Respiratory rate: the neglected vital sign
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The level of documentation of vital signs in many hospitals is extremely poor, and respiratory rate, in particular, is often not recorded. There is substantial evidence that an abnormal respiratory rate is a predictor of potentially serious clinical events. Nurses and doctors need to be more aware of the importance of an abnormal respiratory rate as a marker of serious illness. Hospital systems that encourage appropriate responses to an elevated respiratory rate and other abnormal vital signs can be rapidly implemented. Such systems help to raise and sustain awareness of the importance of vital signs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction of the medical emergency team (MET) system: a cluster-randomised controlled trial
(2005) · The Lancet · doi:10.1016/s0140-6736(05)66733-5 · Cited by 1,301
Respiratory physiology: The essentials
(1975) · British Journal of Diseases of the Chest · doi:10.1016/0007-0971(75)90100-x · Cited by 1,120
Clinical Antecedents to In-Hospital Cardiopulmonary Arrest
Schein, R. M. H., Hazday, N., Pena, M., Ruben, B. H., & Sprung, C. L. (1990) · Chest · doi:10.1378/chest.98.6.1388 · Cited by 905
Respiratory Physiology: The Essentials
Jones, S. L. (1975) · Physical Therapy · doi:10.1093/ptj/55.5.563a · Cited by 455
Subbe, C. P., Davies, R. G., Williams, E., Rutherford, P., & Gemmell, L. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03258.x · Cited by 446
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Respiratory rate predicts cardiopulmonary arrest for internal medicine inpatients.
Fieselmann, J. F., Hendryx, M. S., Helms, C. M., & Wakefield, D. S. (1993) · Journal of General Internal Medicine · doi:10.1007/bf02600071 · Cited by 399
Hodgetts, T. J., Kenward, G., Vlachonikolis, I. G., Payne, S., & Castle, N. (2002) · Resuscitation · doi:10.1016/s0300-9572(02)00100-4 · Cited by 355
Physiological abnormalities in early warning scores are related to mortality in adult inpatients †
Goldhill, D. R., & McNarry, A. F. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh113 · Cited by 325
Goldhill, D. R., McNarry, A. F., Mandersloot, G., & McGinley, A. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2005.04186.x · Cited by 304
Cited by
Internet of Things for Smart Healthcare: Technologies, Challenges, and Opportunities
Baker, S. B., Xiang, W., & Atkinson, I. (2017) · IEEE Access · doi:10.1109/access.2017.2775180 · Cited by 1,130
Jones, D. A., DeVita, M. A., & Bellomo, R. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0910926 · Cited by 791
Self-citationLee, Y., Park, J., Cho, S., Shin, Y.-E., Lee, H., Kim, J., Myoung, J., Cho, S., Kang, S., Baig, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b01805 · Cited by 528
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise
Nicolò, A., Massaroni, C., Schena, E., & Sacchetti, M. (2020) · Sensors · doi:10.3390/s20216396 · Cited by 440
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Non-contact video-based vital sign monitoring using ambient light and auto-regressive models
Tarassenko, L., Villarroel, M., Guazzi, A., Jorge, J., Clifton, D. A., & Pugh, C. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/5/807 · Cited by 423
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Brekke, I. J., Puntervoll, L. H., Pedersen, P. B., Kellett, J., & Brabrand, M. (2019) · PLOS ONE · doi:10.1371/journal.pone.0210875 · Cited by 312
Defining clinical deterioration
Jones, D., Mitchell, I., Hillman, K., & Story, D. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2013.01.013 · Cited by 276
Self-citationNasal high flow reduces dead space
Möller, W., Feng, S., Domanski, U., Franke, K.-J., Celik, G., Bartenstein, P., Becker, S., Meyer, G., Schmid, O., Eickelberg, O., et al. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00584.2016 · Cited by 266
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
The formula for survival in resuscitation
Søreide, E., Morrison, L., Hillman, K., Monsieurs, K., Sunde, K., Zideman, D., Eisenberg, M., Sterz, F., Nadkarni, V. M., Soar, J., et al. (2013) · Resuscitation · doi:10.1016/j.resuscitation.2013.07.020 · Cited by 254
Self-citationLudikhuize, J., Smorenburg, S. M., de Rooij, S. E., & de Jonge, E. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2012.01.003 · Cited by 250
Wearable technology: role in respiratory health and disease
