The DOI matches its Crossref record; 120 of the 120 references it cites were found in a registry or an index.
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Open accessAbstract
Wearable electronics is a rapidly growing field that recently started to introduce successful commercial products into the consumer electronics market. Employment of biopotential signals in wearable systems as either biofeedbacks or control commands are expected to revolutionize many technologies including point of care health monitoring systems, rehabilitation devices, human–computer/machine interfaces (HCI/HMIs), and brain–computer interfaces (BCIs). Since electrodes are regarded as a decisive part of such products, they have been studied for almost a decade now, resulting in the emergence of textile electrodes. This study presents a systematic review of wearable textile electrodes in physiological signal monitoring, with discussions on the manufacturing of conductive textiles, metrics to assess their performance as electrodes, and an investigation of their application in the acquisition of critical biopotential signals for routine monitoring, assessment, and exploitation of cardiac (electrocardiography, ECG), neural (electroencephalography, EEG), muscular (electromyography, EMG), and ocular (electrooculography, EOG) functions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novoselov, K. S., Fal′ko, V. I., Colombo, L., Gellert, P. R., Schwab, M. G., & Kim, K. (2012) · Nature · doi:10.1038/nature11458 · Cited by 9,251
A review on polymer nanofibers by electrospinning and their applications in nanocomposites
Huang, Z.-M., Zhang, Y.-Z., Kotaki, M., & Ramakrishna, S. (2003) · Composites Science and Technology · doi:10.1016/s0266-3538(03)00178-7 · Cited by 7,556
Electrospinning: A fascinating fiber fabrication technique
Bhardwaj, N., & Kundu, S. C. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2010.01.004 · Cited by 5,028
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
(2002) · Cited by 1,481
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Handbook of Physical Vapor Deposition (PVD) Processing
(2010) · Elsevier eBooks · doi:10.1016/c2009-0-18800-1 · Cited by 816
(2006) · doi:10.1007/1-84628-484-8 · Cited by 667
How many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
Mathiassen, S. E., Winkel, J., & Hägg, G. M. (1995) · Journal of Electromyography and Kinesiology · doi:10.1016/1050-6411(94)00014-x · Cited by 516
Seizure prediction – ready for a new era
Kuhlmann, L., Lehnertz, K., Richardson, M. P., Schelter, B., & Zaveri, H. P. (2018) · Nature Reviews Neurology · doi:10.1038/s41582-018-0055-2 · Cited by 450
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Metal-based Inkjet Inks for Printed Electronics
Kamyshny, A. (2011) · The Open Applied Physics Journal · doi:10.2174/1874183501104010019 · Cited by 424
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
Textile Materials for the Design of Wearable Antennas: A Survey
Salvado, R., Loss, C., Gonçalves, R., & Pinho, P. (2012) · Sensors · doi:10.3390/s121115841 · Cited by 403
Wireless sensor network based wearable smart shirt for ubiquitous health and activity monitoring
Lee, Y.-D., & Chung, W.-Y. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.040 · Cited by 382
Dip-coating for fibrous materials: mechanism, methods and applications
Tang, X., & Yan, X. (2017) · Journal of Sol-Gel Science and Technology · doi:10.1007/s10971-016-4197-7 · Cited by 350
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
BIOTEX—Biosensing Textiles for Personalised Healthcare Management
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., et al. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2038484 · Cited by 330
Towards the integration of textile sensors in a wireless monitoring suit
