The DOI matches its Crossref record; 230 of the 233 references it cites were found in a registry or an index.
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Open accessAbstract
Annual deaths in the U.S. attributed to diabetes are expected to increase from 280,210 in 2015 to 385,840 in 2030. The increase in the number of people affected by diabetes has made it one of the major public health challenges around the world. Better management of diabetes has the potential to decrease yearly medical costs and deaths associated with the disease. Non-invasive methods are in high demand to take the place of the traditional finger prick method as they can facilitate continuous glucose monitoring. Research groups have been trying for decades to develop functional commercial non-invasive glucose measurement devices. The challenges associated with non-invasive glucose monitoring are the many factors that contribute to inaccurate readings. We identify and address the experimental and physiological challenges and provide recommendations to pave the way for a systematic pathway to a solution. We have reviewed and categorized non-invasive glucose measurement methods based on: (1) the intrinsic properties of glucose, (2) blood/tissue properties and (3) breath acetone analysis. This approach highlights potential critical commonalities among the challenges that act as barriers to future progress. The focus here is on the pertinent physiological aspects, remaining challenges, recent advancements and the sensors that have reached acceptable clinical accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The major problem with non‐invasive optical sensors is the specific measurement of glucose with sufficient analytical quality 109.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [109]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IDF Diabetes Atlas: Global estimates of diabetes prevalence for 2017 and projections for 2045
Cho, N. H., Shaw, J. E., Karuranga, S., Huang, Y., da Rocha Fernandes, J. D., Ohlrogge, A. W., & Malanda, B. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.02.023 · Cited by 7,283
Insulin signalling and the regulation of glucose and lipid metabolism
Saltiel, A. R., & Kahn, C. R. (2001) · Nature · doi:10.1038/414799a · Cited by 5,326
Gabriel, S., Lau, R.-W.-M., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,487
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
2. Classification and Diagnosis of Diabetes: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s002 · Cited by 3,159
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Raman and infrared spectroscopy of carbohydrates: A review
Wiercigroch, E., Szafraniec, E., Czamara, K., Pacia, M. Z., Majzner, K., Kochan, K., Kaczor, A., Barańśka, M., & Małek, K. (2017) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.05.045 · Cited by 1,078
The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration?
Beutler, E., & Waalen, J. (2005) · Blood · doi:10.1182/blood-2005-07-3046 · Cited by 971
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 842
Gonzales, W. V., Mobashsher, A. T., & Abbosh, A. M. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 820
Glucose Sensing for Diabetes Monitoring: Recent Developments
Bruen, D., Delaney, C., Florea, L., & Diamond, D. (2017) · Sensors · doi:10.3390/s17081866 · Cited by 796
Diabetes 2030: Insights from Yesterday, Today, and Future Trends
Rowley, W. R., Bezold, C., Arikan, Y., Byrne, E. N., & Krohe, S. (2016) · Population Health Management · doi:10.1089/pop.2015.0181 · Cited by 708
Dieringer, J. A., McFarland, A. D., Shah, N. C., Stuart, D. A., Whitney, A. V., Yonzon, C. R., Young, M. A., Zhang, X., & Duyne, R. P. V. (2005) · Faraday Discussions · doi:10.1039/b513431p · Cited by 598
Wearable non-invasive epidermal glucose sensors: A review
Kim, J., Campbell, A. S., & Wang, J. (2017) · Talanta · doi:10.1016/j.talanta.2017.08.077 · Cited by 595
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Anatomy and Physiology of the Skin
Kolarsick, P. A. J., Kolarsick, M. A., & Goodwin, C. (2011) · Journal of the Dermatology Nurses' Association · doi:10.1097/jdn.0b013e3182274a98 · Cited by 578
Diabetic emergencies - ketoacidosis, hyperglycaemic hyperosmolar state and hypoglycaemia
Umpierrez, G., & Korytkowski, M. (2016) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2016.15 · Cited by 563 · cited 1×
“Very high and dangerous levels of blood ketones can decrease plasma pH to low levels, and this can lead to coma or death if not reversed [41].”
