Transdermal Electrochemical Monitoring of Glucose via High‐Density Silicon Microneedle Array Patch
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Current technology for blood glucose level monitoring is mainly based on the invasive finger‐prick extraction of a small drop of blood using a lancet and measured via a handheld glucometer, which is not conducive to continuous measurements. Interstitial fluid (ISF) is gaining attention as an alternative biofluid. Its biochemical composition is very similar to that of blood and it can be monitored in a continuous manner via minimally invasive methods that cause no pain and minimize any risk of infection. Herein, a microneedle array (MNA) based transdermal sensing system for the pain free monitoring of ISF glucose is presented. High‐density silicon microneedles (≈9500 microneedles cm−2) are used to prepare a three‐electrode patch for the electrochemical monitoring of glucose. The MNA glucose patch shows very good selectivity when tested in artificial ISF, with a sensitivity of 0.1622 µ A m m−1 cm−2 and a detection limit of 0.66 m m. In vivo application of the microneedle array in mice shows that the ISF glucose concentrations obtained with the MNA sensor gave very good correlation with the blood glucose levels determined with a commercial glucometer. This microneedle‐based sensing system hence provides an alternative transdermal diagnostic tool to the invasive existing techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Diabetes Mellitus, Fasting Glucose, and Risk of Cause-Specific Death
The Emerging Risk Factors Collaboration (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1008862 · Cited by 2,726
What is the Young's Modulus of Silicon?
Hopcroft, M. A., Nix, W. D., & Kenny, T. W. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039697 · Cited by 2,119
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118
Larrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964
High resolution XPS of organic polymers: the scienta ESCA300 database
Pireaux, J. J. (1993) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(93)85006-7 · Cited by 851
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
The thickness of the epidermis
WHITTON, J. T., & EVERALL, J. D. (1973) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1973.tb03007.x · Cited by 271
Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers
Zhang, X., Chen, G., Bian, F., Cai, L., & Zhao, Y. (2019) · Advanced Materials · doi:10.1002/adma.201902825 · Cited by 252
Microneedles for Transdermal Biosensing: Current Picture and Future Direction
Ventrelli, L., Marsilio Strambini, L., & Barillaro, G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201500450 · Cited by 235
Microneedles for transdermal diagnostics: Recent advances and new horizons
Liu, G.-S., Kong, Y., Wang, Y., Luo, Y., Fan, X., Xie, X., Yang, B.-R., & Wu, M. X. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119740 · Cited by 231
Hong, Y. J., Lee, H., Kim, J., Lee, M., Choi, H. J., Hyeon, T., & Kim, D. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201805754 · Cited by 229
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Self-citationTran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 198
Microneedle-based self-powered glucose sensor
Valdés-Ramírez, G., Li, Y.-C., Kim, J., Jia, W., Bandodkar, A. J., Nuñez-Flores, R., Miller, P. R., Wu, S.-Y., Narayan, R., Windmiller, J. R., et al. (2014) · Electrochemistry Communications · doi:10.1016/j.elecom.2014.07.014 · Cited by 188
Lin, Y., Bariya, M., Nyein, H. Y. Y., Kivimäki, L., Uusitalo, S., Jansson, E., Ji, W., Yuan, Z., Happonen, T., Liedert, C., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201902521 · Cited by 185
Dawes, J. M., Weir, G. A., Middleton, S. J., Patel, R., Chisholm, K. I., Pettingill, P., Peck, L. J., Sheridan, J., Shakir, A., Jacobson, L., et al. (2018) · Neuron · doi:10.1016/j.neuron.2018.01.033 · Cited by 181
GhavamiNejad, A., Li, J., Lu, B., Zhou, L., Lam, L., Giacca, A., & Wu, X. Y. (2019) · Advanced Materials · doi:10.1002/adma.201901051 · Cited by 162
Strambini, L. M., Longo, A., Scarano, S., Prescimone, T., Palchetti, I., Minunni, M., Giannessi, D., & Barillaro, G. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.11.010 · Cited by 154
An overview of dealloyed nanoporous gold in bioelectrochemistry
Xiao, X., Si, P., & Magner, E. (2015) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2015.12.008 · Cited by 139