Catrysse, M., Puers, R., Hertleer, C., Van Langenhove, L., van Egmond, H., & Matthys, D. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.10.071 · Cited by 325
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Al-Mulla, M. R., Sepulveda, F., & Colley, M. (2011) · Sensors · doi:10.3390/s110403545 · Cited by 310
Conductive polymers for smart textile applications
Grancarić, A. M., Jerković, I., Koncar, V., Cochrane, C., Kelly, F. M., Soulat, D., & Legrand, X. (2018) · Journal of Industrial Textiles · doi:10.1177/1528083717699368 · Cited by 286
All inkjet-printed graphene-based conductive patterns for wearable e-textile applications
Karim, N., Afroj, S., Malandraki, A., Butterworth, S., Beach, C., Rigout, M., Novoselov, K. S., Casson, A. J., & Yeates, S. G. (2017) · Journal of Materials Chemistry C · doi:10.1039/c7tc03669h · Cited by 282
Okuzaki, H., Harashina, Y., & Yan, H. (2009) · European Polymer Journal · doi:10.1016/j.eurpolymj.2008.10.027 · Cited by 265
Performance Evaluation of Sensing Fabrics for Monitoring Physiological and Biomechanical Variables
Scilingo, E. P., Gemignani, A., Paradiso, R., Taccini, N., Ghelarducci, B., & DeRossi, D. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854506 · Cited by 247
EEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 239
Self-citationA concise review of carbon nanotube's toxicology
Madani, S. Y., Mandel, A., & Seifalian, A. M. (2013) · Nano Reviews · doi:10.3402/nano.v4i0.21521 · Cited by 237
Design and Modeling of a Textile Pressure Sensor for Sitting Posture Classification
Meyer, J., Arnrich, B., Schumm, J., & Troster, G. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2037330 · Cited by 236
Bio-sensing textile based patch with integrated optical detection system for sweat monitoring
Morris, D., Coyle, S., Wu, Y., Lau, K. T., Wallace, G., & Diamond, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.02.032 · Cited by 235
What is the Source of the EEG?
Kirschstein, T., & Köhling, R. (2009) · Clinical EEG and Neuroscience · doi:10.1177/155005940904000305 · Cited by 206
Internet of Things: Remote Patient Monitoring Using Web Services and Cloud Computing
Mohammed, J., Lung, C.-H., Ocneanu, A., Thakral, A., Jones, C., & Adler, A. (2014) · 2014 IEEE International Conference on Internet of Things(iThings), and IEEE Green Computing and Communications (GreenCom) and IEEE Cyber, Physical and Social Computing (CPSCom) · doi:10.1109/ithings.2014.45 · Cited by 206
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, S., Lonjaret, T., Crisp, D., Badier, J.-M., Malliaras, G. G., & Ismailova, E. (2015) · Scientific Reports · doi:10.1038/srep15003 · Cited by 195
Wearable electronics and photonics
Tao, X. (2005) · Woodhead Publishing Limited eBooks · doi:10.1533/9781845690441 · Cited by 193
Characterization of textile electrodes and conductors using standardized measurement setups
Beckmann, L., Neuhaus, C., Medrano, G., Jungbecker, N., Walter, M., Gries, T., & Leonhardt, S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/2/009 · Cited by 192
Differential cytotoxic effects of graphene and graphene oxide on skin keratinocytes
Pelin, M., Fusco, L., León, V., Martín, C., Criado, A., Sosa, S., Vázquez, E., Tubaro, A., & Prato, M. (2017) · Scientific Reports · doi:10.1038/srep40572 · Cited by 187
Reducing Motion Artifacts and Interference in Biopotential Recording
Webster, J. G. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325244 · Cited by 181
Taji, B., Shirmohammadi, S., Groza, V., & Batkin, I. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2013.2289072 · Cited by 180
López, G., Custodio, V, & Moreno, J. I. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2058812 · Cited by 173
MOPET: A context-aware and user-adaptive wearable system for fitness training
Buttussi, F., & Chittaro, L. (2008) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2007.11.004 · Cited by 171