BackgroundArtificial intelligence for diabetes management and decision support: Literature review
Contreras, I., & Vehi, J. (2018) · Journal of Medical Internet Research · doi:10.2196/10775 · Cited by 560
Diabetes mellitus and electrolyte disorders
Liamis, G. L. (2014) · World Journal of Clinical Cases · doi:10.12998/wjcc.v2.i10.488 · Cited by 406
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Electric Properties of Tissues
Damijan Miklavčič, A., Pavšelj, N., & Hart, F. X. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0403 · Cited by 379
Optical glucose sensing in biological fluids: an overview
McNichols, R. J., & Coté, G. L. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429962 · Cited by 369
Wiley Encyclopedia of Biomedical Engineering
Çetin, A. E., & Gerek, O. N. (2006) · Wiley eBooks · doi:10.1002/9780471740360 · Cited by 369
Tuchin, V. V. (2007) · SPIE eBooks · doi:10.1117/3.684093 · Cited by 361
An overview of dielectric properties measuring techniques
Raghavan, M. S. V. A. G. S. V. (2005) · Cited by 331
Maier, J., Walker, S. A., Fantini, S., Franceschini, M. A., & Gratton, E. (1994) · Optics Letters · doi:10.1364/ol.19.002062 · Cited by 318
Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
Choi, H., Naylon, J. A., Luzio, S. D., Beutler, J., Birchall, J. C., Martin, C., & Porch, A. (2015) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2472019 · Cited by 313
Gioia, A. L., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 305
Electrical impedance spectroscopy study of biological tissues
Dean, D. A., Ramanathan, T., Machado, D., & Sundararajan, R. (2008) · Journal of Electrostatics · doi:10.1016/j.elstat.2007.11.005 · Cited by 300
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 300
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290
Microwave-Based Noninvasive Concentration Measurements for Biomedical Applications
Hofmann, M., Fischer, G., Weigel, R., & Kissinger, D. (2013) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2013.2250516 · Cited by 289
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M. P., Liu, C.-P., & Mwakikunga, B. W. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 288
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
Continuous Glucose Monitoring Systems: A Review
Vashist, S. (2013) · Diagnostics · doi:10.3390/diagnostics3040385 · Cited by 261
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 256
Analysis of optical coherence tomography systems based on the extended Huygens–Fresnel principle
Thrane, L., Yura, H. T., & Andersen, P. E. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000484 · Cited by 248
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
Caduff, A., Hirt, E., Feldman, Y. D., Ali, Z., & Heinemann, L. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00196-9 · Cited by 248
Functionalized conjugated polymers for sensing and molecular imprinting applications
Anantha-Iyengar, G., Shanmugasundaram, K., Nallal, M., Lee, K.-P., Whitcombe, M. J., Lakshmi, D., & Saianand, G. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.08.001 · Cited by 239
Wang, C., Mbi, A., & Shepherd, M. D. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035730 · Cited by 236
Dielectric measurements with an open-ended coaxial probe
Marsland, T. P., & Evans, S. D. (1987) · IEE Proceedings H Microwaves Antennas and Propagation · doi:10.1049/ip-h-2.1987.0068 · Cited by 231
Breath Ethanol and Acetone as Indicators of Serum Glucose Levels: An Initial Report
Galassetti, P. R., Novak, B., Nemet, D., Rose-Gottron, C. M., Cooper, D. M., Meinardi, S., Newcomb, R. L., Zaldivar, F. P., & Blake, D. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.115 · Cited by 229
Recent advances in noninvasive glucose monitoring
Chung, J. W. Y., So, H., Choi, K., & Wong, T. K. S. (2012) · Medical Devices Evidence and Research · doi:10.2147/mder.s28134 · Cited by 225
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 222
Jeong, J. W., Arnob, M. M. P., Baek, K. M., Lee, S. Y., Shih, W., & Jung, Y. S. (2016) · Advanced Materials · doi:10.1002/adma.201602603 · Cited by 221
Hepatic and whole-body fat synthesis in humans during carbohydrate overfeeding
Aarsland, A. A., Chinkes, D. L., & Wolfe, R. R. (1997) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.6.1774 · Cited by 202
Rothwell, E. J., Frasch, J. L., Ellison, S. M., Chahal, P. P., & Ouedraogo, R. O. (2016) · Electromagnetic waves · doi:10.2528/pier16071706 · Cited by 201
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 200
Lazebnik, M., Converse, M., Booske, J. H., & Hagness, S. C. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/7/022 · Cited by 194
Neural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W. A., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 192
Turner, C., Walton, C., Hoashi, S., & Evans, M. L. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/4/046004 · Cited by 183
