Recent Progress in Flexible Wearable Sensors for Vital Sign Monitoring
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
With the development of flexible electronic materials, as well as the wide development and application of smartphones, the cloud, and wireless systems, flexible wearable sensor technology has a significant and far-reaching impact on the realization of personalized medical care and the reform of the consumer market in the future. However, due to the high requirements for accuracy, reliability, low power consumption, and less data error, the development of these potential areas is full of challenges. In order to solve these problems, this review mainly searches the literature from 2008 to May 2020, based on the PRISMA process. Based on them, this paper reviews the latest research progress of new flexible materials and different types of sensors for monitoring vital signs (including electrophysiological signals, body temperature, and respiratory frequency) in recent years. These materials and sensors can help realize accurate signal detection based on comfortable and sustainable observation, and may likely be applied to future daily clothing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The stability of an electrically robust and conformal connection between the skin and device is still one of the main challenges in this type of sensor, which generally requires a conductive gel for operation to reduce the electrical impedance at the contact point130.”
From End-to-end design of wearable sensors (2022) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Self-citationImani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807 · cited 1×
“[75] developed a portable non-invasive sensor, namely, the essential electronic system (EES), which only needs water to attach the sensor to the skin, so as to monitor the vital signs without restriction.”
BackgroundMachine-knitted washable sensor array textile for precise epidermal physiological signal monitoring
Fan, W., He, Q., Meng, K., Tan, X., Zhou, Z., Zhang, G., Yang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aay2840 · Cited by 516 · cited 1×
“[92] proposed a friction electric full textile sensor array with high pressure sensitivity and comfort.”
BackgroundA Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
Stretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359
Pay attention!: designing adaptive agents that monitor and improve user engagement
Szafir, D., & Mutlu, B. (2012) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2207679 · Cited by 304
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253 · cited 1×
“The whole system only needs a ce tralized on-body power supply, thus significantly reducing the size of the whole system [73].”
BackgroundWearable silver nanowire dry electrodes for electrophysiological sensing
Myers, A. C., Huang, H., & Zhu, Y. (2015) · RSC Advances · doi:10.1039/c4ra15101a · Cited by 231 · cited 4×
“Non-implantable flexible electrophysiological signal sensors: (a) schematic diagram of the transfer process and a photograph of the transparent graphene on plastic substrate [29]© 2013 IEEE; (b) Schematic image of wearable patches [31]© 2018 IEEE; (c) Ag NW electrodes on the forearm for EMG sensing (with black caps) a…”
BackgroundInfluentialWearable System Based on Flexible FBG for Respiratory and Cardiac Monitoring
Lo Presti, D., Massaroni, C., D'Abbraccio, J., Massari, L., Caponero, M., Longo, U. G., Formica, D., Oddo, C. M., & Schena, E. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2916320 · Cited by 219
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016) · Scientific Reports · doi:10.1038/srep33526 · Cited by 213
An Ultra Low Power Personalizable Wrist Worn ECG Monitor Integrated With IoT Infrastructure
Beach, C., Krachunov, S., Pope, J., Fafoutis, X., Piechocki, R. J., Craddock, I., & Casson, A. J. (2018) · IEEE Access · doi:10.1109/access.2018.2864675 · Cited by 91 · cited 5×
“Contact wearable monitoring se sor : (a) Arm-mounted electrocardiograph (ECG) acquisition equipment [10]; (b) data transmission between infrared PPG tra smission bel and USB and a comparison of PPG/ECG s gnals in the multiple ccess system [55]; ( ) bottom view of the case of the elec rode in contact wi h the wrist [11…”
BackgroundMethodInfluential
Research works printed but not linked: 96
- Pourkheyrollah, 2019, Highly conformable stretchable dry electrodes based on inexpensive flex substrate for long-term biopotential (EMG/ECG) monitoring, Sens. Actuators Phys., 295, 678, 10.1016/j.sna.2019.06.041 · DOI
- Sun, 2016, Capacitive biopotential measurement for electrophysiological signal acquisition: A review, IEEE Sens. J., 16, 2832, 10.1109/JSEN.2016.2519392 · DOI · Paper page
- Zhang, L. (2020). Design, Fabrication and Performance Study of the Flexible Supercapacitor Electrode. [Ph.D. Thesis, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences].