Aliverti, A. (2017) · Breathe · doi:10.1183/20734735.008417 · Cited by 243
Vital Signs in Older Patients: Age-Related Changes
Chester, J. G., & Rudolph, J. L. (2011) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2010.04.009 · Cited by 238
Bellomo, R., Ackerman, M., Bailey, M., Beale, R., Clancy, G., Danesh, V., Hvarfner, A., Jimenez, E., Konrad, D., Lecardo, M., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318255d9a0 · Cited by 228
Self-citationZeng, X., Wang, Z., Zhang, H., Yang, W., Xiang, L., Zhao, Z., Peng, L.-M., & Hu, Y. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02518 · Cited by 214
Continuous Monitoring in an Inpatient Medical-Surgical Unit: A Controlled Clinical Trial
Brown, H., Terrence, J., Vasquez, P., Bates, D. W., & Zimlichman, E. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.12.004 · Cited by 211
Peng, X., Dong, K., Ning, C., Cheng, R., Yi, J., Zhang, Y., Sheng, F., Wu, Z., & Wang, Z. L. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202103559 · Cited by 210
Respiratory Frequency during Exercise: The Neglected Physiological Measure
Nicolò, A., Massaroni, C., & Passfield, L. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00922 · Cited by 208
Lenglet, H., Sztrymf, B., Leroy, C., Brun, P., Dreyfuss, D., & Ricard, J.-D. (2012) · Respiratory Care · doi:10.4187/respcare.01575 · Cited by 201
Derivation of a cardiac arrest prediction model using ward vital signs*
Churpek, M. M., Yuen, T. C., Park, S. Y., Meltzer, D. O., Hall, J. B., & Edelson, D. P. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318250aa5a · Cited by 199
Weft-Knitted Strain Sensor for Monitoring Respiratory Rate and Its Electro-Mechanical Modeling
Atalay, O., Kennon, W. R., & Demirok, E. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2339739 · Cited by 198
Beasley, R., Chien, J., Douglas, J., Eastlake, L., Farah, C., King, G., Moore, R., Pilcher, J., Richards, M., Smith, S., et al. (2015) · Respirology · doi:10.1111/resp.12620 · Cited by 195
Brink, A., Alsma, J., Verdonschot, R. J. C. G., Rood, P. P. M., Zietse, R., Lingsma, H. F., & Schuit, S. C. E. (2019) · PLOS ONE · doi:10.1371/journal.pone.0211133 · Cited by 186
Predicting Cardiac Arrest on the Wards
Churpek, M. M., Yuen, T. C., Huber, M. T., Park, S. Y., Hall, J. B., & Edelson, D. P. (2012) · Chest · doi:10.1378/chest.11-1301 · Cited by 185
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Documenting Rapid Response System afferent limb failure and associated patient outcomes
Trinkle, R. M., & Flabouris, A. (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.03.019 · Cited by 182
Self-citationC-FMCW Based Contactless Respiration Detection Using Acoustic Signal
Wang, T., Zhang, D., Zheng, Y., Gu, T., Zhou, X., & Dorizzi, B. (2018) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3161188 · Cited by 180
Contactless Methods For Measuring Respiratory Rate: A Review
Massaroni, C., Nicolo, A., Sacchetti, M., & Schena, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3023486 · Cited by 180
Improving detection of patient deterioration in the general hospital ward environment
Vincent, J.-L., Einav, S., Pearse, R., Jaber, S., Kranke, P., Overdyk, F. J., Whitaker, D. K., Gordo, F., Dahan, A., & Hoeft, A. (2018) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000798 · Cited by 174
Remote monitoring of breathing dynamics using infrared thermography
Pereira, C. B., Yu, X., Czaplik, M., Rossaint, R., Blazek, V., & Leonhardt, S. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.004378 · Cited by 163
A flexible humidity sensor based on silk fabrics for human respiration monitoring
Li, B., Xiao, G., Liu, F., Qiao, Y., Li, C. M., & Lu, Z. (2018) · Journal of Materials Chemistry C · doi:10.1039/c8tc00238j · Cited by 161
Birrenkott, D. A., Pimentel, M. A. F., Watkinson, P. J., & Clifton, D. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2778265 · Cited by 71
Data omission by physician trainees on ICU rounds.
Artis, K. A., Bordley, J., Mohan, V., & Gold, J. A. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003557 · Cited by 36
Metadata
- Authors
- Cretikos, M. A., Bellomo, R., Hillman, K., Chen, J., Finfer, S., & Flabouris, A.
- Venue
- Medical Journal of Australia
- Publisher
- AMPCo
- Published
- 2008-06
- Volume
- 188
- Issue
- 11
- Pages
- 657-659
- ISSN
- 0025-729X (ISSN-L)
- 1326-5377
- OpenAlex
- W2097721391
- Cited by
- 889
- References
- 21
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.