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Ávila-Navarro, E., & Sabater-Navarro, J. M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2866743 · Cited by 177
Saha, S. C., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I. A., Κουτσουπίδου, Μ., Palikaras, G. K., Mackenzie, R., Reeve, T., Kosmas, P., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06926-1 · Cited by 174
In Vivo Blood Glucose Quantification Using Raman Spectroscopy
Shao, J., Lin, M., Li, Y.-Q., Li, X., Liu, J., Liang, J., & Yao, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0048127 · Cited by 172
Yilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2313139 · Cited by 168
Sim, J. Y., Ahn, C.-G., Jeong, E.-J., & Kim, B. K. (2018) · Scientific Reports · doi:10.1038/s41598-018-19340-y · Cited by 167
Optical coherence tomography angiography: a review of current and future clinical applications
Ang, M., Tan, A. C. S., Cheung, C. M. G., Keane, P. A., Dolz‐Marco, R., Sng, C. C. A., & Schmetterer, L. F. (2018) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3896-2 · Cited by 167
Exhaled methyl nitrate as a noninvasive marker of hyperglycemia in type 1 diabetes
Novak, B., Blake, D. R., Meinardi, S., Rowland, F. S., Pontello, A. M., Cooper, D. M., & Galassetti, P. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706533104 · Cited by 164
Smolinska, A., Klaassen, E. M. M., Dallinga, J. W., van de Kant, K. D. G., Jöbsis, Q., Moonen, E. J. C., van Schayck, O. C. P., Dompeling, E., & van Schooten, F. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095668 · Cited by 163
Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155
The Appearance of Human Skin: A Survey
Igarashi, T., Nishino, K., & Nayar, S. K. (2007) · Foundations and Trends® in Computer Graphics and Vision · doi:10.1561/0600000013 · Cited by 154
Electromagnetic Characterisation of Materials by Using Transmission/Reflection (T/R) Devices
Costa, F., Borgese, M., Degiorgi, M., & Monorchio, A. (2017) · Electronics · doi:10.3390/electronics6040095 · Cited by 154
Atchudan, R., Nallal, M., Edison, T. N. J. I., Perumal, S., Vinodh, R., Park, K. H., & Lee, Y. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.049 · Cited by 153
Silicon-Based Sensors for Biomedical Applications: A Review
Xu, Y., Hu, X., Kundu, S., Nag, A., Afsarimanesh, N., Sapra, S., Mukhopadhyay, S. C., & Han, T. (2019) · Sensors · doi:10.3390/s19132908 · Cited by 153
A Deep Learning Approach to Diabetic Blood Glucose Prediction
Mhaskar, H. N., Pereverzev, S. V., & van der Walt, M. D. (2017) · Frontiers in Applied Mathematics and Statistics · doi:10.3389/fams.2017.00014 · Cited by 150
Busher, J. T. (1990) · Cited by 149
Larin, K. V., Motamedi, M., Ashitkov, T. V., & Esenaliev, R. O. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/310 · Cited by 147
Linear birefringence of the central human cornea.
Knighton, R. W., & Huang, X.-R. (2002) · PubMed · Cited by 147
Enhanced acetone sensing properties of titanium dioxide nanoparticles with a sub-ppm detection limit
Navale, S. T., Yang, Z., Liu, C., Cao, P., Patil, V. B., Ramgir, N. S., Mane, R. S., & Stadler, F. J. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.186 · Cited by 147
Non-Invasive Glucose Monitoring: A Review of Challenges and Recent Advances
Lin, T. (2017) · Current Trends in Biomedical Engineering & Biosciences · doi:10.19080/ctbeb.2017.06.555696 · Cited by 144
Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes
Hayashi, Y., Livshits, L., Caduff, A., & Feldman, Y. D. (2003) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/36/4/307 · Cited by 142
Rapid acetone detection using indium loaded WO3/SnO2 nanohybrid sensor
Tomer, V. K., Singh, K., Kaur, H., Shorie, M., & Sabherwal, P. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.179 · Cited by 137
Microscopic Imaging and Spectroscopy with Scattered Light
Boustany, N. N., Boppart, S. A., & Backman, V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124811 · Cited by 135
A microwave frequency sensor for non-invasive blood-glucose measurement
Jean, B. R., Green, E. C., & McClung, M. J. (2008) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2008.4472932 · Cited by 133
Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics
Kottmann, J., Rey, J. M., & Sigrist, M. W. (2016) · Sensors · doi:10.3390/s16101663 · Cited by 133
Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring
Goodarzi, M., Sharma, S., Ramón, H., & Saeys, W. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.005 · Cited by 130
PrFeO3 hollow nanofibers as a highly efficient gas sensor for acetone detection
Ma, L., Ma, S. Y., Shen, X. F., Wang, T. T., Jiang, X., Chen, Q., Qiang, Z., Yang, H., & Chen, H. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.09.060 · Cited by 128
Glucose-dependent dielectric properties of blood plasma
