment of the collagen content [77,78].”
BackgroundBaumann, B., Schirmer, J., Rauscher, S., Fialová, S., Glösmann, M., Augustin, M., Pircher, M., Gröger, M., & Hitzenberger, C. K. F. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-17742 · Cited by 49
Self-citationAdie, S. G., Hillman, T. R., & Sampson, D. D. (2007) · Optics Express · doi:10.1364/oe.15.018033 · Cited by 48 · cited 4×
“Moreover, Stokes vector based depolarization imaging can reveal multiple scattering as well as pathological conditions in skin such as cancer [19,24,58], as will be discussed in the next section.”
BackgroundMethodInfluentialTrasischker, W., Zotter, S., Torzicky, T., Baumann, B., Haindl, R., Pircher, M., & Hitzenberger, C. K. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002798 · Cited by 48 · cited 1×
“In particular the advent of commercial laser technology providing longer imaging ranges led to the development of PS-OCT at ultrahigh imaging speeds of 100,000 axial scans per second [18,54,73,74,98].”
BackgroundSelf-citationHong, Y.-J., Miura, M., Ju, M. J., Makita, S., Iwasaki, T., & Yasuno, Y. (2014) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.14-14005 · Cited by 47 · cited 2×
“Depolarization has proven a particularly useful contrast for the assessment of the RPE in clinical cases, where it is often hard to distinguish ocular structures in pathological eyes [20,103,154,155].”
BackgroundSugita, M., Zotter, S., Pircher, M., Makihira, T., Saito, K., Tomatsu, N., Sato, M., Roberts, P. K., Schmidt-Erfurth, U. M., & Hitzenberger, C. K. F. (2013) · Biomedical Optics Express · doi:10.1364/boe.5.000106 · Cited by 47 · cited 3×
“(a–d) PS-OCT of a patient with late-stage A D (adapted with permission from [120], Optical Society of America, 2014).”
BackgroundRitter, M., Zotter, S., Schmidt, W. M., Bittner, R. E., Deák, G. G., Pircher, M., Sacu, S., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11550 · Cited by 47 · cited 1×
“Finally, PS-OCT also proved useful to enhance contrast for imaging pathologic structures in less common retinal diseases such as macular telangiectasia and Stargardt disease [163,164].”
BackgroundMulti-Functional OCT Enables Longitudinal Study of Retinal Changes in a VLDLR Knockout Mouse Model
Augustin, M., Fialová, S., Himmel, T., Glösmann, M., Lengheimer, T., Harper, D. J., Plasenzotti, R., Pircher, M., Hitzenberger, C. K. F., & Baumann, B. (2016) · PLoS ONE · doi:10.1371/journal.pone.0164419 · Cited by 44 · cited 1×
“Such combinations may not only improve the contrast for vascular tissue components but also provide additional, complementary insight into disease patterns [30,103,105,106].”
BackgroundSelf-citationIslam, M. S., Oliveira, M. C., Wang, Y., Park, B. H., Henry, F. P., Randolph, M. A., & de Boer, J. F. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056012 · Cited by 43 · cited 1×
“tissues as well as quantitative birefringence measurements were enabled by the additional polarization contrast [224].”
Baumann, B., Götzinger, E., Pircher, M., & Hitzenberger, C. K. F. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910031 · Cited by 43 · cited 1×
“In the RPE, this depolarization is most pronounced around the fovea [152] and correlates with the pigmentation status, i.”
BackgroundSelf-citationRetinal nerve fiber bundle tracing and analysis in human eye by polarization sensitive OCT
Sugita, M., Pircher, M., Zotter, S., Baumann, B., Roberts, P. K., Makihira, T., Tomatsu, N., Sato, M., Vass, C., & Hitzenberger, C. K. F. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.001030 · Cited by 43 · cited 14×
“(i,j) Birefringence in the retinal nerve fiber layer (RNFL) imaged by PS-OCT (adapted wi h permission from [18], Optical Society f America, 2014).”
