The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Recent Progress of Miniature MEMS Pressure Sensors
Open accessAbstract
Miniature Microelectromechanical Systems (MEMS) pressure sensors possess various merits, such as low power consumption, being lightweight, having a small volume, accurate measurement in a space-limited region, low cost, little influence on the objects being detected. Accurate blood pressure has been frequently required for medical diagnosis. Miniature pressure sensors could directly measure the blood pressure and fluctuation in blood vessels with an inner diameter from 200 to 1000 μm. Glaucoma is a group of eye diseases usually resulting from abnormal intraocular pressure. The implantable pressure sensor for real-time inspection would keep the disease from worsening; meanwhile, these small devices could alleviate the discomfort of patients. In addition to medical applications, miniature pressure sensors have also been used in the aerospace, industrial, and consumer electronics fields. To clearly illustrate the “miniature size”, this paper focuses on miniature pressure sensors with an overall size of less than 2 mm × 2 mm or a pressure sensitive diaphragm area of less than 1 mm × 1 mm. In this paper, firstly, the working principles of several types of pressure sensors are briefly introduced. Secondly, the miniaturization with the development of the semiconductor processing technology is discussed. Thirdly, the sizes, performances, manufacturing processes, structures, and materials of small pressure sensors used in the different fields are explained in detail, especially in the medical field. Fourthly, problems encountered in the miniaturization of miniature pressure sensors are analyzed and possible solutions proposed. Finally, the probable development directions of miniature pressure sensors in the future are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Timoshenko, S. P., & Woinowsky-Krieger, S. (1959) · UCLA Biblioteca de Ingenieria Civil · Cited by 12,112
Ultrahigh electron mobility in suspended graphene
Bolotin, K. I., Sikes, K. J., Jiang, Z., Klima, M., Fudenberg, G., Hone, J., Kim, P., & Stormer, H. L. (2008) · Solid State Communications · doi:10.1016/j.ssc.2008.02.024 · Cited by 8,057
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Giant Intrinsic Carrier Mobilities in Graphene and Its Bilayer
Morozov, S. V., Novoselov, K. S., Katsnelson, M. I., Schedin, F., Elias, D. C., Jaszczak, J. A., & Geim, A. K. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.016602 · Cited by 3,460
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
Carbon nanotubes: properties and application
Popov, V (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2003.10.001 · Cited by 2,181
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Piezoresistance Effect in Germanium and Silicon
Smith, C. S. (1954) · Physical Review · doi:10.1103/physrev.94.42 · Cited by 2,036
Biodegradable luminescent porous silicon nanoparticles for in vivo applications
Park, J.-H., Gu, L., von Maltzahn, G., Ruoslahti, E., Bhatia, S. N., & Sailor, M. J. (2009) · Nature Materials · doi:10.1038/nmat2398 · Cited by 1,897
Loh, K. P., Bao, Q., Ang, P. K., & Yang, J. (2010) · Journal of Materials Chemistry · doi:10.1039/b920539j · Cited by 1,450
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
“Green” electronics: biodegradable and biocompatible materials and devices for sustainable future
Irimia-Vladu, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60235d · Cited by 1,044
Bioresorbable silicon electronic sensors for the brain
Kang, S.-K., Murphy, R. K. J., Hwang, S.-W., Lee, S. M., Harburg, D. V., Krueger, N. A., Shin, J., Gamble, P., Cheng, H., Yu, S., et al. (2016) · Nature · doi:10.1038/nature16492 · Cited by 998
High-Strength Chemical-Vapor–Deposited Graphene and Grain Boundaries
Lee, G.-H., Cooper, R. C., An, S. J., Lee, S., van der Zande, A., Petrone, N., Hammerberg, A. G., Lee, C., Crawford, B., Oliver, W., et al. (2013) · Science · doi:10.1126/science.1235126 · Cited by 889
Anisotropic etching of silicon
Bean, K. E. (1978) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1978.19250 · Cited by 803
Laterally Driven Polysilicon Resonant Microstructures
Tang, W. C., Nguyen, T.-C. H., & Howe, R. T. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87098-2 · Cited by 743
Micromachined pressure sensors: review and recent developments
Eaton, W. P., & Smith, J. H. (1997) · Smart Materials and Structures · doi:10.1088/0964-1726/6/5/004 · Cited by 593
Wearable Flexible Sensors: A Review
Nag, A., Mukhopadhyay, S. C., & Kosel, J. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2705700 · Cited by 526