Topsakal, E., Karacolak, T., & Moreland, E. C. (2011) · doi:10.1109/ursigass.2011.6051324 · Cited by 127
Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy”
Amir, O., Weinstein, D., Zilberman, S., Less, M., Perl‐Treves, D., Primack, H., Weinstein, A., Gabis, E., Fikhte, B. A., & Karasik, A. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100403 · Cited by 125
The Appearance of Human Skin: A Survey
Igarashi, T., Nishino, K., & Nayar, S. K. (2007) · now publishers, Inc. eBooks · doi:10.1561/9781601980878 · Cited by 124
Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers
Kasahara, R., Kino, S., Soyama, S., & Matsuura, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.9.000289 · Cited by 123
Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
Anderson, J. C., Lamm, W. J., & Hlastala, M. P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00868.2005 · Cited by 118
Götzinger, E., Pircher, M., Sticker, M., FERCHER, A. F., & Hitzenberger, C. K. F. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629308 · Cited by 118
En face optical coherence tomography: a technology review [Invited]
Leitgeb, R. A. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.002177 · Cited by 118
Song, K., Ha, U., Park, S., Bae, J., & Yoo, H. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2384037 · Cited by 115
Glucose Sensing Using Surface-Enhanced Raman-Mode Constraining
Yang, D., Afroosheh, S., Lee, J. O., Cho, H., Kumar, S., Siddique, R. H., Narasimhan, V., Yoon, Y.-Z., Zayak, A. T., & Choo, H. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b03420 · Cited by 114
BEVING, H. F. G., Eriksson, L. E. G., Davey, C. L., & Kell, D. B. (1994) · European Biophysics Journal · doi:10.1007/bf01007612 · Cited by 113
Near-infrared LED based non-invasive blood glucose sensor
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2014) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2014.6777023 · Cited by 112
Caduff, A., Talary, M. S., Mueller, M. C., Dewarrat, F., Klisic, J., Donath, M. Y., Heinemann, L., & Stahel, W. A. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.02.001 · Cited by 109
Yi, J., & Backman, V. (2012) · Optics Letters · doi:10.1364/ol.37.004443 · Cited by 106
Zarkogianni, K., Mitsis, K., Litsa, E. E., Arredondo, M. T., Fico, G., Fioravanti, A., & Nikita, K. S. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1320-9 · Cited by 106
Precision of measurement of tissue optical properties with optical coherence tomography
Kholodnykh, A. I., Petrova, I. Y., Larin, K. V., Motamedi, M., & Esenaliev, R. O. (2003) · Applied Optics · doi:10.1364/ao.42.003027 · Cited by 106
Li, N., Zang, H., Sun, H., Jiao, X., Wang, K., Liu, T. C., & Meng, Y. (2019) · Molecules · doi:10.3390/molecules24081500 · Cited by 103
Rydosz, A. M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815572366 · Cited by 100
Reagentless Near-Infrared Determination of Glucose in Whole Blood Using Multivariate Calibration
Haaland, D. M., Robinson, M., Koepp, G. W., Thomas, E. V., & Eaton, R. P. (1992) · Applied Spectroscopy · doi:10.1366/000370292789619232 · Cited by 99
Dielectric properties of blood: an investigation of haematocrit dependence
Jaspard, F., Nadi, M., & Rouane, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/1/310 · Cited by 98
Temperature-Corrected Fluidic Glucose Sensor Based on Microwave Resonator
Jang, C., Park, J., Lee, H., Yun, G., & Yook, J. (2018) · Sensors · doi:10.3390/s18113850 · Cited by 97
A Novel Noninvasive Blood Glucose Monitor
Malchoff, C. D., Shoukri, K., Landau, J. I., & Buchert, J. M. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2268 · Cited by 96
Towards Accurate Dielectric Property Retrieval of Biological Tissues for Blood Glucose Monitoring
Yilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2365019 · Cited by 94
Linear techniques to correct for temperature-induced spectral variation in multivariate calibration
Wülfert, F., Kok, W. T., de Noord, O. E., & Smilde, A. K. (2000) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(00)00069-1 · Cited by 92
Pendra goes Dutch: lessons for the CE mark in Europe
Wentholt, I. M. E., Hoekstra, J. B. L., Zwart, A., & DeVries, J. H. (2005) · Diabetologia · doi:10.1007/s00125-005-1754-y · Cited by 90
Advances in surface-enhanced Raman spectroscopy for analysis of pharmaceuticals: A review
Alula, M. T., Mengesha, Z. T., & Mwenesongole, E. M. (2018) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2018.06.013 · Cited by 90
A Noninvasive Measurement of Blood Glucose Concentration by UWB Microwave Spectrum
Xiao, X., & Li, Q. (2016) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2016.2618946 · Cited by 86
Harman‐Boehm, I., Gal, A., Raykhman, A. M., Naidis, E., & Mayzel, Y. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400312 · Cited by 85
Noninvasive Polarimetric-Based Glucose Monitoring: An in Vivo Study