- Zhang, 2020, Highly stretchable polymer/silver nanowires composite sensor for human health monitoring, Nano Res., 13, 919, 10.1007/s12274-020-2730-z · DOI
- Lam, C.L., Saleh, S.M., Yudin, M.B.M., Harun, F.K., Sriprachuabwong, C., Tuantranont, A., and Wicaksono, D.H. (2017, January 6–7). Graphene Ink-Coated Cotton Fabric-Based Flexible Electrode for Electrocardiography. Proceedings of the 2017 5th International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering (ICICI-BME), Bandung, Indonesia. · doi:10.1109/icici-bme.2017.8537771
- Zahed, 2020, Flexible and robust dry electrodes based on electroconductive polymer spray-coated 3D porous graphene for long-term electrocardiogram signal monitoring system, Carbon, 165, 26, 10.1016/j.carbon.2020.04.031 · DOI
- Villegas, A., McEneaney, D., and Escalona, O. (2019). Arm-ECG Wireless Sensor System for Wearable Long-Term Surveillance of Heart Arrhythmias. Electronics, 8. · DOI
- Kosmyna, N., Morris, C., Sarawgi, U., Nguyen, T., and Maes, P. (2019, January 19–22). AttentivU: A Wearable Pair of EEG and EOG Glasses for Real-Time Physiological Processing. Proceedings of the 2019 IEEE 16th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Chicago, IL, USA. · DOI
- Li, X., and Sun, Y. (2017, January 17–19). NCMB-Button: A Wearable Non-contact System for Long-Term Multiple Biopotential Monitoring. Proceedings of the 2017 IEEE/ACM International Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE), Philadelphia, PA, USA. · DOI
- Liu, S., Liu, X., Jiang, Y., Wang, X., Huang, P., Wang, H., Zhu, M., Tan, J., Li, P., and Lin, C. (2018, January 18–21). Flexible Non-contact Electrodes for Bioelectrical Signal Monitoring. Proceedings of the 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Honolulu, HI, USA. · DOI
- Wang, X., Liu, S., Zhu, M., Liu, Z., Jiang, Y., Wang, D., Li, P., Samuel, O.W., Wu, W., and Chen, S. (2019, January 4–9). Performance of Flexible Non-contact Electrodes in Bioelectrical Signal Measurements. Proceedings of the 2019 IEEE International Conference on Real-time Computing and Robotics (RCAR), Irkutsk, Russia. · doi:10.1109/rcar47638.2019.9044127
- Gao, Y., Soman, V.V., Lombardi, J.P., Rajbhandari, P.P., Dhakal, T.P., Wilson, D., Poliks, M., Ghose, K., Turner, J.N., and Jin, Z. (2019). Heart Monitor Using Flexible Capacitive ECG Electrodes. IEEE Trans. Instrum. Meas. · DOI
- Christian, 2019, A Novel Wearable Device for Continuous Ambulatory ECG Recording: Proof of Concept and Assessment of Signal Quality, Biosensors, 9, 17, 10.3390/bios9010017 · DOI
- Wang, L.-H., Zhang, W., Guan, M.-H., Jiang, S.-Y., Fan, M.-H., Abu, P.A.R., Chen, C.-A., and Chen, S.-L. (2019). A Low-Power High-Data-Transmission Multi-Lead ECG Acquisition Sensor System. Sensors, 19. · DOI
- Chen, 2020, Design of an Integrated Wearable Multi-Sensor Platform Based on Flexible Materials for Neonatal Monitoring, IEEE Access, 8, 23732, 10.1109/ACCESS.2020.2970469 · DOI
- Yapici, M.K., and Alkhidir, T.E. (2017). Intelligent Medical Garments with Graphene-Functionalized Smart-Cloth ECG Sensors. Sensors, 17. · DOI · Paper page