Organic Thin‐Film Transistors Fabricated on Resorbable Biomaterial Substrates
Bettinger, C. J., & Bao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200902322 · Cited by 423
Piezoelectric energy harvesting: State-of-the-art and challenges
Toprak, A., & Tigli, O. (2014) · Applied Physics Reviews · doi:10.1063/1.4896166 · Cited by 417
Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods—A Review
Raboel, P. H., Bartek, J., Andresen, M., Bellander, B. M., & Romner, B. (2012) · Critical Care Research and Practice · doi:10.1155/2012/950393 · Cited by 416
Electromechanical Piezoresistive Sensing in Suspended Graphene Membranes
Smith, A. D., Niklaus, F., Paussa, A., Vaziri, S., Fischer, A. C., Sterner, M., Forsberg, F., Delin, A., Esseni, D., Palestri, P., et al. (2013) · Nano Letters · doi:10.1021/nl401352k · Cited by 413
An overview of lead-free piezoelectric materials and devices
Wei, H., Wang, H., Xia, Y., Cui, D., Shi, Y., Dong, M., Liu, C., Ding, T., Zhang, J., Ma, Y., et al. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc04515a · Cited by 393
Softened Elastic Response and Unzipping in Chemical Vapor Deposition Graphene Membranes
Ruiz-Vargas, C. S., Zhuang, H. L., Huang, P. Y., van der Zande, A. M., Garg, S., McEuen, P. L., Muller, D. A., Hennig, R. G., & Park, J. (2011) · Nano Letters · doi:10.1021/nl200429f · Cited by 369
Emerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Graphene based piezoresistive pressure sensor
Zhu, S.-E., Krishna Ghatkesar, M., Zhang, C., & Janssen, G. C. A. M. (2013) · Applied Physics Letters · doi:10.1063/1.4802799 · Cited by 335
Pressure sensitivity in anisotropically etched thin-diaphragm pressure sensors
Clark, S. K., & Wise, K. D. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19792 · Cited by 301
Microplasmas, an emerging field of low-temperature plasma science and technology
Foest, R., Schmidt, M., & Becker, K. (2006) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2005.11.010 · Cited by 286
A Short History of Blood Pressure Measurement
Booth, J. (1977) · Proceedings of the Royal Society of Medicine · doi:10.1177/003591577707001112 · Cited by 268
In vitro and in vivo evaluation of SU-8 biocompatibility
Nemani, K. V., Moodie, K. L., Brennick, J. B., Su, A., & Gimi, B. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.07.001 · Cited by 262
A Multifunctional Capacitive Sensor for Stretchable Electronic Skins
Cotton, D. P. J., Graz, I. M., & Lacour, S. P. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030709 · Cited by 262
Robbins, H., & Schwartz, B. (1959) · Journal of The Electrochemical Society · doi:10.1149/1.2427397 · Cited by 253
Kumar, S. S., & Pant, B. D. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2215-7 · Cited by 252
Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors
Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2004945 · Cited by 251
Modelling of microdischarge devices: plasma and gas dynamics
Kushner, M. J. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/11/001 · Cited by 243
Graphene-based gas sensor: metal decoration effect and application to a flexible device
Cho, B., Yoon, J., Hahm, M. G., Kim, D.-H., Kim, A. R., Kahng, Y. H., Park, S.-W., Lee, Y.-J., Park, S.-G., Kwon, J.-D., et al. (2014) · J. Mater. Chem. C · doi:10.1039/c4tc00510d · Cited by 237
Vacuum packaging for microsensors by glass-silicon anodic bonding
Henmi, H., Shoji, S., Shoji, Y., Yoshimi, K., & Esashi, M. (1994) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(94)80003-0 · Cited by 230
High-Temperature Single-Crystal 3C-SiC Capacitive Pressure Sensor
Young, D. J., Du, J., Zorman, C. A., & Ko, W. H. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.830301 · Cited by 227
Acoustic wave based MEMS devices for biosensing applications
Voiculescu, I., & Nordin, A. N. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.12.041 · Cited by 215
The design, fabrication, and applications of flexible biosensing devices
Xu, M., Obodo, D., & Yadavalli, V. K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.019 · Cited by 208
Graphene Squeeze-Film Pressure Sensors
Dolleman, R. J., Davidovikj, D., Cartamil-Bueno, S. J., et al. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b04251 · Cited by 204
Robbins, H., & Schwartz, B. (1960) · Journal of The Electrochemical Society · doi:10.1149/1.2427617 · Cited by 199
A monolithic capacitive pressure sensor with pulse-period output
Sander, C. S., Knutti, J. W., & Meindl, J. D. (1980) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1980.19958 · Cited by 190
A SiC MEMS Resonant Strain Sensor for Harsh Environment Applications