Purvinis, G., Cameron, B. D., & Altrogge, D. M. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500227 · Cited by 83
Cobelli, C., Schiavon, M., Man, C. D., Basu, A., & Basu, R. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0112 · Cited by 83
Critical-depth Raman spectroscopy enables home-use non-invasive glucose monitoring
Lundsgaard-Nielsen, S. M., Pors, A., Banke, S. O., Henriksen, J. E., Hepp, D. K., & Weber, A. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197134 · Cited by 83
Study of the Exhaled Acetone in Type 1 Diabetes Using Quantum Cascade Laser Spectroscopy
Reyes-Reyes, A., Horsten, R., Urbach, H. P., & Bhattacharya, N. (2014) · Analytical Chemistry · doi:10.1021/ac504235e · Cited by 82
Dielectric properties of blood: an investigation of temperature dependence
Jaspard, F., & Nadi, M. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/3/306 · Cited by 82
Rogers, J. D., Radosevich, A. J., Yi, J., & Backman, V. (2013) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2280999 · Cited by 81
Quantifying the Composition of Human Skin for Glucose Sensor Development
Groenendaal, W., von Basum, G., Schmidt, K. A., Hilbers, P. A. J., & van Riel, N. A. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400502 · Cited by 79
Microwave noninvasive blood glucose monitoring sensor: Human clinical trial results
Choi, H., Luzio, S. D., Beutler, J., & Porch, A. (2017) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2017.8058721 · Cited by 77
Effect of temperature, pH, and corneal birefringence on polarimetric glucose monitoring in the eye
Baba, J. S., Cameron, B. D., & Coté, G. L. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1484163 · Cited by 76
Maruo, K., & Yamada, Y. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.4.047003 · Cited by 73
Storer, M., Dummer, J. F., Lunt, H., Scotter, J., McCartin, F., Cook, J., Swanney, M. P., Kendall, D., Logan, F. J., & Epton, M. (2011) · Journal of Breath Research · doi:10.1088/1752-7155/5/4/046011 · Cited by 72
Infrared Spectroscopy in Clinical and Diagnostic Analysis
Shaw, R. A., & Mantsch, H. H. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0106 · Cited by 72
Impedance spectroscopy of solutions at physiological glucose concentrations
Tura, A., Sbrignadello, S., Barison, S., Conti, S., & Pacini, G. (2007) · Biophysical Chemistry · doi:10.1016/j.bpc.2007.06.001 · Cited by 70
Measurements of the corneal birefringence with a liquid-crystal imaging polariscope
Bueno, J. M., & Vargas-Martı́n, F. (2002) · Applied Optics · doi:10.1364/ao.41.000116 · Cited by 70
A novel multicomponent redox polymer nanobead based high performance non-enzymatic glucose sensor
Gopalan, A., Nallal, M., Komathi, S., & Lee, K.-P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.079 · Cited by 68
Cylindrical Dielectric Resonator Antenna Sensor for Non-Invasive Glucose Sensing Application
Hasan, M. N., Tamanna, S., Singh, P., Nadeem, M. D., & Rudramuni, M. (2019) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2019.8711633 · Cited by 68
Fibroblast Cells: A Sensing Bioelement for Glucose Detection by Impedance Spectroscopy
Tlili, C., Reybier, K., Géloën, A., Ponsonnet, L., Martelet, C., Ouada, H. B., Lagarde, M., & Jaffrezic-Renault, N. J. (2003) · Analytical Chemistry · doi:10.1021/ac0340861 · Cited by 66
Reyes-Vera, E., Acevedo-Osorio, G., Arias-Correa, M., & Senior, D. E. (2019) · Sensors · doi:10.3390/s19081936 · Cited by 66
Investigation of the effect of dehydration on tissue dielectric properties in ex vivo measurements
Shahzad, A., Khan, S., Jones, M., Dwyer, R. M., & O’Halloran, M. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aa74c4 · Cited by 64
Nirala, N., Periyasamy, R., Singh, B. K., & Kumar, A. (2018) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2018.09.007 · Cited by 63
Glucose Concentration Measurement in Human Blood Plasma Solutions with Microwave Sensors
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., & Sabater-Navarro, J. M. (2019) · Sensors · doi:10.3390/s19173779 · Cited by 63
Monitoring of glucose permeability in monkey skin in vivo using Optical Coherence Tomography
Ghosn, M. G., Sudheendran, N., Wendt, M., Glasser, A., Tuchin, V. V., & Larin, K. V. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910075 · Cited by 63
A Biophysically‐Based Model of the Optical Properties of Skin Aging
Iglesias-Guitián, J. A., Aliaga, C., Jarabo, A., & Gutiérrez, D. (2015) · Computer Graphics Forum · doi:10.1111/cgf.12540 · Cited by 62
Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
Siegel, P. H., Lee, Y., & Pikov, V. (2014) · International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz) · doi:10.1109/irmmw-thz.2014.6956294 · Cited by 62
Turgul, V., & Kale, İ. (2016) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2016.7520546 · Cited by 62
