Recent Advances in Seismocardiography
Open accessAbstract
Cardiovascular disease is a major cause of death worldwide. New diagnostic tools are needed to provide early detection and intervention to reduce mortality and increase both the duration and quality of life for patients with heart disease. Seismocardiography (SCG) is a technique for noninvasive evaluation of cardiac activity. However, the complexity of SCG signals introduced challenges in SCG studies. Renewed interest in investigating the utility of SCG accelerated in recent years and benefited from new advances in low-cost lightweight sensors, and signal processing and machine learning methods. Recent studies demonstrated the potential clinical utility of SCG signals for the detection and monitoring of certain cardiovascular conditions. While some studies focused on investigating the genesis of SCG signals and their clinical applications, others focused on developing proper signal processing algorithms for noise reduction, and SCG signal feature extraction and classification. This paper reviews the recent advances in the field of SCG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Tarver, T. (2014) · Journal of Consumer Health On the Internet · doi:10.1080/15398285.2014.902284 · Cited by 5,605
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
Starr, I., Rawson, A. J., Schroeder, H. A., & Joseph, N. R. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.1.1 · Cited by 398
Sengupta, P. P., Krishnamoorthy, V. K., Korinek, J., Narula, J., Vannan, M. A., Lester, S. J., Tajik, J. A., Seward, J. B., Khandheria, B. K., & Belohlavek, M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.10.013 · Cited by 323
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Inan, O. T., Baran Pouyan, M., Javaid, A. Q., Dowling, S., Etemadi, M., Dorier, A., Heller, J. A., Bicen, A. O., Roy, S., De Marco, T., et al. (2018) · Circulation: Heart Failure · doi:10.1161/circheartfailure.117.004313 · Cited by 207
Mack, D. C., Patrie, J. T., Suratt, P. M., Felder, R. A., & Alwan, M. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2007194 · Cited by 195
Relationship between Seismocardiogram and Echocardiogram for Events in the Cardiac Cycle
Crow, R. S., Hannan, P., Jacobs, D., Hedquist, L., & Salerno, D. M. (2017) · American Journal of Noninvasive Cardiology · doi:10.1159/000470156 · Cited by 186 · cited 1×
“The characteristics of these signals are likely to contain useful information that correlate with cardiovascular physiologic [14] and pathologic processes [15].”
BackgroundJafari Tadi, M., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 174
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163
Castiglioni, P., Faini, A., Parati, G., & Rienzo, M. D. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353199 · Cited by 156
Atrial Fibrillation Detection via Accelerometer and Gyroscope of a Smartphone
Lahdenoja, O., Pänkäälä, M., Koivisto, T., Hurnanen, T., Iftikhar, Z., Nieminen, S., Knuutila, T., Saraste, A., Kiviniemi, T., Vasankari, T., et al. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2688473 · Cited by 155
Seismocardiography: Past, present and future
Zanetti, J. M., & Tavakolian, K. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611170 · Cited by 152
Seismocardiography for Monitoring Changes in Left Ventricular Function during Ischemia
Salerno, D. M., & Zanetti, J. (1991) · Chest · doi:10.1378/chest.100.4.991 · Cited by 149
Timing of aortic valve surgery
Otto, C. M. (2000) · Heart · doi:10.1136/heart.84.2.211 · Cited by 133
Salerno, D. M., & Zanetti, J. M. (1990) · Cited by 127
SeismoWatch: Wearable Cuffless Blood Pressure Monitoring Using Pulse Transit Time
Carek, A. M., Conant, J., Joshi, A. N., Kang, H., & Inan, O. T. (2017) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3130905 · Cited by 119
Optical Vibrocardiography: A Novel Tool for the Optical Monitoring of Cardiac Activity
Morbiducci, U., Scalise, L., Melis, M. D., & Grigioni, M. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9202-9 · Cited by 115
Pandia, K., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/10/1643 · Cited by 114
A real-time approach for heart rate monitoring using a Hilbert transform in seismocardiograms
Tadi, M. J., Lehtonen, E., Hurnanen, T., Koskinen, J., Eriksson, J., Pänkäälä, M., Teräs, M., & Koivisto, T. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/11/1885 · Cited by 111