Textile-structured electrodes for electrocardiogram
Xu, P. J., Zhang, H., & Tao, X. M. (2008) · Textile Progress · doi:10.1080/00405160802597479 · Cited by 168
Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors
Yapici, M., & Alkhidir, T. (2017) · Sensors · doi:10.3390/s17040875 · Cited by 166
Self-citationIntegrating wireless ECG monitoring in textiles
Coosemans, J., Hermans, B., & Puers, R. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.10.052 · Cited by 165
Imperceptible electrooculography graphene sensor system for human–robot interface
Ameri, S. K., Kim, M., Kuang, I. A., Perera, W. K., Alshiekh, M., Jeong, H., Topcu, U., Akinwande, D., & Lu, N. (2018) · npj 2D Materials and Applications · doi:10.1038/s41699-018-0064-4 · Cited by 162
Performance Evaluation of Textile-Based Electrodes and Motion Sensors for Smart Clothing
Cho, G., Jeong, K., Paik, M. J., Kwun, Y., & Sung, M. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2167508 · Cited by 158
Ding, Y., Xu, W., Wang, W., Fong, H., & Zhu, Z. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b06726 · Cited by 154
PEDOT:PSS “Wires” Printed on Textile for Wearable Electronics
Guo, Y., Otley, M. T., Li, M., Zhang, X., Sinha, S., Treich, G. M., & Sotzing, G. A. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b08036 · Cited by 149
Kim, J., & Cho, G. (2002) · Textile Research Journal · doi:10.1177/004051750207201209 · Cited by 148
Wu, W., Pirbhulal, S., Sangaiah, A. K., Mukhopadhyay, S. C., & Li, G. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2018.04.024 · Cited by 146
Textile Electrodes for EEG Recording — A Pilot Study
Löfhede, J., Seoane, F., & Thordstein, M. (2012) · Sensors · doi:10.3390/s121216907 · Cited by 145
Graphene-based fabrics and their applications: a review
Molina, J. (2016) · RSC Advances · doi:10.1039/c6ra12365a · Cited by 145
Allison, L. K., Hoxie, S., & Andrew, T. L. (2017) · Chemical Communications · doi:10.1039/c7cc02592k · Cited by 143
Ankhili, A., Tao, X., Cochrane, C., et al. (2018) · Materials · doi:10.3390/ma11020256 · Cited by 137
Guy, V., Soriani, M., Bruno, M., Papadopoulo, T., Desnuelle, C., & Clerc, M. (2017) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2017.09.004 · Cited by 136
Embroidered Electrode with Silver/Titanium Coating for Long-Term ECG Monitoring
Weder, M., Hegemann, D., Amberg, M., et al. (2015) · Sensors · doi:10.3390/s150101750 · Cited by 130
Smart Jacket Design for Neonatal Monitoring with Wearable Sensors
Bouwstra, S., Chen, W., Feijs, L., & Oetomo, S. B. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.40 · Cited by 129
Simplified Structural Textile Respiration Sensor Based on Capacitive Pressure Sensing Method
Min, S. D., Yun, Y. H., & Shin, H. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2327991 · Cited by 128
Textile‐Based Flexible Electroluminescent Devices
Hu, B., Li, D., Ala, O., Manandhar, P., Fan, Q., Kasilingam, D. P., & Calvert, P. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201001110 · Cited by 127
Paul, G., Torah, R. N., Beeby, S., & Tudor, J. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.11.026 · Cited by 127
Two‐Layered and Stretchable e‐Textile Patches for Wearable Healthcare Electronics
La, T., Qiu, S., Scott, D. K., Bakhtiari, R., Kuziek, J. W. P., Mathewson, K. E., Rieger, J., & Chung, H. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201801033 · Cited by 126
Puurtinen, M. M., Komulainen, S. M., Kauppinen, P., Malmivuo, J. A., & Hyttinen, J. (2006) · doi:10.1109/iembs.2006.260155 · Cited by 122
Effect of pressure and padding on motion artifact of textile electrodes
Cömert, A., Honkala, M., & Hyttinen, J. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-26 · Cited by 115
Fully Printed Electrodes on Stretchable Textiles for Long‐Term Electrophysiology
