A Fully Integrated Closed-Loop System Based on Mesoporous Microneedles-Iontophoresis for Diabetes Treatment
Open accessAbstract
A closed-loop system that can mini-invasively track blood glucose and intelligently treat diabetes is in great demand for modern medicine, yet it remains challenging to realize. Microneedles technologies have recently emerged as powerful tools for transdermal applications with inherent painlessness and biosafety. In this work, for the first time to the authors' knowledge, a fully integrated wearable closed-loop system (IWCS) based on mini-invasive microneedle platform is developed for in situ diabetic sensing and treatment. The IWCS consists of three connected modules: 1) a mesoporous microneedle-reverse iontophoretic glucose sensor; 2) a flexible printed circuit board as integrated and control; and 3) a microneedle-iontophoretic insulin delivery component. As the key component, mesoporous microneedles enable the painless penetration of stratum corneum, implementing subcutaneous substance exchange. The coupling with iontophoresis significantly enhances glucose extraction and insulin delivery and enables electrical control. This IWCS is demonstrated to accurately monitor glucose fluctuations, and responsively deliver insulin to regulate hyperglycemia in diabetic rat model. The painless microneedles and wearable design endows this IWCS as a highly promising platform to improve the therapies of diabetic patients.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Li et al. employed mesoporous microneedles patches for both glucose extraction and insulin delivery.
“Li et al. [164] employed mesoporous microneedles patches for both glucose extraction and insulin delivery (Figure 6e).”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [164]
The IWCS platform could regulate blood glucose levels in a diabetic rat.
“This IWCS platform could regulate blood glucose levels in a diabetic rat.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [164]
The fully integrated wearable closed-loop system (IWCS) could accurately track glucose concentration via electrochemical sensors and accordingly deliver insulin.
“This fully integrated wearable closed-loop system (IWCS) could accurately track glucose concentration via electrochemical sensors and accordingly deliver insulin.”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [164]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087 · see citing works
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · see citing works
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802 · see citing works
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · see citing works
Sotagliflozin in patients with diabetes and chronic kidney disease
Bhatt, D. L., Szarek, M., Pitt, B., Cannon, C. P., Leiter, L. A., McGuire, D. K., Lewis, J. B., Riddle, M. C., Inzucchi, S. E., Kosiborod, M. N., et al. (2021) · New England Journal of Medicine · doi:10.1056/nejmoa2030186 · Cited by 1,205 · see citing works
Lee, H., Song, C., Hong, Y. S., Kim, M., Cho, H. R., Kang, T., Shin, K., Choi, S. H., Hyeon, T., & Kim, D.-H. (2017) · Science Advances · doi:10.1126/sciadv.1601314 · Cited by 1,118 · see citing works
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030 · see citing works
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951 · see citing works
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 890 · see citing works
Yu, J., Zhang, Y., Ye, Y., DiSanto, R., Sun, W., Ranson, D., Ligler, F. S., Buse, J. B., & Gu, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505405112 · Cited by 852 · see citing works
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839 · see citing works
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778 · see citing works
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758 · see citing works
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700 · see citing works
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655 · see citing works
Managing diabetes with nanomedicine: challenges and opportunities
Omid Veiseh, A., Tang, B. C., Whitehead, K. A., Anderson, D. G., & Langer, R. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4477 · Cited by 618 · see citing works
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604 · see citing works
Simultaneous Monitoring of Sweat and Interstitial Fluid Using a Single Wearable Biosensor Platform
Kim, J., Sempionatto, J. R., Imani, S., Hartel, M. C., Barfidokht, A., Tang, G., Campbell, A. S., Mercier, P. P., & Wang, J. (2018) · Advanced Science · doi:10.1002/advs.201800880 · Cited by 525 · see citing works
Wireless smart contact lens for diabetic diagnosis and therapy