BackgroundSelf-citationYamanari, M., Nagase, S., Fukuda, S., Ishii, K., Tanaka, R., Yasui, T., Oshika, T., Miura, M., & Yasuno, Y. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001391 · Cited by 40 · cited 1×
“In the sclera, PS-OCT was used to image necrotizing scleritis [170] and to study birefringence changes related to increased intraocular pressure [148,171].”
MethodDuan, L., Marvdashti, T., Lee, A., Tang, J. Y., & Bowden, A. K. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.003717 · Cited by 38 · cited 2×
“and depolarization characteristics enabled imaging and identification of skin lesions such as basal cell carcinoma (Figure 8a–d) [24,182,183].”
BackgroundDuan, L., Yamanari, M., & Yasuno, Y. (2012) · Optics Express · doi:10.1364/oe.20.003353 · Cited by 38
Liu, B., Harman, M., Giattina, S. D., Stamper, D. L., Demakis, C., Chilek, M., Raby, S., & Brezinski, M. E. (2006) · Applied Optics · doi:10.1364/ao.45.004464 · Cited by 37 · cited 1×
“Such settings correspond to regular OCT, however with altered reference polarization for cross-polarization imaging [32,33] or for imaging with variable reference polarization [34].”
BackgroundRoberts, P. K., Baumann, B., Lammer, J., Gerendas, B. S., Kroisamer, J. S., Buehl, W., Pircher, M., Hitzenberger, C. K. F., Schmidt-Erfurth, U. M., & Sacu, S. (2016) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.15-18494 · Cited by 37
Self-citationOptical tractography of the mouse heart using polarization-sensitive optical coherence tomography
Wang, Y., & Yao, G. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.002540 · Cited by 36 · cited 2×
“Depth-resolved measurements of the birefringent axis orientation have recently gained interest for mapping the orientation of birefringent fibers in PS-OCT based tractography of collagenous tissue [69,70].”
BackgroundMethodKasaragod, D. K., Lu, Z., Jacobs, J. W., & Matcher, S. J. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000378 · Cited by 35 · cited 1×
“PS-OCT using variable incidence angles was further used to investigate the 3D architecture of the collagen fiber network in cartilage [197,198].”
MethodSchütze, C., Bolz, M., Sayegh, R. G., Baumann, B., Pircher, M., Götzinger, E., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-7877 · Cited by 34 · cited 1×
“In late stage non-exudative (dry) AMD, PS-OCT enables the assessment of atrophic areas lacking RPE (Figure 5a–d) [121,157,158].”
BackgroundSelf-citationEnhanced depolarization contrast in polarization-sensitive optical coherence tomography
Ortega-Quijano, N., Marvdashti, T., & Bowden, A. K. (2016) · Optics Letters · doi:10.1364/ol.41.002350 · Cited by 31 · cited 6×
“(a–d) PS-OCT of basal cell carcinoma in human skin (adapted with permission from [24], Optical Society of America, 2016).”
BackgroundMethodInfluentialGo¨tzinger, E., Pircher, M., Baumann, B., Hirn, C., Vass, C., & Hitzenberger, C. K. F. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2081 · Cited by 29
Self-citationLiu, G., Zhang, J., Yu, L., Xie, T., & Chen, Z. (2009) · Applied Optics · doi:10.1364/ao.48.006365 · Cited by 29 · cited 1×
“Real-time display of PS-OCT data was enabled by parallel computing [115].”
MethodSugita, M., Pircher, M., Zotter, S., Baumann, B., Saito, K., Makihira, T., Tomatsu, N., Sato, M., & Hitzenberger, C. K. F. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.1.016011 · Cited by 27
Self-citationSun, C., Wang, Y.-M., Lu, L.-S., Lu, C.-W., Hsu, I., Tsai, M., Yang, C. C. C.-C., Kiang, Y., & Wu, C. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2363358 · Cited by 26 · cited 2×
“In rabbit hearts, the geometry of the perfusion border zone was investigated using PS-OCT and tissue clearing [206], an tissue discrimination was enabled by PS-OCT in rat hearts where decreased birefringence was observed in infarcted hearts [207].”
MethodYoon, Y., Jang, W. H., Xiao, P., Kim, B., Wang, T., Li, Q., Lee, J. Y., Chung, E., & Kim, K. H. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000524 · Cited by 26 · cited 1×
“To further increase the contrast and image range, PS-OCT has been combined with other technologies such as ultrasound and fluorescence imaging [113,114].”