Bihar, E., Roberts, T., Ismailova, E., Saadaoui, M., Işık, M., Sanchez‐Sanchez, A., Mecerreyes, D., Hervé, T., Graaf, J. B. D., & Malliaras, G. G. (2017) · Advanced Materials Technologies · doi:10.1002/admt.201600251 · Cited by 114
Challenges and Future Perspectives on Electroencephalogram-Based Biometrics in Person Recognition
Chan, H.-L., Kuo, P., Cheng, C., & Chen, Y. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00066 · Cited by 111
Surface electromyography: Why, when and how to use it
Garcia, M. A. C., & Vieira, T. (2011) · PORTO@Iris · Cited by 109
Electrical Conductive Textiles Obtained by Screen Printing
Kazanı, İ., Hertleer, C., Mey, G. D., Schwarz, A., Guxho, G., & Langenhove, L. V. (2012) · Ghent University Academic Bibliography (Ghent University) · Cited by 107
A Novel Wearable Forehead EOG Measurement System for Human Computer Interfaces
Heo, J., Yoon, H., & Park, K. (2017) · Sensors · doi:10.3390/s17071485 · Cited by 106
Stitchable organic photovoltaic cells with textile electrodes
Lee, S., Lee, Y., Park, J., & Choi, D. (2014) · Nano Energy · doi:10.1016/j.nanoen.2014.06.017 · Cited by 100
Textile Electrodes in ECG Measurement
Pola, T., & Vanhala, J. J. (2007) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2007.4496917 · Cited by 100
Fabric-Based Active Electrode Design and Fabrication for Health Monitoring Clothing
Merritt, C. R., Nagle, H. T., & Grant, E. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2012408 · Cited by 99
It's in your eyes: towards context-awareness and mobile HCI using wearable EOG goggles
Bulling, A., Roggen, D., & Tröster, G. (2008) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/1409635.1409647 · Cited by 95
A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking
An, X., & Stylios, G. K. (2018) · Materials · doi:10.3390/ma11101887 · Cited by 94
A wearable mobihealth care system supporting real-time diagnosis and alarm
Zheng, J., Zhang, Z., Wu, T. H., & Zhang, Y. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0221-y · Cited by 93
Development of an EOG-Based Automatic Sleep-Monitoring Eye Mask
Liang, S., Kuo, C., Lee, Y., Lin, W., Liu, Y., Chen, P., Cherng, F., & Shaw, F. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2433652 · Cited by 89
Wearable EEG: what is it, why is it needed and what does it entail?
Casson, A. J., Smith, S. J. M., Duncan, J. S., & Rodriguez–Villegas, E. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650549 · Cited by 88
Knit Band Sensor for Myoelectric Control of Surface EMG-Based Prosthetic Hand
Lee, S., Kim, M.-O., Kang, T., Park, J., & Choi, Y. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2865623 · Cited by 79
Sensory baby vest for the monitoring of infants
Linti, C., Horter, H., Osterreicher, P., & Planck, H. (2006) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2006.49 · Cited by 75
Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored
Ishijima, M. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510978 · Cited by 72
Diet eyeglasses: Recognising food chewing using EMG and smart eyeglasses
Zhang, R., Bernhart, S., & Amft, O. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516224 · Cited by 71
Linz, T., Kallmayer, C., Aschenbrenner, R., & Reichl, H. (2006) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2006.26 · Cited by 70
Clinical application of an active electrode using an operational amplifier
Nishimura, S., Tomita, Y., & Horiuchi, T. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.161342 · Cited by 69
A novel EDA glove based on textile-integrated electrodes for affective computing
Lanatà, A., Valenza, G., & Scilingo, E. P. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0921-9 · Cited by 68
Chemically Driven Printed Textile Sensors Based on Graphene and Carbon Nanotubes