Azevedo, R. G., Jones, D. G., Jog, A. V., Jamshidi, B., Myers, D. R., Chen, L., Fu, X.-A., Mehregany, M., Wijesundara, M. B. J., & Pisano, A. P. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.891997 · Cited by 181
Effective quality factor tuning mechanisms in micromechanical resonators
Miller, J. M. L., Ansari, A., Heinz, D. B., Chen, Y., Flader, I. B., Shin, D. D., Villanueva, L. G., & Kenny, T. W. (2018) · Applied Physics Reviews · doi:10.1063/1.5027850 · Cited by 165
Akiyama, M., Morofuji, Y., Kamohara, T., Nishikubo, K., Tsubai, M., Fukuda, O., & Ueno, N. (2006) · Journal of Applied Physics · doi:10.1063/1.2401312 · Cited by 161
Energy Harvesting Technologies for Tire Pressure Monitoring Systems
Bowen, C. R., & Arafa, M. H. (2015) · Advanced Energy Materials · doi:10.1002/aenm.201401787 · Cited by 161
Piezoresistive pressure sensors based on polycrystalline silicon
Mosser, V., Suski, J., Goss, J., & Obermeier, E. (1991) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(91)85020-o · Cited by 158
Smith, A. D., Niklaus, F., Paussa, A., Schröder, S., Fischer, A. C., Sterner, M., Wagner, S., Vaziri, S., Forsberg, F., Esseni, D., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b02533 · Cited by 156
Power, M., Thompson, A. J., Anastasova, S., & Yang, G. (2018) · Small · doi:10.1002/smll.201703964 · Cited by 152
Giant Piezoresistance Effects in Silicon Nanowires and Microwires
MILNE, J. S., Rowe, A. C. H., Arscott, S., & Renner, C. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.226802 · Cited by 149
Silver nanowires coated on cotton for flexible pressure sensors
Wei, Y., Chen, S., Lin, Y. Q., Xue, Y., & Liu, L. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc03419a · Cited by 148
Plutnar, J., Pumera, M., & Sofer, Z. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc00463c · Cited by 147
Fracture strength of micro- and nano-scale silicon components
DelRio, F. W., Cook, R. F., & Boyce, B. L. (2015) · Applied Physics Reviews · doi:10.1063/1.4919540 · Cited by 144
A Miniature-Implantable RF-Wireless Active Glaucoma Intraocular Pressure Monitor
Chow, E. Y., Chlebowski, A. L., & Irazoqui, P. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081364 · Cited by 141
A review on nanomechanical resonators and their applications in sensors and molecular transportation
Arash, B., Jiang, J.-W., & Rabczuk, T. (2015) · Applied Physics Reviews · doi:10.1063/1.4916728 · Cited by 130
Organic semiconductors for biological sensing
Borges‐González, J., Kousseff, C. J., & Nielsen, C. B. O. (2019) · Journal of Materials Chemistry C · doi:10.1039/c8tc05900d · Cited by 121
Noninvasive and Nonocclusive Blood Pressure Estimation Via a Chest Sensor
Solà, J., Proença, M., Ferrario, D., Porchet, J.-A., Falhi, A., Grossenbacher, O., Allemann, Y., Rimoldi, S. F., & Sartori, C. S. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2272699 · Cited by 120
A novel capacitive pressure sensor based on sandwich structures
Zhou, M.-X., Huang, Q., Qin, M., & Zhou, W. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859100 · Cited by 115
Long term, implantable blood pressure monitoring systems
Potkay, J. A. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9146-3 · Cited by 113
Development of a bioinspired MEMS based capacitive tactile sensor for a robotic finger
Muhammad, H. B., Oddo, C. M., Beccai, L., Recchiuto, C. T., Anthony, C., Adams, M. J., Carrozza, M. C., Hukins, D. W. L., & Ward, M. C. L. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.10.025 · Cited by 107
Ha, D., de Vries, W. N., John, S. W. M., Irazoqui, P. P., & Chappell, W. J. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9598-3 · Cited by 106
Monolithic silicon‐micromachined free‐space optical interferometers onchip
Sabry, Y. M., Khalil, D. A. M., & Bourouina, T. (2014) · Laser & Photonics Review · doi:10.1002/lpor.201400069 · Cited by 102
SWNT growth by CVD on Ferritin-based iron catalyst nanoparticles towards CNT sensors
Durrer, L., Helbling, T., Zenger, C., Jungen, A., Stampfer, C., & Hierold, C. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.11.007 · Cited by 100
A microscale optical implant for continuous in vivo monitoring of intraocular pressure
Lee, J. O., Park, H., Du, J., Balakrishna, A., Chen, O., Sretavan, D. W., & Choo, H. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.57 · Cited by 89
The first surface micromachined pressure sensor for cardiovascular pressure measurements
Kälvesten, E., Smith, L., Tenerz, L., & Stemme, G. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1998.659821 · Cited by 88
AC electrokinetics of conducting microparticles: A review
Ramos, A., García‐Sánchez, P., & Morgan, H. (2016) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2016.06.018 · Cited by 88