MethodSahu, K., Verma, Y., Sharma, M. R., Rao, K. D., & Gupta, P. K. (2010) · Skin Research and Technology · doi:10.1111/j.1600-0846.2010.00451.x · Cited by 25 · cited 1×
“Additionally, wound healing processes including collagen restoration can be followed with PS-OCT [180,181].”
BackgroundSayegh, R. G., Zotter, S., Roberts, P. K., Kańduła, M. M., Sacu, S., Kreil, D. P., Baumann, B., Pircher, M., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2015) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-15114 · Cited by 25 · cited 1×
“In late stage non-exudative (dry) AMD, PS-OCT enables the assessment of atrophic areas lacking RPE (Figure 5a–d) [121,157,158].”
BackgroundSelf-citationSchütze, C., Ritter, M., Blum, R., Zotter, S., Baumann, B., Pircher, M., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2014) · Retina · doi:10.1097/iae.0000000000000224 · Cited by 20 · cited 1×
“, it is reduced or even absent in albino patients [25,153].”
BackgroundSelf-citationNadkarni, S. K. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.12.121507 · Cited by 19 · cited 2×
“Birefringence of vessel walls is a promising diagnostic parameter for arteriosclerotic vascular disease accessible by PS-OCT [201].”
BackgroundLurie, K. L., Moritz, T. J., & Bowden, A. K. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002273 · Cited by 19
Yang, Y., Rupani, A., Wimpenny, I., Weightman, A. P., & Bagnaninchi, P. O. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.8.081417 · Cited by 15 · cited 2×
“properties of tendons have been studied by PS-OCT [192].”
BackgroundDifferential geometry of normalized Stokes vector trajectories in anisotropic media
Park, J., Kemp, N. J., Zaatari, H. N., Rylander, H. G., & Milner, T. E. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.23.000679 · Cited by 15
Hong, Y.-J., Makita, S., Sugiyama, S., & Yasuno, Y. (2014) · Biomedical Optics Express · doi:10.1364/boe.6.000225 · Cited by 14
Visualizing the complex 3D geometry of the perfusion border zone in isolated rabbit heart
Smith, R., Black, A. J., Velamakanni, S. S., Akkin, T., & Tolkacheva, E. G. (2012) · Applied Optics · doi:10.1364/ao.51.002713 · Cited by 12 · cited 2×
“In rabbit hearts, the geometry of the perfusion border zone was investigated using PS-OCT and tissue clearing [206], an tissue discrimination was enabled by PS-OCT in rat hearts where decreased birefringence was observed in infarcted hearts [207].”
MethodSchütze, C., Ahlers, C., Pircher, M., Baumann, B., Götzinger, E., Prager, F., Matt, G., Sacu, S., Hitzenberger, C. K. F., & Schmidt-Erfurth, U. M. (2011) · Retina · doi:10.1097/iae.0b013e31821edfb0 · Cited by 9 · cited 1×
“Finally, PS-OCT also proved useful to enhance contrast for imaging pathologic structures in less common retinal diseases such as macular telangiectasia and Stargardt disease [163,164].”
BackgroundSelf-citationSpectral degree of polarization uniformity for polarization-sensitive OCT
Baumann, B., Zotter, S., Pircher, M., Götzinger, E., Rauscher, S., Glösmann, M., Lammer, J., Schmidt-Erfurth, U. M., Gröger, M., & Hitzenberger, C. K. F. (2014) · Journal of Modern Optics · doi:10.1080/09500340.2014.945501 · Cited by 9 · cited 18×
“In DOPU images, DOPU values at every spatial coordinate are color-coded.”
MethodSelf-citation
Metadata
- Authors
- Baumann, B.
- Venue
- Applied Sciences
- Publisher
- MDPI AG
- Published
- 2017-05-04
- Volume
- 7
- Issue
- 5
- Pages
- 474
- ISSN
- 2076-3417 (ISSN-L)
- OpenAlex
- W2610854155
- Cited by
- 171
- References
- 138
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.