- Al-Othman, A., Alatoom, A., Farooq, A., Al-Sayah, M., and Al-Nashash, H. (2018, January 28–30). Novel flexible implantable electrodes based on conductive polymers and Titanium dioxide. Proceedings of the 2018 IEEE 4th Middle East Conference on Biomedical Engineering (MECBME), Gammarth, Tunis. · DOI
- Lee, 2017, Flexible and implantable capacitive microelectrode for bio-potential acquisition, Biochip. J., 11, 153, 10.1007/s13206-017-1304-y · DOI
- Lee, 2016, Miniaturized Human Insertable Cardiac Monitoring System with Wireless Power Transmission Technique, J. Sens., 2016, 1
- Jiuwei, 2020, Flexible Sensing Technology for Bioelectricity, Mater. Rep., 34, 1095
- Smith, 2017, Comparison of diagnostic value using a small, single channel, P-wave centric sternal ECG monitoring patch with a standard 3-lead Holter system over 24 hours, Am. Heart J., 185, 67, 10.1016/j.ahj.2016.11.006 · DOI
- Yang, 2019, The causes and suppression methods of motion artifacts of wearable textile electrocardio-electrodes, Basic Sci. J. Text. Univ., 32, 126
- Wang, 2017, Continuous Fabrication of Highly Conductive and Transparent Ag Mesh Electrodes for Flexible Electronics, IEEE Trans. Nanotechnol., 16, 687, 10.1109/TNANO.2017.2705173 · DOI
- Nguyen, B.H., and Nguyen, V.H. (2016). Promising applications of graphene and graphene-based nanostructures. Adv. Nat. Sci.-Nanosci. Nanotechnol., 7. · DOI · Paper page
- Kalita, G., Wakita, K., Umeno, M., Hayashi, Y., and Tanemura, M. (2013, January 2–4). Synthesis of Continuous Graphene on Metal Foil for Flexible Transparent Electrode Application. Proceedings of the 2013 IEEE 5th International Nanoelectronics Conference, New York, NY, USA. · doi:10.1109/inec.2013.6466023
- Kondo, M., Fujita, T., Kanda, K., and Maenaka, K. (2019, January 7–10). Nanocarbon Electrode for Wearable Device with Flexible Material. Proceedings of the 2019 International Conference on Machine Learning and Cybernetics (ICMLC), Kobe, Japan. · doi:10.1109/icmlc48188.2019.8949223
- Jung, H., Kwon, D., Lee, S., Ahn, J., Kim, A., Kim, Y., and Moon, J. (2018, January 7–9). Carbon Based Electrode for Wearable Biosignal Monitoring Patch. Proceedings of the 2018 International Flexible Electronics Technology Conference (IFETC), Ottawa, ON, Canada. · DOI
- Zhang, Y., Liang, B., Jiang, Q.F., Li, Y., Feng, Y., Zhang, L.Q., Zhao, Y.M., and Xiong, X.L. (2020). Flexible and wearable sensor based on graphene nanocomposite hydrogels. Smart Mater. Struct., 29. · DOI
- Wang, 2012, PDMS-based low cost flexible dry electrode for long-term EEG measurement, IEEE Sens. J., 12, 2898, 10.1109/JSEN.2012.2204339 · DOI · Paper page
- Meng, 2015, A flexible dry micro-dome electrode for ECG monitoring, Microsyst. Technol., 21, 1241, 10.1007/s00542-014-2235-3 · DOI
- Wang, 2017, A microneedle electrode array on flexible substrate for long-term EEG monitoring, Sens. Actuators B Chem., 244, 750, 10.1016/j.snb.2017.01.052 · DOI
- Bai, 2019, Design of Electromyography Wireless Acquisition System Based on Flexible Dry Electrodes, Micronanoelectron. Technol., 56, 556
- Yang, B. (2017). Study on Capacitive Coupling Human Vital Signs Measurement. [Ph.D. Thesis, Tsinghua University].