Geng, Z., Tang, F., Ding, Y., Li, S., & Wang, X. (2017) · Scientific Reports · doi:10.1038/s41598-017-13018-7 · Cited by 61
Sun, M., Chen, Z., Gong, Z., Zhao, X., Jiang, C., Yuan, Y., Wang, Z., Li, Y., & Wang, C. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8401-8 · Cited by 61
Song, K., Ha, U., Park, S., & Yoo, H. (2014) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2014.6858407 · Cited by 60
Li, J., Igbe, T., Liu, Y., Nie, Z., Qin, W., Wang, L., & Hao, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2866601 · Cited by 60
Jiang, C., Sun, M., Wang, Z., Chen, Z., Zhao, X., Yuan, Y., Li, Y., & Wang, C. (2016) · Sensors · doi:10.3390/s16081199 · Cited by 60
A cross-sectional study of breath acetone based on diabetic metabolic disorders
Li, W., Liu, Y., Lu, X., Huang, Y., Liu, Y., Cheng, S.-Q., & Duan, Y. (2015) · Journal of Breath Research · doi:10.1088/1752-7155/9/1/016005 · Cited by 57
Blood Glucose Measurement Using Bioimpedance Technique
Kamat, D. K., Bagul, D., & Patil, P. M. (2014) · Advances in Electronics · doi:10.1155/2014/406257 · Cited by 56
Requirements for Calibration in Noninvasive Glucose Monitoring by Raman Spectroscopy
Lipson, J., Bernhardt, J., Block, U. L., Freeman, W. R., Hofmeister, R. T., Hristakeva, M., Lenosky, T. J., McNamara, R., Petrasek, D., Veltkamp, D. J., et al. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300203 · Cited by 56
Review: Non-Invasive Continuous Blood Glucose Measurement Techniques
Nawaz, A., Øhlckers, P. A., Sælid, S., Jacobsen, M., & Akram, M. N. (2016) · Journal of Bioinformatics and Diabetes · doi:10.14302/issn.2374-9431.jbd-15-647 · Cited by 55
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Stokes-Mueller matrix polarimetry system for glucose sensing
Phan, Q.-H., & Lo, Y. (2016) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2016.08.017 · Cited by 54
Dielectric inspection of erythrocyte morphology
Hayashi, Y., Oshige, I., Katsumoto, Y., Omori, S., Yasuda, A., & Asami, K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/10/007 · Cited by 53
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52
Forst, T., Caduff, A., Talary, M., Weder, M., Brändle, M., Kann, P., Flacke, F., Friedrich, C., & Pfützner, A. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.94 · Cited by 51
Kuranov, R. V., Sapozhnikova, V. V., Prough, D. S., Cicenaite, I., & Esenaliev, R. O. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/16/001 · Cited by 50
Saager, R. B., Quach, A., Rowland, R. A., Baldado, M. L., & Durkin, A. J. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.6.067001 · Cited by 49
Nallal, M., Gopalan, A., & Lee, K.-P. (2018) · RSC Advances · doi:10.1039/c7ra09097h · Cited by 49
Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography
Chen, T.-L., Lo, Y., Liao, C.-C., & Phan, Q.-H. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.047001 · Cited by 49
Computing the Surveillance Error Grid Analysis
Kovatchev, B. P., WAKEMAN, C. A., Breton, M. D., Kost, G. J., Louie, R. F., Tran, N. K., & Klonoff, D. C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814539590 · Cited by 47
Conformal and Disposable Antenna-Based Sensor for Non-Invasive Sweat Monitoring
Eldamak, A. R., & Fear, E. C. (2018) · Sensors · doi:10.3390/s18124088 · Cited by 47
Lan, Y., Kuang, Y., Zhou, L. P., Wu, G., Gu, P., Wei, H., & Chen, K. (2017) · Laser Physics Letters · doi:10.1088/1612-202x/aa58c0 · Cited by 47
Basic Concepts in Clinical Biochemistry: A Practical Guide
Kumar, V., & Gill, K. D. (2018) · Springer eBooks · doi:10.1007/978-981-10-8186-6 · Cited by 47
Highly-Sensitive Glucose Concentration Sensor Exploiting Inter-resonators Couplings
Juan, C. G., Potelon, B., Quendo, C., Bronchalo, E., & Sabater-Navarro, J. M. (2019) · European Microwave Conference (EuMC) · doi:10.23919/eumc.2019.8910847 · Cited by 47
Cutaneous Blood Perfusion as a Perturbing Factor for Noninvasive Glucose Monitoring
Caduff, A., Talary, M. S., & Zakharov, P. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0095 · Cited by 46
Komathi, S., Gopalan, A., Nallal, M., & Lee, K.-P. (2017) · RSC Advances · doi:10.1039/c6ra24760a · Cited by 43
Torul, H., Çiftçi, H., Dudak, F. C., Adıgüzel, Y., Külah, H., Boyacı, İ. H., & Tamer, U. (2014) · Analytical Methods · doi:10.1039/c4ay00559g · Cited by 39
Exhaled Breath Isoprene Rises During Hypoglycemia in Type 1 Diabetes
Neupane, S., Peverall, R., Richmond, G., Blaikie, T. P. J., Taylor, D., Hancock, G., & Evans, M. L. (2016) · Diabetes Care · doi:10.2337/dc16-0461 · Cited by 39
Modeling and Measurement of Correlation between Blood and Interstitial Glucose Changes
Shi, T., Li, D., Li, G., Zhang, Y., Xu, K., & Lu, L. (2016) · Journal of Diabetes Research · doi:10.1155/2016/4596316 · Cited by 38
Wan, X., Li, G., Zhang, M., Yan, W., He, G., Awelisah, Y. M., & Lin, L. (2019) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2019.1584567 · Cited by 38