Keum, D. H., Kim, S.-K., Koo, J., Lee, G.-H., Jeon, C., Mok, J. W., Mun, B. H., Lee, K. J., Kamrani, E., Joo, C.-K., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba3252 · Cited by 483 · see citing works
Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring
Chen, Y., Lu, S., Zhang, S., Li, Y., Qu, Z., Chen, Y., Lu, B., Wang, X., & Feng, X. (2017) · Science Advances · doi:10.1126/sciadv.1701629 · Cited by 470 · see citing works
del Río, J. S., Henry, O., Jolly, P., & Ingber, D. E. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0566-z · Cited by 453 · see citing works
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Echelpoel, R. V., Wael, K. D., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 431 · see citing works
A smartphone dongle for diagnosis of infectious diseases at the point of care
Laksanasopin, T., Guo, T. W., Nayak, S., Sridhara, A. A., Shi, X., Olowookere, O. O., Cadinu, P., Meng, F., Chee, N. H., Kim, J., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa0056 · Cited by 428 · see citing works
Owens, D. R., Zinman, B., & Bolli, G. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05842-1 · Cited by 374 · see citing works
Device-assisted transdermal drug delivery
Lee, H., Song, C., Baik, S., Kim, D., Hyeon, T., & Kim, D.-H. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.08.009 · Cited by 347 · see citing works
Lipani, L., Dupont, B. G. R., Doungmene, F., Marken, F., Tyrrell, R. M., Guy, R. H., & Ilie, A. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0112-4 · Cited by 340 · see citing works
Precise Microinjection into Skin Using Hollow Microneedles
Wang, P. M., Cornwell, M., Hill, J., et al. (2006) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700150 · Cited by 333 · see citing works
Liu, S., Jin, M.-N., Quan, Y., Kamiyama, F., Katsumi, H., Sakane, T., & Yamamoto, A. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.05.030 · Cited by 313 · see citing works
Hu, X., Yu, J., Qian, C., Lü, Y., Kahkoska, A. R., Xie, Z., Jing, X., Buse, J. B., & Gu, Z. (2017) · ACS Nano · doi:10.1021/acsnano.6b06892 · Cited by 313 · see citing works
Core–Shell Microneedle Gel for Self-Regulated Insulin Delivery
Wang, J., Ye, Y., Yu, J., Kahkoska, A. R., Zhang, X., Wang, C., Sun, W., Corder, R. D., Chen, Z., Khan, S. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b08152 · Cited by 299 · see citing works
Glucose monitoring by reverse iontophoresis
Potts, R. O., Tamada, J. A., & Tierney, M. J. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 244 · see citing works
Nimri, R., Battelino, T., Laffel, L. M., Slover, R. H., Schatz, D., Weinzimer, S. A., Dovc, K., Danne, T., Phillip, M., NextDREAM Consortium, et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1045-7 · Cited by 242 · see citing works
Xie, X., Doloff, J. C., Yesilyurt, V., Sadraei, A., McGarrigle, J. J., Omami, M., Veiseh, O., Farah, S., Isa, D., Ghani, S., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0273-3 · Cited by 235 · see citing works
Self-citationChen, H., Zhu, H., Zheng, J., et al. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.031 · Cited by 202 · see citing works
Self-citationThe Lifetime Cost of Diabetes and Its Implications for Diabetes Prevention
Zhuo, X., Zhang, P., Barker, L. E., Albright, A. L., Thompson, T. J., & Gregg, E. W. (2014) · Diabetes Care · doi:10.2337/dc13-2484 · Cited by 201 · see citing works
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A. N., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S. P., Chua, B., Chang, A., & Christiansen, M. P. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 178 · see citing works
Integrated contact lens sensor system based on multifunctional ultrathin MoS2 transistors
Guo, S., Wu, K., Li, C., Wang, H., Sun, Z., Xi, D., Zhang, S., Ding, W., Zaghloul, M. E., Wang, C., et al. (2020) · Matter · doi:10.1016/j.matt.2020.12.002 · Cited by 178 · see citing works
Self-citationArtificial Pancreas Device Systems for the Closed-Loop Control of Type 1 Diabetes
Trevitt, S., Simpson, S., & Wood, A. L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815617968 · Cited by 175 · see citing works
Analgesic Microneedle Patch for Neuropathic Pain Therapy
Xie, X., Pascual, C., Lieu, C. H., et al. (2016) · ACS Nano · doi:10.1021/acsnano.6b06104 · Cited by 166 · see citing works
Self-citationA basal-bolus insulin regimen integrated microneedle patch for intraday postprandial glucose control
Chen, B. Z., Zhang, L. Q., Xia, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba7260 · Cited by 157 · see citing works
Norman, J. J., Brown, M. R., Raviele, N., Prausnitz, M. R., & Felner, E. I. (2013) · Pediatric Diabetes · doi:10.1111/pedi.12031 · Cited by 142 · see citing works