Time-Frequency Distribution of Seismocardiographic Signals: A Comparative Study
Taebi, A., & Mansy, H. A. (2017) · Bioengineering · doi:10.3390/bioengineering4020032 · Cited by 96
Self-citationInan, O. T., Etemadi, M., Paloma, A., Giovangrandi, L., & Kovacs, G. T. A. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/3/003 · Cited by 94
Automated Detection of Atrial Fibrillation Based on Time–Frequency Analysis of Seismocardiograms
Hurnanen, T., Lehtonen, E., Tadi, M. J., Kuusela, T., Kiviniemi, T., Saraste, A., Vasankari, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2621887 · Cited by 94
Javaid, A. Q., Ashouri, H., Dorier, A., Etemadi, M., Heller, J. A., Roy, S., & Inan, O. T. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2600945 · Cited by 90
Starr, I., & Wood, F. C. (1961) · Circulation · doi:10.1161/01.cir.23.5.714 · Cited by 87
Khosrow-Khavar, F., Tavakolian, K., Blaber, A. P., & Menon, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2616382 · Cited by 82
Wearable ballistocardiogram and seismocardiogram systems for health and performance
Etemadi, M., & Inan, O. T. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00298.2017 · Cited by 82
A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
Sahoo, P., Thakkar, H., & Lee, M.-Y. (2017) · Sensors · doi:10.3390/s17040711 · Cited by 81
Sahoo, P. K., Thakkar, H. K., Lin, W., Chang, P., & Lee, M. (2018) · Sensors · doi:10.3390/s18020379 · Cited by 79
Motion artifact cancellation to obtain heart sounds from a single chest-worn accelerometer
Pandia, K., Ravindran, S., Cole, R., Kovacs, G. T. A., & Giovangrandi, L. (2010) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2010.5495553 · Cited by 70
Automatic Identification of Systolic Time Intervals in Seismocardiogram
Shafiq, G., Tatinati, S., Ang, W. T., & Veluvolu, K. C. (2016) · Scientific Reports · doi:10.1038/srep37524 · Cited by 69
Yang, C., & Tavassolian, N. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2764798 · Cited by 69
Automatic Detection of Aortic Valve Opening Using Seismocardiography in Healthy Individuals
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2829608 · Cited by 69
Salerno, D. M., Zanetti, J. M., Green, L. A., Mooney, M. R., Madison, J. D., & Tassel, R. A. V. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90744-6 · Cited by 68
Yang, C., & Tavassolian, N. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2696703 · Cited by 63
Lin, W.-Y., Tsai, T.-H., Lee, M.-Y., Chou, W.-C., Chang, P.-C., Chou, C.-C., Wen, M.-S., Ho, M.-Y., Lee, W.-C., Hsieh, M.-J., et al. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2620496 · Cited by 62
Seismocardiography: waveform identification and noise analysis
Zanetti, J. M., Poliac, M. O., & Crow, R. S. (2002) · Computers in cardiology · doi:10.1109/cic.1991.169042 · Cited by 62
Analyzing Seismocardiogram Cycles to Identify the Respiratory Phases
Zakeri, V., Akhbardeh, A., Alamdari, N., Fazel-Rezai, R., Paukkunen, M., & Tavakolian, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2621037 · Cited by 62
THE DURATION OF THE SYSTOLE OF THE LEFT VENTRICLE OF MAN
Lombard, W. P., & Cope, O. M. (1926) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1926.77.2.263 · Cited by 61
Improvement of ballistocardiogram processing by inclusion of respiration information
Tavakolian, K., Vaseghi, A., & Kamińska, B. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/7/006 · Cited by 58
Utilizing Gyroscopes Towards the Automatic Annotation of Seismocardiograms
Yang, C., Tang, S., & Tavassolian, N. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2663420 · Cited by 53
Multiclass Classifier based Cardiovascular Condition Detection Using Smartphone Mechanocardiography
Iftikhar, Z., Lahdenoja, O., Tadi, M. J., Hurnanen, T., Vasankari, T., Kiviniemi, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-27683-9 · Cited by 51
Non-Contact Sensing of Seismocardiogram Signals Using Microwave Doppler Radar
Xia, Z., Shandhi, M. M. H., Inan, O. T., & Zhang, Y. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2842122 · Cited by 50
A Hidden Markov Model for Seismocardiography
Wahlström, J., Skog, I., Händel, P., Khosrow-Khavar, F., Tavakolian, K., Stein, P. K., & Nehorai, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2648741 · Cited by 49
Mechanisms Underlying Isovolumic Contraction and Ejection Peaks in Seismocardiogram Morphology.