A review of MBE grown 0D, 1D and 2D quantum structures in a nanowire
de la Mata, M., Zhou, X., Furtmayr, F., Teubert, J., Gradečak, S., Eickhoff, M., Morral, A. F. I., & Arbiol, J. (2013) · Journal of Materials Chemistry C · doi:10.1039/c3tc30556b · Cited by 85
Lou, L., Zhang, S., Park, W., Tsai, J. M. L., Kwong, D., & Lee, C. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/5/055012 · Cited by 79
Mechanical behaviors of nanowires
Chen, Y., An, X., & Liao, X. (2017) · Applied Physics Reviews · doi:10.1063/1.4989649 · Cited by 78
Process technology for the modular integration of CMOS and polysilicon microstructures
Bustillo, J. M., Fedder, G. K., Nguyen, C. T. ‐., et al. (1994) · Microsystem Technologies · doi:10.1007/bf01367758 · Cited by 77
Cai, F., Yi, C., Liu, S., Wang, Y., Liu, L., Liu, X., Xu, X., & Wang, L. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.062 · Cited by 76
Low power integrated pressure sensor system for medical applications
Hierold, C., Clasbrummel, B., Behrend, D., Scheiter, T., Steger, M., Oppermann, K.-G., Kapels, H., Landgraf, E., Wenzel, D., & Etzrodt, D. (1999) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00255-6 · Cited by 76
Synthesis of graphene and related two-dimensional materials for bioelectronics devices
Zhang, T., Liu, J., Wang, C., Leng, X., Xiao, Y., & Fu, L. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.072 · Cited by 70
Capacitive pressure sensing with suspended graphene–polymer heterostructure membranes
Berger, C., Phillips, R., Centeno, A., Zurutuza, A., & Vijayaraghavan, A. (2017) · Nanoscale · doi:10.1039/c7nr04621a · Cited by 69
Wu, N., Tian, Y., Zou, X., Zhai, Y., Barringhaus, K. G., & Wang, X. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.02.002 · Cited by 58
Self-citationHighly sensitive pressure sensors based on conducting polymer-coated paper
Zang, X., Jiang, Y., Wang, X., Wang, X., Ji, J., & Xue, M. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.06.132 · Cited by 52
Self-citationSurface micromachined micro-diaphragm pressure sensors
Sugiyama, S., Shimaoka, K., & Tabata, O. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148834 · Cited by 51
An Optical Fibre Depth (Pressure) Sensor for Remote Operated Vehicles in Underwater Applications
Duraibabu, D. B., Poeggel, S., Omerdić, E., Capocci, R., Lewis, E., Newe, T., Leen, G., Toal, D., & Dooly, G. (2017) · Sensors · doi:10.3390/s17020406 · Cited by 51
Li, C., Gao, X., Guo, T., Xiao, J., Fan, S., & Jin, W. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/8/085101 · Cited by 48
A New Image Blood Pressure Sensor Based on PPG, RRT, BPTT, and Harmonic Balancing
Huang, S., Hung, P.-H., Hong, C.-H., & Wang, H. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2329676 · Cited by 42
Full integration of a pressure-sensor system into a standard BiCMOS process
Scheiter, T., Kapels, H., Oppermann, K.-G., et al. (1998) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00029-6 · Cited by 41
A Flexible e-skin based on micro-structured PZT thin films prepared via a low-temperature PLD method
Zhang, S., Zhang, L., Wang, L., Wang, F., & Pan, G. (2019) · Journal of Materials Chemistry C · doi:10.1039/c8tc06350h · Cited by 41
A thin-film pressure transducer for implantable and intravascular blood pressure sensing
Starr, P., Bartels, K. A., Agrawal, C. M., & Bailey, S. R. (2016) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2016.06.035 · Cited by 34
Biocompatibility of a physiological pressure sensor
Yang, C., Zhao, C., Wold, L. E., & Kaufman, K. R. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00131-3 · Cited by 33
Kwon, O. K., Lee, J. H., Kim, K.-S., & Kang, J. W. (2012) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2012.10.010 · Cited by 25
Wright, S. A., & Gianchandani, Y. B. (2009) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2017110 · Cited by 24
Evolution of micromachined pressure transducers for cardiovascular applications
Starr, P., Bartels, K. A., Agrawal, M., et al. (2015) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2015.01.026 · Cited by 23
A Wireless Pressure Sensor for Continuous Monitoring of Intraocular Pressure in Conscious Animals
Bello, S. A., & Passaglia, C. L. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1896-3 · Cited by 23
Metadata
- Authors
- Song, P., Ma, Z., Ma, J., Yang, L., Wei, J., Zhao, Y., Zhang, M., Yang, F., & Wang, X.
- Venue
- Micromachines
- Publisher
- MDPI AG
- Published
- 2020-01-01
- Volume
- 11
- Issue
- 1
- Pages
- 56
- ISSN
- 2072-666X (ISSN-L)
- OpenAlex
- W2997394149
- Cited by
- 262
- References
- 92
- FWCI
- 10.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.