- Li, X., and Sun, Y. (2017, January 16–19). Design and evaluation of a non-contact wireless biopotential monitoring system with motion artifacts. Proceedings of the 2017 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), Orland, FL, USA. · DOI
- Fuketa, 2014, 1 μm-Thickness Ultra-Flexible and High Electrode-Density Surface Electromyogram Measurement Sheet with 2 V Organic Transistors for Prosthetic Hand Control, IEEE Trans. Biomed. Circuits Syst., 8, 824, 10.1109/TBCAS.2014.2314135 · DOI
- Arzbaecher, 2010, Subcutaneous electrocardiogram monitors and their field of view, J. Electrocardiol., 43, 601, 10.1016/j.jelectrocard.2010.05.017 · DOI
- Charvet, G., Foerster, M., Chatalic, G., Michea, A., Porcherot, J., Bonnet, S., Filipe, S., Audebert, P., Robinet, S., and Josselin, V. (September, January 28). A wireless 64-channel ECoG recording electronic for implantable monitoring and BCI applications: WIMAGINE. Proceedings of the 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, San Diego, CA, USA. · DOI
- Dong, 2017, Flexible ECoG electrode for implantation and neural signal recording applications, Vacuum, 140, 96, 10.1016/j.vacuum.2016.12.024 · DOI
- Wu, 2019, An implantable and versatile piezoresistive sensor for the monitoring of human-machine interface interactions and the dynamical process of nerve repair, Nanoscale, 11, 21103, 10.1039/C9NR03925B · DOI
- Chamanzar, M., Borysov, M., Maharbiz, M.M., and Blanche, T.J. (2014, January 26–30). High-density optrodes for multi-scale electrophysiology and optogenetic stimulation. Proceedings of the 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, USA. · DOI
- Shin, 2019, Bioresorbable optical sensor systems for monitoring of intracranial pressure and temperature, Sci. Adv., 5, eaaw1899, 10.1126/sciadv.aaw1899 · DOI · Paper page
- Phan, 2019, Long-Lived, Transferred Crystalline Silicon Carbide Nanomembranes for Implantable Flexible Electronics, ACS Nano, 13, 11572, 10.1021/acsnano.9b05168 · DOI
- Tomson, 2017, Current and Emerging Uses of Insertable Cardiac Monitors: Evaluation of Syncope and Monitoring for Atrial Fibrillation, Cardiol. Rev., 25, 22, 10.1097/CRD.0000000000000129 · DOI
- Williams, I., Rapeaux, A., Pearson, J., Nazarpour, K., Brunton, E., Luan, S., Liu, Y., and Constandinou, T.G. (2019, January 17–19). SenseBack–Implant considerations for an implantable neural stimulation and recording device. Proceedings of the 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS), Nara, Japan. · DOI
- Laiwalla, F., Lee, J., Lee, A., Mok, E., Leung, V., Shellhammer, S., Song, Y., Larson, L., and Nurmikko, A. (2019, January 23–27). A Distributed Wireless Network of Implantable Sub-mm Cortical Microstimulators for Brain-Computer Interfaces. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany. · DOI
- Kim, 2015, New and Emerging Energy Sources for Implantable Wireless Microdevices, IEEE Access, 3, 89, 10.1109/ACCESS.2015.2406292 · DOI · Paper page
- del Agua, I., Mantione, D., Ismailov, U., Sanchez-Sanchez, A., Aramburu, N., Malliaras, G.G., Mecerreyes, D., and Ismailova, E. (2018). DVS-Crosslinked PEDOT:PSS Free-Standing and Textile Electrodes toward Wearable Health Monitoring. Adv. Mater. Technol., 3. · DOI
- Vizcaya, 2019, Standard ECG lead I prospective estimation study from far-field bipolar leads on the left upper arm: A neural network approach, Biomed. Signal. Process. Control., 51, 171, 10.1016/j.bspc.2019.01.020 · DOI
- Vinciguerra, V., Ambra, E., Maddiona, L., Romeo, M., Mazzillo, M., Rundo, F., Fallica, G., di Pompeo, F., Chiarelli, A.M., and Zappasodi, F. (2018). PPG/ECG Multisite Combo System Based on SiPM Technology. Convegno Nazionale Sensori, Springer. · DOI
- Akter Shathi, M., Minzhi, C., Khoso, N.A., Deb, H., Ahmed, A., and Sai Sai, W. (2020). All organic graphene oxide and Poly (3, 4-ethylene dioxythiophene)-Poly (styrene sulfonate) coated knitted textile fabrics for wearable electrocardiography (ECG) monitoring. Synth. Met., 263. · DOI
- Celik, N., Balachandran, W., Manivannan, N., Winter, E., Schnalzer, B., and Burgsteiner, H. (November, January 29). Wearable mobile ear-based ECG monitoring device using graphene-coated sensors. Proceedings of the 2017 IEEE SENSORS, Glasgow, UK. · DOI
- Wilhelm, 2016, Smart Helmet: Wearable Multichannel ECG and EEG, IEEE J. Transl. Eng. Health Med., 4, 2700111
- Khan, J., Khan, M.U.G., Iqbal, R., and Riaz, O. (2020). Robust Multi-sensor Fusion for the Development of EEG Controlled Vehicle. IEEE Sens. J.