Gurev, V. (2011) · Journal of Medical and Biological Engineering · doi:10.5405/jmbe.847 · Cited by 47
Ashouri, H., & Inan, O. T. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2701349 · Cited by 47
Monitoring of respiration, seismocardiogram and heart sounds by a PVDF piezo film sensor
Bifulco, P., Gargiulo, G. D., D’Angelo, G., Liccardo, A., Romano, M., Clemente, F., & Cesarelli, M. (2014) · Cited by 46
Grouping similar seismocardiographic signals using respiratory information
Taebi, A., & Mansy, H. A. (2017) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2017.8257053 · Cited by 46
Self-citationMotion Artifact Cancellation of Seismocardiographic Recording From Moving Subjects
Yang, C., & Tavassolian, N. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2573269 · Cited by 43
Lee, H., Lee, H., & Whang, M. (2018) · Sensors · doi:10.3390/s18010238 · Cited by 42
Matsui, T., Hagisawa, K., Ishizuka, T., Takase, B., Ishihara, M., & Kikuchi, M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834250 · Cited by 41
An Independent Component Analysis Approach to Motion Noise Cancelation of Cardio-Mechanical Signals
Yang, C., & Tavassolian, N. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2856700 · Cited by 41
Rienzo, M. D., Vaini, E., & Lombardi, P. (2017) · Scientific Reports · doi:10.1038/s41598-017-15829-0 · Cited by 40
Beat-to-beat heart rate detection by smartphone's accelerometers: Validation with ECG
Landreani, F., Martín-Yebra, A., Casellato, C., Frigo, C., Pavan, E. E., Migeotte, P., & Caiani, E. G. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7590755 · Cited by 39
Heart Sound Extraction From Sternal Seismocardiographic Signal
Choudhary, T., Sharma, L. N., & Bhuyan, M. K. (2018) · IEEE Signal Processing Letters · doi:10.1109/lsp.2018.2801341 · Cited by 38
Ashouri, H., Hersek, S., & Inan, O. T. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2787628 · Cited by 36
Cardiorespiratory system monitoring using a developed acoustic sensor
Abbasi‐Kesbi, R., Valipour, A., & Imani, K. (2017) · Healthcare Technology Letters · doi:10.1049/htl.2017.0012 · Cited by 35
Rienzo, M. D., Vaini, E., Castiglioni, P., Meriggi, P., & Rizzo, F. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611173 · Cited by 33
Migeotte, P., Mucci, V., Delière, Q., Lejeune, L., & van de Borne, P. (2016) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-32703-7_220 · Cited by 33
Automatic annotation of peaks in seismocardiogram for systolic time intervals
Shafiq, G., Tatinati, S., & Veluvolu, K. C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591280 · Cited by 32
Paukkunen, M., Parkkila, P., Hurnanen, T., Pänkäälä, M., Koivisto, T., Nieminen, T. V. M., Kettunen, R., & SEPPONEN, R. E. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2391437 · Cited by 31
Performance analysis of seismocardiography for heart sound signal recording in noisy scenarios
Jain, P. K., Tiwari, A. K., & Chourasia, V. S. (2016) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2016.1139203 · Cited by 29
Precordial acceleration signals improve the performance of diastolic timed vibrations
Tavakolian, K., Khosrow-Khavar, F., Kajbafzadeh, B., Marzencki, M., Blaber, A. P., Kamińska, B., & Menon, C. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.12.001 · Cited by 28
Airborne ultrasound surface motion camera: Application to seismocardiography
Shirkovskiy, P., Laurin, A., Jeger‐Madiot, N., Chapelle, D., Fink, M., & Ing, R. K. (2018) · Applied Physics Letters · doi:10.1063/1.5028348 · Cited by 27
Taebi, A., & Mansy, H. A. (2017) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2017.8257022 · Cited by 26