Point-of-care sensors for the management of sepsis
Reddy, B., Hassan, U., Seymour, C., Angus, D. C., Isbell, T. S., White, K., Weir, W., Yeh, L., Vincent, A., & Bashir, R. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0288-9 · Cited by 142 · see citing works
Smartphone-powered iontophoresis-microneedle array patch for controlled transdermal delivery
Yang, J., Li, Y., Ye, R., Zheng, Y., Li, X., Chen, Y., Xie, X., & Jiang, L. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00224-z · Cited by 117 · see citing works
Self-citationChua, B., Desai, S. P., Tierney, M. J., Tamada, J. A., & Jina, A. N. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.09.026 · Cited by 111 · see citing works
Jin, Q., Chen, H., Li, X., et al. (2019) · Small · doi:10.1002/smll.201804298 · Cited by 108 · see citing works
Self-citationMicroneedle Electrodes Toward an Amperometric Glucose‐Sensing Smart Patch
Invernale, M. A., Tang, B. C., York, R. L., Le, L. V., Hou, D. Y., & Anderson, D. G. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300142 · Cited by 100 · see citing works
Closed-loop insulin delivery for treatment of type 1 diabetes
Elleri, D., Dunger, D. B., & Hovorka, R. (2011) · BMC Medicine · doi:10.1186/1741-7015-9-120 · Cited by 99 · see citing works
Lee, S. J., Yoon, H. S., Xuan, X., Park, J. Y., Paik, S., & Allen, M. G. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.08.013 · Cited by 94 · see citing works
Yoon, Y., Lee, G. U., Yoo, K., & Lee, J. (2013) · Sensors · doi:10.3390/s131216672 · Cited by 85 · see citing works
Management of diabetes mellitus: is the pump mightier than the pen?
Pickup, J. C. (2012) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2012.28 · Cited by 77 · see citing works
Wang, Y., Wang, C., Li, K., Song, X., Yan, X., Yu, L., & He, Z. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.01.002 · Cited by 69 · see citing works
Toward Closing the Loop: An Update on Insulin Pumps and Continuous Glucose Monitoring Systems
Aye, T., Block, J. M., & Buckingham, B. A. (2010) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2010.05.005 · Cited by 40 · see citing works
Kwon, S., Nam, S. H., Park, C. Y., Baek, S., Jang, J., Che, X., Kwak, S. H., Choi, Y., Park, N. R., Choi, J., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705952 · Cited by 32 · see citing works
CytoPAN—Portable cellular analyses for rapid point-of-care cancer diagnosis
Min, J., Chin, L. K., Oh, J., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaz9746 · Cited by 29 · see citing works
Diabetes Technologies and Their Role in Diabetes Management
Kollipara, S., Silverstein, J. H., & Marschilok, K. (2009) · American Journal of Health Education · doi:10.1080/19325037.2009.10599105 · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [3]a) S. Kollipara, J. H. Silverstein, K. Marschilok, Am. J. Health Educ. 2009, 40, 292; b) X. Zhuo, P. Zhang, L. Barker, A. Albright, T. J. Thompson, E. Gregg, Diabetes Care 2014, 37, 2557; 25147254 c) D. R. Owens, B. Zinman, G. B. Bolli, Lancet 2001, 358, 739. 11551598
Cited by
Sorted by citations
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535 · see citing works
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442 · see citing works
Cheng, S., Gu, Z., Zhou, L., Hao, M., An, H., Song, K., Wu, X., Zhang, K., Zhao, Z., Dong, Y., et al. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.765987 · Cited by 64 · see citing works
- Authors
- Li, X., Huang, X., Mo, J., Wang, H., Huang, Q., Yang, C., Zhang, T., Chen, H., Hang, T., Liu, F., Jiang, L., Wu, Q., Li, H., Hu, N., & Xie, X.
- Affiliations
- Sun Yat-sen University (CN)
- Corresponding author
- Xie, Xi
- ORCID
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2021-06-03
- Volume
- 8
- Issue
- 16
- Pages
- e2100827-e2100827
- ISSN
- 2198-3844 (ISSN-L)
- PMC
- PMC8373098
- OpenAlex
- W3165239041
- Cited by
- 250
- References
- 55
- Citations by year
- 2026: 38 · 2025: 58 · 2024: 60 · 2023: 49 · 2022: 39 · 2021: 6
- FWCI
- 15.74
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Advanced Science (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (61771498, 82061148011, 81970778, 61901535, 31900954)
- China Postdoctoral Science Foundation (2020M683079)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Keywords
- iontophoresis, insulin delivery, diabetes treatment, wearable medical devices, flexible printed circuit board, hyperglycemia, stratum corneum penetration
- MeSH terms
- Animals, Diabetes Mellitus, Experimental, Disease Models, Animal, Hypoglycemic Agents, Insulin, Iontophoresis, Male, Microinjections, Needles, Rats, Sprague-Dawley, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review