- Gao, K., Shen, G., Zhao, N., Jiang, C., Yang, B., and Liu, J. (2020). Wearable multifunction sensor for the detection of forehead EEG signal and sweat rate on skin simultaneously. IEEE Sens. J. · DOI
- Tang, T., Yan, L., Park, J.H., Wu, H., Zhang, L., Lee, H.Y.B., and Yoo, J. (2020, January 16–20). 34.6 EEG Dust: A BCC-Based Wireless Concurrent Recording/Transmitting Concentric Electrode. Proceedings of the 2020 IEEE International Solid- State Circuits Conference (ISSCC), San Francisco, CA, USA. · doi:10.1109/isscc19947.2020.9063054
- Kim, 2011, Epidermal Electronics, Science, 333, 838, 10.1126/science.1206157 · DOI · Paper page
- Luo, N., Ding, J., Zhao, N., Leung, B.H.K., and Poon, C.C.Y. (2014, January 16–19). Mobile Health: Design of Flexible and Stretchable Electrophysiological Sensors for Wearable Healthcare Systems. Proceedings of the 2014 11th International Conference on Wearable and Implantable Body Sensor Networks, Zurich, Switzerland. · DOI
- Lee, H., Lee, S., Lee, W., Yokota, T., Fukuda, K., and Someya, T. (2019). Ultrathin Organic Electrochemical Transistor with Nonvolatile and Thin Gel Electrolyte for Long-Term Electrophysiological Monitoring. Adv. Funct. Mater., 29. · DOI
- Koo, 2017, Wearable Electrocardiogram Monitor Using Carbon Nanotube Electronics and Color-Tunable Organic Light-Emitting Diodes, ACS Nano, 11, 10032, 10.1021/acsnano.7b04292 · DOI · Paper page
- Someya, T., Yokota, T., Lee, S., and Fukuda, K. (2020, January 18–22). Electronic Skins for Robotics and Wearables. Proceedings of the 2020 IEEE 33rd International Conference on Micro Electro Mechanical Systems (MEMS), Vancouver, BC, Canada. · DOI
- Choi, M., and Kim, S.W. (2017, January 24–27). Driver’s movement monitoring system using capacitive ECG sensors. Proceedings of the 2017 IEEE 6th Global Conference on Consumer Electronics (GCCE), Nagoya, Japan. · doi:10.1109/gcce.2017.8229342
- Seo, M., Choi, M., Lee, J.S., and Kim, S.W. (2018). Adaptive Noise Reduction Algorithm to Improve R Peak Detection in ECG Measured by Capacitive ECG Sensors. Sensors, 18. · DOI
- Nagasato, Y., Izumi, S., Kawaguchi, H., and Yoshimoto, M. (2017, January 19–21). Capacitively coupled ECG sensor system with digitally assisted noise cancellation for wearable application. Proceedings of the 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), Turin, Italy. · doi:10.1109/biocas.2017.8325162
- Pascoli, 2016, Low-Power Wearable ECG Monitoring System for Multiple-Patient Remote Monitoring, IEEE Sens. J., 16, 5452, 10.1109/JSEN.2016.2564995 · DOI · Paper page
- Vavrinsky, E., Subjak, J., Donoval, M., Wagner, A., Zavodnik, T., and Svobodova, H. (2020). Application of Modern Multi-Sensor Holter in Diagnosis and Treatment. Sensors, 20. · DOI
- Tiankui, L. (2017). Perinatal Fetus Real-Time Monitoring and Pregnant Women Health Care Wearable Equipment Design Research. [Master’s Thesis, Southwest Jiaotong University].