Self-citationTadi, M. J., Koivisto, T., Pänkäälä, M., Paasio, A., Knuutila, T., Teräs, M., & Hanninen, P. E. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2179346 · Cited by 23
Systolic and diastolic cardiac function time intervals and exercise capacity in women
Libonati, J. R., Colby, A. M., Caldwell, T. M., KASPARIAN, R., & GLASSBERG, H. L. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199902000-00009 · Cited by 22
Yao, J., Tridandapani, S., Wick, C. A., & Bhatti, P. T. (2017) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2017.2708100 · Cited by 22
Chuo, Y., Tavakolian, K., & Kamińska, B. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9380-8 · Cited by 20
A morphological approach to detect respiratory phases of seismocardiogram
Alamdari, N., Tavakolian, K., Zakeri, V., Fazel-Rezai, R., & Akhbardeh, A. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591671 · Cited by 20
An Adaptive Feature Extraction Algorithm for Classification of Seismocardiographic Signals
Taebi, A., Solar, B. E., & Mansy, H. A. (2018) · IEEE SoutheastCon · doi:10.1109/secon.2018.8478958 · Cited by 18
Self-citationAssessment of Mechanical Cardiac Function in Elite Athletes
Neary, J. P. (2011) · The Open Sports Medicine Journal · doi:10.2174/1874387001105010026 · Cited by 16
Motion noise cancellation in seismocardiogram of ambulant subjects with dual sensors
Yang, C., & Tavassolian, N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592066 · Cited by 16
Heart Rate Monitoring During Different Lung Volume Phases Using Seismocardiography
Taebi, A., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2018) · IEEE SoutheastCon · doi:10.1109/secon.2018.8479288 · Cited by 16
Self-citationMotion noise cancellation in seismocardiographic monitoring of moving subjects
Yang, C., & Tavassolian, N. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348361 · Cited by 15
Zhang, G., Cottrell, A. C., Henry, I., & McCombie, D. B. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591454 · Cited by 15
Annotation of seismocardiogram using gyroscopic recordings
Yang, C., Tang, S., & Tavassolian, N. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833767 · Cited by 15
A novel method for suppression of motion artifacts from the seismocardiogram signal
Jain, P. K., & Tiwari, A. K. (2016) · IEEE International Conference on Digital Signal Processing (DSP) · doi:10.1109/icdsp.2016.7868504 · Cited by 15
Robust Detection of AO and IM Points in the Seismocardiogram Using CWT
Rivero-Pouymiró, I., Valdés, E., & Valdés-Pérez, F. E. (2016) · IEEE Latin America Transactions · doi:10.1109/tla.2016.7795816 · Cited by 14
Heart Rate assessment by means of a novel approach applied to signals of different nature
Cosoli, G., Casacanditella, L., Tomasini, E. P., & Scalise, L. (2017) · Journal of Physics Conference Series · doi:10.1088/1742-6596/778/1/012001 · Cited by 13
Korzeniowska‐Kubacka, I., Kuśmierczyk‐Droszcz, B., Bilińska, M., Dobraszkiewicz-Wasilewska, B., Mazurek, K., & Piotrowicz, R. (2006) · Via Medica Journals · Cited by 12
Seismocardiographic adjustment of diastolic timed vibrations
Tavakolian, K., Khosrow-Khavar, F., Kajbafzadeh, B., Marzencki, M., Rohani, S., Kamińska, B., & Menon, C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346794 · Cited by 12
Rienzo, M. D., Lombardi, P., Scurati, D., & Vaini, E. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.225-115 · Cited by 11
Javaid, A. Q., Dowling, S., Etemadi, M., Heller, J. A., Roy, S., Klein, L., & Inan, O. T. (2016) · Computing in cardiology · doi:10.22489/cinc.2016.224-428 · Cited by 11