Skrzetuska, E., Puchalski, M., & Krucińska, I. (2014) · Sensors · doi:10.3390/s140916816 · Cited by 65
Electrooculography by Wearable Graphene Textiles
Golparvar, A. J., & Yapici, M. K. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2868879 · Cited by 65
Self-citationEMG, Heart Rate, and Accelerometer as Estimators of Energy Expenditure in Locomotion
Tikkanen, O., Kärkkäinen, S., Haakana, P., Kallinen, M., Pullinen, T., & Finni, T. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000298 · Cited by 63
Surface Electromyography in Sports and Exercise
Türker, H., & Sze, H. (2013) · InTech eBooks · doi:10.5772/56167 · Cited by 60
Development of a cooling fabric from conducting polymer coated fibres: Proof of concept
Hu, E. J., Kaynak, A., & Li, Y. (2005) · Synthetic Metals · doi:10.1016/j.synthmet.2005.01.018 · Cited by 60
Cömert, A., & Hyttinen, J. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0044-2 · Cited by 59
High-density EMG E-Textile systems for the control of active prostheses
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627455 · Cited by 57
Embroidered Electromyography: A Systematic Design Guide
Shafti, A., Manero, R. B. R., Borg, A. M., Althoefer, K. A., & Howard, M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2633506 · Cited by 56
Fabrication of conductive fabric as textile electrode for ECG monitoring
Zhou, Y., Ding, X. B., Zhang, J., Duan, Y., Hu, J., & Yang, X. (2014) · Fibers and Polymers · doi:10.1007/s12221-014-2260-y · Cited by 51
Qin, H., Li, J., He, B., Sun, J., Li, L., & Qian, L. (2018) · Materials · doi:10.3390/ma11030370 · Cited by 51
Preliminary study of dry knitted fabric electrodes for physiological monitoring
Mestrovic, M. A., Helmer, R. J. N., Kyratzis, L., et al. (2007) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2007.4496911 · Cited by 50
Integration of a Bluetooth Based ECG System into Clothing
Ottenbacher, J., Romer, S., Kunze, C., et al. (2004) · International Symposium on Wearable Computers · doi:10.1109/iswc.2004.26 · Cited by 49
Simultaneous comparison of 1 gel with 4 dry electrode types for electrocardiography
Meziane, N., Yang, S., Shokoueinejad, M., Webster, J. G., Attari, M., & Eren, H. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/513 · Cited by 48
Smartphones Get Emotional: Mind Reading Images and Reconstructing the Neural Sources
Petersen, M. K., Stahlhut, C., Stopczynski, A., Larsen, J. E., & Hansen, L. K. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-24571-8_72 · Cited by 43
Rienzo, M. D., Vaini, E., & Lombardi, P. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.02.034 · Cited by 41
Wearable ECG Monitoring System Using Conductive Fabrics and Active Electrodes
Lee, S. H., Jung, S. M., Lee, C. K., Jeong, K., Cho, G., & Yoo, S. K. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02580-8_85 · Cited by 37
Trindade, I. G., Martins, F., & Baptista, P. (2015) · Synthetic Metals · doi:10.1016/j.synthmet.2015.09.024 · Cited by 37
Matiko, J. W., Wei, Y., Torah, R. N., Grabham, N. J., Paul, G., Beeby, S., & Tudor, J. (2015) · Smart Materials and Structures · doi:10.1088/0964-1726/24/12/125028 · Cited by 36
Ventilatory threshold during incremental running can be estimated using EMG shorts
Tikkanen, O., Hu, M., Vilavuo, T., Tolvanen, P., Cheng, S., & Finni, T. J. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/4/603 · Cited by 35
Darling, C. E., Dovancescu, S., Saczynski, J. S., Riistama, J. M., Kuniyoshi, F. H. S., Rock, J., Meyer, T. E., & McManus, D. D. (2017) · JMIR Cardio · doi:10.2196/cardio.6057 · Cited by 35
Conductive nanofibres and nanocoatings for smart textiles
Shang, S., & Zeng, W. (2013) · Elsevier eBooks · doi:10.1533/9780857093530.1.92 · Cited by 34
A soft robotic exo-sheath using fabric EMG sensing for hand rehabilitation and assistance