- Li, 2015, Development of wearable ECG and PCG acquisition device, Pop. Sci. Technol., 17, 15
- Zhu, 2018, Application and Management of Wearable Devices for Pregnant Women, Med. J. Peking Union Med. Coll. Hosp., 9, 25
- Takei, 2019, Physical and Chemical Sensing With Electronic Skin, IEEE, 107, 2155, 10.1109/JPROC.2019.2907317 · DOI · Paper page
- Xiong, 2019, Cancellation of motion artifacts in ambulatory ECG signals using TD-LMS adaptive filtering techniques, J. Vis. Commun. Image Represent., 58, 606, 10.1016/j.jvcir.2018.12.030 · DOI
- Bashar, S.S., Miah, M.S., Karim, A.Z., Al Mahmud, M.A., and Hasan, Z. (2019, January 7–9). A Machine Learning Approach for Heart Rate Estimation from PPG Signal using Random Forest Regression Algorithm. Proceedings of the 2019 International Conference on Electrical, Computer and Communication Engineering (ECCE), Cox’s Bazar, Bangladesh. · DOI
- Zou, 2017, Motion artifact removal based on periodical property for ECG monitoring with wearable systems, Pervasive Mob. Comput., 40, 267, 10.1016/j.pmcj.2017.06.026 · DOI
- Liu, 2011, A wearable respiratory biofeedback system based on generalized body sensor network, Telemed. J. E-Health Off. J. Am. Telemed. Assoc., 17, 348
- Liu, 2013, Automatic detection of respiratory rate from electrocardiogram, respiration induced plethysmography and 3D acceleration signals, J. Cent. South. Univ., 20, 2423, 10.1007/s11771-013-1752-z · DOI
- Chen, H., Bao, S., Ma, J., Wang, P., Lu, H., Oetomo, S.B., and Chen, W. (2019, January 23–27). A Wearable Daily Respiration Monitoring System Using PDMS-graphene Compound Tensile Sensor for Adult. Proceedings of the 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Berlin, Germany. · doi:10.1109/embc.2019.8857144
- Hung, P.D., Bonnet, S., Guillemaud, R., Castelli, E., and Yen, P.T.N. (2008, January 14–17). Estimation of respiratory waveform using an accelerometer. Proceedings of the 2008 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, Paris, France. · DOI · Paper page
- Bates, A., Ling, M.J., Mann, J., and Arvind, D.K. (2010, January 7–9). Respiratory Rate and Flow Waveform Estimation from Tri-axial Accelerometer Data. Proceedings of the 2010 International Conference on Body Sensor Networks, Singapore. · DOI · Paper page
- Vertens, J., Fischer, F., Heyde, C., Höflinger, F., Zhang, R., Reindl, L., and Gollhofer, A. (2015, January 15–17). Measuring Respiration and Heart Rate Using Two Acceleration Sensors on a Fully Embedded Platform. Proceedings of the 3rd International Congress on Sport Sciences Research and Technology Support (icSPORTS 2015), Lisbon, Portugal. · DOI
- Mack, 2009, Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System, IEEE Trans. Inf. Technol. Biomed., 13, 111, 10.1109/TITB.2008.2007194 · DOI · Paper page
- Zhang, Z., Wang, W., Wang, B., Wu, H., Liu, H., and Zhang, Y. (2009, January 11–13). A Prototype of Wearable Respiration Biofeedback Platform and Its Preliminary Evaluation on Cardiovascular Variability. Proceedings of the 2009 3rd International Conference on Bioinformatics and Biomedical Engineering, Beijing, China. · DOI
- Chen, 2016, Biocompatible and Ultra-Flexible Inorganic Strain Sensors Attached to Skin for Long-Term Vital Signs Monitoring, IEEE Electron. Device Lett., 37, 496, 10.1109/LED.2016.2536036 · DOI
- Yamamoto, 2019, Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise, Med. Biol. Eng. Comput., 57, 2741, 10.1007/s11517-019-02062-2 · DOI
- Kawamura, M., Ishizawa, H., Sato, S., and Koyama, S. (2011, January 13–18). Application to vital signs by Fiber Bragg Grating sensing. Proceedings of the SICE Annual Conference 2011, Tokyo, Japan.
