Near-infrared fluorescence imaging in the largely unexplored window of 900-1,000 nm
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Near-infrared (NIR) fluorescence imaging has relied on fluorophores that emit in the 700-900 nm NIR-Ia or 1,000-1,700 nm NIR-II window for generating deep-tissue images.Up until now, there have been few fluorophores developed for the 900-1,000 nm NIR-Ib window.This is largely because NIR-Ib light is thought to be strongly absorbed by water.Methods: Here we found that six heptamethine dyes had distinct emission peaks in both the NIR-Ia and NIR-Ib window.We tested the performance of these contrast agents by introducing them into the leaves of the common house plant Epipremnum aureum with early stage anthracnose leaf infections from Khaya senegalensis, as well as injecting them into the hind feet of nude mice and tails of tumour-bearing mice in vivo.Results: Heptamethine dyes yielded superior images of leaf venation, anthracnose infection locations, sentinel lymph nodes, brain tumours and subcutaneous tumours in the NIR-Ib window.We found that NIR-Ib images had markedly enhanced signal-to-background ratio because autofluorescence, scattering and light absorption by biological tissues and water were weaker at longer wavelengths.Conclusion: NIR-Ib fluorescence imaging was a powerful method for studying sentinel lymph nodes, tumours, leaf veins and early anthracnose infection locations in plant leaves.The findings challenge our current view of NIR fluorescence imaging and may have important implications for biomedical research and image-guided cancer surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848 · cited 2×
“Although nowadays there are indium–gallium–arsenide (InGaAs) cameras that can detect photons in the 900–1,700 nm window, these cameras are still a rarity [23, 39].”
BackgroundA small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778 · cited 1×
“Despite these advances, however, little attention has been paid to fluorescence imaging in the 900–1000 nm NIR-Ib window [35, 36].”
BackgroundA route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287 · cited 1×
“However, recent experiments with single-walled carbon nanotubes, quantum dots and small molecules that fluoresce in the 1,000–1,700 nm NIR-II window have highlighted the benefits of imaging at longer wavelengths [20-34], including increased spatial resolution, signal-to-background ratio (SBR) and penetration depth.”
BackgroundMultifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Li, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658 · cited 1×
“However, recent experiments with single-walled carbon nanotubes, quantum dots and small molecules that fluoresce in the 1,000–1,700 nm NIR-II window have highlighted the benefits of imaging at longer wavelengths [20-34], including increased spatial resolution, signal-to-background ratio (SBR) and penetration depth.”
BackgroundA high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623 · cited 1×
“However, recent experiments with single-walled carbon nanotubes, quantum dots and small molecules that fluoresce in the 1,000–1,700 nm NIR-II window have highlighted the benefits of imaging at longer wavelengths [20-34], including increased spatial resolution, signal-to-background ratio (SBR) and penetration depth.”
BackgroundHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563 · cited 1×
“Despite these advances, however, little attention has been paid to fluorescence imaging in the 900–1000 nm NIR-Ib window [35, 36].”
BackgroundDonor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554 · cited 1×
“However, recent experiments with single-walled carbon nanotubes, quantum dots and small molecules that fluoresce in the 1,000–1,700 nm NIR-II window have highlighted the benefits of imaging at longer wavelengths [20-34], including increased spatial resolution, signal-to-background ratio (SBR) and penetration depth.”
BackgroundRational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Yang, Q., Ma, Z., Wang, H., Zhou, B., Zhu, S., Zhong, Y., Wang, J., Wan, H., Antaris, A., Ma, R., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605497 · Cited by 467
Lei, Z., Li, X., Luo, X., He, H., Zheng, J., Qian, X., & Yang, Y. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201612301 · Cited by 177 · cited 1×
“Second, there are few known fluorophores with emission peaks in the NIR-Ib window [38].”
Background
Cited by
Near‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Persistent luminescence instead of phosphorescence: History, mechanism, and perspective
Xu, J., & Tanabe, S. (2019) · Journal of Luminescence · doi:10.1016/j.jlumin.2018.09.047 · Cited by 680
Li, Y., Cai, Z., Liu, S., Zhang, H., Wong, S. T. H., Lam, J. W. Y., Kwok, R. T. K., Qian, J., & Tang, B. Z. (2020) · Nature Communications · doi:10.1038/s41467-020-15095-1 · Cited by 464
Perfecting and extending the near-infrared imaging window
Feng, Z., Tang, T., Wu, T., Yu, X., Zhang, Y., Wang, M., Zheng, J., Ying, Y., Chen, S., Zhou, J., et al. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00628-0 · Cited by 394
Self-citationConstitutional Isomerization Enables Bright NIR‐II AIEgen for Brain‐Inflammation Imaging
Liu, S., Chen, C., Li, Y., Zhang, H., Liu, J., Wang, R., Wong, S. T. H., Lam, J. W. Y., Ding, D., & Tang, B. Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908125 · Cited by 267
Albumin-chaperoned cyanine dye yields superbright NIR-II fluorophore with enhanced pharmacokinetics
Tian, R., Zeng, Q., Zhu, S., Lau, J., Chandra, S., Ertsey, R., Hettie, K. S., Teraphongphom, T., Hu, Z., Niu, G., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw0672 · Cited by 266
Chen, C., Tian, R., Zeng, Y., Chu, C., & Liu, G. (2020) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.9b00734 · Cited by 215
Rational Design of Near-Infrared-II Organic Molecular Dyes for Bioimaging and Biosensing
Li, B., Zhao, M., & Zhang, F. (2020) · ACS Materials Letters · doi:10.1021/acsmaterialslett.0c00157 · Cited by 206
Highly Stable and Bright NIR-II AIE Dots for Intraoperative Identification of Ureter
Du, J., Liu, S., Zhang, P., Liu, H., Li, Y., He, W., Li, C., Chau, J. H. C., Kwok, R. T. K., Lam, J. W. Y., et al. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b22957 · Cited by 70
Self-citationNew strategies on the application of artificial intelligence in the field of phytoremediation
Singh, P., Pani, A., Mujumdar, A. S., & Shirkole, S. S. (2023) · International Journal of Phytoremediation · doi:10.1080/15226514.2022.2090500 · Cited by 41
Metadata
- Authors
- Deng, G., Li, S., Sun, Z., Li, W., Zhou, L., Zhang, J., Gong, P., & Cai, L.
- Venue
- Theranostics
- Publisher
- Ivyspring International Publisher
- Published
- 2018
- Volume
- 8
- Issue
- 15
- Pages
- 4116-4128
- ISSN
- 1838-7640 (ISSN-L)
- OpenAlex
- W2886154438
- Cited by
- 73
- References
- 11
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.