Balaguera, E. H., López‐Dolado, E., & Polo, J. L. (2016) · RSC Advances · doi:10.1039/c5ra24535d · Cited by 38
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36
Ballerstädt, R., Kholodnykh, A. I., Evans, C., Boretsky, A. R., Motamedi, M., Gowda, A., & McNichols, R. J. (2007) · Analytical Chemistry · doi:10.1021/ac0707434 · Cited by 36
Malik, B. H., & Coté, G. L. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3447923 · Cited by 35
Non-invasive monitoring of diabetes through analysis of the exhaled breath condensate (aerosol)
Karyakin, A. A., Никулина, С. В., Vokhmyanina, D. V., Karyakina, E. E., Anaev, E. K., & Чучалин, А. Г. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.09.005 · Cited by 35
Wood, M. F. G., Côté, D. C., & Vitkin, I. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2968198 · Cited by 35
Extended Near-Infrared Optoacoustic Spectrometry for Sensing Physiological Concentrations of Glucose
Ghazaryan, A. A., Ovsepian, S. V., & Ntziachristos, V. (2018) · Frontiers in Endocrinology · doi:10.3389/fendo.2018.00112 · Cited by 34
Hadar, E., Chen, R., Toledano, Y., Tenenbaum-Gavish, K., Atzmon, Y., & Hod, M. (2018) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767058.2018.1463987 · Cited by 33
Kinnunen, M. T., Myllylä, R. A., & Vainio, S. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2904957 · Cited by 33
Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments
Pfützner, A., Strobl, S., Demircik, F., Redert, L., Pfützner, J., Pfützner, A. H., & Lier, A. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818758769 · Cited by 33
Westphal, P., Kaltenbach, J.-M., & Wicker, K. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.001160 · Cited by 33
Breath Acetone as Biomarker for Lipid Oxidation and Early Ketone Detection
Prabhakar, A., Ashley, Q., Wang, D., Haojiong, Z., Terrera, M., David, J., Xian, X., Francis, T., Tao, N. J., & Forzani, E. (2014) · Global Journal of Obesity Diabetes and Metabolic Syndrome · doi:10.17352/2455-8583.000003 · Cited by 33
Zhang, Y., Wu, G., Wei, H., Guo, Z., Yang, H., He, Y., Xie, S., & Liu, Y. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000990 · Cited by 32
Singh, S. P., Mukherjee, S., Galindo, L. H., So, P. T. C., Dasari, R. R., Khan, U. Z., Kannan, R., Upendran, A., & Kang, J. W. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1244-y · Cited by 31
Influence of osmolarity on the optical properties of human erythrocytes
Friebel, M. F., Helfmann, J., & Meinke, M. C. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3486542 · Cited by 31
Instrument for near infrared emission spectroscopic probing of human fingertips in vivo
Chaiken, J., Deng, B., Bussjager, R. J., Shaheen, G., Rice, D. A., Stehlik, D., & Fayos, J. (2010) · Review of Scientific Instruments · doi:10.1063/1.3314290 · Cited by 30
Zanon, M., Mueller, M., Zakharov, P., Talary, M. S., Donath, M. Y., Stahel, W. A., & Caduff, A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817740591 · Cited by 30
Effect on blood glucose monitoring of skin pressure exerted by an optical coherence tomography probe
Sapozhnikova, V. V., Kuranov, R. V., Cicenaite, I., Esenaliev, R. O., & Prough, D. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2909671 · Cited by 29
Optical polarimetry for noninvasive glucose sensing enabled by Sagnac interferometry
Winkler, A. M., Bonnema, G. T., & Barton, J. K. (2011) · Applied Optics · doi:10.1364/ao.50.002719 · Cited by 29
Non-Invasive Glucose Monitoring Techniques: A review and current trendsPreprint
Poddar, R., Andrews, J. T., Shukla, P., & Sen, P. (2008) · arXiv (Cornell University) · doi:10.48550/arxiv.0810.5755 · Cited by 28
Liu, G., Huang, K., Jia, Q., Liu, S., Shen, S., Li, J., Dong, E., Lemaillet, P., Allen, D. W., & Xu, R. X. (2018) · Applied Optics · doi:10.1364/ao.57.006772 · Cited by 28
Biomedical Optics in Otorhinolaryngology
Wong, B. J. F., Ilgner, J. F. R., Witjes, M. J. H., de Visscher, S. A. H. J., & Roodenburg, J. L. N. (2016) · Springer eBooks · doi:10.1007/978-1-4939-1758-7 · Cited by 27
New equivalent-electrical circuit model and a practical measurement method for human body impedance
Chinen, K., Kinjo, I., Zamami, A., Irei, K., & Nagayama, K. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151369 · Cited by 26
Fluorescence quenching of albumin. A spectrofluorimetric experiment
Montero, M. T., Hernández‐Borrell, J., & Estelrich, J. (1990) · Biochemical Education · doi:10.1016/0307-4412(90)90188-t · Cited by 26
Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo
Caduff, A., Ishai, P. B., & Feldman, Y. D. (2019) · Biophysical Reviews · doi:10.1007/s12551-019-00601-7 · Cited by 25
Sun, M., Zhao, X., Yin, H., Wang, Z., Jiang, C., Liu, W., Chen, Z., Yuan, Y., Li, Y., & Wang, C. (2015) · RSC Advances · doi:10.1039/c5ra07084h · Cited by 25