- Dziuda, 2013, Fiber Bragg Grating Strain Sensor Incorporated to Monitor Patient Vital Signs During MRI, IEEE Sens. J., 13, 4986, 10.1109/JSEN.2013.2279160 · DOI · Paper page
- Fajkus, 2019, MR Fully Compatible and Safe FBG Breathing Sensor: A Practical Solution for Respiratory Triggering, IEEE Access, 7, 123013, 10.1109/ACCESS.2019.2937624 · DOI
- Gu, 2019, Mini Review on Flexible and Wearable Electronics for Monitoring Human Health Information, Nanoscale Res. Lett., 14, 263, 10.1186/s11671-019-3084-x · DOI · Paper page
- Kedambaimoole, V., Neella, N., Gaddam, V., Rajanna, K., and Nayak, M.M. (2017, January 9–12). Graphene-Nickel composite films on flexible PCB for temperature monitoring. Proceedings of the 2017 IEEE 12th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), Los Angeles, CA, USA. · DOI
- Khan, 2016, Flexible Hybrid Electronics: Direct Interfacing of Soft and Hard Electronics for Wearable Health Monitoring, Adv. Funct. Mater., 26, 8764, 10.1002/adfm.201603763 · DOI · Paper page
- Giuliani, 2014, A new polystyrene-based ionomer/MWCNT nanocomposite for wearable skin temperature sensors, React. Funct. Polym., 76, 57, 10.1016/j.reactfunctpolym.2014.01.008 · DOI · Paper page
- Wang, 2020, Flexible wearable graphene/alginate composite non-woven fabric temperature sensor with high sensitivity and anti-interference, Cellulose, 27, 2369, 10.1007/s10570-019-02951-7 · DOI
- Ali, S., Bae, J., and Bermak, A. (2019, January 8–10). A flexible differential temperature sensor for wearable electronics applications. Proceedings of the 2019 IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS), Glasgow, UK. · doi:10.1109/fleps.2019.8792276
- Bonzi, 2016, Accuracy of Peripheral Thermometers for Estimating Temperature, Ann. Intern. Med., 165, 73, 10.7326/L16-0070 · DOI
- Atallah, L., Ciuhu, C., Wang, C., Bongers, E., Blom, T., Paulussen, I., and Noordergraaf, G. (2018, January 4–7). An ergonomic wearable core body temperature sensor. Proceedings of the 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN), Las Vegas, NV, USA. · DOI
- Lee, 2019, Flexible Thermoelectric Module Using Bi-Te and Sb-Te Thin Films for Temperature Sensors, J. Electron. Mater., 48, 5464, 10.1007/s11664-019-07235-1 · DOI
- Yang, 2012, Nanowire-composite based flexible thermoelectric nanogenerators and self-powered temperature sensors, Nano Res., 5, 888, 10.1007/s12274-012-0272-8 · DOI · Paper page
- Nakamura, T., Yokota, T., Terakawa, Y., Reeder, J., Voit, W., Someya, T., and Sekino, M. (2016, January 24–27). Development of flexible and wide-range polymer-based temperature sensor for human bodies. Proceedings of the 2016 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI), Las Vegas, NV, USA. · DOI
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Metadata
- Authors
- Liu, J., Liu, M., Bai, Y., Zhang, J., Liu, H., & Zhu, W.
- Affiliations
- College of Information Science and Engineering, Northeastern University, Shenyang 110819, China
- ORCID
- Liu, Jihong
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-07-19
- Volume
- 20
- Issue
- 14
- Pages
- 4009
- ISSN
- 1424-8220
- Cited by
- 104
- References
- 13
- Language
- en
- Funders
- National Training Program of Innovation and Entrepreneurship for Undergraduates,China (201910145160)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.