Guo, J., Yu, S., Li, Y., Huang, T.-H., Wang, J., Lynn, B., Fidock, J., Shen, C., Edwards, D. J., & Su, H. (2018) · IEEE International Conference on Soft Robotics (RoboSoft) · doi:10.1109/robosoft.2018.8405375 · Cited by 33
Characterization of dry biopotential electrodes
Xie, L., Yang, G., Xu, L., Seoane, F., Chen, Q., & Zheng, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609791 · Cited by 32
Wearable EMG Shirt for Upper Limb Training
Pino, E. J., Arias, Y., & Aqueveque, P. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513107 · Cited by 32
GREENAWAY, A. H. (1991) · Measurement Science and Technology · doi:10.1088/0957-0233/2/1/001 · Cited by 31
Single-Wall Carbon Nanotube-Coated Cotton Yarn for Electrocardiography Transmission
Zhao, Y., Cao, Y., Liu, J., Zhan, Z., Li, X., & Li, W. J. (2018) · Micromachines · doi:10.3390/mi9030132 · Cited by 31
Performance of electromyography recorded using textile electrodes in classifying arm movements
Li, G., Geng, Y., Tao, D., & Zhou, P. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091053 · Cited by 29
Wearable Graphene Nanotextile Embedded Smart Armband for Cardiac Monitoring
Acar, G., Öztürk, Ö., & Yapici, M. K. (2018) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2018.8589800 · Cited by 27
Self-citationWireless fabric patch sensors for wearable healthcare
Yoo, H., Yoo, J., & Yan, L. (2010) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2010.5626295 · Cited by 26
Exploring Possibilities of ECG Electrodes for Bio-monitoring Smartwear with Cu Sputtered Fabrics
Jang, S., Cho, J., Jeong, K., et al. (2007) · Springer eBooks · doi:10.1007/978-3-540-73107-8_124 · Cited by 25
MWCNT/Cotton-based flexible electrode for electrocardiography
Lam, C. L., Rajdi, N. N. Z. M., & Wicaksono, D. H. B. (2013) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2013.6688179 · Cited by 21
Textile-structured human body surface biopotential signal acquisition electrode
Zhang, H., Li, W., Tao, X., Xu, P., & Liu, H. (2011) · International Congress on Image and Signal Processing (CISP) · doi:10.1109/cisp.2011.6100739 · Cited by 19
Niijima, A., Isezaki, T., Aoki, R., Watanabe, T., & Yamada, T. (2017) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3123021.3123068 · Cited by 19
Fleury, A., Alizadeh, M., Stefan, G., & Chau, T. T. (2017) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268137 · Cited by 17
Farina, D., Lorrain, T., Negro, F., & Jiang, N. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · Cited by 16
Mesárošová, A., Hernández, M. F., Mésároš, P., & Behún, M. (2017) · International Conference on Emerging eLearning Technologies and Applications (ICETA) · doi:10.1109/iceta.2017.8102505 · Cited by 8
Envelope filter sequence to delete blinks and overshoots
Merino-Monge, M., Gómez, I., & Molina-Cantero, A. J. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0046-0 · Cited by 7
Cited by
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Reviews of wearable healthcare systems: Materials, devices and system integration
Lou, Z., Wang, L., Jiang, K., Wei, Z., & Shen, G. (2020) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2019.100523 · Cited by 385
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Fritea, L., Banica, F., Costea, T., Moldovan, L., Dobjanschi, L., Muresan, M., & Cavalu, S. (2021) · Materials · doi:10.3390/ma14216319 · Cited by 311
Mirbakht, S. S., Golparvar, A., Umar, M., Kuzubasoglu, B. A., Irani, F. S., & Yapici, M. K. (2025) · Advanced Science · doi:10.1002/advs.202405988 · Cited by 34
Self-citation
Metadata
- Authors
- Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K.
- Venue
- Electronics
- Publisher
- MDPI AG
- Published
- 2019-04-29
- Volume
- 8
- Issue
- 5
- Pages
- 479
- ISSN
- 2079-9292 (ISSN-L)
- OpenAlex
- W2942015343
- Cited by
- 315
- References
- 120
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.