Bollella, P., Sharma, S., Cass, A. E. G., Tasca, F., & Antiochia, R. (2019) · Catalysts · doi:10.3390/catal9070580 · Cited by 121
Kim, K. B., Lee, W.-C., Cho, C.-H., Park, D., Cho, S. J., & Shim, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.081 · Cited by 112
Microneedle Electrodes Toward an Amperometric Glucose‐Sensing Smart Patch
Invernale, M. A., Tang, B. C., York, R. L., Le, L., Hou, D. Y., & Anderson, D. G. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300142 · Cited by 99
Ranamukhaarachchi, S. A., Padeste, C., Dübner, M., Häfeli, U. O., Stoeber, B., & Cadarso, V. J. (2016) · Scientific Reports · doi:10.1038/srep29075 · Cited by 99
A study of human skin and surface temperatures in stable and unstable thermal environments
Liu, Y., Wang, L., Liu, J., & Di, Y. (2013) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2013.06.006 · Cited by 95
Anatomy, Physiology, Histology, and Immunohistochemistry of Human Skin
Fenner, J., & Clark, R. A. F. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-801654-1.00001-2 · Cited by 90
Holzer, B., Manoli, K., Ditaranto, N., Macchia, E., Tiwari, A., Franco, C. D., Scamarcio, G., Palazzo, G., & Torsi, L. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700055 · Cited by 84
Gold microneedles fabricated by casting of gold ink used for urea sensing
Şenel, M., Dervisevic, M., & Voelcker, N. H. (2019) · Materials Letters · doi:10.1016/j.matlet.2019.02.014 · Cited by 77
Self-citationRelationship between diabetes and respiratory diseases—Clinical and therapeutic aspects
Visca, D., Pignatti, P., Spanevello, A., Lucini, E., & Rocca, E. L. (2018) · Pharmacological Research · doi:10.1016/j.phrs.2018.10.008 · Cited by 68
Koschinsky, T., Jungheim, K., & Heinemann, L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322527030 · Cited by 64
Functionalized microneedles for continuous glucose monitoring
Takeuchi, K., & Kim, B. (2018) · Nano Convergence · doi:10.1186/s40580-018-0161-2 · Cited by 63
Novel reagentless glucose biosensor based on ferrocene cored asymmetric PAMAM dendrimers
Şenel, M., Nergiz, C., & Çevik, E. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.10.072 · Cited by 62
Kucherenko, D. Y., Kucherenko, I. S., Soldatkin, O. O., Topolnikova, Y. V., Dzyadevych, S. V., & Soldatkin, A. P. (2019) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2019.03.010 · Cited by 50
Coffey, J. W., Meliga, S. C., Corrie, S. R., & Kendall, M. A. F. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.015 · Cited by 45
Bhargav, A., Muller, D. A., Kendall, M. A. F., & Corrie, S. R. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am3001727 · Cited by 40
Minimally invasive technique for measuring transdermal glucose with a fluorescent biosensor
Brown, S., Zambrana, P. N., Ge, X., Bagdure, D. N., Stinchcomb, A. L., Rao, G., & Tolosa, L. M. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1336-8 · Cited by 34
Şenel, M., Nergiz, C., Dervisevic, M., & Çevik, E. (2013) · Electroanalysis · doi:10.1002/elan.201200535 · Cited by 33
Self-citationSelf-Assembled Films of Dendrimers and Metallophthalocyanines as FET-Based Glucose Biosensors
Vieira, N. C. S., Figueiredo, A., de Queiroz, Á. A. A., Zucolotto, V., & Guimarães, F. E. G. (2011) · Sensors · doi:10.3390/s111009442 · Cited by 29
Micro‐ and Nanosystems for Advanced Transdermal Delivery
Yan, L., Alba, M., Tabassum, N. H., & Voelcker, N. H. (2019) · Advanced Therapeutics · doi:10.1002/adtp.201900141 · Cited by 24
Self-citation
Cited by
Tehrani, F., Teymourian, H., Wuerstle, B., Kavner, J., Patel, R., Furmidge, A., Aghavali, R., Hosseini-Toudeshki, H., Brown, C., Zhang, F., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00887-1 · Cited by 625
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Vora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
“Forinstance,Dervisevicetal.recentlyproposeda silicon-basedhigh-densitymicroneedlearraythatsuccessfullydetected increasingglucoseinmice,provingthatthedevicecanpenetratethroughthe skinbarriertoassessISF(Fig.5a) 91 .”
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64
Metadata
- Authors
- Dervisevic, M., Alba, M., Yan, L., Senel, M., Gengenbach, T. R., Prieto‐Simon, B., & Voelcker, N. H.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-03-04
- Volume
- 32
- Issue
- 3
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3134121833
- Cited by
- 170
- References
- 44
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.