Yuan, Y., Chen, Z., Zhao, X., Sun, M., Li, Y., Wang, Z., & Wang, C. (2017) · Journal of Analytical & Bioanalytical Techniques · doi:10.4172/2155-9872.1000386 · Cited by 25
Saitô, T., Ishikawa, S., Higashiyama, M., Nakamura, T., Rokkaku, K., Hayashi, H., Kusaka, I., Nagasaka, S., & Saito, T. (1999) · Endocrine Journal · doi:10.1507/endocrj.46.75 · Cited by 24
On the suitability of refractometry for the analysis of glucose in blood-derived fluids
Zirk, K., & Pötzschke, H. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.03.008 · Cited by 24
Wang, S., Sherlock, T., Salazar, B., Sudheendran, N., Manapuram, R. K., Kourentzi, K. D., Ruchhoeft, P., Willson, R. C., & Larin, K. V. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2270008 · Cited by 23
Kirillin, M., Priezzhev, A. V., Kinnunen, M. T., Alarousu, E., Zhao, Z., Hast, J. T., & Myllyl�, R. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.535341 · Cited by 23
Influence of Osmolytes on In Vivo Glucose Monitoring Using Optical Coherence Tomography
Sapozhnikova, V. V., Prough, D. S., Kuranov, R. V., Cicenaite, I., & Esenaliev, R. O. (2006) · Experimental Biology and Medicine · doi:10.1177/153537020623100806 · Cited by 22
Pretto, L. R. D., Yoshimura, T. M., Ribeiro, M. S., & de Freitas, A. Z. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.086007 · Cited by 22
Data Processing for Noninvasive Continuous Glucose Monitoring with a Multisensor Device
Mueller, M. C., Talary, M. S., Falco, L., Feo, O. D., Stahel, W. A., & Caduff, A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500324 · Cited by 21
Molar extinction coefficients of some carbohydrates in aqueous solutions
Singh, K., Sandhu, G. K., Lark, B., & Sud, S. (2002) · Pramana · doi:10.1007/s12043-002-0061-0 · Cited by 20
Caduff, A., Zanon, M., Zakharov, P., Mueller, M., Talary, M., Krebs, A., Stahel, W. A., & Donath, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817750932 · Cited by 17
Phase contrast coherence microscopy based on transverse scanning
Pircher, M., Baumann, B., Götzinger, E., Sattmann, H., & Hitzenberger, C. K. F. (2009) · Optics Letters · doi:10.1364/ol.34.001750 · Cited by 17
Sbrignadello, S., Tura, A., & Ravazzani, P. (2012) · Journal of Spectroscopy · doi:10.1155/2013/571372 · Cited by 16
Huber, D., Talary, M. S., Dewarrat, F., & Caduff, A. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0229-3 · Cited by 16
Dual-modulation, dual-wavelength, optical polarimetry system for glucose monitoring
Yu, Z. F., Pirnstill, C. W., & Coté, G. L. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.087001 · Cited by 16
Noninvasive Blood Glucose Measurement
Uwadaira, Y., & Ikehata, A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812019-4.00036-2 · Cited by 15
Flagged first, then by citations
3 of the 233 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Lide, D.R. (2005). CRC Handbook of Chemistry and Physics, CRC Press. [85th ed.].
Cited by
Sorted by citations
Non-Invasive Blood Glucose Monitoring Technology: A Review
Tang, L., Chang, S. J., Chen, C.-J., & Liu, J.-T. (2020) · Sensors · doi:10.3390/s20236925 · Cited by 481
Kiani, S., Rezaei, P., & Fakhr, M. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3052011 · Cited by 228
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210
“The major problem with non‐invasive optical sensors is the specific measurement of glucose with sufficient analytical quality [109].”
BackgroundGlucose Detection Devices and Methods Based on Metal–Organic Frameworks and Related Materials
Adeel, M., Asif, K., Rahman, M. M., Daniele, S., Canzonieri, V., & Rizzolio, F. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202106023 · Cited by 182
Firouzi, F., Farahani, B., Daneshmand, M., Grise, K., Song, J., Saracco, R., Wang, L. L., Lo, K., Angelov, P. P., Soares, E. A., et al. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3073904 · Cited by 158
Metadata
- Authors
- Shokrekhodaei, M., & Quinones, S.
- Affiliations
- The University of Texas at El Paso (US)
- Department of Metallurgical, Materials and Biomedical Engineering, The University of Texas at El Paso, El Paso, TX 79968, USA
- Corresponding author
- Shokrekhodaei, Maryamsadat
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-02-25
- Volume
- 20
- Issue
- 5
- Pages
- 1251
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7085605
- OpenAlex
- W3007868482
- Cited by
- 221
- References
- 233
- Citations by year
- 2026: 23 · 2025: 31 · 2024: 36 · 2023: 38 · 2022: 38 · 2021: 41 · 2020: 14
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- University of Texas at El Paso
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- non-invasive glucose monitoring, diabetes mellitus, continuous glucose monitoring, optical glucose sensor, clinical accuracy
- MeSH terms
- Acetone, Blood Glucose, Breath Tests, Electricity, Humans, Biosensing Techniques, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review