Determining Heart Rate Beat-to-Beat from Smartphone Seismocardiograms: Preliminary Studies
Sieciński, S., & Kostka, P. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-70063-2_15 · Cited by 11
Identification of respiratory phases using seismocardiogram: A machine learning approach
Zakeri, V., & Tavakolian, K. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7408647 · Cited by 10
Pulse transit time measurement using seismocardiogram and in-ear acoustic sensor
Yang, C., & Tavassolian, N. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833763 · Cited by 10
Casacanditella, L., Cosoli, G., Casaccia, S., Tomasini, E. P., & Scalise, L. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591499 · Cited by 9
An adaptive approach for heartbeat detection based on S-transform in seismocardiograms
Tadi, M. J., Lehtonen, E., Lahdenoja, O., Pänkäälä, M., & Koivisto, T. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591206 · Cited by 9
Sundar, A., & Pahwa, V. (2016) · Advances in intelligent systems and computing · doi:10.1007/978-981-10-2035-3_5 · Cited by 8
Metzler, J., Kroschel, K., & Willersinn, D. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2253654 · Cited by 8
Signal Processing Methods for Heart Rate Detection Using the Seismocardiogram
Mafi, M. (2016) · University Library - University of Saskatchewan (University of Saskatchewan) · Cited by 8
Malcangi, M., Quan, H., Vaini, E., Lombardi, P., & Rienzo, M. D. (2018) · Evolving Systems · doi:10.1007/s12530-018-9238-8 · Cited by 8
Malcangi, M., Quan, H., Vaini, E., Lombardi, P., & Rienzo, M. D. (2017) · Communications in computer and information science · doi:10.1007/978-3-319-65172-9_22 · Cited by 5
An accelerometer based system to measure myocardial performance index during stress testing
Dinh, A., Bui, F. M., & Nguyen, T. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591820 · Cited by 3
Casacanditella, L., Cosoli, G., Casaccia, S., Rohrbaugh, J., Scalise, L., & Tomasini, E. P. (2016) · AIP conference proceedings · doi:10.1063/1.4952670 · Cited by 2
Pouyan, M. B., Dowling, S., Marco, T. D., Klein, L., & Inan, O. T. (2017) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2017.07.369 · Cited by 2
Using multiple placements of accelerometers to measure cardiovascular pulse transit times
Canino, N. K., Wang, R. R., & Robinson, C. J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591665 · Cited by 1
Cited by
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R. (2020) · Sensors · doi:10.3390/s20072033 · Cited by 75
A Unified Framework for Quality Indexing and Classification of Seismocardiogram Signals
Zia, J., Kimball, J., Hersek, S., Shandhi, M. M. H., Semiz, B., & Inan, O. T. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2931348 · Cited by 48
“Furthermore, the patient-specific nature of SCG due to physiological variability has made it difficult to identify a prototypical waveform [7].”
BackgroundNon-Invasive Wearable Patch Utilizing Seismocardiography for Peri-Operative Use in Surgical Patients
Semiz, B., Carek, A. M., Johnson, J. C., Ahmad, S., Heller, J. A., Vicente, F. G., Caron, S., Hogue, C. W., Etemadi, M., & Inan, O. T. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3032938 · Cited by 35
Metadata
- Authors
- Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A.
- Venue
- Vibration
- Publisher
- MDPI AG
- Published
- 2019-01-14
- Volume
- 2
- Issue
- 1
- Pages
- 64-86
- ISSN
- 2571-631X (ISSN-L)
- OpenAlex
- W2910678199
- Cited by
- 276
- References
- 102
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.